Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Intervalo de año de publicación
1.
Braz J Cardiovasc Surg ; 38(6): e20220463, 2023 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-37801428

RESUMEN

INTRODUCTION: The aim of this study is to compare the postoperative outcomes and early mortality of peripheral and central cannulation techniques in cardiac reoperations using propensity score matching analysis. METHODS: In this retrospective cohort, patients who underwent cardiac reoperations with median resternotomy were analyzed in terms of propensity score matching. Between November 2010 and September 2020, 257 patients underwent cardiac reoperations via central (Group 1) or peripheral (Group 2) cannulation. A 1:1 propensity score matching was performed to balance the influence of potential confounding factors to compare postoperative data and mortality rate. RESULTS: There were no significant differences when comparing the matched groups regarding early mortality (P=0.51), major cardiac injury (P=0.99), prolonged ventilation (P=0.16), and postoperative stroke (P=0.99). The development of acute renal failure (P=0.02) was statistically less frequent in Group 1. CONCLUSIONS: Performing cardiopulmonary bypass via peripheral cannulation increases acute renal failure in cardiac reoperations. In contrast, peripheral or central cannulation have similar early mortality rate in cardiac reoperations.


Asunto(s)
Lesión Renal Aguda , Cateterismo , Humanos , Estudios Retrospectivos , Puntaje de Propensión , Resultado del Tratamiento , Lesión Renal Aguda/etiología , Complicaciones Posoperatorias
2.
Braz J Cardiovasc Surg ; 38(6): e20220257, 2023 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-37801681

RESUMEN

INTRODUCTION: This study aimed to investigate the factors affecting false lumen patency in the descending thoracic aorta among patients who underwent surgery for acute type 1 aortic dissection. METHODS: A total of 112 patients with acute type 1 aortic dissection, with the flap below the diaphragm level, underwent surgery between January 2010 and September 2019. Of these, 60 patients who were followed up for ≥ 12 months and whose computed tomography scans were available were included in this study. The patients were divided into two groups: group I, consists of patent false lumen (n=36), and group II, consists of thrombosed false lumen (n=24). Demographic data, operative techniques, postoperative descending aortic diameters, reintervention, and late mortality were compared between the two groups. RESULTS: The mean follow-up period of all patients was 37.6±26.1 months (range: 12-104). The diameter increase in the proximal and distal descending aorta was significantly higher in the patent false lumen group (5.3±3.7 mm vs. 3.25±2.34 mm; P=0.015; 3.1±2.52 mm vs. 1.9±1.55 mm; P=0.038, respectively). No significant difference in terms of hypertension was found between the two groups during the follow-up period (21 patients, 58.3% vs. 8 patients, 33.3%; P=0.058). A total of 29 patients (48.3%) were found to be hypertensive in the postoperative period. CONCLUSION: After surgical treatment for acute type 1 aortic dissection, patients should be monitored closely, regardless of whether the false lumen is patent or thrombosed. Mortality and reintervention can be seen in patients with patent false lumen during follow-up.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Resultado del Tratamiento , Enfermedad Aguda , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Estudios Retrospectivos
3.
Innovations (Phila) ; 18(5): 466-471, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37705309

RESUMEN

OBJECTIVE: Pannus overgrowth is a chronic inflammatory process that can cause valve dysfunction and threaten the durability of prosthetic valves. Bileaflet mechanical mitral valve can be implanted in either an anatomical (parallel to the anatomical axis) or nonanatomical (perpendicular or oblique to the anatomical axis) orientation. The effect of the rotational orientation of the bileaflet mechanical mitral valve on excessive pannus enlargement is unknown. The present study compared the effect of bileaflet mechanical mitral valve orientation on pannus overgrowth. METHODS: The study included patients who underwent bileaflet mechanical mitral valve replacement for rheumatic mitral valve stenosis. The pannus formation was confirmed by reexamining all transesophageal echocardiography images in the picture archiving and communication systems between May 2017 and April 2021. The primary aim of this study was the development of pannus overgrowth. Patients were divided into 2 groups based on their implantation orientation of the bileaflet mechanical mitral valve. RESULTS: Pannus overgrowth was found in 26 patients (56.5%) in the anatomical orientation group and 71 patients (74.7%) in the nonanatomical orientation group (P = 0.03). Anatomical orientation reduced the development of pannus overgrowth (odds ratio [OR] = 0.39, P = 0.04), and double left heart valve replacement increased the development of pannus overgrowth (OR = 2.73, P = 0.04). CONCLUSIONS: Pannus overgrowth was less common in bileaflet mechanical mitral valves implanted in the anatomical orientation.

