Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
BMC Nephrol ; 25(1): 52, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38336628

RESUMEN

BACKGROUND: The aim of this study was to investigate whether bioactive adrenomedullin (bio-ADM) and interleukin-6 (IL-6) are related to acute kidney injury (AKI) and severe illness in COVID-19 patients. METHODS: 153 patients with COVID-19 admitted to the emergency department (ED) were included. Blood samples were collected from each patient at admission. Bio-ADM and IL-6, as well as DPP3 and routinely measured markers were evaluated regarding the endpoints AKI (22/128 hospitalized patients) and a composite endpoint of admission to intensive care unit and/or in-hospital death (n = 26/153 patients). RESULTS: Bio-ADM and IL-6 were significantly elevated in COVID-19 patients with AKI compared to COVID-19 patients without AKI (each p < 0.001). According to ROC analyses IL-6 and bio-ADM had the largest AUC (0.84 and 0.81) regarding the detection of AKI. Furthermore, bio-ADM and IL-6 were significantly elevated in COVID-19 patients reaching the composite endpoint (each p < 0.001). Regarding the composite endpoint ROC analysis showed an AUC of 0.89 for IL-6 and 0.83 for bio-ADM in COVID-19 patients. In the multivariable logistic model bio-ADM and IL-6 presented as independent significant predictors regarding both endpoints AKI and the composite endpoint in COVID-19 patients (as well as creatinine regarding the composite endpoint; each p < 0.05), opposite to leukocytes, C-reactive protein (CRP) and dipeptidyl peptidase 3 (DPP3; each p = n.s.). CONCLUSION: Elevated levels of bio-ADM and IL-6 are associated with AKI and critical illness in patients with COVID-19. Therefore, both biomarkers may be potential tools in risk stratification in COVID-19 patients at presentation in the ED.


Asunto(s)
Lesión Renal Aguda , Biomarcadores , COVID-19 , Humanos , Lesión Renal Aguda/diagnóstico , Adrenomedulina/análisis , Biomarcadores/análisis , COVID-19/diagnóstico , Enfermedad Crítica , Mortalidad Hospitalaria , Interleucina-6/análisis , Estudios Prospectivos
2.
Catheter Cardiovasc Interv ; 102(7): 1376-1385, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37727885

RESUMEN

OBJECTIVES: The aim of the current study was to analyze the clinical and procedural predictors of thrombocytopenia and the relationship between the decrease in platelet count (DPC) and change in vWF function (ΔvWF) after transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR often causes temporary thrombocytopenia. At the same time, TAVR leads to a restoration of von Willebrand factor (vWF) function. METHODS: One hundred and forty-one patients with severe aortic stenosis undergoing TAVR were included in the study. Platelet count and vWF function (vWF:Ac/Ag ratio) were assessed at baseline and 6 h after TAVR. Thrombocytopenia was defined as platelet count <150/nL. RESULTS: Median platelet count at baseline was 214/nL (interquartile range [IQR]: 176-261) and decreased significantly to 184/nL (IQR: 145-222) 6 h after TAVR. The number of patients with thrombocytopenia increased from 12.8% at baseline to 29.1% after 6 h. DPC 6 h after TAVR showed a significant correlation with ΔvWF (r = - 0.254, p = 0.002). Patients with DPC > 20% had significantly higher ΔvWF (10.9% vs. 6.5%, p = 0.021). Obese patients showed a significantly lower DPC (11.8% vs. 19.9%, p = 0.001). In multivariate analysis, ΔvWF 6 h after TAVR was the only significant predictor for DPC > 20% (p = 0.017). CONCLUSIONS: The restoration of vWF after TAVR is a significant predictor for DPC after TAVR. An increased platelet consumption due to vWF restoration could play a key role in the development of thrombocytopenia after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Trombocitopenia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factor de von Willebrand , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Factores de Riesgo , Trombocitopenia/diagnóstico , Trombocitopenia/etiología
3.
Clin Exp Med ; 23(8): 4919-4935, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37733154

