Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
World Neurosurg X ; 23: 100381, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38706708

RESUMEN

Objective: To investigate on three-dimensional (3D) fusion images the apposition of low-profile visualized intraluminal support (LVIS) stents in intracranial aneurysms after treatment and assess inter-rater reliability. Materials and methods: Records of all patients with unruptured intracranial aneurysms who were treated with the LVIS stent were retrospectively accessed and included in this study. Two neurosurgeons evaluated the presence of malapposition between the vessel walls and the stent trunk (crescent sign) and the vessel wall and the stent edges (edge malappostion) on 3D fusion images. These images were high-resolution cone-beam computed tomography images of the LVIS stent fused with 3D-digital subtraction angiography images of the vessels. Associations between malapposition and aneurysm location were assessed by Fisher's exact test, and inter-rater agreement was estimated using Cohen's kappa statistic. Results: Forty consecutive patients were included. In all patients, 3D fusion imaging successfully visualized the tantalum helical strands and the closed-cell structure of the nitinol material of the low-profile visualized intraluminal support. A crescent sign was observed in 27.5 % and edge malapposition in 47.5 % of the patients. Malapposition was not significantly associated with location (p = 0.23 crescent sign, p = 0.07 edge malapposition). Almost perfect (κ = 0.88) and substantial (κ = 0.76) agreements between the two raters were found for the detection of crescent signs and edge appositions, respectively. Conclusions: 3D fusion imaging provided clear visualization of the LVIS stent and parent arteries, and could detect malapposition with excellent inter-rater reliability. This technique may provide valuable guidance for surgeons in determining postoperative management.

2.
No Shinkei Geka ; 52(2): 263-269, 2024 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-38514115

RESUMEN

With the advent of high-resolution imaging and advancements in computational fluid dynamics(CFD)and computational structural mechanics(CSM)analyses, clinical simulation of endovascular intervention has gradually become feasible. Virtual stents have become indispensable for coil embolization. For braided stents, such as those with low-profile visualized intraluminal support and flow diverters, predicting postplacement elongation and contraction is challenging; however, software development has enabled more precise treatment planning. Additionally, simulations utilizing three-dimensional(3D)printer models can enable realistic simulations of procedures such as intracranial stents and Woven EndoBridge placement. This approach is beneficial for shunt disorders such as arteriovenous malformations and dural arteriovenous fistulas, offering 3D visualization of shunt access routes and intuitive treatment strategy planning, even for beginners. Furthermore, it can be applied to procedures such as open surgical clipping and nidus resection, aiding in the selection of suitable clips and considerations for ideal resection based on nidus curvature. Simulations using CFD, CSM, and 3D printers are crucial for training surgeons and handling new devices. Harnessing medicine-engineering synergy is essential, and regulatory approval(insurance coverage)and appropriate commercialization of simulations are paramount for the future.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/cirugía , Prótesis Vascular , Stents , Programas Informáticos , Embolización Terapéutica/métodos , Resultado del Tratamiento
3.
Front Neurol ; 15: 1343137, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38299017

RESUMEN

Introduction: Intraprocedural rupture (IPR) is a serious complication of endovascular coil embolization of unruptured intracranial aneurysms (UIAs). Although outcomes after IPR are poor, methods to prevent subsequent neurological deterioration have not yet been investigated. We evaluated the risk factors and management strategies for IPR, particularly the role of balloon guiding catheters (BGCs) in rapid hemostasis. Methods: We retrospectively reviewed all UIA cases treated with coil embolization at three institutions between 2003 and 2021, focusing on preoperative radiological data, operative details, and outcomes. Results: In total, 2,172 aneurysms were treated in 2026 patients. Of these, 19 aneurysms in 19 patients (0.8%) ruptured during the procedure. Multivariate analysis revealed that aneurysms with a bleb (OR: 3.03, 95% CI: 1.21 to 7.57, p = 0.017), small neck size (OR: 0.56, 95% CI: 0.37 to 0.85, p = 0.007), and aneurysms in the posterior communicating artery (PcomA) (OR: 4.92, 95% CI: 1.19 to 20.18, p = 0.027) and anterior communicating artery (AcomA) (OR: 12.08, 95% CI: 2.99 to 48.79, p < 0.001) compared with the internal carotid artery without PcomA were significantly associated with IPR. The incidence of IPR was similar between the non-BGC and BGC groups (0.9% vs. 0.8%, p = 0.822); however, leveraging BGC was significantly associated with lower morbidity and mortality rates after IPR (0% vs. 44%, p = 0.033). Discussion: The incidence of IPR was relatively low. A bleb, small aneurysm neck, and location on PcomA and AcomA are independent risk factors for IPR. The use of BGC may prevent fatal clinical deterioration and achieve better clinical outcomes in patients with IPR.

