Resultados 1 - 20 de 132
Filtrar
1.
Clin Hemorheol Microcirc ; 86(3): 263-273, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38489171

RESUMEN

BACKGROUND: The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS: A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS: Of n = 70 (mean value 48,3 years±20,3 years, range 18-84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS: The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis.


Asunto(s)
Carcinoma Hepatocelular , Diagnóstico por Imagen de Elasticidad , Neoplasias Hepáticas , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Medios de Contraste , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Viscosidad , Hígado/diagnóstico por imagen , Hígado/patología , Ultrasonografía/métodos
2.
Ultraschall Med ; 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38335990

RESUMEN

PURPOSE: Complete resection of the affected tissue remains the best curative treatment option for liver-derived tumors and colorectal liver metastases. In addition to preoperative cross-sectional imaging, contrast-enhanced intraoperative ultrasound (CE-IOUS) plays a crucial role in the detection and localization of all liver lesions. However, its exact role is unclear. This study was designed to evaluate the clinical and oncological impact of using CE-IOUS in the surgical treatment of these diseases. MATERIALS AND METHODS: Over the three-year study period, 206 patients with primary liver tumors and hepatic metastases were enrolled in this prospective, monocentric study to evaluate the impact of CE-IOUS in liver surgery. Secondary outcomes included comparing the sensitivity and specificity of CE-IOUS with existing preoperative imaging modalities and identifying preoperative parameters that could predict a strategic impact of CE-IOUS. In addition, the oncological significance of CE-IOUS was evaluated using a case-cohort design with a minimum follow-up of 18 months. RESULTS: CE-IOUS findings led to a change in surgical strategy in 34% of cases (n=70/206). The accuracy in cases with a major change could be confirmed histopathologically in 71.4% of cases (n=25/35). The impact could not be predicted using parameters assumed to be clinically relevant. An oncological benefit of a CE-IOUS adapted surgical approach was demonstrated in patients suffering from HCC and colorectal liver metastases. CONCLUSION: CE-IOUS may significantly increase R0 resection rates and should therefore be used routinely as an additional staging method, especially in complex liver surgery.

3.
Ultraschall Med ; 45(1): 36-46, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37748503

RESUMEN

Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.


Asunto(s)
Medios de Contraste , Neoplasias , Humanos , Ultrasonografía/métodos , Perfusión
4.
Clin Hemorheol Microcirc ; 86(1-2): 89-97, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37574725

RESUMEN

OBJECTIVE: To test and initially describe a new handheld wireless ultrasound technique (TE Air) for clinical use. METHODS: In this pilot study, the new ultrasound device TE Air from Mindray was used to examine the hepatic and renal vessels of healthy volunteers for first impressions. The probe has a sector transducer with a frequency range of 1.8-4.5 MHz. The B-mode and color-coded doppler sonography (CCDS) scanning methods were used. A high-end device from the same company (Resona 9, Mindray) was used as a reference. The results were evaluated using an image rating scale ranging from 0 to 5, with 0 indicating not assessable and 5 indicating without limitations. RESULTS: Altogether, 61 participants (n = 34 female [55.7%], n = 27 male [44.3%]), age range 18-83 years, mean age 37.9±16.5 years) could be adequately studied using TE AIR and the high-end device. With one exception, the image quality score for TE Air never fell below 3 and had a mean/median scored of 4.97/5.00 for the B-mode, 4.92/5.00 for the color flow (CF) mode, and 4.89/5.00 for the pulse wave (PW) mode of the hepatic vein, 4.90/5.00 for the portal vein, 4.11/4.00 for the hepatic artery, and 4.57/5.00 for the renal segmental artery. A significant difference in the assessment of flow measurement of the hepatic artery and renal segmental arteries was found between TE AIR and the high-end device. CONCLUSIONS: TE Air represents a new dimension in point-of-care ultrasound via wireless handheld devices. Especially, its flow measurement ability offers a relevant advantage over other available handheld models. TE Air provides a formally sufficient image quality in terms of diagnostic significance.