RESUMEN

Coronavirus SARS-CoV-2 spread worldwide, causing a respiratory disease known as COVID-19. The aim of the present study was to examine whether Dipeptidyl-peptidase 3 (DPP3) and the inflammatory biomarkers IL-6, CRP, and leucocytes are associated with COVID-19 and able to predict the severity of pulmonary infiltrates in COVID-19 patients versus non-COVID-19 patients. 114 COVID-19 patients and 35 patients with respiratory infections other than SARS-CoV-2 were included in our prospective observational study. Blood samples were collected at presentation to the emergency department. 102 COVID-19 patients and 28 non-COVID-19 patients received CT imaging (19 outpatients did not receive CT imaging). If CT imaging was available, artificial intelligence software (CT Pneumonia Analysis) was used to quantify pulmonary infiltrates. According to the median of infiltrate (14.45%), patients who obtained quantitative CT analysis were divided into two groups (> median: 55 COVID-19 and nine non-COVID-19, ≤ median: 47 COVID-19 and 19 non-COVID-19). DPP3 was significantly elevated in COVID-19 patients (median 20.85 ng/ml, 95% CI 18.34-24.40 ng/ml), as opposed to those without SARS-CoV-2 (median 13.80 ng/ml, 95% CI 11.30-17.65 ng/ml; p < 0.001, AUC = 0.72), opposite to IL-6, CRP (each p = n.s.) and leucocytes (p < 0.05, but lower levels in COVID-19 patients). Regarding binary logistic regression analysis, higher DPP3 concentrations (OR = 1.12, p < 0.001) and lower leucocytes counts (OR = 0.76, p < 0.001) were identified as significant and independent predictors of SARS-CoV-2 infection, as opposed to IL-6 and CRP (each p = n.s.). IL-6 was significantly increased in patients with infiltrate above the median compared to infiltrate below the median both in COVID-19 (p < 0.001, AUC = 0.78) and in non-COVID-19 (p < 0.05, AUC = 0.81). CRP, DPP3, and leucocytes were increased in COVID-19 patients with infiltrate above median (each p < 0.05, AUC: CRP 0.82, DPP3 0.70, leucocytes 0.67) compared to infiltrate below median, opposite to non-COVID-19 (each p = n.s.). Regarding multiple linear regression analysis in COVID-19, CRP, IL-6, and leucocytes (each p < 0.05) were associated with the degree of pulmonary infiltrates, as opposed to DPP3 (p = n.s.). DPP3 showed the potential to be a COVID-19-specific biomarker. IL-6 might serve as a prognostic marker to assess the extent of pulmonary infiltrates in respiratory patients.


Asunto(s)
COVID-19 , Humanos , Inteligencia Artificial , Biomarcadores , COVID-19/diagnóstico , Prueba de COVID-19 , Dipeptidil-Peptidasas y Tripeptidil-Peptidasas , Interleucina-6 , SARS-CoV-2
4.
Kidney Blood Press Res ; 48(1): 424-435, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37364545

RESUMEN

INTRODUCTION: The ongoing COVID-19 pandemic is placing an extraordinary burden on our health care system with its limited resources. Accurate triage of patients is necessary to ensure medical care for those most severely affected. In this regard, biomarkers could contribute to risk evaluation. The aim of this prospective observational clinical study was to assess the relationship between urinary N-terminal pro-brain natriuretic peptide (NT-proBNP) and acute kidney injury (AKI) as well as severe disease in patients with COVID-19. METHODS: 125 patients treated with an acute respiratory infection in the emergency department of the University Hospital Regensburg were analyzed. These patients were divided into a COVID-19 cohort (n = 91) and a cohort with infections not caused by severe acute respiratory syndrome-coronavirus-2 (n = 34). NT-proBNP was determined from serum and fresh urine samples collected in the emergency department. Clinical endpoints were the development of AKI and a composite one consisting of AKI, intensive care unit admission, and in-hospital death. RESULTS: 11 (12.1%) COVID-19 patients developed AKI during hospitalization, whereas 15 (16.5%) reached the composite endpoint. Urinary NT-proBNP was significantly elevated in COVID-19 patients who suffered AKI or reached the composite endpoint (each p < 0.005). In a multivariate regression analysis adjusted for age, chronic kidney disease, chronic heart failure, and arterial hypertension, urinary NT-proBNP was identified as independent predictor of AKI (p = 0.017, OR = 3.91 [CI: 1.28-11.97] per standard deviation [SD]), as well as of the composite endpoint (p = 0.026, OR 2.66 [CI: 1.13-6.28] per SD). CONCLUSION: Urinary NT-proBNP might help identify patients at risk for AKI and severe disease progression in COVID-19.