4.
J Neurointerv Surg ; 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38262727

RESUMEN

BACKGROUND: An intermediate catheter (IMC) can improve the maneuverability and stability of the microcatheter. OBJECTIVE: To investigate the efficacy and safety of using an IMC in triaxial systems for coil embolization of unruptured cerebral aneurysms (UCAs). METHODS: A total of 2430 consecutive saccular UCAs (2259 patients) that underwent initial coil embolization at three institutions between November 2003 and May 2023 were retrospectively reviewed. Patients were classified into two groups: with IMC (IMC(+)) and without IMC (IMC(-)). To investigate whether IMC use increased the rate of complete occlusion and the packing density, a propensity score-matched analysis was used to control for clinical, anatomical, and procedural features. RESULTS: Ultimately, 595 (24.5%) coil embolization used an IMC. Propensity score matching was successful for 424 paired IMC(+) and IMC(-) aneurysms. Compared with the IMC(-) group, the IMC(+) group had significantly higher rate of Raymond-Roy Occlusion Classification class 1 immediately after treatment (30.0% vs 20.8%, P=0.003) and at 6 months (28.8% vs 20.0%, P=0.004) and a higher volume embolization ratio (27.2% (SD 6.5%) vs 25.9% (SD 6.2%), P=0.003). Re-treatment rates were not significantly different between the two groups (0.7% vs 0.2%, P=0.624). No significant differences in the incidences of ischemic and hemorrhagic complications and IMC-related parent artery dissection were found between the two groups. CONCLUSION: Use of IMCs in triaxial systems can provide effective and safe support in coil embolization of UCAs because complete occlusion and dense coil packing can be achieved without increased complications.

5.
Oper Neurosurg (Hagerstown) ; 26(2): 180-187, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37819087

RESUMEN

BACKGROUND AND OBJECTIVES: Planning/guidance software became important tools for physicians' presurgical optimal decision-making. However, there are no intracranial stent products with specifically associated simulation software. We report the "premarket" clinical trial of a new braided stent with a customized simulation software. METHODS: A stent system with 3 mesh density types (16, 24, and 32 wire mesh) was designed based on computational flow dynamics technology, and a simulation software (virtual stent planner [VSP]) was developed for the optimal stent deployment planning. Stents were selected after simulation on preoperative 3D-processed angioimages, and accuracy of the VSP was evaluated. RESULTS: Thirty-three unruptured intracranial aneurysms were successfully treated with VSP guidance. Twenty aneurysms (61%) were anterior circulation aneurysms, and 13 (39%) were posterior circulation aneurysms. The average aneurysm size was 7.1 mm, and the mean follow-up period was 19.2 months (11-39.0). There was no major recurrence or retreatment during follow-up, 2 morbidity cases, and no mortality. VSP planning presented slightly smaller stent dimensions compared with postdeployment: 24.2 vs 25.5 mm average, error -1.3 mm, and difference rate-5.46%. CONCLUSION: Based on this result, the new stents and software guidance system were approved by the Ministry of Health and Welfare as a combined medical device. VSP provided precise deployment with minimal error compared with actual stent and can contribute to better stent deployment even for less experienced physicians.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Humanos , Embolización Terapéutica/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Estudios Prospectivos , Programas Informáticos , Stents
6.
Surg Neurol Int ; 14: 349, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37810302

