Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Cardiol Cases ; 27(3): 93-96, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36910038

RESUMEN

A 56-year-old man presented with fever, cough, and bloody sputum. He had undergone mitral valve replacement with mechanical prosthesis 14 months prior for mitral valve disease. Subsequently, the patient was taking warfarin and amiodarone. Chest imaging revealed dense, infiltrative shadows, and blood tests showed prolonged prothrombin time and eosinophilia. Warfarin was withdrawn, and antibiotics were started, but bloody sputum and respiratory failure persisted. Considering that eosinophilia was observed after the administration of amiodarone, the drug was discontinued, and bronchoalveolar lavage was performed. Cytology showed foam cells, eosinophils, and hemosiderin-laden macrophages; amiodarone-induced diffuse alveolar hemorrhage (DAH) and acute eosinophilic pneumonia (AEP) were diagnosed, and the patient was treated with corticosteroids. This report describes the first documented case of amiodarone-induced DAH and AEP. When a patient taking amiodarone presents with antibiotic-refractory pneumonia with bloody sputum and eosinophilia, amiodarone-induced DAH and AEP should be considered. Learning objective: We report the first case of amiodarone-induced diffuse alveolar hemorrhage (DAH) and acute eosinophilic pneumonia (AEP) diagnosed by foam cells, eosinophils, and hemosiderin-laden macrophages on bronchoalveolar lavage cytology. When a patient taking amiodarone presents with antibiotic-refractory pneumonia with bloody sputum and eosinophilia, amiodarone-induced DAH and AEP should be considered.

2.
Circ J ; 87(6): 783-790, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-36990778

RESUMEN

BACKGROUND: Angiographic fractional flow reserve (angioFFR) is a novel artificial intelligence (AI)-based angiography-derived fractional flow reserve (FFR) application. We investigated the diagnostic accuracy of angioFFR to detect hemodynamically relevant coronary artery disease.Methods and Results: Consecutive patients with 30-90% angiographic stenoses and invasive FFR measurements were included in this prospective, single-center study conducted between November 2018 and February 2020. Diagnostic accuracy was assessed using invasive FFR as the reference standard. In patients undergoing percutaneous coronary intervention, gradients of invasive FFR and angioFFR in the pre-senting segments were compared. We assessed 253 vessels (200 patients). The accuracy of angioFFR was 87.7% (95% confidence interval [CI] 83.1-91.5%), with a sensitivity of 76.8% (95% CI 67.1-84.9%), specificity of 94.3% (95% CI 89.5-97.4%), and area under the curve of 0.90 (95% CI 0.86-0.93%). AngioFFR was well correlated with invasive FFR (r=0.76; 95% CI 0.71-0.81; P<0.001). The agreement was 0.003 (limits of agreement: -0.13, 0.14). The FFR gradients of angioFFR and invasive FFR were comparable (n=51; mean [±SD] 0.22±0.10 vs. 0.22±0.11, respectively; P=0.87). CONCLUSIONS: AI-based angioFFR showed good diagnostic accuracy for detecting hemodynamically relevant stenosis using invasive FFR as the reference standard. The gradients of invasive FFR and angioFFR in the pre-stenting segments were comparable.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Estudios Prospectivos , Estenosis Coronaria/diagnóstico por imagen , Inteligencia Artificial , Angiografía Coronaria/métodos , Índice de Severidad de la Enfermedad , Valor Predictivo de las Pruebas
3.
Circ J ; 85(11): 2043-2049, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-34148928

RESUMEN

BACKGROUND: Myocardial perfusion imaging (MPI) and fractional flow reserve (FFR) are established approaches to the assessment of myocardial ischemia. Recently, various FFR cutoff values were proposed, but the diagnostic accuracy of MPI in identifying positive FFR using various cutoff values is not well established.Methods and Results:We retrospectively studied 273 patients who underwent stress MPI and FFR within a 3-month period. Results for FFR were obtained from 218 left anterior descending artery (LAD) lesions and 207 non-LAD lesions. Stress MPI and FFR demonstrated a good correlation in the detection of myocardial ischemia. However, the positive predictive value (PPV) of FFR for detecting MPI-positive lesions at the optimal FFR thresholds was insufficient (44% for LAD and 65% for non-LAD lesions). This was caused by a sharp drop in PPV at an FFR threshold of 0.7 or more. Notably, 41% of the lesions with normal MPI demonstrated FFRs <0.80. However, MPI-negative lesions had an extremely low lesion rate with FFR <0.65 (6%). Conversely, 78% and 41% of MPI-positive lesions had FFR <0.80 and <0.65, respectively. CONCLUSIONS: The data confirmed that decisions based on MPI are reasonable because MPI-negative patients have an extremely low rate of lesions with a FFR below the cutoff point for a hard event, and MPI-positive lesions include many lesions with FFR <0.65.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Imagen de Perfusión Miocárdica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
4.
Cardiovasc Interv Ther ; 36(1): 74-80, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32048184