Asunto(s)
Lesión Renal Aguda , COVID-19 , Insuficiencia Cardíaca , Humanos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Biomarcadores , COVID-19/complicaciones , Insuficiencia Cardíaca/complicaciones , Mortalidad Hospitalaria , Péptido Natriurético Encefálico , Pandemias , Fragmentos de Péptidos , Pronóstico , Estudios Prospectivos
5.
J Cardiovasc Dev Dis ; 10(3)2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36975862

RESUMEN

BACKGROUND: Pulmonary vein (PV) reconnection is the major cause of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI). The probability of reconnection is higher if the primary lesion is not sufficiently effective, which can be unmasked with an adenosine provocation test (APT). High-power short-duration radiofrequency energy (HPSD) guided with ablation index (AI) and the third generation of the visually guided laser balloon (VGLB) are new methods for PVI. METHODS: A total of 70 participants (35 in each group) who underwent a PVI with either AI-guided HPSD (50 W; AI 500 for the anterior and 400 for the posterior wall, respectively) or VGLB ablation were included in this observational pilot trial. Twenty minutes after each PVI, an APT was performed. The primary endpoint was the event-free survival from AF after three years. RESULTS: A total of 137 (100%) PVs in the HPSD arm and 131 PVs (98.5%) in the VGLB arm were initially successfully isolated (p = 0.24). The overall procedure duration was similar in both arms (155 ± 39 in HPSD vs. 175 ± 58 min in VGLB, p = 0.191). Fluoroscopy time, left atrial dwelling time and duration from the first to the last ablation were longer in the VGLB arm (23 ± 8 vs. 12 ± 3 min, p < 0.001; 157 (111-185) vs. 134 (104-154) min, p = 0.049; 92(59-108) vs. 72 (43-85) min, p = 0.010). A total of 127 (93%) in the HPSD arm and 126 (95%) PVs in the VGLB arm remained isolated after APT (p = 0.34). The primary endpoint was met 1107 ± 68 days after ablation in 71% vs. 66% in the VGLB and HPSD arms, respectively (p = 0.65). CONCLUSIONS: HPSD and VGLB did not differ with respect to long-term outcome of PVI. A large, randomized study should be conducted to compare clinical outcomes with respect to these new ablation techniques.

6.
Eur J Med Res ; 27(1): 234, 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36348435

RESUMEN

PURPOSE: The current study investigated whether the changes in patient care in times of the COVID-19 pandemic, especially the reduction of in-person visits, would result in a deterioration of the arrhythmic and clinical condition of patients with an implantable cardioverter defibrillator (ICD) and remote patient monitoring. METHODS: Data were obtained from a local ICD registry. 140 patients who received ICD implantation at our department and had remote patient monitoring were included. The number of patients with ventricular arrhythmias, appropriate ICD therapy, the number of visits to our outpatient clinic and hospitalization due to acute coronary syndrome, stroke or heart failure were compared during three time intervals of the COVID-19 pandemic (first (LD1) and second (LD2) national lockdown in Germany and the time after the first lockdown (postLD1)) and a time interval 1 year before the pandemic began (preCOV). Each time interval was 49 days long. RESULTS: Patients had significantly fewer visits to our outpatient clinic during LD1 (n = 13), postLD1 (n = 22) and LD2 (n = 23) compared to the time interval before the pandemic (n = 43, each p ≤ 0.05). The number of patients with sustained ventricular arrhythmias, appropriate ICD therapy and clinical events showed no significant difference during the time intervals of the COVID-19 pandemic and the time interval 1 year prior. CONCLUSIONS: The lockdown measures necessary to reduce the risk of infection during the COVID-19 pandemic, led to a reduction of in-person patient visits, but did not result in a deterioration of the arrhythmic and clinical condition of ICD patients with remote patient monitoring.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Humanos , Pandemias , COVID-19/epidemiología , Control de Enfermedades Transmisibles , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Monitoreo Fisiológico
7.
PLoS One ; 17(8): e0269816, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35960722

RESUMEN

OBJECTIVES: The study aims to investigate the impact of COVID-19 pandemic on physical activity and frequency of implantable cardioverter-defibrillator (ICD) therapies of patients with cardiac implantable electronic devices. METHODS AND RESULTS: Physical activity, heart rate and ICD-therapies were assessed via routine remote monitoring over two years. We focussed on a 338-day period during COVID-19 pandemic that was divided in 6 time-intervals defined by public health interventions and compared to the previous regular year. Paired nonparametric longitudinal analysis was performed to detect differences between time-intervals. To model effects of age, sex and time we applied a nonparametric ANOVA-type-statistic. 147 patients with cardiac implantable electronic devices were analysed. Longitudinal analysis of physical activity in 2019 and 2020 showed a specific weekly and seasonal pattern. Physical activity was reduced during the pandemic (mean daily physical activity 2019: 12.4% vs. 2020: 11.5%; p<0.0001) with the strongest reductions (fold changes 0.885/0.889, p<0.0001/p<0.0001) during the two lockdown-periods. In older patients (>70 years), physical activity was decreased in every time-interval of the year 2020. In time-intervals of eased restrictions, physical activity of younger patients (≤70 years) was not different compared to 2019. No variation in mean heart rate, arrhythmia-burden and count of ICD-therapies was found. CONCLUSION: Physical activity shows fluctuations dependent on days of the week and time of the year. During the pandemic, physical activity was reduced in patients with cardiac implantable electronic devices with the strongest reductions during lockdown-periods. Younger patients resumed former levels of physical activity in times of eased restrictions while older patients remained less active. Thus, activation of the elderly population is important to prevent long-term health impairments due to the pandemic.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Anciano , COVID-19/epidemiología , Control de Enfermedades Transmisibles , Electrónica , Ejercicio Físico , Humanos , Pandemias
8.
Clin Res Cardiol ; 111(12): 1348-1357, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35838799