RESUMEN

Background: During coil embolization of intracranial aneurysms, the aneurysmal neck needs to be evaluated because coil protrusion into the parent artery may lead to ischemic complications. However, the neck cannot always be clearly visualized due to the limitation of the angiography system and due to the structure of the aneurysm. As a visual aid, we propose a color-coded fusion imaging method that generates "virtual coil" images using preoperative three-dimensional digital subtraction angiography (3D-DSA) images. Case Description: Coil embolization for intracranial aneurysms was performed using the working angles determined from the preoperative 3D-DSA. The aneurysms were located at the middle cerebral artery, anterior communicating artery (A-com), and posterior communicating artery (P-com). The A-com and P-com aneurysms were recurrent. During the later phase of the procedure, physicians could not judge whether coils protruded into the parent artery on two-dimensional digital subtraction angiography (2D-DSA) images because an optimal working angle could not be realized. Virtual coil images were displayed on the angiography system's monitor to show the expected completed embolization, which could be compared to the current 2D-DSA images as a visual aid. Conclusion: Virtual coil images can provide visual aid to the treating physician during aneurysm coil embolization, which is useful when an accurate working angle cannot be reached.

7.
World Neurosurg ; 178: e339-e344, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37480988

RESUMEN

OBJECTIVE: Juvenile nasopharyngeal angiofibroma (JNA) is a very rare hemorrhagic vascular tumor that predominantly affects adolescent boys. The tumor is relatively large when detected, and the risk of intraoperative bleeding is high. We aimed to examine factors associated with intraoperative blood loss in JNA surgery. METHODS: Thirteen patients with JNA who underwent surgery at the Jikei University Hospital between 2009 and 2020 were retrospectively reviewed, and factors associated with blood loss were examined by single regression analysis. RESULTS: The mean age was 20.8 ± 7.7 years. Preoperative angiographic images were evaluated in 9 of the 13 cases. The 6 patients with the largest bleeding volumes, all had residual nutrient vessels from the internal carotid artery (ICA), with an average number of 2.5 vessels. The mean blood loss of patients with residual nutrient vessels from the ICA was 3037 ± 2568 mL. Single regression analysis of bleeding volume against the number of remaining nutrient vessels from the ICA and the total peak contrast density of nutrient vessels (Cmax) standardized by region of interest showed that the coefficient was positive (P < 0.05 for both), confirming a significant correlation between the 2, respectively. CONCLUSIONS: The amount of bleeding significantly correlated with the number of remaining nutrient vessels from the ICA after preoperative embolization and with the total Cmax/region of interest. The ability to predict the amount of preoperative blood loss using this study will facilitate proposals for external incisions in patients with JNA.

8.
J Stroke Cerebrovasc Dis ; 31(11): 106790, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36156445

RESUMEN

OBJECTIVES: Early detection of hemorrhagic transformation (HT) in patients with large vessel occlusion (LVO) after endovascular treatment is important for postoperative patient management. We investigated the diagnostic performance of intraoperative cone beam computed tomography (CBCT) with reference standard magnetic resonance imaging (MRI) for detecting HT. MATERIALS AND METHODS: Consecutive patients with LVO treated by endovascular treatment who underwent intraoperative CBCT and postoperative MRI were included. Two observers evaluated all images for the presence of HT. Sensitivity and specificity for detecting HT were calculated with MRI as reference standard. The observers classified HT according to the European Cooperative Acute Stroke Study (ECASS). Inter-method and inter-rater agreement for the detection of HT and for the ECASS classification were assessed using kappa or weighted Brennan-Prediger (wBP) statistics. RESULTS: Images of 106 procedures (94 for anterior circulation) were analyzed. The sensitivity and specificity for detecting HT on CBCT were 0.77 and 0.83, respectively, for all procedures and 0.83 and 0.8, respectively, for anterior circulation. The inter-method agreement for HT detection (κ = 0.63 overall, κ = 0.69 anterior circulation) and ECASS classification (wBP = 0.67 overall, wBP = 0.77 anterior circulation) were substantial. The inter-rater agreement for HT detection (κ = 0.87 overall, κ = 0.85 anterior circulation) and for ECASS classification (wBP = 0.95 overall, wBP = 0.92 anterior circulation) were almost perfect. CONCLUSIONS: The diagnostic performance of CBCT for the detection of HT in stroke patients treated for LVO was acceptable with excellent inter-rater agreement. Intraoperative CBCT may be useful to trigger early interventions if HT is detected, although detailed classifications of HT may be difficult.


Asunto(s)
Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Tomografía Computarizada de Haz Cónico/métodos , Imagen por Resonancia Magnética , Sensibilidad y Especificidad , Estudios Retrospectivos
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4184-4187, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892146

RESUMEN

A virtual stent deployment application was developed to estimate the appropriate and patient-specific size of a braided stent for patients who undergo endovascular treatment for intracranial aneurysms. Comparing between the simulated deployed and the actual stents, we evaluated the accuracy of the simulation results. Our results indicated that lengths of the virtual and actual stents matched well despite the actual stent being affected by a geometrical change of the parent artery.Clinical Relevance-Surgeons need to be well-experienced to select an appropriate braided stent size for endovascular treatment of intracranial aneurysms, because the actual length of the deployed stent changes. This simulation will be helpful to make tailor-made surgical planning regardless of the surgeons' individual skill level.


Asunto(s)
Aneurisma Intracraneal , Stents , Simulación por Computador , Humanos , Aneurisma Intracraneal/cirugía
10.
Surg Neurol Int ; 12: 439, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34513202

RESUMEN

BACKGROUND: We reviewed the clinical outcomes of a procedure that combines endovascular embolization and a direct surgical approach in a hybrid operating room (OR) for the treatment of refractory dural arteriovenous fistulas (dAVFs). METHODS: All patients with intracranial dAVFs who underwent a procedure combining endovascular embolization and direct surgical approach with biplane angiography or a robotic C-arm system in a hybrid OR between February 2004 and June 2020 were considered. Borden grading, occlusion rate, pre-and post-operative modified Rankin Scale (mRS) scores, and complications were retrospectively investigated. The pre-and postoperative mRS scores were compared using the Wilcoxon signed-ranks test. RESULTS: We evaluated 14 arteriovenous fistulas (AVFs) in consecutive 13 patients. Of these, ten AVFs were previously treated with endovascular embolization, ten were located in the transverse-sigmoid sinus, and four in the cortical vein. The Borden grade was II in two AVFs and III in 12 AVFs. Immediate occlusion of the AVF was achieved in 13 AVFs, and gradual occlusion was observed in one case. The median preoperative mRS was 1 (0-3), whereas the median postoperative mRS was 0 (0-1) which indicated marked improvement (P = 0.006). Complications including postoperative transient visual disturbance and intraprocedural extravasation were observed in only two cases. CONCLUSION: The combination of endovascular embolization and direct surgical approach in a hybrid OR could achieve sufficient occlusion of refractory AVFs with acceptable complication rates and improved symptoms.

11.
Surg Neurol Int ; 12: 85, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33767889

RESUMEN

BACKGROUND: Intraosseous arteriovenous fistula (AVF) is a rare clinical entity that typically presents with symptoms from their effect on surrounding structures. Here, we report a case of intraosseous AVF in the sphenoid bone that presented with bilateral abducens palsy. CASE DESCRIPTION: A previously healthy man presented with tinnitus for 1 month, and initial imaging suspected dural AVF of the cavernous sinus. Four-dimensional digital subtraction angiography (4D-DSA) imaging and a three-dimensional (3D) fused image from the bilateral external carotid arteries revealed that the shunt was in a large venous pouch within the sphenoid bone that was treated through transvenous coil embolization. His symptoms improved the day after surgery. CONCLUSION: This is a case presentation of intraosseous AVF in the sphenoid bone and highlights the importance of 4D-DSA and 3D fused images for planning the treatment strategy.

12.
Interv Neuroradiol ; 27(5): 622-630, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33615875

RESUMEN

BACKGROUND: Coil embolization of aneurysms of the ophthalmic segment of the internal carotid artery (ICA-OphA ANs) has potential risks of visual complications. We analyzed this risk and focused on the relationship of the ophthalmic artery (OphA) origin with the aneurysm neck. METHODS: From January 2003 to April 2018, 179 unruptured ICA-OphA ANs were treated with endovascular surgery in our institution. Two ruptured and four aneurysms with missing data were excluded. Finally, 173 unruptured aneurysms were included in this study. The aneurysms were classified into three groups according to the location of the OphA origin: Separate, Shared, and Dome type. We retrospectively assessed visual complications based on the relationship between types of aneurysm and postoperative angiographic findings for the OphA. RESULTS: Visual deficits remained permanent in eleven cases (6.4%). In the Dome type, visual complications were significantly more frequent compared to the Separate type. Change in the OphA flow was significantly associated with a higher complication rate of 2.9%, but patients with changed OphA flow had a significant rate of 7.5% (p = 0.020). We found no significant difference in the incidence of visual complications concerning the use of perioperative antithrombotic therapy. CONCLUSIONS: The location of OphA origin regarding the aneurysmal neck and postoperative OphA flow were significantly correlated with the visual outcome after coil embolization for ICA-OphA ANs. Post-procedural flow in the OphA was an important factor affecting the rate of ischemic retinal complications. Retinal embolic events occurred with preserved flow in the OphA, albeit at a lower rate.


Asunto(s)
Aneurisma , Enfermedades de las Arterias Carótidas , Embolización Terapéutica , Aneurisma Intracraneal , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/terapia , Arteria Carótida Interna/diagnóstico por imagen , Embolización Terapéutica/efectos adversos , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Arteria Oftálmica/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento
13.
Interv Neuroradiol ; 27(4): 503-510, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33412966

RESUMEN

BACKGROUND AND PURPOSE: The direct carotid exposure approach (DCEA) is a technical option for elderly patients with severe vessel tortuosity due to arteriosclerosis. We evaluated complications related to antiplatelet/anticoagulant management and compared the DCEA to standard transfemoral/transbrachial approaches (TFBA) in the treatment of unruptured intracranial aneurysms for elderly patients. METHODS: From August 2017 to August 2020, 52 patients (53 procedures) aged over 75 years with unruptured aneurysms in the anterior circulation were treated at our institution. All patients received dual antiplatelet drugs before the procedure. Eleven patients (21.2%) (12 procedures) were treated with the DCEA. The rest were treated with TFBA. The main indication of the DCEA was an unfavorable aortic arch or vessel tortuosity. Complications and the duration of the procedure were compared between the two groups. RESULTS: There were no significant differences between the two groups in age, aneurysm location, preoperative antiplatelet use, heparin use, or maximum activated clotting time (ACT) values. All endovascular treatments were successfully performed by DCEA. Among all parameters, the DCEA group had only bigger average aneurysm diameter (14 mm) and higher number of pipeline embolic device (PED) placement (58%). Time to the guiding-catheter placement was not significantly different between the groups (DCEA vs TFBA = 31.0 min vs 24.7 min, p = 0.178). No significant complications of DCEA, such as subcutaneous hematomas, were observed. . CONCLUSION: Even with the use of antiplatelet and anticoagulation therapy, the DCEA can be performed safely for unruptured aneurysms in elderly patients.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Anciano , Anticoagulantes/uso terapéutico , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
14.
J Neurosurg Case Lessons ; 1(4)2021 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-36131586

RESUMEN

BACKGROUND: The authors describe a noninvasive intraoperative imaging strategy of three-dimensional (3D) digital subtraction angiography (DSA) with intravenous (IV) contrast injection, using indocyanine green (ICG) as a test bolus, during extracranial-intracranial (EC-IC) bypass surgery for moyamoya disease. OBSERVATIONS: Four patients underwent EC-IC bypass surgery in a hybrid operating room. During the surgery, bypass patency was verified using ICG videoangiography and Doppler ultrasonography. After skin closure, the patients under anesthesia underwent IV 3D-DSA with a robotic C-arm in which the scan delay time for the 3D-DSA scan was estimated from the arrival time of ICG during the ICG videoangiography. One day after the surgery, the patients underwent magnetic resonance angiography (MRA). The IV 3D-DSA images were retrospectively compared with those obtained with other modalities. Good bypass patency was confirmed on IV 3D-DSA, ICG videoangiography, Doppler ultrasonography, and postoperative MRA in all cases. The delay time determined using ICG videoangiography as a test bolus resulted in IV 3D-DSA with adequate image quality, allowing assessment of the spatial relationships between the vessels and anastomoses from all directions. LESSONS: To evaluate bypass patency and anatomical relationships immediately after EC-IC bypass surgery, IV 3D-DSA may be a useful modality. ICG videoangiography can be used to determine the scan delay time.

15.
World Neurosurg ; 147: e388-e395, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33359518

RESUMEN

OBJECTIVE: To investigate flow diverter (FD) apposition on fused images acquired by high-resolution cone-beam computed tomography (CBCT) and 3-dimensional (3D) digital subtraction angiography. METHODS: Patients with large or giant internal carotid artery aneurysms treated with Pipeline FDs who underwent CBCT imaging at our institution between October 2016 and May 2019 were included. Two neurosurgeons measured the maximum malapposition between FDs and vessel walls on 3D fusion images of high-resolution CBCT images displaying the FD and 3D digital subtraction angiography images displaying the vessels. Associations between the relative malapposition, FD diameter, vessel diameter, proximal and distal vessel diameter discrepancy, and siphon angle were evaluated by linear regression analysis. Inter-rater and intermethod (3D and 2D image) agreements of the malapposition measurements were assessed by Bland-Altman analysis and by interclass correlation coefficients. RESULTS: Images of 2 patients were excluded because of image artifacts or fusion errors, and 3D fusion images were acquired in the remaining 26 patients. Our results did not suggest that relative malapposition was associated with vessel diameter (P = 0.12), vessel diameter discrepancy (P = 0.60), or syphon angle (P = 0.34), but relative malapposition increased by an estimated 13% (95% confidence interval: 4%-23%, P = 0.006) for each 1 mm increase in FD diameter. Inter-rater and intermethod agreements for apposition measurements were excellent and good, respectively. CONCLUSIONS: Three-dimensional fusion images provided clear visualization of structures of both the stent and parent artery with excellent diagnostic reliability. Careful deployment may be needed for FDs with larger diameters, as they tended to have larger relative malapposition.


Asunto(s)
Arteria Carótida Interna/cirugía , Tomografía Computarizada de Haz Cónico , Imagenología Tridimensional , Aneurisma Intracraneal/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital/métodos , Angiografía Cerebral/métodos , Tomografía Computarizada de Haz Cónico/métodos , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
16.
World Neurosurg ; 146: e701-e707, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33181375

RESUMEN

OBJECTIVE: We report the clinical outcomes of stent-assisted coiling for wide-necked intracranial aneurysms using 3 low-profile laser-cut stents and compare the results according to stent type. METHODS: All patients treated with stent-assisted coiling for their intracranial aneurysms at our hospital between July 2010 and September 2019 were reviewed. We selected patients with Enterprise, Neuroform EZ, or Neuroform Atlas stents who underwent imaging follow-up and investigated aneurysm and stent features, stent-related complications, recanalization, and retreatment rates. We compared the retreatment risk among the patients treated with the 3 stent types using Kaplan-Meier survival analysis and Cox regression analysis. RESULTS: We evaluated 364 consecutive cases (103 Enterprise, 105 Neuroform EZ, and 156 Neuroform Atlas stents). Neuroform Atlas was more frequently used in distal vessels: 8 (7.8%) Enterprise, 2 (1.9%) Neuroform EZ, and 41 (26.3%) Neuroform Atlas cases, respectively. The median follow-up durations were 6.49, 4.91, and 1.24 years for the Enterprise, Neuroform EZ, and Neuroform Atlas cases, respectively, and retreatment was performed in 11 (10.1%), 9 (8.6%), and 6 (3.8%) cases. In the first 2 years of follow-up, the estimated retreatment risk ratios for Neuroform EZ and Neuroform Atlas with Enterprise as reference were 0.63 (95% confidence interval, 0.24-1.65; P = 0.35) and 0.54 (95% confidence interval, 0.18-1.59; P = 0.26), respectively. CONCLUSIONS: Neuroform Atlas stents were more frequently deployed in small-caliber vessels compared with the other 2 types of stents. The complication rate and retreatment risk until at least 1 year after the aneurysm treatment appeared to be similar for the 3 stent types.


Asunto(s)
Aneurisma Roto/cirugía , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/cirugía , Stents , Anciano , Aneurisma Roto/diagnóstico por imagen , Arteria Cerebral Anterior/diagnóstico por imagen , Arteria Cerebral Anterior/cirugía , Arteria Basilar/diagnóstico por imagen , Arteria Basilar/cirugía , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/cirugía , Infarto Cerebral/epidemiología , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Hemorragias Intracraneales/epidemiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Arteria Cerebral Media/diagnóstico por imagen , Arteria Cerebral Media/cirugía , Arteria Cerebral Posterior/diagnóstico por imagen , Arteria Cerebral Posterior/cirugía , Complicaciones Posoperatorias/epidemiología , Hemorragia Posoperatoria/epidemiología , Modelos de Riesgos Proporcionales , Reoperación , Estudios Retrospectivos , Rotura Espontánea/cirugía , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/cirugía
17.
J Stroke Cerebrovasc Dis ; 29(12): 105327, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32992207

