Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Clin Pharm Ther ; 41(6): 711-717, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27671101

RESUMEN

WHAT IS KNOWN AND OBJECTIVE: Although inappropriate use of digoxin has been described in various populations, a real-world evaluation of patterns of digoxin prescription has not been well studied in patients with atrial fibrillation (AF). The aim of this study was to identify prevalence, indications and appropriateness of digoxin use in the general population of patients with non-valvular AF (NVAF) in Turkey. METHODS: We included and classified patients from the RAMSES (ReAl-life Multicentre Survey Evaluating Stroke prevention strategies in Turkey) study, a prospective registry including 6273 patients with NVAF, on the basis of digoxin use. After excluding the data of 73 patients whose medical history about digoxin use or left ventricle function was absent, 6200 patients were included for the final analysis. Digoxin use was considered inappropriate if patients did not have left ventricular systolic dysfunction or symptomatic heart failure (HF). RESULTS AND DISCUSSION: Digoxin was used in 1274 (20·5%) patients. Patients treated with digoxin were older (71·4 ± 9·8 years vs. 69·2 ± 10·9 years, P < 0·001), more likely to be female (58·8% vs. 55·9%, P = 0·019) and had more common comorbidities such as HF (40·2% vs. 17·4%), diabetes (26·4% vs. 21·1%), coronary artery disease (35·3 vs. 27·6%) and persistent/permanent AF (93·4% vs. 78·4%; P < 0·001 for each comparison). Of the 1274 patients, the indication of digoxin use was considered inappropriate in 762 (59·8%). WHAT IS NEW AND CONCLUSION: Our findings show that nearly one-fifth of the patients with NVAF were on digoxin therapy and nearly 60% of these patients were receiving digoxin with inappropriate indications in a real-world setting.


Asunto(s)
Fibrilación Atrial/tratamiento farmacológico , Digoxina/uso terapéutico , Anciano , Comorbilidad , Femenino , Insuficiencia Cardíaca/tratamiento farmacológico , Ventrículos Cardíacos/efectos de los fármacos , Humanos , Masculino , Estudios Prospectivos , Accidente Cerebrovascular/tratamiento farmacológico , Turquía
3.
Herz ; 41(5): 435-8, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26598418

RESUMEN

AIM: Radial artery spasm is common during transradial procedures and is the most common cause of procedural failure. The objectives of this study were to assess whether the routine administration of sedation at the beginning of transradial coronary angiography with the use of hydrophilic-coated and smaller sheaths/catheters would reduce the incidence of radial artery spasm. PATIENTS AND METHODS: Patients undergoing transradial coronary angiography were prospectively randomized to receive midazolam during the procedure or no sedative treatment. The primary endpoint was angiographically confirmed radial artery spasm. Stenosis of the radial artery was measured with a computer-assisted quantification method. RESULTS: In all, 150 patients were randomized into a treatment group and a control group. Spasm occurred in 15 patients of the treatment group (20 %) versus 16 in the control group (21.3 %). There were no differences between the two groups regarding the incidence of spasm and the distribution of spasm severity (p > 0.05). No significant differences were observed between the two groups in terms of 30-day mortality or repeat hospitalization for any cause (p > 0.05). CONCLUSION: Routine use of midazolam could not reduce the occurrence of radial artery spasm during transradial coronary angiography.


Asunto(s)
Cateterismo Periférico/efectos adversos , Sedación Consciente/métodos , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Arteria Radial/efectos de los fármacos , Espasmo/prevención & control , Cateterismo Periférico/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Humanos , Hipnóticos y Sedantes/administración & dosificación , Masculino , Midazolam/administración & dosificación , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espasmo/etiología , Resultado del Tratamiento
5.
Herz ; 40 Suppl 2: 146-50, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25662695

RESUMEN

AIM: The Ceraflex atrial septal defect occluder is an alternative device to the Amplatzer septal occluder with some structural innovations including flexible connection, increased flexibility, and minimized amount of implant material. We evaluated the efficiency and safety of the Ceraflex septal occluder device in percutaneous closure of secundum atrial septal defects. PATIENTS AND METHODS: This was a prospective, nonrandomized, multicenter study of patients undergoing transcatheter closure for an atrial septal defect with the Ceraflex and the Amplatzer septal occluder devices. A clinical evaluation and follow-up transthoracic echocardiography were performed at 1, 6, and 12 months. RESULTS: Between 2010 and 2014, 125 patients underwent atrial septal defect closure with the Ceraflex septal occluder (n = 58) and the Amplatzer septal occluder (n = 67) under transesophageal echocardiography guidance. Patient characteristics, the stretched size of the defect, device size, and fluoroscopy time were similar between the groups. The immediate and follow-up complete occlusion rates for both groups were 100%. There was no device embolization, procedure-related stroke, or pericardial effusion. CONCLUSIONS: The Ceraflex septal occluder is a safe and efficient device for closure of secundum atrial septal defects with no procedural complications. The Ceraflex has similar outcomes when compared with the Amplatzer septal occluder device. The advantage of the Ceraflex septal occluder device is that it can be deployed without the tension of the delivery catheter.