Asunto(s)
Vena Porta , Ultrasonografía Doppler en Color , Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Proyectos Piloto , Ultrasonografía , Vena Porta/diagnóstico por imagen , Hígado
5.
Med Ultrason ; 26(1): 50-62, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37632826

RESUMEN

Improved detection and characterization of common focal liver lesions (FLL) are the main topics of the World Federation for Ultrasound in Medicine and Biology (WFUMB) guidelines on the use of contrast-enhanced ultrasound (CEUS). On stateof-the-art CEUS imaging, to create a library of rare FLL, especially concerning their atypical imaging characteristics, might be helpful for improving clinical diagnostic efficiency. In this review, we aim to summarize the ultrasound and CEUS features of rare benign FLL. Currently there are limited reports and images published.


Asunto(s)
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/patología , Medios de Contraste , Ultrasonografía/métodos
6.
Clin Hemorheol Microcirc ; 86(1-2): 121-131, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37638426

RESUMEN

AIM: To evaluate the usefulness of handheld ultrasound in comparison with high-end ultrasound for lesion evaluation before and after sclerotherapy in pediatric patients with venous malformations (VMs). MATERIAL AND METHODS: 10 pediatric patients prior to and after sclerotherapy were scanned by an experienced examiner using handheld ultrasound (Vscan AirTM) and high-end ultrasound (LOGIQ E9/E10) as reference. Patients with associated venous thromboses and intralesional aneurysms had been excluded. Results were interpreted independently by two readers in consensus. RESULTS: 10 patients (4-17 years; 10.0±4.32 years; female n = 6, male n = 4) with 10 VMs (4 of the head and neck region, 4 of the upper and 2 of the lower extremities) were examined. 7 phleboliths were detected. The average rating score achieved by the high-end device never was less than 4, by Vscan AirTM never less than 3. An exception was the assessment of AV fistulas. In comparison with the evaluation of variables examined, we found a significant difference between the high-end scanner and the handheld device regarding the achieved image quality. CONCLUSION: Vscan AirTM ultrasound device allows new possibilities for procedure planning and post-procedural control of pediatric patients with VMs.


Asunto(s)
Malformaciones Vasculares , Humanos , Niño , Masculino , Femenino , Malformaciones Vasculares/diagnóstico por imagen , Malformaciones Vasculares/terapia , Ultrasonografía , Escleroterapia/métodos , Venas/diagnóstico por imagen , Cuello , Resultado del Tratamiento , Estudios Retrospectivos
7.
Clin Hemorheol Microcirc ; 86(3): 313-326, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37927251

RESUMEN

OBJECTIVES: To evaluate the efficacy of the radiomics model based on preoperative B-mode ultrasound (BMUS) and shear wave elastography (SWE) for predicting the occurrence of clinically relevant-postoperative pancreatic fistula (CR-POPF). METHODS: Patients who were scheduled to undergo pancreatectomy were prospectively enrolled and received ultrasound assessment within one week before surgery. The risk factors of POPF (grades B and grades C) were analyzed. Preoperative BMUS images, SWE values of pancreatic lesions and surrounding parenchyma were used to build preoperative prediction radiomics models. Radiomic signatures were extracted and constructed using a minimal Redundancy Maximal Relevance (mRMR) algorithm and an L1 penalized logistic regression. A combined model was built using multivariate regression which incorporated radiomics signatures and clinical data. RESULTS: From January 2020 to November 2021, a total of 147 patients (85 distal pancreatectomies and 62 pancreaticoduodenectomies) were enrolled. During the three-week follow-up after pancreatectomy, the incidence rates of grade B/C POPF were 28.6% (42/147). Radiomic signatures constructed from BMUS of pancreas parenchymal regions (panRS) achieved an area under the receiver operating characteristic curve (AUC) of 0.75, accuracy of 68.7%, sensitivity of 85.7 %, and specificity of 61.9 % in preoperative noninvasive prediction of CR-POPF. The AUC of the radiomics model increased to 0.81 when panRS was used for the prediction of CR-POPF after pancreaticoduodenectomy. CONCLUSIONS: Radiomics model based on ultrasound images was potentially useful for predicting CR-POPF. Patients with high-risk factors should be closely monitored when postoperation.


Asunto(s)
Pancreatectomía , Fístula Pancreática , Humanos , Pancreatectomía/efectos adversos , Fístula Pancreática/etiología , Fístula Pancreática/complicaciones , Radiómica , Páncreas/diagnóstico por imagen , Páncreas/cirugía , Pancreaticoduodenectomía/efectos adversos , Factores de Riesgo , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/patología , Estudios Retrospectivos
8.
J Gastrointestin Liver Dis ; 32(4): 479-487, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38147619

RESUMEN

AIMS: To assess the value of using integrated parametric ultrasound software for contrast-enhanced ultrasonography (CEUS) of liver tumors. METHODS: 107 patients with liver tumors were studied. CEUS were performed to detect focal lesions. Parametric images were based on continuous CINE LOOPs, from the early-arterial phase (15 s) to the portal-venous phase (1 min) generated by perfusion software. The evaluations of the parametric images and their dignity for liver lesions were performed independently by an experienced and a less-experienced investigator. Computed tomography, magnetic resonance imaging scans or histological analysis were used as references. RESULTS: High parametric image quality were obtained in all patients. Among the patients, 44% lesions were benign, 56% were malignant. The experienced investigator correctly classified 46 of 47 (98%) as benign, and 60 of 60 (100%) as malignant tumors based on the parametric images. The less-experienced investigator correctly classified 39 of 47 (83%) as benign, and 49 of 60 (82%) malignant tumors, acheaving a high statistical accuracy of 98% with this type of diagnostic. CONCLUSION: Parametric imaging for grading the malignant degree of tumor may be a good complement to existing ultrasound techniques and was particularly helpful for improving the assessments of the less-experienced examiner.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Neoplasias Hepáticas , Ultrasonografía , Humanos , Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Perfusión/métodos , Sensibilidad y Especificidad , Ultrasonografía/métodos , Programas Informáticos
9.
Med Ultrason ; 2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38150699

RESUMEN

The diagnosis or rare mesenchymal malignant lesions of the liver may be a challenge owing to the rarity of the disease and is usually made by histological confirmation. An ultrasound examination with, if required, color Doppler sonography and contrast-enhanced ultrasound, taking into account the clinical background of the patient, may help to focus the differential diagnosis. In this review, we describe the pathological and ultrasound features of several rare mesenchymal malignant liver lesions which include undifferentiated sarcoma of the liver, leiomyosarcoma, angiosarcoma, fibrosarcoma, liposarcoma, and epithelioid hemangioendothelioma.

10.
Artículo en Inglés | MEDLINE | ID: mdl-37980654

RESUMEN

BACKGROUND: Rapid evolution of ultrasound technology has allowed widespread use of handheld ultrasound devices (HHUDs) for many possible applications. Along with the adult population, the use of HHUDs for Point of Care Ultrasound (POCUS) in pediatric medicine has been increasing over the last few years. However, pediatric-specific literature is still scarce on mobile vascular ultrasound. OBJECTIVE: To evaluate diagnostic capabilities of Vscan Air™ in comparison with high-end ultrasound for the assessment of the internal jugular vein in children and adolescents. METHODS: 42 Internal Jugular Veins (IJVs) of 21 pediatric patients were scanned by an experienced examiner using a WLAN-supported handheld ultrasound device (Vscan Air™) and high-end cart-based ultrasound (LOGIQ E9) as reference. B-Mode and Color-coded Doppler (CCDS) were performed and compared. Image quality was assessed using a score of 0 to 5 and statistically analyzed. Results were interpreted independently by two readers in consensus. RESULTS: 21 patients (2-17 years; mean 11,00±4,5 years; female n = 11, male n = 10) were examined. The rating score never dropped below 3 for both devices. The median score evaluation of B-Mode and CCDS for the high-end device was 5.00, of Vscan Air™ 5.00 for B-Mode and 4.00 for CCDS. A significant difference was shown between the two devices in the evaluation of CCDS. CONCLUSIONS: Vscan Air™ ultrasound device allows sufficient assessability of the IJV in pediatric patients, opening up new possibilities for fast and mobile POCUS of cervical veins and potential guidance of central venous catheter placement.

