Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Sci Rep ; 13(1): 17478, 2023 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-37838804

RESUMEN

Omicron has become the dominant SARS-CoV-2 variant globally since December 2021, with distinct waves being associated with separate Omicron sublineages. Rapid detection of BA.1, BA.2, BA.4, and BA.5 was accomplished in the province of Alberta, Canada, through the design and implementation of real-time reverse transcriptase PCR assays targeting S:N501Y, S:ins214EPE, S:H69/V70, ORF7b:L11F, and M:D3N. Using the combination of results for each of these markers, samples could be designated as belonging to sublineages within BA.1, BA.2, BA.4, or BA.5. The analytical sensitivity of these markers ranged from 132 to 2229 copies/mL and in-laboratory accuracy was 98.9-100%. A 97.3% agreement using 12,592 specimens was demonstrated for the assays compared to genome sequencing. The use of these assays, combined with genome sequencing, facilitated the surveillance of SARS-CoV-2 lineages throughout a BA.5-dominated period.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , ADN Polimerasa Dirigida por ARN , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Alberta , Prueba de COVID-19
2.
CMAJ ; 195(31): E1030-E1037, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37580072

RESUMEN

BACKGROUND: During the first year of the COVID-19 pandemic, the proportion of reported cases of COVID-19 among Canadians was under 6%. Although high vaccine coverage was achieved in Canada by fall 2021, the Omicron variant caused unprecedented numbers of infections, overwhelming testing capacity and making it difficult to quantify the trajectory of population immunity. METHODS: Using a time-series approach and data from more than 900 000 samples collected by 7 research studies collaborating with the COVID-19 Immunity Task Force (CITF), we estimated trends in SARS-CoV-2 seroprevalence owing to infection and vaccination for the Canadian population over 3 intervals: prevaccination (March to November 2020), vaccine roll-out (December 2020 to November 2021), and the arrival of the Omicron variant (December 2021 to March 2023). We also estimated seroprevalence by geographical region and age. RESULTS: By November 2021, 9.0% (95% credible interval [CrI] 7.3%-11%) of people in Canada had humoral immunity to SARS-CoV-2 from an infection. Seroprevalence increased rapidly after the arrival of the Omicron variant - by Mar. 15, 2023, 76% (95% CrI 74%-79%) of the population had detectable antibodies from infections. The rapid rise in infection-induced antibodies occurred across Canada and was most pronounced in younger age groups and in the Western provinces: Manitoba, Saskatchewan, Alberta and British Columbia. INTERPRETATION: Data up to March 2023 indicate that most people in Canada had acquired antibodies against SARS-CoV-2 through natural infection and vaccination. However, given variations in population seropositivity by age and geography, the potential for waning antibody levels, and new variants that may escape immunity, public health policy and clinical decisions should be tailored to local patterns of population immunity.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/epidemiología , Pandemias , Estudios Seroepidemiológicos , Alberta , Anticuerpos Antivirales
3.
Am J Gastroenterol ; 118(9): 1693-1697, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37216598

RESUMEN

INTRODUCTION: We determined adverse events after 4 doses of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) vaccine in those with inflammatory bowel disease (IBD), associations between antibodies and injection site reactions (ISR), and risk of IBD flare. METHODS: Individuals with IBD were interviewed for adverse events to SARS-CoV-2 vaccine. Multivariable linear regression assessed the association between antibody titers and ISR. RESULTS: Severe adverse events occurred in 0.03%. ISR were significantly associated with antibody levels after the fourth dose (geometric mean ratio = 2.56; 95% confidence interval 1.18-5.57). No cases of IBD flare occurred. DISCUSSION: SARS-CoV-2 vaccines are safe for those with IBD. ISR after the fourth dose may indicate increased antibodies.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Enfermedades Inflamatorias del Intestino , Humanos , Anticuerpos Antivirales , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Reacción en el Punto de Inyección , SARS-CoV-2 , Vacunación
4.
Artículo en Inglés | MEDLINE | ID: mdl-37008576