RESUMEN

The diastolic pressure ratio (dPR) and resting full-cycle ratio (RFR) are considered to be almost identical to the instantaneous wave-free ratio (iFR) in the retrospective analysis of pooled data. The aim of this study was to investigate the direct comparison of iFR and these new resting indexes in real world practice. Two pressure wires were inserted and placed in the distal part of the same coronary artery. The measurement of the iFR and the other resting indexes was performed simultaneously. A total of 54 lesions from 23 patients were subject to physiological study. In 49 lesions, iFR and other resting indexes were also measured in hyperemic conditions. The general correlation between iFR and other resting indexes was excellent in both resting and hyperemic conditions (r2 = 0.99; mean difference - 0.001 ± 0.021; p < 0.001; and r2 = 0.99; mean difference - 0.012 ± 0.025; p < 0.001, respectively). This correlation was maintained in various subgroup analyses. A diagnostic change between iFR and other resting indexes occurred in three cases (3%) when a fixed cut-off point (≤ 0.89) was applied. There was no diagnostic change when a hybrid zone (0.86 ≤ iFR ≤ 0.93) was considered. The new resting indexes and iFR showed very high correlation in real world practice. A diagnostic change only occurred in three cases (3%) when a fixed cut-off point (≤ 0.89) was applied.


Asunto(s)
Presión Sanguínea/fisiología , Estenosis Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Descanso/fisiología , Anciano , Cateterismo Cardíaco , Angiografía Coronaria , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Diástole , Femenino , Humanos , Masculino , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
5.
JACC Cardiovasc Interv ; 13(22): 2688-2698, 2020 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-33129819

RESUMEN

OBJECTIVES: The aim of this study was to investigate the accuracy of pre-percutaneous coronary intervention (PCI) predicted nonhyperemic pressure ratios (NHPRs) with actual post-PCI NHPRs and to assess the efficacy of PCI strategy using pre-PCI NHPR pullback. BACKGROUND: Predicting the functional results of PCI is feasible using pre-PCI longitudinal vessel interrogation with the instantaneous wave-free ratio (iFR), a pressure-based, adenosine-free NHPR. However, the reliability of novel NHPRs (resting full-cycle ratio [RFR] and diastolic pressure ratio [dPR]) for this purpose remains uncertain. METHODS: In this prospective, multicenter, randomized controlled trial, vessels were randomly assigned to receive pre-PCI iFR, RFR, or dPR pullback (50 vessels each). The pre-PCI predicted NHPRs were compared with actual NHPRs after contemporary PCI using intravascular imaging. The number and the total length of treated lesions were compared between NHPR pullback-guided and angiography-guided strategies. RESULTS: The predicted NHPRs were strongly correlated with actual NHPRs: iFR, r = 0.83 (95% confidence interval: 0.72 to 0.90; p < 0.001); RFR, r = 0.84 (95% confidence interval: 0.73 to 0.91; p < 0.001), and dPR, r = 0.84 (95% confidence interval: 0.73 to 0.91; p < 0.001). The number and the total length of treated lesions were lower with the NHPR pullback strategy than with the angiography-guided strategy, leading to physiological improvement. CONCLUSIONS: Predicting functional PCI results on the basis of pre-procedural RFR and dPR pullbacks yields similar results to iFR. Compared with an angiography-guided strategy, a pullback-guided PCI strategy with any of the 3 NHPRs reduced the number and the total length of treated lesions. (Study to Examine Correlation Between Predictive Value and Post PCI Value of iFR, RFR and dPR; UMIN000033534).