RESUMEN

PURPOSE: To assess the benefit and radiation dose of four-dimensional (4D) digital subtraction angiography (DSA) - a time resolved three-dimensional (3D) DSA application - to evaluate the flow and architecture of aneurysms and vascular malformations. METHODS: All patients with cerebrovascular disease were considered who underwent 4D-DSA at our institution between January 2015 and February 2016. For the aneurysm patients, we evaluated the image quality in terms of the visualization of contrast flow in the aneurysm on a 3-point scale (excellent, fair and poor). Interrater agreement between two raters was estimated using Cohen's Kappa statistics. For the shunt disease patients, the additional information obtained from the 4D-DSA was described for each disease. The median radiation dose and volume of contrast medium required for the acquisitions were estimated. RESULTS: A total of 173 patients underwent 4D-DSA; 126 intracranial aneurysms, 10 arteriovenous malformations (AVM), 15 dural arteriovenous fistula (dAVF) and 22 other diseases. For aneurysm patients, excellent and fair visualization of the intra-aneurysmal flow was observed in 27.7%, 72.3%, and excellent (κ = 0.9) agreement between the raters was found. For AVM and dAVF patients, 4D-DSA clarified the complex vasculature by viewing the discrete time phase of contrast filling. Median radiation dose for intracranial lesions was 79.6 mGy for 6s 4D-DSA, and 175 mGy for 12s 4D-DSA. The median amount of contrast medium used was 18.0 ml for 6s 4D-DSA and 21.0 ml for 12s 4D-DSA. CONCLUSIONS: 4D-DSA provided additional information regarding intra-aneurysmal flow and contributed to detect different component of nidus or shunt points.


Asunto(s)
Angiografía de Substracción Digital , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Angiografía Cerebral , Circulación Cerebrovascular , Aneurisma Intracraneal/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Malformaciones Vasculares del Sistema Nervioso Central/fisiopatología , Femenino , Humanos , Aneurisma Intracraneal/fisiopatología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
18.
World Neurosurg ; 144: 43-49, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32805464

RESUMEN

BACKGROUND: Foramen magnum dural arteriovenous fistula (DAVF) is a rare disease, with some reported cases of successful treatment. We achieved complete obliteration of the foramen magnum DAVF through microsurgery after complications of endovascular embolization. We reviewed the treatment modalities and outcomes, focusing on pathologic and anatomic features from the literature. CASE DESCRIPTION: A 65-year-old man was admitted to our hospital with sudden diplopia. Magnetic resonance imaging revealed a subarachnoid hemorrhage around the right side of the prepontine cistern, and a foramen magnum DAVF was diagnosed by angiography. Subsequent angiography revealed that the fistula was supplied by the right neuromeningeal trunk of the ascending pharyngeal artery and the right posterior meningeal artery of the vertebral artery (VA), and the veins of the pouch via the fistula were retrogradely draining into the intracranial veins. We aimed to treat complete occlusion endovascularly with balloon-augmented transarterial Onyx injection via the posterior meningeal artery, but Onyx was refluxed to the VA through the anastomosis between the VA and posterior meningeal artery. Onyx subsequently migrated to the top of the basilar artery, causing occlusion, so we urgently removed the Onyx with a stent retriever (Trevo). Several weeks later, we performed complete obliteration of the foramen magnum DAVF via a lateral suboccipital approach with a C1 laminectomy. CONCLUSIONS: Most foramen magnum DAVFs were obliterated completely with only endovascular treatment. Microsurgery is an effective and reliable treatment for incomplete occlusion and complications.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central/cirugía , Dimetilsulfóxido/efectos adversos , Foramen Magno/cirugía , Microcirugia/métodos , Polivinilos/efectos adversos , Insuficiencia del Tratamiento , Anciano , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Dimetilsulfóxido/administración & dosificación , Foramen Magno/diagnóstico por imagen , Humanos , Masculino , Polivinilos/administración & dosificación
19.
J Neurointerv Surg ; 12(2): 192-196, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31405991