RESUMEN

Background: A multi-country outbreak of monkeypox virus (MPXV) infections was identified by the World Health Organization in May 2022. The western Canadian province of Alberta identified its first case of MPXV in a returning traveller on June 2, 2022. We undertook a retrospective testing exercise to evaluate whether MPXV may have been circulating in the province earlier. Methods: Skin (genital and non-genital) and mucosal lesion swabs submitted for herpes simplex virus (HSV)/varicella zoster virus (VZV)/syphilis testing from male patients attending sexually-transmitted infection clinics across the province of Alberta from January 28 to May 30, 2022 were retrieved from storage. The population tested was selected based on the epidemiology of the current 2022 multi-country MPXV outbreak. Samples underwent viral nucleic acid extraction and testing for the presence of Orthopoxvirus DNA using a commercial real-time polymerase chain reaction (PCR) kit. Results: A total of 392 samples (representing 341 unique individuals of median age 31 years) were retrieved. Of them, 349 (89.0%) samples were submitted for HSV/VZV/syphilis testing, 13 (3.3%) for HSV/VZV only, and 30 (7.7%) for syphilis PCR only. None of the 392 samples tested were found to be positive for Orthopoxvirus DNA. Conclusions: The results of this study indicate that circulation of MPXV in a higher-risk population in Alberta, prior to the first case, was less likely. We recommend that other provinces/territories review their local epidemiology, context and resources prior to conducting similar studies.


Historique: En mai 2022, l'Organisation mondiale de la Santé a déclaré une flambée multinationale d'infection par le virus de la variole simienne (MPXV). Le 2 juin 2022, la province de l'Alberta, dans l'Ouest canadien, a recensé son premier cas de MPXV chez un voyageur de retour de l'étranger. Les chercheurs ont entrepris un exercice de dépistage rétrospectif pour évaluer la possibilité que le MPXV ait circulé auparavant dans la province. Méthodologie: Les chercheurs ont extrait de l'entreposage les écouvillons des lésions cutanées (génitales et non génitales) et muqueuses soumis en vue de dépister le virus herpès simplex (VHS), le virus varicelle-zona (VZV) et le virus de la syphilis des patients de sexe masculin qui avaient fréquenté les cliniques d'infections transmises sexuellement de la province de l'Alberta entre le 28 janvier et le 30 mai 2022. Ils ont sélectionné la population soumise au dépistage en fonction de l'épidémiologie de la flambée multinationale de MPXV en 2022. Les écouvillons ont été soumis à l'extraction et au test des acides nucléiques viraux pour dépister la présence d'ADN de l'Orthopoxvirus au moyen d'un test commercial d'amplification en chaîne par polymérase (PCR). RÉsultats: Les chercheurs ont extrait un total de 392 échantillons (représentant 341 personnes uniques d'un âge médian de 31 ans). De ce nombre, 349 (89,0 %) avaient été soumis au test PCR du VHS, du VZV et de la syphilis, 13 (3,3 %), du VHS et du VZV seulement et 30 (7,7 %), de la syphilis seulement. Aucun des 392 échantillons n'a donné de résultat positif à l'ADN de l'Orthopoxvirus. Conclusions: D'après les résultats de la présente étude, il est peu probable que le MPXV ait circulé dans la population plus vulnérable de l'Alberta avant la détection du premier cas. Les chercheurs recommandent que les autres provinces et territoires examinent leur épidémiologie locale, le contexte et les ressources avant de procéder à des études de ce type.

5.
PLoS One ; 18(4): e0284046, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37023007

RESUMEN

BACKGROUND: Measurement of SARS-CoV-2 antibody seropositivity is important to accurately understand exposure to infection and/or vaccination in specific populations. This study aimed to estimate the serologic response to SARS-CoV-2 virus infection and vaccination in children in Calgary, Alberta over a two-year period. METHODS: Children with or without prior SARS-CoV-2 infections, were enrolled in Calgary, Canada in 2020. Venous blood was sampled 4 times from July 2020 to April 2022 for SARS-CoV-2 nucleocapsid and spike antibodies. Demographic and clinical information was obtained including SARS-CoV-2 testing results and vaccination records. RESULTS: 1035 children were enrolled and 88.9% completed all 4 visits; median age 9 years (IQR: 5,13); 519 (50.1%) female; and 815 (78.7%) Caucasian. Before enrolment, 118 (11.4%) had confirmed or probable SARS-CoV-2. By April 2022, 39.5% of previously uninfected participants had a SARS-CoV-2 infection. Nucleocapsid antibody seropositivity declined to 16.4% of all infected children after more than 200 days post diagnosis. Spike antibodies remained elevated in 93.6% of unvaccinated infected children after more than 200 days post diagnosis. By April 2022, 408 (95.6%) children 12 years and older had received 2 or more vaccine doses, and 241 (61.6%) 5 to 11 year-old children had received 2 vaccine doses. At that time, all 685 vaccinated children had spike antibodies, compared with 94/176 (53.4%) of unvaccinated children. CONCLUSIONS: In our population, after the first peak of Omicron variant infections and introduction of COVID-19 vaccines for children, all vaccinated children, but just over one-half of unvaccinated children, had SARS-CoV-2 spike antibodies indicating infection and/or vaccination, highlighting the benefit of vaccination. It is not yet known whether a high proportion of seropositivity at the present time predicts sustained population-level protection against future SARS-CoV-2 transmission, infection or severe COVID-19 outcomes in children.


Asunto(s)
COVID-19 , SARS-CoV-2 , Niño , Femenino , Humanos , Preescolar , Masculino , Alberta/epidemiología , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19 , Formación de Anticuerpos , Prueba de COVID-19 , Estudios Seroepidemiológicos , Vacunación , Anticuerpos Antivirales
6.
Vaccine ; 41(17): 2734-2738, 2023 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-36948982

RESUMEN

OBJECTIVES: To assess the guideline concordance of medical school requirements for students' proof-of-immunity in the United States (US) and Canada. METHODS: National guidelines for healthcare worker proof-of-immunity to measles, mumps, rubella, and varicella were compared to admission requirements for 62 US and 17 Canadian medical schools. RESULTS: All surveyed schools accepted at least one recommended form of proof-of-immunity, however, contrary to national guidelines, 16% of surveyed US schools asked for a serologic titer, and only 73-79% US schools accepted vaccination as the sole proof-of-immunity. CONCLUSIONS: The requirement of numerical, non-standardized serologic testing highlights an oversight in medical school admissions documentation. The requirement for quantitative values to demonstrate immunity is not practical from a laboratory standpoint, and is not needed to show individual immunity to these vaccine-preventable diseases. Until a more standardized process is adopted, laboratories will need to provide clear documentation and direction for quantitative titer requests.


Asunto(s)
Varicela , Sarampión , Paperas , Rubéola (Sarampión Alemán) , Estudiantes de Medicina , Humanos , Estados Unidos , Canadá , Sarampión/prevención & control , Rubéola (Sarampión Alemán)/prevención & control , Varicela/prevención & control , Vacuna contra la Varicela , Vacunación , Vacuna contra el Sarampión-Parotiditis-Rubéola , Facultades de Medicina , Anticuerpos Antivirales
7.
Microsyst Nanoeng ; 9: 3, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36597510

RESUMEN

The COVID-19 pandemic has posed enormous challenges for existing diagnostic tools to detect and monitor pathogens. Therefore, there is a need to develop point-of-care (POC) devices to perform fast, accurate, and accessible diagnostic methods to detect infections and monitor immune responses. Devices most amenable to miniaturization and suitable for POC applications are biosensors based on electrochemical detection. We have developed an impedimetric immunosensor based on an interdigitated microelectrode array (IMA) to detect and monitor SARS-CoV-2 antibodies in human serum. Conjugation chemistry was applied to functionalize and covalently immobilize the spike protein (S-protein) of SARS-CoV-2 on the surface of the IMA to serve as the recognition layer and specifically bind anti-spike antibodies. Antibodies bound to the S-proteins in the recognition layer result in an increase in capacitance and a consequent change in the impedance of the system. The impedimetric immunosensor is label-free and uses non-Faradaic impedance with low nonperturbing AC voltage for detection. The sensitivity of a capacitive immunosensor can be enhanced by simply tuning the ionic strength of the sample solution. The device exhibits an LOD of 0.4 BAU/ml, as determined from the standard curve using WHO IS for anti-SARS-CoV-2 immunoglobulins; this LOD is similar to the corresponding LODs reported for all validated and established commercial assays, which range from 0.41 to 4.81 BAU/ml. The proof-of-concept biosensor has been demonstrated to detect anti-spike antibodies in sera from patients infected with COVID-19 within 1 h. Photolithographically microfabricated interdigitated microelectrode array sensor chips & label-free impedimetric detection of COVID-19 antibody.