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Cateterismo Cardíaco , Angiografía Coronaria , Vasos Coronarios , Humanos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Resultado del Tratamiento
6.
Circ Cardiovasc Interv ; 13(11): e009314, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33106049

RESUMEN

BACKGROUND: Given the characteristic differences between intravascular ultrasound (IVUS) and optical frequency domain imaging (OFDI), their approach to therapeutic guidance during percutaneous coronary interventions (PCIs) and arterial healing response after stenting may also vary. METHODS: MISTIC-1 (The Multimodality Imaging Study in Cardiology cohort 1) is a multicenter, randomized-controlled, noninferiority trial that compared imaging end points between OFDI- and IVUS-guided PCI. Patients with stable coronary artery disease were randomly assigned to either OFDI- or IVUS-guided PCI using a Biolimus A9-eluting stent according to a prespecified protocol for imaging guidance. Stent sizing was based on external elastic lamina in IVUS-guided PCI while lumen up-size in OFDI-guided PCI. Postprocedural OFDI was investigated regardless of randomization, while operators in IVUS-guided PCI arm were blinded to the images. The primary end point was in-segment minimum lumen area assessed using OFDI at 8 months, while the secondary end point was a composite of cardiovascular mortality, target-vessel myocardial infarction, or target-lesion revascularization (device-oriented composite end point). Patients were followed up to 3 years after the index procedure. RESULTS: A total of 109 patients (mean age 70 years, male 78%) with 126 lesions were enrolled. Postprocedural minimum stent area was 6.31±1.89 and 6.72±2.08 mm2 in OFDI and IVUS group, respectively (P=0.26). At the 8-month follow-up, in-segment minimum lumen area was 4.56±1.94 and 4.13±1.86 mm2 in OFDI and IVUS group, respectively (Pnon-inferiority <0.001). Both groups had comparable neointimal healing score (median 0.16 [interquartile range, 0.00-3.14] versus 0.90 [0.00-3.30], respectively; P=0.43). The incidence rate of device-oriented composite end point at 3 years was 7.4% and 7.3% in OFDI and IVUS group, respectively (hazard ratio, 1.05 [95% CI, 0.26-4.18]; P=0.95). CONCLUSIONS: OFDI-guided PCI was not inferior to IVUS-guided PCI in terms of in-segment minimum lumen area at 8 months. Although a small sample size was acknowledged, OFDI could be an alternative to IVUS when considering intracoronary imaging-guided PCI in selected populations with coronary artery diseases. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03292081.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Japón , Masculino , Neointima , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
8.
J Interv Card Electrophysiol ; 58(3): 289-297, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31367961

RESUMEN

PURPOSE: Cryoenergy has been demonstrated to be a safe alternative to radiofrequency ablation for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT). This study aimed to evaluate the safety and efficacy of cryoablation in patients with AVNRT. METHODS: A multicenter retrospective study was performed. Two hundred eighty-three consecutive patients with AVNRT underwent cryoablation. Cryomapping at - 30 °C and - 80 °C was performed to predict cryoablation outcome and ascertain antegrade conduction. Cryoenergy was delivered subsequently at the same spot (cryoablation at - 80 °C) for 240 s. RESULTS: Ablation procedure was acutely successful in 281 out of 283 patients (99.3%). Of note, 22 patients (10.1%) had transient AV block during the cryoablation, but no injurious effects on AV conduction were provoked during cryomapping. During a follow-up period of 367 ± 35 days, the recurrence rate was 3.9% (11 out of 281). There were no significant differences among the patients with a complete elimination of slow pathway conduction, AH jump without an echo beat, and AH jump with a single echo beat, in terms of the long-term recurrence of AVNRT. CONCLUSIONS: Cryoablation of AVNRT appears to be effective both acutely and during the long-term with a minimal risk of unwanted injuries to the conduction system. It seems to be important to monitor the antegrade conduction during cryoenergy applications, even when cryomapping demonstrates a safe location for cryoablation. The recurrence rate of AVNRT did not differ according to the properties of the residual slow pathway conduction.


