1.
Phys Med Biol ; 68(21)2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37783213

RESUMEN

Objectives. Transcranial magnetic stimulation (TMS) has been widely used to modulate brain activity in healthy and diseased brains, but the underlying mechanisms are not fully understood. Previous research leveraged biophysical modeling of the induced electric field (E-field) to map causal structure-function relationships in the primary motor cortex. This study aims at transferring this localization approach to spatial attention, which helps to understand the TMS effects on cognitive functions, and may ultimately optimize stimulation schemes.Approach. Thirty right-handed healthy participants underwent a functional magnetic imaging (fMRI) experiment, and seventeen of them participated in a TMS experiment. The individual fMRI activation peak within the right inferior parietal lobule (rIPL) during a Posner-like attention task defined the center target for TMS. Thereafter, participants underwent 500 Posner task trials. During each trial, a 5-pulse burst of 10 Hz repetitive TMS (rTMS) was given over the rIPL to modulate attentional processing. The TMS-induced E-fields for every cortical target were correlated with the behavioral modulation to identify relevant cortical regions for attentional orientation and reorientation.Main results. We did not observe a robust correlation between E-field strength and behavioral outcomes, highlighting the challenges of transferring the localization method to cognitive functions with high neural response variability and complex network interactions. Nevertheless, TMS selectively inhibited attentional reorienting in five out of seventeen subjects, resulting in task-specific behavioral impairments. The BOLD-measured neuronal activity and TMS-evoked neuronal effects showed different patterns, which emphasizes the principal distinction between the neural activity being correlated with (or maybe even caused by) particular paradigms, and the activity of neural populations exerting a causal influence on the behavioral outcome.Significance. This study is the first to explore the mechanisms of TMS-induced attentional modulation through electrical field modeling. Our findings highlight the complexity of cognitive functions and provide a basis for optimizing attentional stimulation protocols.


Asunto(s)
Mapeo Encefálico , Estimulación Magnética Transcraneal , Humanos , Estimulación Magnética Transcraneal/métodos , Imagen por Resonancia Magnética , Encéfalo/fisiología , Atención/fisiología
2.
Psychiatry Res Neuroimaging ; 335: 111718, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37738706

RESUMEN

Insula is considered an important region of the brain in the generation and maintenance of a wide range of psychiatric symptoms, possibly due to being key in fundamental functions such as interoception and cognition in general. Investigating the possibility of targeting this area using non-invasive brain stimulation techniques can open new possibilities to probe the normal and abnormal functioning of the brain and potentially new treatment protocols to alleviate symptoms of different psychiatric disorders. In the current study, COMETS2, a MATLAB based toolbox was used to simulate the magnitude of the current density and electric field in the brain caused by different transcranial direct current stimulation (tDCS) protocols to find an optimum montage to target the insula and its 6 subregions for three different current intensities, namely 2, 3, and 4 mA. Frontal and occipital regions were found to be optimal candidate regions.. The results of the current study showed that it is viable to reach the insula and its individual subregions using tDCS.


Asunto(s)
Trastornos Mentales , Estimulación Transcraneal de Corriente Directa , Humanos , Estimulación Transcraneal de Corriente Directa/métodos , Encéfalo/fisiología , Simulación por Computador , Cognición
3.
Nat Protoc ; 18(2): 293-318, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36460808

RESUMEN

We describe a routine to precisely localize cortical muscle representations within the primary motor cortex with transcranial magnetic stimulation (TMS) based on the functional relation between induced electric fields at the cortical level and peripheral muscle activation (motor-evoked potentials; MEPs). Besides providing insights into structure-function relationships, this routine lays the foundation for TMS dosing metrics based on subject-specific cortical electric field thresholds. MEPs for different coil positions and orientations are combined with electric field modeling, exploiting the causal nature of neuronal activation to pinpoint the cortical origin of the MEPs. This involves constructing an individual head model using magnetic resonance imaging, recording MEPs via electromyography during TMS and computing the induced electric fields with numerical modeling. The cortical muscle representations are determined by relating the TMS-induced electric fields to the MEP amplitudes. Subsequently, the coil position to optimally stimulate the origin of the identified cortical MEP can be determined by numerical modeling. The protocol requires 2 h of manual preparation, 10 h for the automated head model construction, one TMS session lasting 2 h, 12 h of computational postprocessing and an optional second TMS session lasting 30 min. A basic level of computer science expertise and standard TMS neuronavigation equipment suffices to perform the protocol.