8.
J Med Virol ; 95(2): e28442, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36579780

RESUMEN

Wastewater-based SARS-CoV-2 surveillance enables unbiased and comprehensive monitoring of defined sewersheds. We performed real-time monitoring of hospital wastewater that differentiated Delta and Omicron variants within total SARS-CoV-2-RNA, enabling correlation to COVID-19 cases from three tertiary-care facilities with >2100 inpatient beds in Calgary, Canada. RNA was extracted from hospital wastewater between August/2021 and January/2022, and SARS-CoV-2 quantified using RT-qPCR. Assays targeting R203M and R203K/G204R established the proportional abundance of Delta and Omicron, respectively. Total and variant-specific SARS-CoV-2 in wastewater was compared to data for variant specific COVID-19 hospitalizations, hospital-acquired infections, and outbreaks. Ninety-six percent (188/196) of wastewater samples were SARS-CoV-2 positive. Total SARS-CoV-2 RNA levels in wastewater increased in tandem with total prevalent cases (Delta plus Omicron). Variant-specific assessments showed this increase to be mainly driven by Omicron. Hospital-acquired cases of COVID-19 were associated with large spikes in wastewater SARS-CoV-2 and levels were significantly increased during outbreaks relative to nonoutbreak periods for total SARS-CoV2, Delta and Omicron. SARS-CoV-2 in hospital wastewater was significantly higher during the Omicron-wave irrespective of outbreaks. Wastewater-based monitoring of SARS-CoV-2 and its variants represents a novel tool for passive COVID-19 infection surveillance, case identification, containment, and potentially to mitigate viral spread in hospitals.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , ARN Viral , Aguas Residuales , Centros de Atención Terciaria , Brotes de Enfermedades
9.
Infect Control Hosp Epidemiol ; 44(5): 805-808, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-34866560

RESUMEN

To assess the burden of respiratory virus coinfections with severe acute respiratory coronavirus virus 2 (SARS-CoV-2), this study reviewed 4,818 specimens positive for SARS-CoV-2 and tested using respiratory virus multiplex testing. Coinfections with SARS-CoV-2 were uncommon (2.8%), with enterovirus or rhinovirus as the most prevalent target (88.1%). Respiratory virus coinfection with SARS-CoV-2 remains low 1 year into the coronavirus disease 2019 (COVID-19) pandemic.


Asunto(s)
COVID-19 , Coinfección , Infecciones por Enterovirus , Humanos , SARS-CoV-2 , Coinfección/epidemiología , Alberta , Pandemias
11.
Biosensors (Basel) ; 14(1)2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38248383

RESUMEN

Label-free electrochemical biosensors have many desirable characteristics in terms of miniaturization, scalability, digitization, and other attributes associated with point-of-care (POC) applications. In the era of COVID-19 and pandemic preparedness, further development of such biosensors will be immensely beneficial for rapid testing and disease management. Label-free electrochemical biosensors often employ [Fe(CN)6]-3/4 redox probes to detect low-concentration target analytes as they dramatically enhance sensitivity. However, such Faradaic-based sensors are reported to experience baseline signal drift, which compromises the performance of these devices. Here, we describe the use of a mecaptohexanoic (MHA) self-assembled monolayer (SAM) modified Au-interdigitated electrode arrays (IDA) to investigate the origin of the baseline signal drift, developed a protocol to resolve the issue, and presented insights into the underlying mechanism on the working of label-free electrochemical biosensors. Using this protocol, we demonstrate the application of MHA SAM-modified Au-IDA for POC analysis of human serum samples. We describe the use of a label-free electrochemical biosensor based on covalently conjugated SARS-CoV-2 spike protein for POC detection of COVID-19 antibodies. The test requires a short incubation time (10 min), and has a sensitivity of 35.4/decade (35.4%/10 ng mL-1) and LOD of 21 ng/mL. Negligible cross reactivity to seasonal human coronavirus or other endogenous antibodies was observed. Our studies also show that Faradaic biosensors are ~17 times more sensitive than non-Faradaic biosensors. We believe the work presented here contributes to the fundamental understanding of the underlying mechanisms of baseline signal drift and will be applicable to future development of electrochemical biosensors for POC applications.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Glicoproteína de la Espiga del Coronavirus , Humanos , COVID-19/diagnóstico , Inmunoensayo , Sistemas de Atención de Punto , SARS-CoV-2 , Anticuerpos Monoclonales Humanizados , Electrodos , Oro
12.
J Assoc Med Microbiol Infect Dis Can ; 7(3): 186-195, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36337598