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Japón/epidemiología , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 94(7): 947-955, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31025511

RESUMEN

OBJECTIVES: We sought to examine associations between plaque characteristics by intravascular ultrasound (IVUS) and detectability of external elastic lamina (EEL) by optical frequency domain imaging (OFDI) in human coronary arteries. BACKGROUND: It is often challenging to detect EEL which represents vessel size by light-based imaging modalities due to light intensity attenuation through atherosclerotic plaque. METHODS: IVUS and OFDI prior to stent implantation were sequentially investigated per protocol. We identified corresponding cross-sections by minimum lumen area (MLA) or just distally to side branches as anatomical landmarks. Plaque characterization was determined by integrated backscatter IVUS analysis. We categorized detectable EEL arc by OFDI into four groups: 0≤ and <1 quadrant (group 1), 1≤ and <2 quadrants (group 2), 2≤ and <3 quadrants (group 3), or 3≤ and <4 quadrants (group 4). RESULTS: We prospectively studied 103 vessels in 93 patients with stable coronary artery disease. Corresponding 711 cross-sections were analyzed. Cross-sections with detectable EEL arc <2 quadrants (group 1 or 2) were observed in 86.1% of MLA sites but only in 29.3% of non-MLA sites (p < .05). Percentage plaque area (%PA) appeared to be the strongest predictor to detect EEL arc <2 quadrants with the cut-off of 60.3% (AUC 0.90; sensitivity 79.8%, specificity 85.5%). Lipid pool and calcification remained statistically significant in predicting detectable EEL arc <2 quadrants after adjustment with %PA. CONCLUSIONS: Presence of large plaque burden, lipid pool, and calcification significantly predicts the detectability of EEL by OFDI assessment. Locations with detectable EEL arc <2 quadrants should thus be avoided for optimal stent landing zone.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Placa Aterosclerótica , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Puntos Anatómicos de Referencia , Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Japón , Masculino , Intervención Coronaria Percutánea/instrumentación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Dispersión de Radiación , Stents
10.
Catheter Cardiovasc Interv ; 94(2): E61-E66, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-30723996

RESUMEN

OBJECTIVES: The objective was to evaluate the safety, feasibility, and accuracy of the jailed-pressure wire technique using a durable optical fiber-based pressure wire with high-pressure dilatation using a non-compliant balloon after main vessel stenting. BACKGROUND: Fractional flow reserve (FFR) information can help interventionists determine whether they should treat a jailed-side branch (SB). However, re-crossing a pressure wire into a jailed-SB is sometimes technically difficult. METHODS: Fifty-one consecutive lesions from 48 patients who underwent the jailed-pressure wire technique were retrospectively investigated. The primary endpoint was complication rate and secondary endpoints included success rate of FFR measurement, incidence of wire disruption, and final drift rate. The usability of FFR for percutaneous coronary intervention of coronary bifurcation lesion was also evaluated. RESULTS: Median age of the patients was 69 years and 80.4% were men. The most frequent underlying disease was stable angina (70.6%) and 68.6% were type B2 lesions. Our main findings were: the procedure was performed successfully in all cases without any complications or wire disruption, FFR could be measured without significant final drift in 95.9% of cases, and FFR measurements helped interventionists determine whether to perform a final kissing balloon dilatation in 49.0% cases. CONCLUSIONS: The jailed-pressure wire technique using a durable optical fiber-based pressure wire with high-pressure post-dilatation maneuver was safe, feasible, and accurate.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Enfermedad de la Arteria Coronaria/terapia , Tecnología de Fibra Óptica/instrumentación , Fibras Ópticas , Transductores de Presión , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Cateterismo Cardíaco/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Diseño de Equipo , Estudios de Factibilidad , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento
11.
Circ J ; 82(11): 2837-2844, 2018 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-30175800

RESUMEN

BACKGROUND: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress 99 mTc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest 99 mTc-tetrofosmin/stress 201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera.Methods and Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. CONCLUSIONS: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.


Asunto(s)
Angiografía Coronaria , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica , Compuestos Organofosforados/administración & dosificación , Compuestos de Organotecnecio/administración & dosificación , Radioisótopos de Talio/administración & dosificación , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Anciano de 80 o más Años , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
Pacing Clin Electrophysiol ; 41(4): 376-382, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29380388