Asunto(s)
Corteza Motora , Estimulación Magnética Transcraneal , Estimulación Magnética Transcraneal/métodos , Corteza Motora/fisiología , Electromiografía , Músculo Esquelético , Potenciales Evocados Motores/fisiología , Estimulación Eléctrica
4.
Neuroimage Clin ; 35: 103071, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35671557

RESUMEN

BACKGROUND: Transcranial direct current stimulation (tDCS) is a promising tool to enhance therapeutic efforts, for instance, after a stroke. The achieved stimulation effects exhibit high inter-subject variability, primarily driven by perturbations of the induced electric field (EF). Differences are further elevated in the aging brain due to anatomical changes such as atrophy or lesions. Informing tDCS protocols by computer-based, individualized EF simulations is a suggested measure to mitigate this variability. OBJECTIVE: While brain anatomy in general and specifically atrophy as well as stroke lesions are deemed influential on the EF in simulation studies, the influence of the uncertainty in the change of the electrical properties of the white matter due to white matter lesions (WMLs) has not been quantified yet. METHODS: A group simulation study with 88 subjects assigned into four groups of increasing lesion load was conducted. Due to the lack of information about the electrical conductivity of WMLs, an uncertainty analysis was employed to quantify the variability in the simulation when choosing an arbitrary conductivity value for the lesioned tissue. RESULTS: The contribution of WMLs to the EF variance was on average only one tenth to one thousandth of the contribution of the other modeled tissues. While the contribution of the WMLs significantly increased (p≪.01) in subjects exhibiting a high lesion load compared to low lesion load subjects, typically by a factor of 10 and above, the total variance of the EF didnot change with the lesion load. CONCLUSION: Our results suggest that WMLs do not perturb the EF globally and can thus be omitted when modeling subjects with low to medium lesion load. However, for high lesion load subjects, the omission of WMLs may yield less robust local EF estimations in the vicinity of the lesioned tissue. Our results contribute to the efforts of accurate modeling of tDCS for treatment planning.


Asunto(s)
Accidente Cerebrovascular , Estimulación Transcraneal de Corriente Directa , Sustancia Blanca , Atrofia/patología , Encéfalo/patología , Estimulación Eléctrica , Humanos , Accidente Cerebrovascular/patología , Accidente Cerebrovascular/terapia , Estimulación Transcraneal de Corriente Directa/métodos , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología
5.
Brain Stimul ; 15(2): 509-522, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35248785

RESUMEN

BACKGROUND AND PURPOSE: Previous tDCS studies in chronic stroke patients reported highly inconsistent effects on sensorimotor functions. Underlying reasons could be the selection of different kinematic parameters across studies and for different tDCS setups. We reasoned that tDCS may not simply induce global changes in a beneficial-adverse dichotomy, but rather that different sensorimotor kinematics are differentially affected. Furthermore, the often-postulated higher efficacy of bilateral-dual (bi-tDCS) over unilateral-anodal (ua-tDCS) could not yet be demonstrated consistently either. We investigated the effects of both setups on a wider range of kinematic parameters from standardized robotic tasks in patients with chronic stroke. METHODS: Twenty-four patients with arm hemiparesis received tDCS (20min, 1 mA) concurrent to kinematic assessments in a sham-controlled, cross-over and double-blind clinical trial. Performance was measured on four sensorimotor tasks (reaching, proprioception, cooperative and independent bimanual coordination) from which 30 parameters were extracted. On the group-level, the patterns of changes relative to sham were assessed using paired-samples t-tests and classified as (1) performance increases, (2) decreases and (3) non-significant differences. Correlations between parametric change scores were calculated for each task to assess effects on the individual-level. RESULTS: Both setups induced complex effect patterns with varying proportions of performance increases and decreases. On the group-level, more increases were induced in the reaching and coordination tasks while proprioception and bimanual cooperation were overall negatively affected. Bi-tDCS induced more performance increases and less decreases compared to ua-tDCS. Changes across parameters occurred more homogeneously under bi-tDCS than ua-tDCS, which induced a larger proportion of performance trade-offs. CONCLUSIONS: Our data demonstrate profound tDCS effects on sensorimotor functions post-stroke, lending support for more pronounced and favorable effects of bi-tDCS compared to ua-tDCS. However, no uniformly beneficial pattern was identified. Instead, the modulations varied depending on the task and electrode setup, with increases in certain parameters occurring at the expense of decreases in others.


Asunto(s)
Accidente Cerebrovascular , Estimulación Transcraneal de Corriente Directa , Electrodos , Humanos , Paresia/etiología , Paresia/terapia , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/terapia , Estimulación Transcraneal de Corriente Directa/métodos , Resultado del Tratamiento
6.
PLoS One ; 15(5): e0228119, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32407389

RESUMEN

Simulating transcranial electric stimulation is actively researched as knowledge about the distribution of the electrical field is decisive for understanding the variability in the elicited stimulation effect. Several software pipelines comprehensively solve this task in an automated manner for standard use-cases. However, simulations for non-standard applications such as uncommon electrode shapes or the creation of head models from non-optimized T1-weighted imaging data and the inclusion of irregular structures are more difficult to accomplish. We address these limitations and suggest a comprehensive workflow to simulate transcranial electric stimulation based on open-source tools. The workflow covers the head model creation from MRI data, the electrode modeling, the modeling of anisotropic conductivity behavior of the white matter, the numerical simulation and visualization. Skin, skull, air cavities, cerebrospinal fluid, white matter, and gray matter are segmented semi-automatically from T1-weighted MR images. Electrodes of arbitrary number and shape can be modeled. The meshing of the head model is implemented in a way to preserve the feature edges of the electrodes and is free of topological restrictions of the considered structures of the head model. White matter anisotropy can be computed from diffusion-tensor imaging data. Our solver application was verified analytically and by contrasting the tDCS simulation results with that of other simulation pipelines (SimNIBS 3.0, ROAST 3.0). An agreement in both cases underlines the validity of our workflow. Our suggested solutions facilitate investigations of irregular structures in patients (e.g. lesions, implants) or new electrode types. For a coupled use of the described workflow, we provide documentation and disclose the full source code of the developed tools.