RESUMEN

BACKGROUND: Serological assays designed to detect SARS-CoV-2 antibodies are being used in serological surveys and other specialized applications. As a result, and to ensure that the outcomes of serological testing meet high quality standards, evaluations are required to assess the performance of these assays and the proficiency of laboratories performing them. METHODS: A panel of 60 plasma/serum samples from blood donors who had reverse transcriptase-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 infections and 21 SARS-CoV-2 negative samples were secured and distributed to interested laboratories within Canada (n = 30) and the United States (n = 1). Participating laboratories were asked to provide details on the diagnostic assays used, the platforms the assays were performed on, and the results obtained for each panel sample. Laboratories were blinded with respect to the expected outcomes. RESULTS: The performance of the different assays evaluated was excellent, with the high-throughput platforms of Roche, Ortho, and Siemens demonstrating 100% sensitivity. Most other high-throughput platforms had sensitivities of >93%, with the exception of the IgG assay using the Abbott ARCHITECT which had an average sensitivity of only 87%. The majority of the high-throughput platforms also demonstrated very good specificities (>97%). CONCLUSION: This proficiency study demonstrates that most of the SARS-CoV-2 serological assays utilized by provincial public health or hospital laboratories in Canada have acceptable sensitivity and excellent specificity.


HISTORIQUE: Les dosages sérologiques conçus pour dépister les anticorps anti-SRAS-CoV-2 sont utilisés dans les études sérologiques et d'autres applications spécialisées. Par conséquent, et pour s'assurer que leurs résultats respectent des normes de qualité, il faut procéder à des évaluations de leur performance et de la compétence des laboratoires à les effectuer. MÉTHODOLOGIE: Les chercheurs ont obtenu une batterie de 60 prélèvements de plasma et de sérum chez des donneurs dont l'amplification en chaîne par polymérase après transcription inverse (RT-PCR) avait confirmé des infections par le SRAS-CoV-2 et de 21 prélèvements dont les résultats étaient négatifs au SRAS-CoV-2 et les ont distribués aux laboratoires intéressés du Canada (n = 30) et des États-Unis (n = 1). Ils ont invité les laboratoires participants à fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages étaient exécutés et les résultats obtenus pour chaque échantillon. Les chercheurs ont demandé aux laboratoires participants de fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages ont été effectués, et les résultats obtenus à l'égard de chaque échantillon. Les laboratoires ont mené les études à l'insu des résultats escomptés. RÉSULTATS: Les divers dosages avaient une excellente exécution, les plateformes à haut débit de Roche, d'Ortho et de Siemens démontrant une sensibilité de 100 %. La plupart des autres plateformes à haut débit avaient des sensibilités de plus de 93 %, à l'exception des dosages des IgG faisant appel à l'analyseur ARCHITECT d'Abbott, dont la sensibilité moyenne était de seulement 87 %. La majorité des plateformes à haut débit avaient également une très bonne spécificité (plus de 97 %). CONCLUSION: La présente étude de compétence démontre que la plupart des dosages sérologiques du SRAS-CoV-2 évalués dans des laboratoires sanitaires provinciaux ou les laboratoires hospitaliers du Canada possèdent une sensibilité acceptable et une excellente spécificité.