11.
Clin Hemorheol Microcirc ; 85(1): 87-92, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37599526

RESUMEN

AIM: To apply intraoperative ultrasound (IO-US) for the first time using a laparascopic probe to detect malignancy-susceptible solitary pulmonary nodules (SPN) and assess macrovascularization using color-coded doppler sonography or power doppler. Description of technical feasibility. METHODS: Technical description on intrathoracic endoscopic ultrasound. A positive ethics vote from the local ethics committee and written patient consent were available. Intraoperative ultrasound was performed using a laparascopic probe (Lap 13-4cs, Mindray) on the T9 ultrasound machine (Mindray, China). B-scan was used to detect the SPN. Color-coded doppler sonography (CCS) and power doppler were used to assess macrovascularization. Primary end point was the description of the technical performance of the Io-US. Secondary endpoints were the functions of Io-US in characterizing SPN. RESULTS: Io-US was successfully applied using (n = 2) cases in video-assisted thoracic surgery. All SPN were successfully detected intraoperatively with the intrathoracically placed laparascopy probe using B-mode and examined using CCS or power Doppler (100%). Resection was sonography-guided with marking of the tumor area in all cases without complications. Histological workup revealed malignancy in both cases. CONCLUSION: Intrathoracic application of laparascopically guided Io-US was technically feasible. In addition to B-mode detection, Io-US using power doppler and color-coded doppler sonography provided initial evidence for characterization of SPN based on macrovascularization.

12.
Med Ultrason ; 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-37632825

RESUMEN

It is important to be familiar with the typical imaging features of the uncommon or even extremely rare focal liver lesions (FLL). Current guidelines of the World Federation for Ultrasound in Medicine and Biology (WFUMB) is aimed at assessing the usefulness of contrast enhanced ultrasound (CEUS) in the management of various FLL. In this review, we aim to summarize the ultrasound and CEUS characteristics with literature review of some extremely rare benign FLL, which might be helpful for improving diagnostic efficiency clinically.

13.
Cancers (Basel) ; 15(15)2023 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-37568670

RESUMEN

BACKGROUND: The intraoperative detection of solitary pulmonary nodules (SPNs) continues to be a major challenge, especially in minimally invasive video-assisted thoracic surgery (VATS). The location, size, and intraoperative frozen section result of SPNs are decisive regarding the extent of lung resection. This feasibility study investigates the technical applicability of intraoperative contrast-enhanced ultrasonography (Io-CEUS) in minimally invasive thoracic surgery. METHODS: In this prospective, monocentric clinical feasibility study, n = 30 patients who underwent Io-CEUS during elective minimally invasive lung resection for SPNs between October 2021 and February 2023. The primary endpoint was the technical feasibility of Io-CEUS during VATS. Secondary endpoints were defined as the detection and characterization of SPNs. RESULTS: In all patients (female, n = 13; mean age, 63 ± 8.6 years) Io-CEUS could be performed without problems during VATS. All SPNs were detected by Io-CEUS (100%). SPNs had a mean size of 2.2 cm (0.5-4.5 cm) and a mean distance to the lung surface of 2.0 cm (0-6.4 cm). B-mode, colour-coded Doppler sonography, and contrast-enhanced ultrasound were used to characterize all tumours intraoperatively. Significant differences were found, especially in vascularization as well as in contrast agent behaviour, depending on the tumour entity. After successful lung resection, a pathologic examination confirmed the presence of lung carcinomas (n = 17), lung metastases (n = 10), and benign lung tumours (n = 3). CONCLUSIONS: The technical feasibility of Io-CEUS was confirmed in VATS before resection regarding the detection of suspicious SPNs. In particular, the use of Doppler sonography and contrast agent kinetics revealed intraoperative specific aspects depending on the tumour entity. Further studies on Io-CEUS and the application of an endoscopic probe for VATS will follow.