RESUMEN

BACKGROUND: Aortic stenosis (AS) can cause acquired von Willebrand syndrome (AVWS) and valve replacement has been shown to lead to von Willebrand factor (vWF) recovery. The aim of the current study was to investigate the prevalence of AVWS in different severe AS phenotypes and its course after transcatheter aortic valve implantation (TAVI). METHODS: 143 patients with severe AS undergoing TAVI were included in the study. vWF function was assessed at baseline, 6 and 24 h after TAVI. AVWS was defined as a reduced vWF:Ac/Ag ratio ≤ 0.7. Phenotypes were classified by tricuspid (TAV) and bicuspid (BAV) valve morphology, mean transvalvular gradient (Pmean), stroke volume index (SVI), ejection fraction (EF) and indexed effective orifice area (iEOA). RESULTS: AVWS was present in 36 (25.2%) patients before TAVI. vWF:Ac/Ag ratio was significantly lower in high gradient compared to low-gradient severe AS [0.78 (IQR 0.67-0.86) vs. 0.83 (IQR 0.74-0.93), p < 0.05] and in patients with BAV compared to TAV [0.70 (IQR 0.63-0.78) vs. 0.81 (IQR 0.71-0.89), p < 0.05]. Normalization of vWF:Ac/Ag ratio was achieved in 61% patients 24 h after TAVI. As in the overall study cohort, vWF:Ac/Ag ratio increased significantly in all severe AS subgroups 6 h after TAVI (each p < 0.05). Regarding binary logistic regression analysis, BAV was the only significant predictor for AVWS. CONCLUSIONS: BAV morphology is a strong predictor for AVWS in severe AS. TAVI restores vWF function in most patients with severe AS independently of AS phenotype and valve morphology.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades de von Willebrand , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factor de von Willebrand , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Enfermedades de von Willebrand/etiología , Enfermedades de von Willebrand/cirugía
9.
Biomark Med ; 16(4): 265-275, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35176879

RESUMEN

Aim: NAG and KIM-1 as markers of tubular damage are suggested as potential biomarkers for the cardiorenal syndrome. The aim of the study was to assess the prognostic capability of NAG and KIM-1 regarding progression of chronic kidney disease (CKD) in patients with implantable cardioverter defibrillator (ICD). Materials & methods: We included 313 patients with an ICD and collected plasma and urine samples. Follow-up was performed after 51 months (interquartile range [IQR]: 25-55). The outcome of interest was continuous CKD progression defined as persistent decline in estimated glomerular filtration rate category accompanied by a ≥25% drop of baseline estimated glomerular filtration rate. Results: An average of four (IQR: 2-6) follow-up values of serum creatinine per patient were obtained. During follow-up 29 patients (9%) developed a continuous CKD progression. NAG was shown as independent predictor for continuous CKD progression (p = 0.01), opposite to KIM-1 (p = n.s.). Conclusion: NAG was shown as predictor for a progressive and real deterioration of kidney function in patients with ICD.


Asunto(s)
Síndrome Cardiorrenal , Desfibriladores Implantables , Insuficiencia Renal Crónica , Biomarcadores , Progresión de la Enfermedad , Femenino , Tasa de Filtración Glomerular , Humanos , Masculino , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/terapia
11.
Aging Clin Exp Res ; 34(5): 1073-1080, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34751924