14.
J Clin Virol ; 156: 105292, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36108404

RESUMEN

The accurate measurement of serological response to SARS-CoV-2 vaccination is needed to correlate responses with effective protective immunity. The World Health Organization (WHO) has created an international standard to allow harmonization of immune response assessment to an arbitrary unit across different commercial assays; however, the accuracy of reporting of SARS-CoV-2 spike antibody titers in international standard units (BAU or IU/mL) from commercial assays is not well studied. Here, we report the performance comparison of four quantitative commercial assays testing for SARS-CoV-2 spike immunoglobins using the WHO's international standard. Sera, EDTA-plasma and heparinized plasma collected from individuals who are vaccine naïve or received BNT162b2 (Pfizer/BioNTech), mRNA-1273 (Moderna) or ChAdOx1-S (Oxford-AstraZeneca) were tested using Abbott Architect AdviseDx SARS-CoV-2 IgG II, DiaSorin LIAISON SARS-CoV-2 TrimericS IgG, Roche Elecsys Anti-SARS-CoV-2 S and GenScript cPass SARS-CoV-2 surrogate virus neutralization assays. The sensitivities ranged from 90% to 100%, and specificities from 88% to 100%. These four assays had excellent agreement (0.79-0.93) and correlation (0.87-0.97); however, Passing-Bablok regression analysis indicated that data generated by these assays were not comparable. Our data suggests that natural SARS-CoV-2 infection elicited a greater antibody response compared to vaccines, evident by a significantly higher neutralizing antibody titer in unvaccinated individuals who seroconverted.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19/diagnóstico , Vacunas contra la COVID-19 , Ácido Edético , Humanos , Inmunoglobulina G , Glicoproteína de la Espiga del Coronavirus , Organización Mundial de la Salud
15.
Sci Rep ; 12(1): 12850, 2022 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-35896795

RESUMEN

As COVID-19 waves continue to spread worldwide, demand for a portable, inexpensive and convenient biosensor to determine community immune/infection status is increasing. Here we describe an impedance-based affinity biosensor using Interdigitated Electrode (IDE) arrays to detect antibodies to SARS-CoV-2 in serum. We created the biosensor by functionalizing the IDEs' surface with abaculaovirus-expressed and purified Spike (S) protein to bind anti-SARS CoV-2antibodies. Gold nanoparticles (GNP) fused to protein G were used to probe for bound antibodies. An ELISA assay using horseradish peroxidase-protein G to probe for bound IgG confirmed that the purified S protein bound a commercial source of anti-SARS-CoV-2 antibodies specifically and bound anti-SARS-CoV-2 antibodies in COVID-19 positive serum. Then we demonstrated that our biosensor could detect anti-SARS-CoV-2 antibodies with 72% sensitivity in 2 h. Using GNP-protein G, the affinity biosensor had increased impedance changes with COVID-19positive serum and minimal or decreased impedance changes with negative serum. This demonstrated that our biosensor could discriminate between COVID-19 positive and negative sera, which were further improved using poly(vinyl alcohol)as a blocking agent.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Nanopartículas del Metal , Anticuerpos Antivirales , COVID-19/diagnóstico , Oro , Humanos , SARS-CoV-2
16.
Biosens Bioelectron X ; 11: 100176, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35692737

RESUMEN

A novel test strategy is proposed with dual-modality detection techniques for COVID-19 antibody detection. The full-length S protein of SARS-CoV-2 was chemically immobilized on a glass surface to capture anti-SARS-CoV-2 IgG in patient serum and was detected through either Electrochemical Impedance Spectroscopy (EIS) or fluorescence imaging with labeled secondary antibodies. Gold nanoparticles conjugated with protein G were used as the probe and the bound GNP-G was detected through EIS measurements. Anti-human-IgG conjugated with the fluorescent tag Alexa Fluor 488 was used as the probe for fluorescence imaging. Clinical SARS-CoV-2 IgG positive serum and negative controls were used to validate both modalities. For fluorescence-based detection, a high sensitivity was noticed with a quantification range of 0.01-0.1 A.U.C. and a LOD of 0.004 A.U.C. This study demonstrates the possibility of utilizing different measurement techniques in conjunction for improved COVID-19 serology testing.

