Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Am Chem Soc ; 139(6): 2512-2519, 2017 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-28097863

RESUMEN

Organelle-targeted photosensitization represents a promising approach in photodynamic therapy where the design of the active photosensitizer (PS) is very crucial. In this work, we developed a macromolecular PS with multiple copies of mitochondria-targeting groups and ruthenium complexes that displays highest phototoxicity toward several cancerous cell lines. In particular, enhanced anticancer activity was demonstrated in acute myeloid leukemia cell lines, where significant impairment of proliferation and clonogenicity occurs. Finally, attractive two-photon absorbing properties further underlined the great significance of this PS for mitochondria targeted PDT applications in deep tissue cancer therapy.

2.
Eur J Radiol ; 85(2): 489-97, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26781156

RESUMEN

OBJECTIVES: To retrospectively assess the diagnostic performance of hip MR arthrography with and without traction in detecting ligamentum teres (LT) lesions with arthroscopic correlation and to evaluate the effect of traction on the imaging appearance of the LT. METHODS: 73 MR arthrograms (73 consecutive patients, mean age, 34.5 years; range, 14-55 years) obtained without and with leg traction (application of 15-23 kg, use of a supporting plate for the contralateral leg) were included. Two blinded readers independently evaluated LT lesions on MR arthrograms on separate occasions: coronal images without traction; coronal images with traction; a multiplanar traction protocol. MR findings were correlated with arthroscopic records. Sensitivity/specificity of traction and non-traction imaging was compared on coronal images with the exact McNemar test. Imaging appearance of the LT with and without traction was assessed in consensus and compared on coronal images using McNemar and McNemar-Bowker tests. (p<0.05, * corrected for type I error). RESULTS: With arthroscopy 29 (40%) LT lesions were identified in 73 patients. Sensitivity was 72%/90% (without traction/with traction; p=0.25*), specificity was 89%/77% (p=0.25*) for reader 1 in assessing coronal images and for reader 2 sensitivity was 59%/86% (p=0.044*) and specificity was 93%/82% (p=0.25*). Alterations in fiber orientation, signal intensity, surface, dimension, fiber continuity after application of traction were observed in 33/73 (45%, p=0.002*), 6/73 (8%, p=0.223), 9/73 (12%, p=0.36*), 6/73 (8%, p=0.031) respectively 9/73 (12%, p=0.003) cases. Traction-related alterations in at least one criterion were observed in 41/73 (56%) cases. CONCLUSION: Application of traction can considerably alter the imaging appearance of the LT and resulted in higher rates of true-positive and false-positive findings compared to conventional MR arthrography.


Asunto(s)
Artrografía/métodos , Artroscopía/métodos , Lesiones de la Cadera/patología , Imagen por Resonancia Magnética/métodos , Ligamentos Redondos/lesiones , Ligamentos Redondos/patología , Tracción , Adolescente , Adulto , Medios de Contraste , Femenino , Gadolinio DTPA , Articulación de la Cadera/patología , Humanos , Aumento de la Imagen , Yopamidol , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
4.
Eur Radiol ; 25(6): 1721-30, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25465714

RESUMEN

OBJECTIVES: To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. METHODS: Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. RESULTS: No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. CONCLUSION: Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. KEY POINTS: • The used traction technique was well tolerated by most patients. • The used traction technique almost consistently achieved separation of cartilage layers. • Traction MR arthrography enabled accurate detection of chondral and labral lesions.


Asunto(s)
Enfermedades de los Cartílagos/patología , Articulación de la Cadera/patología , Artropatías/patología , Adolescente , Adulto , Artrografía/métodos , Artroscopía/métodos , Cartílago Articular/patología , Medios de Contraste , Femenino , Humanos , Inyecciones Intraarticulares , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Tracción/métodos , Adulto Joven
5.
Acad Radiol ; 21(10): 1240-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24981959

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate the feasibility of a modified approach for direct magnetic resonance (MR) arthrography of the hip under leg traction in achieving a sufficient femoroacetabular interface and improving the visualization of the ligamentum teres. MATERIALS AND METHODS: Forty-six MR arthrograms of 44 patients who underwent MR arthrography with and without leg traction were included into the study. Traction approach included injection of 18-27 mL of fluid (local anesthetic, contrast agent), application of weight-adapted traction load (15-23 kg), and the use of a supporting plate. Patients were instructed to report on pain and complications with an integer pain scale. Joint distraction was measured on coronal images obtained with and without traction, and two radiologists independently evaluated whether femoroacetabular cartilage layers and the ligamentum teres could be seen as distinct entities. McNemar test was used and interobserver agreement was assessed. RESULTS: No patient asked for termination of the examination. There were no cases of neuropraxia. Mean difference in distraction was 3.7 mm/3.6 mm (reader 1/reader 2). Cartilage layers could be seen as distinct entities in 43/43 (93.5%/93.5%) and 6/8 (13%/17.4%) of the joints with/without traction (P < .001/P < .001), respectively. The ligamentum teres could be differentiated in 33/30 (71.7%/65.2%) cases with traction, in 33/30 (71.7%/65.2%) cases without traction (P < .999/P < .999), and in 40/37 (87%/80.4%) cases with both the techniques combined. CONCLUSIONS: Traction MR arthrography is safe and technically feasible. It enabled the differentiation between femoroacetabular cartilage layers in most cases. Visualization of the ligamentum teres was optimal by combining imaging with both modalities.


Asunto(s)
Cartílago Articular/patología , Articulación de la Cadera/patología , Aumento de la Imagen/métodos , Ligamentos Articulares/patología , Imagen por Resonancia Magnética/métodos , Posicionamiento del Paciente/métodos , Tracción/métodos , Algoritmos , Artralgia/diagnóstico , Artralgia/etiología , Artrografía/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Humanos , Variaciones Dependientes del Observador , Posicionamiento del Paciente/efectos adversos , Posicionamiento del Paciente/instrumentación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Tracción/efectos adversos , Tracción/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...