RESUMEN

BACKGROUND: Cryoballoon (CB) applications to pulmonary veins (PVs) can cause stenosis just as radiofrequency (RF) energy deliveries. The goal of the present study was to clarify whether or not there was any difference in the extent of acute or chronic PV narrowing after PV isolation between the two different energy sources. METHODS: Consecutive patients with paroxysmal atrial fibrillation who were scheduled to undergo a PV isolation were randomized 1:1 to receive CB or RF ablation. The endpoints were any acute PV narrowing assessed with the use of intracardiac ultrasound during the procedure and PV stenosis measured with cardiac computed tomography at the 3-month follow-up. RESULTS: An acute reduction in the luminal area of the left superior PV (mean ± standard deviation, -6.8 ± 8.7 vs -19.9 ± 14.7%; P < 0.001) and left inferior PV (-5.1 ± 20.2 vs -15.3 ± 11.6%; P = 0.03) was significantly smaller in the CB arm (N = 25) than the RF arm (N = 25). There was no difference in the extent of PV stenosis 3 months after the ablation between the arms (0-25% stenosis, 90% vs 88%, 25-50% stenosis, 10% vs 12%, >50% stenosis, both 0%; P = 0.82). A greater acute PV narrowing was likely to lead to chronic stenosis in the RF arm (P = 0.004). CONCLUSIONS: CB ablation may reduce the acute narrowing of the left-sided PVs as compared to RF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Ablación por Radiofrecuencia/efectos adversos , Estenosis de Vena Pulmonar/etiología , Enfermedad Aguda , Anciano , Enfermedad Crónica , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Estenosis de Vena Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X
13.
J Cardiol ; 71(5): 458-463, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29203079

RESUMEN

BACKGROUND: Instantaneous wave-free ratio (iFR) has the potential to improve the accuracy of the prediction of the physiological result of percutaneous coronary intervention (PCI). The aim of this study was to evaluate the accuracy of iFR to predict the final physiological results following PCI, and investigate the factors for failed prediction. METHODS: In 73 lesions, iFR pullback recordings were measured and comparisons were made between the predicted improvement following PCI and the observed result. RESULTS: iFR predicted-observed difference was 0.036±0.037. Multivariate analysis showed residual iFR pressure gradient across the implanted stent (odds ratio, 2.329; 95% confidence interval, 1.408-3.853; p=0.0010) as an independent risk factor for error in iFR prediction. CONCLUSIONS: iFR predicted-observed difference was 0.036±0.037. Residual in-stent iFR pressure gradient following PCI is the only independent risk factor for failed prediction.


Asunto(s)
Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Anciano , Cateterismo Cardíaco , Angiografía Coronaria , Vasos Coronarios/patología , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Presión , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
14.
Cardiovasc Interv Ther ; 33(3): 270-276, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28674929

RESUMEN

The frequency of a large pressure signal drift (PDs) caused by pressure wire using optical fibers and its effect on fractional flow reserve (FFR)-based decision-making is not clear. We used pressure wires using optical fibers as "workhorse wires" for 95 consecutive lesions. The wire was normalized at the tip of the guiding catheter just before performing the percutaneous coronary intervention (PCI) and was used without re-normalization until the end of the PCI. The drift value at the end of the procedures was evaluated. Four per cent (n = 4) of patients showed a large drift (PD >3 mmHg). Classification discordance between read-out and PD-corrected FFR values was detected in 8 (8%) measurements in total. The decision changed from FFR ≤0.80 to >0.80 in 7 (7%) measurements and vice versa in 1 (1%) measurement. PD showed no effect on decision-making when the FFR read-out value was <0.78 or >0.82. The frequency of large drifts caused by pressure wires using optical fibers was 4%. However, no case showed decision changes when the FFR gray zone was considered.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico/fisiología , Fibras Ópticas/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Anciano , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/cirugía , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos
15.
Circ Cardiovasc Interv ; 10(12)2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29246913

RESUMEN

BACKGROUND: Postocclusional hyperemia caused by balloon occlusion is a potential alternative method of inducing hyperemia for measuring post-percutaneous coronary intervention fractional flow reserve (FFR). The aim of this study was to investigate postocclusional hyperemia as a method of inducing hyperemia. METHODS AND RESULTS: FFR measured by postocclusional hyperemia (FFRoccl) caused by balloon occlusion after percutaneous coronary intervention was compared with FFR measured by drug-induced hyperemia (FFR measured by intravenous ATP; and FFR measured by intracoronary papaverine injection [FFRpap]) in 98 lesions from 98 patients. The hyperemia duration was also measured for FFRoccl and FFRpap. The correlation coefficient between FFRoccl, FFR measured by intravenous ATP (r=0.973; P<0.01), and FFRpap (r=0.975; P<0.01) showed almost identical values to those obtained for the correlation coefficient between FFR measured by intravenous ATP and FFRpap (r=0.967; P<0.01). No clear difference was observed on Bland-Altman analysis. Hyperemia duration was significantly longer with FFRoccl than with FFRpap (70±22 versus 51±25 s; P<0.01). CONCLUSIONS: Strong correlations were found between FFRoccl and FFR measured by intravenous ATP and FFRoccl and FFRpap. Hyperemia caused by FFRoccl was significantly longer than that caused by FFRpap.