Asunto(s)
Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/cirugía , Complicaciones Posoperatorias/epidemiología , Dispositivo Oclusor Septal/estadística & datos numéricos , Adulto , Causalidad , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Defectos del Tabique Interatrial/epidemiología , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/prevención & control , Factores de Riesgo , Dispositivo Oclusor Septal/clasificación , Resultado del Tratamiento , Turquía/epidemiología
7.
Herz ; 40(3): 528-33, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24441396

RESUMEN

BACKGROUND: Prosthetic valve thrombosis (PVT) is serious complication of valvular replacement surgery, and increased levels of anticardiolipin antibodies (aCL) are associated with thrombosis. The aim of this study was to evaluate the role of aCL in the development of PVT. PATIENTS AND METHODS: We studied the aCL IgM and IgG levels in 114 patients with PVT and 80 healthy patients with prosthetic valves without PVT or a history of thrombosis. All patients underwent detailed transthoracic, transesophageal echocardiographic and clinical examinations. Blood samples were obtained after transesophageal echocardiography. Tests were repeated 12 weeks apart in patients with aCL IgM or IgG positivity. RESULTS: The mean age, sex, presence of atrial fibrillation and cardiovascular risk factors, elapsed time after surgery, and prosthetic valve type and location were similar between patients with PVT and those without. Ineffective anticoagulation was significantly higher among patients with PVT (p < 0.001). The aCL IgM values were significantly higher and positive (> 40 MPL) in the PVT group compared with the control group (10.58 ± 15.90 MPL to 3.70 ± 2.30 MPL, p < 0.001; 7.0 to 0 %, p = 0.016, respectively). The aCL IgG values were significantly higher and positive (> 40 GPL) in the PVT group compared with the control group (12.04 ± 17.58 GPL to 3.83 ± 2.56 GPL, p < 0.001 and 7.9 to 0 %, p = 0.01, respectively). According to international consensus documents, 16 patients had antiphospholipid syndrome. Ineffective anticoagulation and aCL IgM and IgG positivity were independent predictors of PVT in logistic regression analysis (multivariate r(2)= 0.648; p < 0.001, OR= 21.405, 95 %CI= 8.201-55.872; p = 0.008, OR= 1.322, % 95CI= 1.076-1.626; p = 0.005, OR= 1.288, 95 %CI= 1.079-1.538). CONCLUSION: Since the presence of aCL IgM and IgG positivity may cause a tendency toward PVT, these values should be examined in all patients with PVT.


Asunto(s)
Anticuerpos Anticardiolipina/inmunología , Síndrome Antifosfolípido/inmunología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Trombosis/inmunología , Adulto , Biomarcadores/sangre , Estudios Transversales , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Trombosis/diagnóstico , Trombosis/etiología , Resultado del Tratamiento
9.
Herz ; 40(4): 716-21, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25059935

RESUMEN

INTRODUCTION: Inflammation has been reported to be associated with aortic dissection (AD), from the development to the prognosis of AD. In this study we aimed to find the role of the neutrophil-lymphocyte ratio (NLR) in the prediction of clinical events in patients with acute AD type A. PATIENTS AND METHODS: The study comprised 37 patients who were hospitalized at our center between 2009 and 2013 with the diagnosis of acute AD type A. RESULTS: The mean NLR was significantly higher in patients with pericardial effusion than those without effusion (15.6 ± 11.4 vs. 7.5 ± 4.8, p = 0.005). An NLR value > 8.51 yielded an area under the curve (AUC) value of 0.829 [95 % confidence interval (CI) 0.674-0.984, p = 0.004], which demonstrated a sensitivity of 77 % and specificity of 74 % for the prediction of mortality. CONCLUSIONS: The novel inflammatory marker NLR could be used to predict pericardial effusion and in-hospital mortality in patients with acute AD type A.


Asunto(s)
Aneurisma de la Aorta/mortalidad , Disección Aórtica/mortalidad , Disección Aórtica/patología , Mortalidad Hospitalaria , Linfocitos/patología , Neutrófilos/patología , Anciano , Disección Aórtica/sangre , Aneurisma de la Aorta/sangre , Aneurisma de la Aorta/patología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Sensibilidad y Especificidad , Análisis de Supervivencia , Tasa de Supervivencia , Turquía/epidemiología
10.
Perfusion ; 29(3): 275-7, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24335229

RESUMEN

Infective endocarditis (IE) is one of the most dreaded complications of healthcare-associated bloodstream infection. It is an important and potentially lethal complication of medical care and there is incidence evidence of it in this population. We describe a case of concomitant infection of the tricuspid valve and right ventricle free wall after chest tube insertion for spontaneous pneumothorax in a young patient without predisposing diseases.


Asunto(s)
Tubos Torácicos/efectos adversos , Endocarditis/etiología , Neumotórax/cirugía , Válvula Tricúspide , Adulto , Femenino , Humanos
11.
Herz ; 39(4): 534-7, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23828335

RESUMEN

We present the cases of two adult patients with cor triatriatum due to left atrial membrane with atrioventricular septal defect and right atrial membrane. Two-dimensional and real-time three-dimensional transthoracic echocardiography were performed. These noninvasive modalities provided a comprehensive anatomic and hemodynamic evaluation of the anomaly.


Asunto(s)
Corazón Triatrial/diagnóstico por imagen , Corazón Triatrial/cirugía , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Adulto , Anciano , Sistemas de Computación , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA