Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Open Heart ; 7(2)2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32690553

RESUMEN

OBJECTIVE: A multidisciplinary heart valve team is recommended for the evaluation of treatment in patients with valvular heart disease, but evidence supporting this concept is lacking. In patients with severe mitral regurgitation, we thought to analyse the patient selection process by the heart team for different treatment options and the outcome after treatment. METHODS: In this single-centre cohort study, all patients treated for mitral regurgitation between July 2013 and September 2018 were included. Primary end points during follow-up were all-cause mortality and a combined end point, consisting of all-cause mortality, cardiovascular rehospitalisation and mitral valve reintervention. RESULTS: 179 patients (44.8%) were treated using Mitraclip, 185 (46.2%) by surgical repair and 36 (9.0%) by surgical replacement. The mortality risk according to EuroScore II differed significantly between treatment groups (6.6%±5.6%, 1.7%±1.5% and 3.6%±2.7% for Mitraclip, surgical repair and replacement, respectively, p<0.001). In-hospital mortality for the 3 groups were 3.4%, 1.6% and 8.3%, respectively (p=0.091). Overall, surgical repair patients had higher 4-year survival (HR 0.40 (95% CI 0.26 to 0.63), p<0.001) and fewer combined end points (HR 0.51 (95% CI 0.32 to 0.80), p<0.001) compared with surgical replacement and Mitraclip patients. However, patients undergoing Mitraclip for isolated, primary mitral regurgitation achieved very good long-term survival. CONCLUSION: The multidisciplinary heart team assigned only low-risk patients with favourable anatomy to surgical repair, while high-risk patients underwent Mitraclip or surgical replacement. This strategy was associated with lower than expected in-hospital mortality for Mitraclip patients and high 4-year survival rates for patients undergoing surgical or percutaneous repair of isolated primary mitral regurgitation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Grupo de Atención al Paciente , Anciano , Anciano de 80 o más Años , Toma de Decisiones Clínicas , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Readmisión del Paciente , Selección de Paciente , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
3.
Eur Heart J Cardiovasc Imaging ; 19(1): 23-30, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28065915

RESUMEN

Aims: The Edwards Sapien 3 heart valve prosthesis (S3) is commonly used for transcatheter aortic valve implantation (TAVI) and is available in three sizes. To date no data has been published on the effective orifice area (EOA) and the hemodynamic performance of the three different S3 sizes. The aim of this study was to measure the size-specific EOA and hemodynamic performance of the S3 in short-term and 1-year follow-up. Methods and results: One hundred and thirteen consecutive patients treated by TAVI with a S3 prosthesis at the Heart Clinic Zurich between May 2014 and July 2015 were included. Clinical data were extracted from the Swiss TAVI registry. The EOA was calculated using Doppler echocardiography (peri-interventionally and at discharge) and by 3D-biplane transoesophageal echocardiography (peri-interventionally). Mean transvalvular gradients (dPmean) were additionally calculated with Doppler echocardiography at 30 days and 1 year. Results were analysed separately for the 23 mm (n = 42; 37%), 26 mm (n = 46; 41%), and 29 mm (n = 25; 22%) prostheses. At discharge, the EOAs were 1.6 ± 0.2 cm2 (23 mm S3), 2.0 ± 0.2 cm2 (26 mm S3), and 2.7 ± 0.2 cm2 (29 mm S3), p < 0.001. The dPmeans at discharge were 10.9 ± 6.0 mmHg (23 mm S3), 10.4 ± 3.5 mmHg (26 mm S3), and 8.9 ± 2.8 mmHg (29 mm S3), p = 0.235, and did not significantly change over time within any of the S3 sizes. Conclusions: Post-TAVI, the EOAs of the three different S3 prosthesis sizes differ significantly, the transvalvular gradients, however, are comparable. Mean transvalvular gradients remain stable over time and document good prosthesis function after 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anatomía & histología , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Análisis de Varianza , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Cohortes , Ecocardiografía/métodos , Ecocardiografía Transesofágica/métodos , Femenino , Estudios de Seguimiento , Humanos , Modelos Lineales , Masculino , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Suiza , Centros de Atención Terciaria , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...