Asunto(s)
Oclusión con Balón , Enfermedad de la Arteria Coronaria/terapia , Reserva del Flujo Fraccional Miocárdico , Hiperemia/fisiopatología , Intervención Coronaria Percutánea , Adenosina Trifosfato/administración & dosificación , Administración Intravenosa , Anciano , Anciano de 80 o más Años , Oclusión con Balón/efectos adversos , Cateterismo Cardíaco , Circulación Colateral , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Stents Liberadores de Fármacos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Papaverina/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Resultado del Tratamiento , Vasodilatadores/administración & dosificación
16.
J Phys Chem B ; 119(11): 4284-93, 2015 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-25697812

RESUMEN

The property development of the ethylene-tetrafluoroethylene copolymer (ETFE) membrane induced by simultaneous biaxial drawing was investigated. Commonly, tensile strength can be increased by drawing; conversely, tear resistance decreases. In this study, the balance between tensile strength and tear resistance for the resultant ETFE membrane was optimized achieved by a combination of lamination of low molecular weight (LMW) and high molecular weight (HMW) layers and subsequent biaxial drawing. The structural factor determining tear resistance of these biaxially drawn membranes was determined based on in situ small-angle X-ray scattering (SAXS) measurement during tensile deformation simulating tearing tests. Lozenge shaped scattering, which indicated inclined lamellae, was observed during such tensile deformation of the resultant membranes. Remarkably, this inclined lamellar structure was observed for the pure LMW membrane; however, it also appeared at the interface between LMW and HMW layers within biaxially drawn membranes. For the membrane exhibiting the highest tearing strength, the fraction of such inclined lamella increased up to the critical strain corresponding to the actual sample breaking. These results confirm that the inclined lamellar structure absorbed strain during membrane tearing.

17.
Sleep Med ; 14(7): 622-7, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23719478

RESUMEN

BACKGROUND: Sleep-disordered breathing (SDB) frequently is induced by sedation during ablation of atrial fibrillation (AF). We tested whether or not sedative-induced SDB is associated with clinical sleep apnea syndrome (SAS). METHODS: We examined SDB observed during intra-ablation sedation with a novel portable respiratory monitor (PM), SD-101, in 140 patients undergoing AF ablation without any known SAS. A sleep study was repeated the next night of the ablation with the simultaneous use of the SD-101 and type 3 PM, APNOMONITOR V. RESULTS: The respiratory disturbance index (RDI) during sedation (20.0±7.8 events/h) was significantly correlated with the RDI measured by the SD-101 during the night (15.8±13.7 events/h; r=0.50) and the RDI assessed by the APNOMONITOR V during the night (12.7±12.3 events/h; r=0.55). An excellent agreement was found between the RDIs simultaneously measured with the 2 PMs (intraclass correlation coefficient, 0.84), especially for an RDI of ≥30 events/h (κ statistic value, 0.82). The area under the receiver-operating characteristic curve for the RDI with the use of the SD-101 during sedation to identify the patients with an RDI of ≥30 events/h by both PMs during the night was 0.92. A left atrial diameter of >40 mm (odds ratio [OR], 4.10) and an RDI during sedation of >20 events/h (OR, 17.75) were independently associated with having an RDI of ≥30 events/h with both PMs during the night. CONCLUSIONS: Frequent episodes of sedative-induced SDB may have a diagnostic value for SAS in patients with AF.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Hipnóticos y Sedantes/efectos adversos , Monitoreo Fisiológico/métodos , Síndromes de la Apnea del Sueño/inducido químicamente , Síndromes de la Apnea del Sueño/diagnóstico , Anciano , Femenino , Humanos , Hipnóticos y Sedantes/administración & dosificación , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/normas , Curva ROC , Mecánica Respiratoria , Sueño/efectos de los fármacos , Síndromes de la Apnea del Sueño/fisiopatología
18.
Pacing Clin Electrophysiol ; 36(2): 172-9, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23121681