14.
Clin Hemorheol Microcirc ; 85(1): 83-86, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37545228

RESUMEN

In the head and neck area, a large proportion of clinically relevant fistulas occur in childhood. The present case describes the use of contrast enhanced ultrasound with intraductal administration of the contrast medium for preoperative visualization of the fistula duct in the case of a second brachial cleft fistula. This provided the surgeon with important additional information, such as the detailed course of the fistula and its relation to the large vessels of the neck. The method can help to improve surgical planning, reduce radiation exposure and to avoid imaging under general anesthesia, especially in children.


Asunto(s)
Fístula , Enfermedades Faríngeas , Ultrasonografía , Niño , Humanos , Región Branquial/cirugía , Fístula/diagnóstico por imagen , Fístula/cirugía , Cuello/diagnóstico por imagen , Cuello/cirugía , Enfermedades Faríngeas/cirugía , Cuidados Preoperatorios
15.
Curr Oncol ; 30(7): 6734-6743, 2023 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-37504354

RESUMEN

Metastatic cervical lymph nodes are a frequent finding in head and neck squamous cell carcinoma (HNSCC). If a non-surgical approach is primarily chosen, a therapy response evaluation of the primary tumor and the affected lymph nodes is necessary in the follow-up. Supplementary contrast-enhanced ultrasound (CEUS) can be used to precisely visualize the microcirculation of the target lesion in the neck, whereby malignant and benign findings differ in their uptake behavior. The same applies to many other solid tumors. For various tumor entities, it has already been shown that therapy monitoring is possible through regular contrast-enhanced sonography of the primary tumor or the affected lymph nodes. Thus, in some cases, maybe in the future, a change in therapy strategy can be achieved at an early stage in the case of non-response or, in the case of therapy success, a de-escalation of subsequent (surgical) measures can be achieved. In this paper, a systematic review of the available studies and a discussion of the potential of therapy monitoring by means of CEUS in HNSCC are presented.


Asunto(s)
Neoplasias de Cabeza y Cuello , Ganglios Linfáticos , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Cuello , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/terapia , Ultrasonografía
16.
Laryngorhinootologie ; 102(6): 450-463, 2023 06.
Artículo en Alemán | MEDLINE | ID: mdl-37267968

RESUMEN

With the help of contrast enhanced ultrasound, the diagnostic accuracy of conventional sonography can be increased in many areas of otorhinolaryngology. Vascularisation and tissue perfusion can be objectified through the examination. This offers promising approaches for example to monitor the therapy of metastatic cervical lymph nodes or in the treatment of vascular malformations. Contrast Enhanced Ultrasound (CEUS) also offers great potential for differential diagnosis, for example of thyroid nodules. Valid threshold values for the quantitative time intensity curve (TIC) analysis of cervical pathologies are currently still not available. Further studies are necessary. As there is currently no license for the use of contrast enhanced ultrasound in otorhinolaryngology patients must be informed about its off-label use before the examination. This article is intended to provide an overview of the current possibilities and to serve as an introduction to the topic.


Asunto(s)
Medios de Contraste , Nódulo Tiroideo , Humanos , Cabeza , Ganglios Linfáticos/diagnóstico por imagen , Cuello/diagnóstico por imagen , Ultrasonografía
17.
Tomography ; 9(2): 681-692, 2023 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-36961013