4.
Turk Gogus Kalp Damar Cerrahisi Derg ; 31(1): 45-55, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36926147

RESUMEN

Background: In this systematic review, we aimed to examine the risk factors and surgical outcomes of gastrointestinal complications using the meta-analysis techniques. Methods: Studies involving patients with and without gastrointestinal complications after cardiac surgery were electronically searched using the PubMed database, Cochrane Library and Scopus database, between January 2000 and May 2022. Some studies on gastrointestinal complications examined only single gastrointestinal complication (only intestinal ischemia, only gastrointestinal bleeding or only liver failure). Studies evaluating at least three different gastrointestinal complications were included in the meta-analysis to reduce the heterogeneity. Cohort series that did not compare outcomes of patients with and without gastrointestinal complications, studies conducted in a country"s health system databases, review articles, small case series (<10 patients) were excluded from the meta-analysis. Results: Twenty-five studies (8 prospective and 17 retrospective) with 116,105 patients were included in the meta-analysis. The pooled incidence of gastrointestinal complications was 2.51%. Patients with gastrointestinal complications were older (mean difference [MD]=4.88 [95% confidence interval [CI]: 2.85-6.92]; p<0.001) and had longer cardiopulmonary bypass times (MD=17.7 [95% CI: 4.81-30.5]; p=0.007). In-hospital mortality occurred in 423 of 1,640 (25.8%) patients with gastrointestinal complications. In-hospital mortality was 11.8 times higher in patients with gastrointestinal complications (odds ratio [OR]=11.8 [95% CI: 9.5-14.8]; p<0.001). Conclusion: The development of gastrointestinal complications after cardiac surgery is more commonly seen in patients with comorbidities. In-hospital mortality after cardiac surgery is 11.8 times higher in patients with gastrointestinal complications than in patients without.

5.
Indian J Thorac Cardiovasc Surg ; 39(1): 6-13, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36590040

RESUMEN

Purpose: Stanford type A aortic dissection (TAAD) is the most common and fatal type of dissection. An easier-to-use risk stratification may help eliminate bias in patients at high risk of dissection. The age, serum creatinine, and ejection fraction (ACEF) score is a simple risk model developed to predict the mortality risk of elective coronary artery bypass graft surgery. This study aimed to evaluate the relationship between preoperative ACEF score and operative mortality in patients with TAAD undergoing emergency surgery. Methods: In this retrospective cohort study, 113 patients diagnosed with TAAD between January 2017 and September 2021 were evaluated. The primary endpoint was operative mortality. Receiver operating characteristic analysis was performed for the ACEF score, ACEF II score, and European System for Cardiac Operative Risk Evaluation II. Univariate and multivariate analyses of operative mortality were performed using the logistic regression model. Results: Operative mortality occurred in 23 (20.4%) patients. The cutoff ACEF score was calculated as 1.1 for predicting operative mortality (area under the curve = 0.712, P value = 0.002, sensitivity = 74.0%, specificity = 67.8%, likelihood ratio = 2.3). Based on the cutoff value, 46 (40.7%) patients had a high ACEF score (ACEF ≥ 1.1) and 67 (59.3%) patients had a low ACEF score (ACEF < 1.1). The high ACEF score was associated with an increased incidence of operative mortality compared with the low ACEF score (37.0% vs. 9.0%; P = 0.001). Conclusions: The ACEF score can be used as a useful and relatively simple tool for risk stratification before TAAD surgery. However, the ACEF score is only indicated for risk assessment and should not affect treatment.

6.
Rev. bras. cir. cardiovasc ; 38(6): e20220463, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1521665

RESUMEN

ABSTRACT Introduction: The aim of this study is to compare the postoperative outcomes and early mortality of peripheral and central cannulation techniques in cardiac reoperations using propensity score matching analysis. Methods: In this retrospective cohort, patients who underwent cardiac reoperations with median resternotomy were analyzed in terms of propensity score matching. Between November 2010 and September 2020, 257 patients underwent cardiac reoperations via central (Group 1) or peripheral (Group 2) cannulation. A 1:1 propensity score matching was performed to balance the influence of potential confounding factors to compare postoperative data and mortality rate. Results: There were no significant differences when comparing the matched groups regarding early mortality (P=0.51), major cardiac injury (P=0.99), prolonged ventilation (P=0.16), and postoperative stroke (P=0.99). The development of acute renal failure (P=0.02) was statistically less frequent in Group 1. Conclusions: Performing cardiopulmonary bypass via peripheral cannulation increases acute renal failure in cardiac reoperations. In contrast, peripheral or central cannulation have similar early mortality rate in cardiac reoperations.

7.
Rev. bras. cir. cardiovasc ; 38(6): e20220257, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1521669

RESUMEN

ABSTRACT Introduction: This study aimed to investigate the factors affecting false lumen patency in the descending thoracic aorta among patients who underwent surgery for acute type 1 aortic dissection. Methods: A total of 112 patients with acute type 1 aortic dissection, with the flap below the diaphragm level, underwent surgery between January 2010 and September 2019. Of these, 60 patients who were followed up for ≥ 12 months and whose computed tomography scans were available were included in this study. The patients were divided into two groups: group I, consists of patent false lumen (n=36), and group II, consists of thrombosed false lumen (n=24). Demographic data, operative techniques, postoperative descending aortic diameters, reintervention, and late mortality were compared between the two groups. Results: The mean follow-up period of all patients was 37.6±26.1 months (range: 12-104). The diameter increase in the proximal and distal descending aorta was significantly higher in the patent false lumen group (5.3±3.7 mm vs. 3.25±2.34 mm; P=0.015; 3.1±2.52 mm vs. 1.9±1.55 mm; P=0.038, respectively). No significant difference in terms of hypertension was found between the two groups during the follow-up period (21 patients, 58.3% vs. 8 patients, 33.3%; P=0.058). A total of 29 patients (48.3%) were found to be hypertensive in the postoperative period. Conclusion: After surgical treatment for acute type 1 aortic dissection, patients should be monitored closely, regardless of whether the false lumen is patent or thrombosed. Mortality and reintervention can be seen in patients with patent false lumen during follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...