RESUMEN

BACKGROUND: We aimed to evaluate the feasibility of an oral direct thrombin inhibitor, dabigatran, as a periprocedural anticoagulant for use with ablation of atrial fibrillation (AF). METHODS: Consecutive patients scheduled to undergo an AF ablation were randomly assigned to receive dabigatran (n = 45) or warfarin (n = 45) to compare their clinical feasibility. Both of those oral anticoagulants were discontinued the day before the ablation and were resumed after confirming hemostasis of the venipuncture site. A bridging therapy with heparin was not used in either of the patient groups. RESULTS: Dabigatran was switched to warfarin before the ablation because of dyspepsia in three patients. An occurrence of rebleeding from the venipuncture site was less common in dabigatran-allocated patients than in warfarin-allocated patients (20% vs 44%; P = 0.013). The reduction in the D-dimer level after the initiation of oral anticoagulants was greater in the dabigatran-allocated patients than in the warfarin-allocated patients. The time from the initiation of the anticoagulants to the ablation was significantly shorter in the dabigatran-allocated patients than in the warfarin-allocated patients (43 ± 7 vs 63 ± 13 days; P < 0.0001). There was only one fatal periprocedural complication in a patient receiving warfarin, who had a mesenteric arterial thrombosis after the ablation. CONCLUSIONS: An anticoagulation strategy with dabigatran may surpass that with warfarin in reducing both the periprocedural risk of minor bleeding and a hypercoagulable state, and the time to ablation in patients undergoing ablation of AF.


Asunto(s)
Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Bencimidazoles/administración & dosificación , Premedicación/métodos , Trombosis/etiología , Trombosis/prevención & control , Warfarina/administración & dosificación , beta-Alanina/análogos & derivados , Anticoagulantes/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Dabigatrán , Femenino , Humanos , Masculino , Persona de Mediana Edad , Atención Perioperativa/métodos , Resultado del Tratamiento , beta-Alanina/administración & dosificación
19.
Chemistry ; 18(50): 16129-35, 2012 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-23138931

RESUMEN

Facile synthesis of meso-aryl-substituted 5,15-dithiaporphyrins and 10-thiacorroles has been achieved by sulfidation of α,α'-dichlorodipyrrin metal complexes with sodium sulfide in DMF. Thiacorrole metal complexes exhibit distinct aromaticity due to 18 π-conjugation including the lone pair on sulfur, whereas dithiaporphyrins are nonaromatic judging from (1)H NMR spectra, X-ray analysis, and absorption spectra. We have found that Ni(II) and Al(III) dithiaporphyrin complexes undergo smooth thermal sulfur extrusion reaction to give the corresponding thiacorrole complexes, whereas free base, Zn(II), Pd(II), and Pt(II) dithiaporphyrin complexes did not exhibit the similar reactivity. The DFT calculations have elucidated a reaction pathway involving an episulfide intermediate, which can explain the markedly different reactivity among dithiaporphyrin metal complexes.

20.
J Cardiovasc Electrophysiol ; 23(12): 1289-94, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22913591

RESUMEN

INTRODUCTION: It is not common for patients on chronic hemodialysis (HD) to undergo catheter ablation of atrial fibrillation (AF). We aimed to show the outcomes of AF ablation in the HD patients. METHODS AND RESULTS: Thirty HD patients who underwent pulmonary vein (PV) isolation for drug refractory paroxysmal AF were retrospectively studied, and their AF recurrence free rate and frequency of periprocedural complications were compared to 60 age- and gender-matched control patients not requiring HD. A nonirrigated ablation catheter was used in both patient groups. During a mean follow-up period of 821 ± 218 days, 16 (54%) of the HD patients remained free from AF recurrence without any antiarrhythmic agents versus 47 (78%) of the control patients with an initial ablation (P = 0.013). A second ablation procedure was performed in 12 patients with an AF recurrence, and consequently 20 (67%) of the HD patients were in sinus rhythm compared to 53 (88%) of the controls during a follow-up duration of 747 ± 221 after the last ablation (P = 0.012). Bleeding from the venipuncture site requiring a prolonged hospital stay was identified in 2 HD patients and 1 control subject, while no life-threatening complications were observed in either patient group. CONCLUSION: Although the success rate of the PV isolation in HD patients was far from satisfactory, it may be considered as one of the therapeutic options for them.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Sistema de Conducción Cardíaco/cirugía , Fallo Renal Crónico/rehabilitación , Venas Pulmonares/cirugía , Diálisis Renal , Anciano , Fibrilación Atrial/complicaciones , Femenino , Humanos , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/cirugía , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...