17.
Infect Dis (Lond) ; 54(9): 666-676, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35642330

RESUMEN

BACKGROUND: The COVID-19 pandemic has necessitated the need to rapidly make public health decisions. We systematically evaluated SARS-CoV-2 seropositivity to understand local COVID-19 epidemiology and support evidence-based public health decision making. METHODS: Residual blood samples were collected for SARS-CoV-2 receptor binding domain (RBD) IgG testing over a 1-5 day period monthly from 26 February 2021-9 July 2021 from six clinical laboratories across the province of Alberta, Canada. Monthly crude and adjusted (for age and gender) seropositivity were calculated. Results were linked to provincial administrative, laboratory, and vaccine databases. RESULTS: 60,632 individual blood samples were tested. Vaccination data were available for 98.8% of samples. Adjusted RBD IgG positivity rose from 11.9% (95% confidence interval [CI] 11.9-12.0%) in March 2021 to 70.2% (95% CI 70.2-70.3%) in July 2021 (p < .0001). Seropositivity rose from 9.4% (95% CI 9.3-9.4%) in March 2021 to 20.2% (95% CI 20.1-20.2%) in July 2021 in unvaccinated Albertans. Unvaccinated seropositive individuals were from geographic areas with significantly (p < .001) lower median household income, lower proportion of married/common-law relationships, larger average household size and higher proportions of visible minorities compared to seronegative unvaccinated individuals. In July 2021, the age groups with the lowest and highest seropositivity in unvaccinated Albertans were those ≥80 years (12.0%, 95% CI 5.3-18.6%) and 20-29 years (24.2%, 95% CI 19.6-28.8%), respectively. Of seropositive unvaccinated individuals, 50.2% (95% CI 45.9-54.5%) had no record of prior SARS-CoV-2 molecular testing. CONCLUSIONS: Longitudinal surveillance of SARS-CoV-2 seropositivity with data linkage is valuable for decision-making during the pandemic.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anciano de 80 o más Años , Alberta/epidemiología , Anticuerpos Antivirales , COVID-19/epidemiología , COVID-19/prevención & control , Humanos , Inmunoglobulina G , Pandemias , Vacunación
18.
Biosens Bioelectron ; 213: 114476, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35716642

RESUMEN

Coronavirus disease 2019 (COVID-19) has caused significant global morbidity and mortality. The serology test that detects antibodies against the disease causative agent, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has often neglected value in supporting immunization policies and therapeutic decision-making. The ELISA-based antibody test is time-consuming and bulky. This work described a gold micro-interdigitated electrodes (IDE) biosensor for COVID antibody detection based on Electrochemical Impedance Spectroscopy (EIS) responses. The IDE architecture allows easy surface modification with the viral structure protein, Spike (S) protein, in the gap of the electrode digits to selectively capture anti-S antibodies in buffer solutions or human sera. Two strategies were employed to resolve the low sensitivity issue of non-faradic impedimetric sensors and the sensor fouling phenomenon when using the serum. One uses secondary antibody-gold nanoparticle (AuNP) conjugates to further distinguish anti-S antibodies from the non-specific binding and obtain a more significant impedance change. The second strategy consists of increasing the concentration of target antibodies in the gap of IDEs by inducing an AC electrokinetic effect such as dielectrophoresis (DEP). AuNP and DEP methods reached a limit of detection of 200 ng/mL and 2 µg/mL, respectively using purified antibodies in buffer, while the DEP method achieved a faster testing time of only 30 min. Both strategies could qualitatively distinguish COVID-19 antibody-positive and -negative sera. Our work, especially the impedimetric detection of COVID-19 antibodies under the assistance of the DEP force presents a promising path toward rapid, point-of-care solutions for COVID-19 serology tests.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Nanopartículas del Metal , Técnicas Biosensibles/métodos , COVID-19/diagnóstico , Electrodos , Oro/química , Humanos , Nanopartículas del Metal/química , SARS-CoV-2
19.
CMAJ Open ; 10(1): E137-E145, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35193878

