Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Nucl Med ; 48(3): e147-e148, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36327463

RESUMEN

ABSTRACT: A 61-year-old man presented with papillary thyroid cancer in radioiodine-refractory status after high-activity 131 I treatments following thyroidectomy. FDG-avid neck and pulmonary metastases but without 131 I-uptake were detected. CCDC6-RET fusion was identified from the tumor lesion. He was treated with pralsetinib, a RET inhibitor, followed by another high-activity 131 I therapy. Posttherapeutic scan displayed restoration of 131 I avidity at those lesions only shown on previous FDG PET/CT. Reduced FDG avidity of those lesions and decreased serum antithyroglobulin antibody titer were also noticed. This case illustrated successfully reinduced 131 I avidity in papillary thyroid cancer through redifferentiation with target therapy to suppress tumor RET overexpression.


Asunto(s)
Radioisótopos de Yodo , Neoplasias de la Tiroides , Masculino , Humanos , Persona de Mediana Edad , Radioisótopos de Yodo/uso terapéutico , Cáncer Papilar Tiroideo/tratamiento farmacológico , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Glucosa , Neoplasias de la Tiroides/patología , Proteínas Proto-Oncogénicas c-ret
2.
Clin Nucl Med ; 47(1): 68-69, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34034324

RESUMEN

ABSTRACT: We report the accumulation of 99mTc-TRODAT-1 in the region of subacute cerebral ischemic infarction in an 81-year-old woman with Parkinson disease. The dopamine transporter SPECT imaging was performed on the 15th day after the onset of acute cerebral ischemic clinical symptoms. Overexpression of dopamine transporters after infarction in subacute phase may explain the accumulation.


Asunto(s)
Enfermedad de Parkinson , Anciano de 80 o más Años , Encéfalo/diagnóstico por imagen , Infarto Cerebral/diagnóstico por imagen , Femenino , Humanos , Compuestos de Organotecnecio , Enfermedad de Parkinson/diagnóstico por imagen , Tropanos
3.
J Clin Med ; 10(17)2021 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-34501480

RESUMEN

(1) Background: This study aimed to investigate the association between radioactive iodine (RAI) and long-term cardiovascular disease (CVD) morbidity/mortality in thyroid cancer. (2) Methods: The study was conducted using data from the Taiwan National Health Insurance Database during 2000-2015. Thyroid cancer patients aged ≥20 years were categorized into RAI (thyroidectomy with RAI) and non-RAI (thyroidectomy only) groups. The Cox proportional hazard regression model and Kaplan-Meier method were used for analysis. (3) Results: A total of 13,310 patients were included. Kaplan-Meier analysis demonstrated that the two groups had similar cumulative risks of CVD (log-rank p = 0.72) and CVD-specific mortality (log-rank p = 0.62). On Cox regression analysis of different RAI doses, the risk of CVD was higher in the cumulative dosage >3.7 GBq (hazard ratio = 1.69, 95% confidence interval = 1.24-2.40, p < 0.001). (4) Conclusions: RAI was not associated with an increased risk of CVD in thyroid cancer. However, CVD surveillance is indicated in the patients receiving the cumulative RAI dosage above 3.7 GBq.

4.
Biomed Eng Online ; 17(Suppl 2): 157, 2018 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-30396347

RESUMEN

BACKGROUND: Pressure sensors have been used for sleeping posture detection, which meet privacy requirements. Most of the existing techniques for sleeping posture recognition used force-sensitive resistor (FSR) sensors. However, lower limbs cannot be recognized accurately unless thousands of sensors are deployed on the bedsheet. METHOD: We designed a sleeping posture recognition scheme in which FSR sensors were deployed on the upper part of the bedsheet to record the pressure distribution of the upper body. In addition, an infrared array sensor was deployed to collect data for the lower body. Posture recognition was performed using a fuzzy c-means clustering algorithm. Six types of sleeping body posture were recognized from the combination of the upper and lower body postures. RESULTS: The experimental results showed that the proposed method achieved an accuracy of above 88%. Moreover, the proposed scheme is cost-efficient and easy to deploy. CONCLUSIONS: The proposed sleeping posture recognition system can be used for pressure ulcer prevention and sleep quality assessment. Compared to wearable sensors and cameras, FSR sensors and infrared array sensors are unobstructed and meet privacy requirements. Moreover, the proposed method provides a cost-effective solution for the recognition of sleeping posture.


Asunto(s)
Lógica Difusa , Monitoreo Ambulatorio/instrumentación , Postura , Sueño/fisiología , Análisis por Conglomerados , Humanos , Presión , Procesamiento de Señales Asistido por Computador
5.
Technol Health Care ; 26(1): 11-16, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29060949

RESUMEN

BACKGROUND: Typical radio frequency identification (RFID) access control system can be ineffective if an unauthorized person tailgates an authorized person through an access area. OBJECTIVE: To propose a system by using indoor locating and tracking techniques address this problem, which is to prevent unauthorized Alzheimer's and dementia patients from getting lost including by tailgating. METHODS: To achieve accurate target location, passive RFID deployment strategy is studied and a fingerprinting based passive RFID localization algorithm is proposed. The proposed system was evaluated in a building environment to simulate the performance of access control. RFID reader was installed on ceiling near the access area and tags were stitched on both shoulders of the experiment subject's garments. RESULTS: The probability of the error distance within 0.3 m achieved 97% in the warning area; the location precision achieved 97% within 0.4 m in the monitoring area. CONCLUSIONS: The result showed that if an unauthorized person enters the restricted area, the system can initiate an alert signal accurately. Therefore, the proposed system is very suitable to be used in nursing home or hospital to prevent unauthorized personnel and assets entering/exiting a confined location.


Asunto(s)
Demencia/epidemiología , Hogares para Ancianos/organización & administración , Casas de Salud/organización & administración , Dispositivo de Identificación por Radiofrecuencia/métodos , Algoritmos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...