RESUMEN

PURPOSE: We used an imaging technique based on 3-dimensional (3D) C-arm CT to assess the apposition of three types of stents after coiling of intracranial aneurysms. METHODS: All patients with intracranial aneurysms were considered who received stent-assisted coiling with Enterprise2, Neuroform EZ, or Neuroform Atlas stents confirmed by C-arm CT imaging at our institution between June 2015 and November 2017. A 3D digital subtraction angiography (DSA) scan for vessel imaging followed by a high-resolution cone beam CT (HR-CBCT) scan for coil and stent imaging was performed. The images were fused to obtain dual volume 3D fusion images. We investigated malapposition of the stent trunk (crescent sign) and of the stent edges (edge malapposition) and used the χ2 statistic to test for an association with stent types. Inter-rater agreement between two raters was estimated using Cohen's kappa statistics. RESULTS: We evaluated 75 consecutive cases. Enterprise2 stents were used in 22 cases, Neuroform EZ in 26, and Neuroform Atlas in 27 cases. By stent type, crescent sign was detected in 27% of Enterprise2, 8% of Neuroform EZ, and none of Neuroform Atlas stents (p=0.007), while edge malapposition was detected in 27% of Enterprise2, 58% of Neuroform EZ, and 30% of Neuroform Atlas stents (p=0.05). Excellent (κ=0.81) and good (κ=0.78) agreement between the raters was found for the detection of edge apposition and crescent sign, respectively. CONCLUSION: Stent malapposition was clearly visualized by dual volume 3D imaging. The Neuroform Atlas stents showed good apposition even in vessels with strong curvature.


Asunto(s)
Angiografía Cerebral/métodos , Tomografía Computarizada de Haz Cónico/métodos , Imagenología Tridimensional/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Stents Metálicos Autoexpandibles , Adulto , Anciano , Angiografía de Substracción Digital/métodos , Embolización Terapéutica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
20.
World Neurosurg ; 134: e731-e738, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31704360

RESUMEN

OBJECTIVE: Risk control of thromboembolic complications (TECs) during stent-assisted coil embolization (SACE) for unruptured intracranial aneurysms (UIAs) is crucial for satisfactory treatment outcomes. We retrospectively evaluated the data from our cohort of SACE for UIAs to analyze the role of anatomical, clinical, and stent type-related factors to determine the optimal preoperative values of light transmission aggregometry (LTA) for TEC prevention. METHODS: From July 2015 to May 2018, we retrospectively analyzed the data from 132 patients with SACE-treated UIAs at our hospital. Data regarding the aneurysm location, maximum diameter, stent type used, preoperative LTA value, and ischemic and hemorrhagic complications were collected. Aspirin 100 mg and clopidogrel 75 mg were started 7 days before surgery, with a "boost" dose (an additional 75 mg of clopidogrel for an LTA value >60%) added after August 2016 to address clopidogrel resistance. After multivariate analysis, we developed our original combined parameter termed the thromboembolic predictor (TEP). Receiver operating characteristic (ROC) analysis for TEP and each significant variable was performed. RESULTS: TECs were confirmed in 5 of the 132 patients (3.8%) and hemorrhagic complications in 9 of the 132 patients (6.8%). From the multivariate analysis results, the LTA value and maximum diameter were chosen as significant variables and included in the TEP. ROC analysis of the LTA value revealed a sensitivity and specificity of 0.866 and 0.600, respectively (area under the curve, 0.747), with a cutoff of 62%. TEP permitted the establishment of an optimal LTA value according to the aneurysm maximum diameter to predict for TECs. The complication rate for the Neuroform EZ, Enterprise, Neuroform Atlas, and LVIS stents was 2.9%, 10.5%, 1.4%, and 14.3%, respectively. CONCLUSIONS: The preoperative LTA value contributes to the prediction of TECs after SACE for UIAs. The TEP (relating the LTA cutoff to aneurysm size) allows for improved antiplatelet therapy adjustment before SACE to reduce TECs.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Agregación Plaquetaria , Stents , Tromboembolia/epidemiología , Aspirina/uso terapéutico , Clopidogrel/uso terapéutico , Procedimientos Endovasculares , Femenino , Hematoma/epidemiología , Hemorragia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Función Plaquetaria , Estudios Retrospectivos , Medición de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...