RESUMEN

BACKGROUND: Modern ultrasound (US) shear-wave dispersion (SWD) and attenuation imaging (ATI) can be used to quantify changes in the viscosity and signal attenuation of the liver parenchyma, which are altered in hepatic steatosis. We aimed to evaluate modern shear-wave elastography (SWE), SWD and ATI for the assessment of hepatic steatosis. METHODS: We retrospectively analyzed the US data of 15 patients who underwent liver USs and MRIs for the evaluation of parenchymal disease/liver lesions. The USs were performed using a multifrequency convex probe (1-8 MHz). The quantitative US measurements for the SWE (m/s/kPa), the SWD (kPa-m/s/kHz) and the ATI (dB/cm/MHz) were acquired after the mean value of five regions of interest (ROIs) was calculated. The liver MRI (3T) quantification of hepatic steatosis was performed by acquiring proton density fat fraction (PDFF) mapping sequences and placing five ROIs in artifact-free areas of the PDFF scan, measuring the fat-signal fraction. We correlated the SWE, SWD and ATI measurements to the PDFF results. RESULTS: Three patients showed mild steatosis, one showed moderate steatosis and eleven showed no steatosis in the PDFF sequences. The calculated SWE cut-off (2.5 m/s, 20.4 kPa) value identified 3/4 of patients correctly (AUC = 0.73, p > 0.05). The SWD cut-off of 18.5 m/s/kHz, which had a significant correlation (r = 0.55, p = 0.034) with the PDFF results (AUC = 0.73), identified four patients correctly (p < 0.001). The ideal ATI (AUC = 0.53 (p < 0.05)) cut-off was 0.59 dB/cm/MHz, which showed a significantly good correlation with the PDFF results (p = 0.024). CONCLUSION: Hepatic steatosis can be accurately detected using all the US-elastography techniques applied in this study, although the SWD and the SWE showed to be more sensitive than the PDFF.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Ultrasonografía/métodos , Imagen por Resonancia Magnética/métodos
18.
Plast Reconstr Surg ; 152(4): 866-870, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36780356

RESUMEN

BACKGROUND: In the setting of facial palsy, synkinesis of the depressor anguli oris (DAO) muscle is a common pathology, impairing dynamic and resting facial symmetry.In this prospective study, the authors used high-resolution ultrasound (HRUS) to evaluate the morphologic features of DAO and to quantify bilateral differences in DAO cross-sectional diameter (CSD) in individuals with unilateral synkinesis. METHODS: From June of 2020 to May of 2021, 30 patients (19 women, 11 men) with clinically diagnosed unilateral synkinesis underwent evaluation with HRUS. DAO CSD was measured bilaterally, 1 cm inferior to the modiolus, in both the resting and smiling positions. RESULTS: The Sunnybrook Facial Grading System Synkinesis Score was 6.20 ± 2.48 (range, 0 to 10). DAO CSD at rest measured 2.41 ± 0.67 mm (range, 1.40 to 4.00 mm) on the control side and 2.66 ± 0.98 mm (range, 1.60 to 5.10 mm) on the affected side. On the control side, DAO CSD was reduced by -0.19 ± 0.43 mm (range, -1.10 to 1.12 mm) during smiling. In contrast, the synkinetic DAO CSD increased by 0.64 ± 0.38 mm (range, 0.00 to 1.59 mm) ( P < 0.001) with animation. The pattern of increased CSD in synkinetic DAO muscles and decreased or unchanged CSD on the control side during smiling was identified in 70% of patients. CONCLUSIONS: HRUS demonstrates increased CSD in synkinetic DAO muscles during active smiling. The opposite is true for DAO muscles on the control side, which exhibit decreased CSD with animation. HRUS can be performed preoperatively to objectify DAO dysfunction and guide targeted therapy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.


Asunto(s)
Parálisis Facial , Sincinesia , Masculino , Humanos , Femenino , Estudios Prospectivos , Músculos Faciales/diagnóstico por imagen , Parálisis Facial/cirugía , Sonrisa/fisiología
19.
Clin Hemorheol Microcirc ; 83(4): 397-408, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36683499

RESUMEN

BACKGROUND: Cervical lymphadenopathy can be benign or malignant. Its accurate diagnosis is necessary to determine appropriate treatment. Ultrasound-guided core needle biopsies (US-CNBs) are frequently used as a percutaneous sampling approach. OBJECTIVES: Our aim was to identify the efficacy and safety of US-CNBs in 125 patients with cervical lymphadenopathy and clinically suspected head and neck cancer during the COVID-19 pandemic with limited surgical resources. METHODS: US-CNBs of pathological lymph nodes were performed in 146 lymph nodes on 125 patients. Biopsies were performed ultrasound-guided with a reusable gun core biopsy system and a 10-cm-long 16-G needle. Standard of reference for the histological findings were panendoscopy, clinical and sonographic follow-up, surgical biopsy or a repeat US-CNB. RESULTS: Adequate material for histologic diagnosis was obtained in 111 patients (89%), of these 83 patients (75%) were diagnosed as malignant, whereas benign lymphadenopathy accounted for 28 patients (25%). Therefore, US-CNB was able to identify malignant or benign lymphadenopathy with an overall accuracy of 88% and 90%, respectively. CONCLUSIONS: Percutaneous US-CNB is a safe and effective alternative to surgical biopsy in the management of cervical lymphadenopathy in patients with clinically suspected head and neck cancer in a setting with limited resources.


