Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 32(12): 20421-20431, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38859424

RESUMEN

Conventional fiber-bundle-based endoscopes allow minimally invasive imaging through flexible multi-core fiber (MCF) bundles by placing a miniature lens at the distal tip and using each core as an imaging pixel. In recent years, lensless imaging through MCFs was made possible by correcting the core-to-core phase distortions pre-measured in a calibration procedure. However, temporally varying wavefront distortions, for instance, due to dynamic fiber bending, pose a challenge for such approaches. Here, we demonstrate a coherent lensless imaging technique based on intensity-only measurements insensitive to core-to-core phase distortions. We leverage a ptychographic reconstruction algorithm to retrieve the phase and amplitude profiles of reflective objects placed at a distance from the fiber tip, using as input a set of diffracted intensity patterns reflected from the object when the illumination is scanned over the MCF cores. Our approach thus utilizes an acquisition process equivalent to confocal microendoscopy, only replacing the single detector with a camera.

2.
Opt Express ; 31(7): 11705-11716, 2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37155799

RESUMEN

Coherent fiber bundles are widely used for endoscopy, but conventional approaches require distal optics to form an object image and acquire pixelated information owing to the geometry of the fiber cores. Recently, holographic recording of a reflection matrix enables a bare fiber bundle to perform pixelation-free microscopic imaging as well as allows a flexible mode operation, because the random core-to-core phase retardations due to any fiber bending and twisting could be removed in situ from the recorded matrix. Despite its flexibility, the method is not suitable for a moving object because the fiber probe should remain stationary during the matrix recording to avoid the alteration of the phase retardations. Here, we acquire a reflection matrix of a Fourier holographic endoscope equipped with a fiber bundle and explore the effect of fiber bending on the recorded matrix. By removing the motion effect, we develop a method that can resolve the perturbation of the reflection matrix caused by a continuously moving fiber bundle. Thus, we demonstrate high-resolution endoscopic imaging through a fiber bundle, even when the fiber probe changes its shape along with the moving objects. The proposed method can be used for minimally invasive monitoring of behaving animals.

3.
Nat Commun ; 13(1): 4469, 2022 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-35918348

RESUMEN

Ultrathin lensless fibre endoscopes offer minimally invasive investigation, but they mostly operate as a rigid type due to the need for prior calibration of a fibre probe. Furthermore, most implementations work in fluorescence mode rather than label-free imaging mode, making them unsuitable for general medical diagnosis. Herein, we report a fully flexible ultrathin fibre endoscope taking 3D holographic images of unstained tissues with 0.85-µm spatial resolution. Using a bare fibre bundle as thin as 200-µm diameter, we design a lensless Fourier holographic imaging configuration to selectively detect weak reflections from biological tissues, a critical step for label-free endoscopic reflectance imaging. A unique algorithm is developed for calibration-free holographic image reconstruction, allowing us to image through a narrow and curved passage regardless of fibre bending. We demonstrate endoscopic reflectance imaging of unstained rat intestine tissues that are completely invisible to conventional endoscopes. The proposed endoscope will expedite a more accurate and earlier diagnosis than before with minimal complications.


Asunto(s)
Endoscopios , Holografía , Animales , Endoscopía , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Ratas
4.
Opt Express ; 29(21): 34360-34369, 2021 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-34809228

RESUMEN

We present a low-coherence interferometric imaging system designed for 3-dimensional (3-D) imaging of a macroscopic object through a narrow passage. Our system is equipped with a probe-type port composed of a bundle fiber for imaging and a separate multimode optical fiber for illumination. To eliminate the need for mechanical depth scanning, we employ a spatial frequency multiplexing method by installing a 2-D diffraction grating and an echelon in the reference arm. This configuration generates multiple reference beams, all having different path lengths and propagation directions, which facilitates the encoding of different depth information in a single interferogram. We demonstrate the acquisition of 9 depth images at the interval of 250 µm for a custom-made cone and a plaster teeth model. The proposed system minimizes the need for mechanical scanning and achieves a wide range of depth coverage, significantly increasing the speed of 3-D imaging for macroscopic objects.

5.
Sci Rep ; 7(1): 6524, 2017 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-28747650

RESUMEN

Thin waveguides such as graded-index lenses and fiber bundles are often used as imaging probes for high-resolution endomicroscopes. However, strong back-reflection from the end surfaces of the probes makes it difficult for them to resolve weak contrast objects, especially in the reflectance-mode imaging. Here we propose a method to spatially isolate illumination pathways from detection channels, and demonstrate wide-field reflectance imaging free from back-reflection noise. In the image fiber bundle, we send illumination light through individual core fibers and detect signals from target objects through the other fibers. The transmission matrix of the fiber bundle is measured and used to reconstruct a pixelation-free image. We demonstrated that the proposed imaging method improved 3.2 times on the signal to noise ratio produced by the conventional illumination-detection scheme.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...