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy is well established for secondary prevention, but studies on the efficacy and safety in elderly patients are still lacking. This retrospective study compared the outcome after ICD implantation between octogenarians and other age groups. METHODS: Data were obtained from a local ICD registry. Patients who received ICD implantation for secondary prevention at our department were included. All-cause mortality, appropriate ICD therapy and acute adverse events requiring surgical intervention were compared between different age groups. RESULTS: 519 patients were enrolled, 34 of whom were aged ≥ 80 years. During the median follow-up of 35 months after ICD implantation 129 patients (annual mortality rate 5.0%) had died, including 16 patients aged ≥ 80 years (annual mortality rate 9.4%). The mortality rate of patients aged ≥ 80 years was significantly higher than that of patients aged ≤ 69 years (p < 0.001), but similar to that of patients aged 70-79 years. Age at the time of ICD implantation was an independent predictor of all-cause mortality (p < 0.001). 29.7% of patients had appropriate ICD therapy with no difference between age groups. Acute adverse events leading to surgical intervention were low (n = 13) and not age-related. CONCLUSION: Age is an independent predictor of mortality after ICD implantation for secondary prevention. Mortality rates did not differ significantly between octogenarians and other elderly aged 70-79 years. Appropriate ICD therapy and acute adverse events leading to surgical intervention were not age-related. Implantable cardioverter-defibrillator therapy for secondary prevention seems to be an effective and safe treatment modality in octogenarians.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Anciano , Anciano de 80 o más Años , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Humanos , Octogenarios , Prevención Primaria , Estudios Retrospectivos , Factores de Riesgo , Prevención Secundaria , Resultado del Tratamiento
12.
Angiology ; 73(3): 252-259, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34362260

RESUMEN

The increasing number of patients treated with cardiac implantable electronic devices (CIEDs) and indications for complex pacing requires system revisions. Currently, data on venous patency in repeat CIED surgery involving lead (re)placement or extraction are largely missing. This study aimed to assess venous patency and risk factors in patients referred for repeat CIED lead surgery, emphasizing CIED infection. All consecutive patients requiring extraction, exchange, or additional placement of ≥1 CIED leads during reoperative procedures from January 2015 to March 2020 were evaluated in this retrospective study. Venography was performed in 475 patients. Venous patency could be assessed in 387 patients (81.5%). CIED infection with venous occlusion was detected in 74 patients compared with venous occlusion without infection in 14 patients (P < .05). Concerning venous patency, novel oral anticoagulant medication appeared to be protective (P < .05; odds ratio [OR]: .35). Infection of the CIED appeared to be strongly associated with venous occlusion (OR: 16.0). The sensitivity was only 64.15%, but the specificity was 96.1%. Number of leads involved and previous CIED procedures were not associated with venous occlusion. In conclusion, in patients with CIED, venous occlusion was strongly associated with device infection, but not with the number of leads or previous CIED procedures.


Asunto(s)
Desfibriladores Implantables , Enfermedades Vasculares , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Reoperación/métodos , Estudios Retrospectivos , Enfermedades Vasculares/etiología
13.
Front Immunol ; 12: 740260, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34745111

RESUMEN

Increased left ventricular fibrosis has been reported in patients hospitalized with coronavirus disease 2019 (COVID-19). It is unclear whether this fibrosis is a consequence of severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) infection or a risk factor for severe disease progression. We observed increased fibrosis in the left ventricular myocardium of deceased COVID-19 patients, compared with matched controls. We also detected increased mRNA levels of soluble interleukin-1 receptor-like 1 (sIL1-RL1) and transforming growth factor ß1 (TGF-ß1) in the left ventricular myocardium of deceased COVID-19 patients. Biochemical analysis of blood sampled from patients admitted to the emergency department (ED) with COVID-19 revealed highly elevated levels of TGF-ß1 mRNA in these patients compared to controls. Left ventricular strain measured by echocardiography as a marker of pre-existing cardiac fibrosis correlated strongly with blood TGF-ß1 mRNA levels and predicted disease severity in COVID-19 patients. In the left ventricular myocardium and lungs of COVID-19 patients, we found increased neuropilin-1 (NRP-1) RNA levels, which correlated strongly with the prevalence of pulmonary SARS-CoV-2 nucleocapsid. Cardiac and pulmonary fibrosis may therefore predispose these patients to increased cellular viral entry in the lung, which may explain the worse clinical outcome observed in our cohort. Our study demonstrates that patients at risk of clinical deterioration can be identified early by echocardiographic strain analysis and quantification of blood TGF-ß1 mRNA performed at the time of first medical contact.