Asunto(s)
COVID-19 , Neoplasias de Cabeza y Cuello , Linfadenopatía , Humanos , Biopsia con Aguja Gruesa , Pandemias , Linfadenopatía/diagnóstico por imagen , Biopsia Guiada por Imagen , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Ultrasonografía Intervencional , Estudios Retrospectivos
20.
Clin Hemorheol Microcirc ; 83(4): 409-420, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36683500

RESUMEN

OBJECTIVES: To explore the potential added value of dynamic contrast enhanced ultrasound (DCE-US) using VueBox® software for the diagnosis of small solid thyroid nodules (≤1.0 cm). PATIENTS AND METHODS: This prospective study was approved by the institutional review board and it was performed at two hospitals from January 2020 to October 2020. B mode ultrasound and contrast enhanced ultrasound (CEUS) images were obtained for 79 small solid thyroid nodules (≤1.0 cm) confirmed by ultrasound-guided fine needle aspiration cytology results in 79 consecutive patients (55 women and 24 men, median age: 41 years). The CEUS time-intensity curves (TICs) of thyroid nodules and surrounding parenchyma were created by VueBox® software (Bracco, Italy). The CEUS quantitative parameters were obtained after curve fitting. The diagnostic performance of CEUS and DCE-US was evaluated and compared. The weighted kappa statistic (κ) was performed to assess the interobserver agreement and consistency between the diagnosis of CEUS and DCE-US. RESULTS: Among the 79 thyroid nodules, 56 (70.9 %) were malignant and 23 (29.1 %) were benign lesions. Hypoenhancement during the arterial phase of CEUS was associated with malignancy (P < 0.001), with an AUC of 0.705 (sensitivity 71.4 %, specificity 69.6 %). Among all CEUS quantitative parameters, the peak enhancement (PE), wash-in rate (WiR), and wash-out rate (WoR) of DCE-US in malignancies were significantly lower than those in benign nodules (P = 0.049, P = 0.046, and P = 0.020, respectively). The area under the receiver operating characteristic curves (AUCs) of PE, WiR, and WoR were 0.642 (sensitivity 65.2 %, specificity 67.9 %), 0.643 (sensitivity 43.5 %, specificity 91.1 %), and 0.667 (sensitivity 69.6 %, specificity 69.6 %) in differentiation between benign and malignant small solid thyroid nodules (≤1.0 cm), respectively. Comparing the quantitative parameters of DCE-US between small solid thyroid nodules and surrounding normal thyroid parenchyma, the PE, WiAUC, WiR, wash-in perfusion index (WiPI), WoAUC, WiWoAUC, and WoR of the nodules were significantly lower than those of normal thyroid tissue (P = 0.008, P < 0.001, P = 0.037, P = 0.009, P = 0.003, P = 0.002, P = 0.049, respectively). A total of 16 (20.3 %) nodules showed isoenhancement during the arterial phase of CEUS, while the median PE ratio of surrounding tissue and thyroid nodules was 1.70 (IQR: 1.33-1.89). CONCLUSIONS: VueBox® is a helpful tool for the evaluation of dynamic microvascularization of thyroid nodules, and DCE-US using VueBox® perfusion analysis could provide added values for differential diagnosis of small solid thyroid nodules (≤1.0 cm).


Asunto(s)
Nódulo Tiroideo , Masculino , Humanos , Femenino , Adulto , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Estudios Prospectivos , Medios de Contraste , Perfusión/métodos , Ultrasonografía/métodos , Diagnóstico Diferencial