Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Pediatr Cardiol ; 26(4): 431-9, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15549617

RESUMEN

We report our experience with the use of covered stents for the management of coarctation of the aorta. From December 2001 to March 2004, nine patients (seven males; median age, 31 years; mean weight, 65 +/- 15 kg) underwent implantation. Indications included critical or atretic native coarctation (n = 4), patients >50 years of age (n = 2), associated patent ductus arteriosus (n = 1) or adjacent aneurysm (n = 1), and the presence of a circumferential fracture within a previously implanted stent (n = 1). The covered balloon-expandable Cheatham-Platinum stent and the self-expandable stent graft Braile were employed. Adequate implantation was observed in all patients. Gradients were reduced from 54 +/- 14 to 3 +/- 8 mmHg and the coarctation site increased from 2.4 +/- 2.9 to 15.9 +/- 4.3 mm. The patent ductus arteriosus was immediately closed and the aneurysm excluded. Two patients >35 years with aneurysmal ascending aorta and metallic aortic prosthesis had aneurysm formation at follow-up, with one undergoing aneurysm exclusion using a Braile stent. Although covered stents are useful in the management of selected patients with coarctation, aneurysm formation may still occur in patients with markers of aortic wall weakness. Refinements in the deployment technique and/or the stent design are needed to eliminate this risk.


Asunto(s)
Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Materiales Biocompatibles Revestidos , Politetrafluoroetileno , Stents , Adolescente , Adulto , Anciano , Coartación Aórtica/diagnóstico por imagen , Aortografía , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
3.
Cardiol Young ; 9(4): 371-6, 1999 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10476826

RESUMEN

In this report, we describe our experience with transcatheter occlusion of congenital coronary arterial fistulas in adults. From November 1992 to November 1996, 5 symptomatic patients, aged from 47 to 70 years, underwent transcatheter occlusion of fistulas using a retrograde arterial approach. All had chest pain or dyspnea on exertion. Detachable balloons were used in 4 patients, and Gianturco coils in 1. Detachable balloons were implanted through a Debrun system, while the coils were implanted through a 5 French right coronary Judkins catheter. Both were passed through an 8 French guiding catheter (Amplatz II). Each patient had a single fistula. The fistulas originated from the right coronary artery in 3 patients, and from the circumflex artery in 2. They drained into the pulmonary trunk in 3 patients, into the right atrium in 1, and into a bronchial artery in the other. All fistulas were occluded completely in the catheterization laboratory, and the procedures were uncomplicated. At follow up, 3 patients underwent coronary angiography, and there was no evidence of recanalization. Transcatheter embolization in adults of single congenital coronary fistulas with detachable balloons and coils is safe and effective and can be regarded as an acceptable alternative to surgery.


Asunto(s)
Fístula Arterio-Arterial/terapia , Anomalías de los Vasos Coronarios/terapia , Embolización Terapéutica , Anciano , Cateterismo Cardíaco , Angiografía Coronaria , Embolización Terapéutica/métodos , Atrios Cardíacos/anomalías , Humanos , Persona de Mediana Edad , Arteria Pulmonar/anomalías
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...