Asunto(s)
Encéfalo/fisiología , Sistema Nervioso Central/fisiología , Cabeza/fisiología , Estimulación Transcraneal de Corriente Directa , Algoritmos , Anisotropía , Encéfalo/diagnóstico por imagen , Encéfalo/efectos de la radiación , Sistema Nervioso Central/diagnóstico por imagen , Sistema Nervioso Central/efectos de la radiación , Imagen de Difusión Tensora , Sustancia Gris/diagnóstico por imagen , Sustancia Gris/efectos de la radiación , Cabeza/diagnóstico por imagen , Cabeza/efectos de la radiación , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Modelos Teóricos , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/efectos de la radiación , Flujo de Trabajo
7.
Front Aging Neurosci ; 11: 264, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31611782

RESUMEN

BACKGROUND: Proprioception is a prerequisite for successful motor control but declines throughout the lifespan. Brain stimulation techniques such as anodal transcranial direct current stimulation (a-tDCS) are capable of enhancing sensorimotor performance across different tasks and age groups. Despite such growing evidence for a restorative potential of tDCS, its impact on proprioceptive accuracy has not been studied in detail yet. OBJECTIVE: This study investigated online effects of a-tDCS over S1 on proprioceptive accuracy in young (YA) and old healthy adults (OA). METHODS: The effect of 15 min of a-tDCS vs. sham on proprioceptive accuracy was assessed in a cross-over, double blind experiment in both age groups. Performance changes were tested using an arm position matching task in a robotic environment. Electrical field (EF) strengths in the target area S1 and control areas were assessed based on individualized simulations. RESULTS: a-tDCS elicited differential changes in proprioceptive accuracy and EF strengths in the two groups: while YA showed a slight improvement, OA exhibited a decrease in performance during a-tDCS. Stronger EF were induced in target S1 and control areas in the YA group. However, no relationship between EF strength and performance change was found. CONCLUSION: a-tDCS over S1 elicits opposing effects on proprioceptive accuracy as a function of age, a result that is important for future studies investigating the restorative potential of a-tDCS in healthy aging and in the rehabilitation of neurological diseases that occur at advanced age. Modeling approaches could help elucidate the relationship between tDCS protocols, brain structure and performance modulation.

8.
Magn Reson Med ; 81(3): 2090-2105, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30230021

RESUMEN

PURPOSE: Simulating the interaction of the human body with electromagnetic fields is an active field of research. Individualized models are increasingly being used, as anatomical differences affect the simulation results. We introduce a processing pipeline for creating individual surface-based models of the human head and torso for application in simulation software based on unstructured grids. The pipeline is designed for easy applicability and is publicly released on figshare. METHODS: The pipeline covers image acquisition, segmentation, generation of segmentation masks, and surface mesh generation of the single, external boundary of each structure of interest. Two gradient-echo sequences are used for image acquisition. Structures of the head and body are segmented using several atlas-based approaches. They consist of bone/skull, subarachnoid cerebrospinal fluid, gray matter, white matter, spinal cord, lungs, the sinuses of the skull, and a combined class of all other structures including skin. After minor manual preparation, segmentation images are processed to segmentation masks, which are binarized images per segmented structure free of misclassified voxels and without an internal boundary. The proposed workflow is applied to 2 healthy subjects. RESULTS: Individual differences of the subjects are well represented. The models are proven to be suitable for simulation of the RF electromagnetic field distribution. CONCLUSION: Image segmentation, creation of segmentation masks, and surface mesh generation are highly automated. Manual interventions remain for preparing the segmentation images prior to segmentation mask generation. The generated surfaces exhibit a single boundary per structure and are suitable inputs for simulation software.


Asunto(s)
Encéfalo/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Torso/diagnóstico por imagen , Adulto , Algoritmos , Líquido Cefalorraquídeo/diagnóstico por imagen , Simulación por Computador , Campos Electromagnéticos , Sustancia Gris/diagnóstico por imagen , Voluntarios Sanos , Humanos , Masculino , Reconocimiento de Normas Patrones Automatizadas , Fantasmas de Imagen , Lenguajes de Programación , Piel/diagnóstico por imagen , Cráneo/diagnóstico por imagen , Programas Informáticos , Médula Espinal/diagnóstico por imagen , Sustancia Blanca/diagnóstico por imagen , Adulto Joven