Asunto(s)
COVID-19/fisiopatología , Ventrículos Cardíacos/patología , Miocardio/patología , Fibrosis Pulmonar/fisiopatología , SARS-CoV-2/fisiología , Adulto , Anciano , COVID-19/inmunología , Femenino , Fibrosis , Ventrículos Cardíacos/metabolismo , Humanos , Proteína 1 Similar al Receptor de Interleucina-1/genética , Proteína 1 Similar al Receptor de Interleucina-1/metabolismo , Masculino , Persona de Mediana Edad , Miocardio/metabolismo , Neuropilina-1/genética , Neuropilina-1/metabolismo , Fibrosis Pulmonar/inmunología , Riesgo , Índice de Severidad de la Enfermedad , Factor de Crecimiento Transformador beta1/genética , Factor de Crecimiento Transformador beta1/metabolismo , Carga Viral
14.
Biomark Med ; 15(18): 1709-1719, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34783584

RESUMEN

Aim: We assessed the 10-year prognostic role of 11 biomarkers with different pathophysiological backgrounds. Materials & methods/results: Blood samples from 144 patients with heart failure were analyzed. After 10 years of follow-up (median follow-up was 104 months), data regarding all-cause mortality were acquired. Regarding Kaplan-Meier analysis, all markers, except TIMP-1 and GDF-15, were significant predictors for all-cause mortality. We created a multimarker model with nt-proBNP, hs-TnT and IGF-BP7 and found that patients in whom all three markers were elevated had a significantly worse long-time prognosis than patients without elevated markers. Conclusion: In a 10-year follow-up, a combination of three biomarkers (NT-proBNP, hs-TnT, IGF-BP7) identified patients with a high risk of mortality.


Asunto(s)
Biomarcadores/sangre , Insuficiencia Cardíaca/sangre , Anciano , Área Bajo la Curva , Enfermedad Crónica , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos Biológicos , Pronóstico , Modelos de Riesgos Proporcionales
15.
J Clin Med ; 10(21)2021 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-34768499

RESUMEN

Left ventricular (LV) ejection fraction (LVEF) is the most widely used prognostic marker in cardiovascular diseases. LV global function index (LVGFI) is a novel marker which incorporates the total LV structure in the assessment of LV cardiac performance. We evaluated the prognostic significance of LVGFI, measured by cardiovascular magnetic resonance (CMR), in predicting mortality and ICD therapies in a real-world (ICD) population with secondary ICD prevention indication, to detect a high-risk group among these patients. In total, 105 patients with cardiac MRI prior to the ICD implantation were included (mean age 56 ± 16 years old; 76% male). Using the MRI data for each patient LVGFI was determined and a cut-off for the LVGFI value was calculated. Patients were followed up every four to six months in our or clinics in proximity. Data on the occurrence of heart failure symptoms and or mortality, as well as device therapies and other vital parameters, were collected. Follow up duration was 37 months in median. The mean LVGFI was 24.5%, the cut off value for LVGFI 13.5%. According to the LVGFI Index patient were divided into 2 groups, 86 patients in the group with the higher LVGFI und 19 patients in the lower group. The LVGFI correlates significantly with the LVEF (r = 0.642, p < 0.001). In Kaplan-Meier analysis, a lower LVGFI (<13.5%) was associated with a higher rate of mortality and rehospitalization (p = 0.002). In contrast, echocardiographic LVEF ≤ 33% was not associated with a higher rate of mortality or rehospitalization. Multivariate Cox-regression analysis revealed a lower LVGFI (p = 0.025, HR = 0.941; 95%-CI 0.89-0.99) and diabetes mellitus (p = 0.027, HR = 0.33; 95%-CI 0.13-0.88) as an independent predictor for mortality and rehospitalization. There was no association between the combined endpoint and the LVEFMRT, LVEFecho, NYHA > I, the initial device or a medication (each p = n.s.). Further, in Kaplan-Meier analysis no association was evident between the LVGFI and adequate ICD therapy (p = n.s.). In secondary prevention ICD patients reduced LVGFI was shown as an independent predictor for mortality and rehospitalization, but not for ICD therapies. We were able to identify a high-risk collective among these patients, but further investigation is needed to evaluate LVGFI compared to ejection fraction, especially in patients with an elevated risk for adverse cardiac events.

16.
Pacing Clin Electrophysiol ; 44(12): 2015-2023, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34687476

RESUMEN

BACKGROUND: Aim of the study was a better characterization of heart failure (HF) with recovered ejection fraction (HFrecEF) and undulating EF (HFuEF) with regard to re-hospitalization due to congestive HF (CHF), adequate electric therapies (AETs) and mortality compared to HF with reduced EF (HFrEF), mid-range EF (HFmrEF) and preserved EF (pEF). METHODS: Retrospective study of 342 participants with an implantable cardioverter defibrillator (ICD) for primary or secondary prevention. Type of HF was classified according to left ventricular EF with 4.7 ± 3.1 investigations for each patient. RESULTS: Re-hospitalization due to CHF was similar in HFrecEF (7 (9.5%)), HFmrEF (2(9.0%)) and pEF (8(12.9%); p = n.s.) and significantly higher in HFrEF (62(38.0%)) and HFuEF (6(28.6%); p < .001 compared to HFrecEF and HFrEF). AETs were significantly lower in HFrecEF (13(17.6%)) compared to HFrEF (57(35.0%)), HFmrEF (7(31.8%)), pEF (18(29.0%)) and HFuEF (6(28.6%); each p < .01 compared to HFrecEF). Mortality was similar in HFrecEF (6(8.1%)) compared to HFuEF (0(0%)), pEF (4(6.5%)) and HFmrEF (2(9.0%), p = n.s.) and significantly lower compared to HFrEF (52(31.9%), p < .001). HFrEF was the strongest predictor for mortality besides age and chronic renal insufficiency according to Cox Regression (each p < .05) opposite to arterial hypertension, diabetes, type of cardiomyopathy and secondary prevention ICD indication (each p = n.s.). CONCLUSIONS: HFrecEF indicates as a new entity of HF with similar prognosis as pEF and HFmrEF with regard to re-hospitalization due to CHF and mortality and even better prognosis with regard to AETs. HFuEF showed similar rates of re-hospitalization due to CHF and AETs compared to HFrEF, but lower rates of mortality.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Readmisión del Paciente/estadística & datos numéricos , Volumen Sistólico , Anciano , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Prevención Primaria , Pronóstico , Estudios Retrospectivos , Prevención Secundaria
17.
Biomark Med ; 15(13): 1143-1153, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34397265

RESUMEN

Aim: The study focused on biomarkers of kidney injury as predictors of mortality in patients with chronic heart failure (CHF) in a long-term follow-up (median 104 months). Methods/results: KIM-1, NAG and NGAL were assessed from urine, NT-proBNP from blood samples. 149 patients (age 62 ± 12 years) with CHF (mean EF 30% [IQR 24-40%]) were enrolled. 79 (53%) patients died. Cox regression analysis revealed Log2NAG (HR: 1.46, CI: 1.12-1.89), Log2KIM-1 (HR: 1.23, CI: 1.02-1.49) and Log2NT-proBNP (HR: 1.50, CI: 1.32-1.72) as significant predictors of all-cause mortality as opposed to Log2NGAL (HR: 1.04, CI: 0.90-1.20). Log2NAG remained a significant predictor of all-cause mortality in a multivariate Cox regression model but lost its predictive value in combination with Log2NT-proBNP. Conclusion: The 10-year follow-up suggests NAG as a predictive tubular marker in CHF patients.


Asunto(s)
Acetilglucosaminidasa/orina , Biomarcadores/sangre , Biomarcadores/orina , Insuficiencia Cardíaca/diagnóstico , Anciano , Enfermedad Crónica , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Receptor Celular 1 del Virus de la Hepatitis A/metabolismo , Humanos , Estimación de Kaplan-Meier , Lipocalina 2/orina , Masculino , Persona de Mediana Edad , Péptido Natriurético Encefálico/sangre , Readmisión del Paciente/estadística & datos numéricos , Fragmentos de Péptidos/sangre , Pronóstico , Modelos de Riesgos Proporcionales , Tasa de Supervivencia , Factores de Tiempo
18.
J Nephrol ; 34(4): 1007-1018, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34110585

RESUMEN

AIMS: The aim of the current study was to evaluate whether tubular markers kidney injury molecule-1 (KIM-1) and N-acetyl-ß-glucosaminidase (NAG) are related to acute kidney injury (AKI) and severe disease in patients with COVID-19. METHODS AND RESULTS: In this prospective observational clinical trial we examined a cohort of 80 patients with proof of acute respiratory infection and divided them into a COVID-19 cohort (n = 54) and a control cohort (n = 26). KIM-1 and NAG were measured from urine samples collected in the emergency department. We assessed the development of AKI, admission to the intensive care unit (ICU) and intrahospital death as clinical endpoints. Urinary KIM-1 and NAG were not significantly different between patients with SARS-CoV-2 and those with other respiratory infections (each p = n.s.). Eight patients from the COVID-19 cohort and five of the non-COVID-19-patients suffered from acute kidney injury during their stay. Nine COVID-19 patients and two non-COVID-19 patients were admitted to the ICU. KIM-1 was significantly elevated in COVID-19 patients with, compared to those without AKI (p = 0.005), as opposed to NAG and creatinine (each p = n.s.). Furthermore, KIM-1 was significantly elevated in the patients with COVID-19 that had to be transferred to the ICU (p = 0.015), in contrast to NAG and creatinine (each p = n.s.). CONCLUSION: Assessing KIM-1 in patients with COVID-19 might provide additional value in recognizing AKI at an early stage of disease. Further, KIM-1 might indicate higher risk for clinical deterioration as displayed by admission to the ICU.


Asunto(s)
Lesión Renal Aguda , COVID-19 , Lesión Renal Aguda/diagnóstico , Biomarcadores , Receptor Celular 1 del Virus de la Hepatitis A , Humanos , Riñón , SARS-CoV-2 , Índice de Severidad de la Enfermedad
19.
ESC Heart Fail ; 8(3): 2293-2305, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33822463

RESUMEN

AIMS: The objective of this study was to investigate the prognostic value of urinary N-terminal pro-brain natriuretic peptide (NT-proBNP) compared with plasma NT-proBNP in patients presenting with acute chest pain in the emergency department. METHODS AND RESULTS: We measured simultaneously plasma and urinary NT-proBNP at admission in 301 patients with acute chest pain. In our cohort, 174 patients suffered from acute coronary syndrome (ACS). A follow-up (median of 55 months) was performed regarding the endpoints all-cause mortality and major adverse cardiac events (mortality, congestive heart failure, ACS with the necessity of a coronary intervention, and stroke). Fifty-four patients died during follow-up; 98 suffered from the combined endpoint. A significant and positive correlation of urinary and plasma NT-proBNP was found (r = 0.87, P < 0.05). Patients with troponin positive ACS had significantly elevated levels of plasma and urinary NT-proBNP compared with those with unstable angina pectoris or chest wall syndrome (each P < 0.05). The highest levels of both biomarkers were found in patients with congestive heart failure (each P < 0.05). According to Kaplan-Meier analysis, plasma and urinary NT-proBNP were significant predictors for mortality and the combined endpoint in the whole study cohort and in the subgroup of patients with ACS (each P < 0.05). Regarding Cox regression analysis, plasma and urinary NT-proBNP were independent predictors for mortality and the combined endpoint (each P < 0.05). CONCLUSIONS: Urinary NT-proBNP seems to provide a significant predictive value regarding the endpoints all-cause mortality and major adverse cardiac events in patients with acute chest pain and those with ACS.


Asunto(s)
Péptido Natriurético Encefálico , Fragmentos de Péptidos , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/epidemiología , Dolor en el Pecho/etiología , Humanos , Pronóstico
20.
Circ J ; 85(3): 291-299, 2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33563865

RESUMEN

BACKGROUND: Implantable cardioverter defibrillator (ICD) therapies, even when appropriate, are associated with increased risk. Therapy-reducing strategies have been shown to reduce the mortality rate.Methods and Results:In total, 895 patients with ICD and cardiac resynchronization therapy with defibrillation function (CRT-D) were included in the study; of these, 506 (57%) patients undergoing secondary prevention were included. Devices implanted before May 2014 were programmed according to conventional programming (CP), the others according to our novel programming (NP) with high rate cut-off, longer detection intervals and 4-6 anti-tachycardia pacing (ATP) trains in the ventricular tachycardia (VT) zone. Time-to-first-event for mortality, appropriate and inappropriate therapies were analyzed. Follow-up time was 24.0 months (IQR 13.0-24.0 months). There was a significant reduction in mortality rate (11.4% vs. 25.4%, P<0.001) and in the rate of appropriate (18.8% vs. 42.2%, P<0.001) and inappropriate therapies (5.2% vs. 18.0%, P<0.001) with NP according to Kaplan-Meier analyses. In multivariate analysis, NP (hazard ratio [HR]=0.35; P<0.001), chronic kidney disease (HR=1.55), reduced ejection fraction (EF) (HR=1.35), secondary ICD indication (HR=2.35) and age at implantation (HR=1.02) were associated with mortality reduction. NP was also associated with significant reduction in the rate of appropriate and inappropriate therapies. These results were consistent after stratification for primary and secondary prevention. CONCLUSIONS: Novel ICD programming reduced mortality and morbidity due to appropriate or inappropriate ICD therapies in secondary as well as in primary ICD indication.


Asunto(s)
Fibrilación Atrial/prevención & control , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Fibrilación Atrial/mortalidad , Cardioversión Eléctrica , Humanos , Estimación de Kaplan-Meier , Taquicardia Ventricular/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...