RESUMEN

BACKGROUND: SARS-CoV-2 can cause outbreaks in community- and hospital-based settings. The aim of this study was to provide a detailed epidemiologic account of a hospital-wide SARS-CoV-2 outbreak and provide a description of case evaluations, transmission networks and the interventions implemented to stem the outbreak. METHODS: We conducted a retrospective descriptive study of a hospital-wide SARS-CoV-2 outbreak at the Misericordia Community Hospital (Edmonton) from June 21 to Aug. 14, 2020. We reviewed hospital chart, public health and occupational health records to determine demographics, case type (community- or hospital-acquired), need for critical care and outcome for each case linked to the outbreak (patients, hospital staff, and community and patient visitors). We developed detailed transmission networks using epidemiologic data to determine what variables may have contributed to transmission. RESULTS: Fifty-eight cases of SARS-CoV-2 infection were linked to this hospital outbreak (31 patients, 25 staff members and 2 visitors; 66% female, age range 19-97 years). One patient required critical care, and 11 deaths were recorded (all among inpatients). Most cases were hospital-acquired (91%), and 28% were asymptomatic at the time of diagnosis. The outbreak was composed of 2 clusters driven by protective equipment breaches, premature removal of precautions, transmission in small staff quarters and infection of a staff member after exposure to a wandering patient with dementia and asymptomatic, undetected SARS-CoV-2 infection. INTERPRETATION: A detailed epidemiologic review of this hospital-wide outbreak shows that a SARS-CoV-2 outbreak can involve complex transmission chains and clusters. Multipronged bundled approaches, aggressive contact tracing, and patient and staff prevalence screening are important to help bring such outbreaks under control, along with ongoing vigilance in detecting delayed cases.


Asunto(s)
COVID-19/epidemiología , COVID-19/virología , Brotes de Enfermedades , SARS-CoV-2 , Centros de Atención Terciaria , COVID-19/transmisión , Canadá/epidemiología , Trazado de Contacto , Infección Hospitalaria , Femenino , Personal de Salud , Hospitales Comunitarios , Humanos , Masculino , Prevalencia , Vigilancia en Salud Pública , Estudios Retrospectivos
20.
J Virol Methods ; 301: 114468, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35051444

RESUMEN

The processing of swabs for respiratory virus detection involves vortexing while still in the viral transport medium (VTM). The effect of not vortexing swabs prior to analysis has not been studied extensively for SARS-CoV-2 detection, and presents an opportunity to improve pre-analytic laboratory workflow. We aimed to assess the impact of not vortexing nasopharyngeal/throat swabs submitted in VTM for SARS-CoV-2 testing. To assess the impact of not vortexing swabs, 277 swab samples were tested for SARS-CoV-2 RNA in paired vortexed and non-vortexed aliquots using eight routine nucleic acid amplification assays. We compared the qualitative (positive/negative) and semi-quantitative (cycle threshold, Ct) results. Following discordant analysis, all but one non-vortexed sample had the same qualitative result as the vortexed sample. 27.4 % of samples were SARS-CoV-2 positive. Comparison of Ct values revealed an apparent reduction in human cellular nucleic acid in the non-vortexed samples (mean Ct values of 24.0 and 26.5 for vortexed and non-vortexed samples, respectively, p < 0.0001) and increased Ct values for non-vortexed samples using a laboratory-developed SARS-CoV-2 assay (mean Ct values of 4.1 and 4.2 for vortexed and non-vortexed samples, respectively; p < 0.0001), but this was not observed for a more automated commercial SARS-CoV-2 assay (mean Ct values of 15.2 for both vortexed and non-vortexed samples, respectively; p = 0.68). While vortexing swabs appears to improve the recovery of cellular material, it does not have an appreciable impact on the qualitative sensitivity of SARS-CoV-2 nucleic acid tests, which may support omission of this step and simplification of front-end sample processing.


Asunto(s)
COVID-19 , SARS-CoV-2 , Prueba de COVID-19 , Humanos , Nasofaringe , Faringe , Proyectos Piloto , ARN Viral/genética , Manejo de Especímenes/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...