Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Animal Model Exp Med ; 7(2): 156-165, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38506157

RESUMEN

INTRODUCTION: Hypoxic pulmonary vasoconstriction (HPV) can be a challenging clinical problem. It is not fully elucidated where in the circulation the regulation of resistance takes place. It is often referred to as if it is in the arteries, but we hypothesized that it is in the venous side of the pulmonary circulation. METHODS: In an open thorax model, pigs were treated with a veno-venous extra corporeal membrane oxygenator to either oxygenate or deoxygenate blood passing through the pulmonary vessels. At the same time the lungs were ventilated with extreme variations of inspired air from 5% to 100% oxygen, making it possible to make combinations of high and low oxygen content through the pulmonary circulation. A flow probe was inserted around the main pulmonary artery and catheters in the pulmonary artery and in the left atrium were used for pressure monitoring and blood tests. Under different combinations of oxygenation, pulmonary vascular resistance (PVR) was calculated. RESULTS: With unchanged level of oxygen in the pulmonary artery and reduced inspired oxygen fraction lowering oxygen tension from 29 to 6.7 kPa in the pulmonary vein, PVR was doubled. With more extreme hypoxia PVR suddenly decreased. Combinations with low oxygenation in the pulmonary artery did not systematic influence PVR if there was enough oxygen in the inspired air and in the pulmonary veins. DISCUSSION: The impact of hypoxia occurs from the alveolar level and forward with the blood flow. The experiments indicated that the regulation of PVR is mediated from the venous side.


Asunto(s)
Hipoxia , Oxígeno , Arteria Pulmonar , Venas Pulmonares , Resistencia Vascular , Animales , Arteria Pulmonar/fisiopatología , Hipoxia/fisiopatología , Oxígeno/metabolismo , Oxígeno/sangre , Porcinos , Circulación Pulmonar , Vasoconstricción
2.
BMC Pulm Med ; 24(1): 23, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38195463

RESUMEN

BACKGROUND: Flexible bronchoscopy procedures require detailed anatomical knowledge and advanced technical skills. Simulation-based training offers a patient-safe training environment that can be more efficient than patient-based training. Physical models are cheaper than virtual reality simulators and allow trainees to be acquainted with the equipment used in the clinic. The choice of a physical model for training depends on the local context. The aim of this study was to compare four different bronchoscopy models for flexible bronchoscopy training. METHODS: The BronchoBoy manikin, the Koken manikin, a human cadaver, and a preserved porcine lung were included in the study. Seven physicians experienced in bronchoscopy performed a bronchoscopic airway inspection, bronchoalveolar lavage (BAL), and tissue sampling on all four models with performance evaluated by observation and participant evaluation of models by questionnaire. RESULTS: Nineteen segments were identified in all human anatomy models, and the only significant difference found was that only the Thiel embedded cadaver allowed all participants to enter RB1 with an instrument in the working channel (p = 0.001). The Thiel embedded cadaver and the BronchoBoy manikin had low fluid return on BAL (22 and 52 ml), whereas the Koken manikin and the preserved porcine lung had high return (132 and 134 ml), (p = 0.017). Tissue samplings were only completed in the preserved porcine lung and the Thiel embedded cadaver (p < 0.001). CONCLUSIONS: An anatomically correct bronchoscopy is best simulated with the Koken manikin or the Thiel embedded cadaver. Bronchoalveolar lavage should be simulated with the Koken manikin or the preserved porcine lung. Tissue sampling procedures are best simulated using the Thiel embedded cadaver or the preserved porcine lung.


Asunto(s)
Broncoscopía , Dimercaprol , Porcinos , Animales , Humanos , Lavado Broncoalveolar , Cadáver , Maniquíes
3.
Intensive Care Med Exp ; 11(1): 41, 2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37415048

RESUMEN

BACKGROUND: Diaphragmatic dysfunction is well documented in patients receiving mechanical ventilation. Inspiratory muscle training (IMT) has been used to facilitate weaning by strengthening the inspiratory muscles, yet the optimal approach remains uncertain. Whilst some data on the metabolic response to whole body exercise in critical care exist, the metabolic response to IMT in critical care is yet to be investigated. This study aimed to quantify the metabolic response to IMT in critical care and its relationship to physiological variables. METHODS: We conducted a prospective observational study on mechanically ventilated patients ventilated for ≥ 72 h and able to participate in IMT in a medical, surgical, and cardiothoracic intensive care unit. 76 measurements were taken on 26 patients performing IMT using an inspiratory threshold loading device at 4 cmH2O, and at 30, 50 and 80% of their negative inspiratory force (NIF). Oxygen consumption (VO2) was measured continuously using indirect calorimetry. RESULTS: First session mean (SD) VO2 was 276 (86) ml/min at baseline, significantly increasing to 321 (93) ml/min, 333 (92) ml/min, 351(101) ml/min and 388 (98) ml/min after IMT at 4 cmH2O and 30, 50 and 80% NIF, respectively (p = 0.003). Post hoc comparisons revealed significant differences in VO2 between baseline and 50% NIF and baseline and 80% NIF (p = 0.048 and p = 0.001, respectively). VO2 increased by 9.3 ml/min for every 1 cmH2O increase in inspiratory load from IMT. Every increase in P/F ratio of 1 decreased the intercept VO2 by 0.41 ml/min (CI - 0.58 to - 0.24 p < 0.001). NIF had a significant effect on the intercept and slope, with every 1 cmH2O increase in NIF increasing intercept VO2 by 3.28 ml/min (CI 1.98-4.59 p < 0.001) and decreasing the dose-response slope by 0.15 ml/min/cmH2O (CI - 0.24 to - 0.05 p = 0.002). CONCLUSIONS: IMT causes a significant load-dependent increase in VO2. P/F ratio and NIF impact baseline VO2. The dose-response relationship of the applied respiratory load during IMT is modulated by respiratory strength. These data may offer a novel approach to prescription of IMT. TAKE HOME MESSAGE: The optimal approach to IMT in ICU is uncertain; we measured VO2 at different applied respiratory loads to assess whether VO2 increased proportionally with load and found VO2 increased by 9.3 ml/min for every 1 cmH2O increase in inspiratory load from IMT. Baseline NIF has a significant effect on the intercept and slope, participants with a higher baseline NIF have a higher resting VO2 but a less pronounced increase in VO2 as the inspiratory load increases; this may offer a novel approach to IMT prescription. Trial registration ClinicalTrials.gov, registration number: NCT05101850. Registered on 28 September 2021, https://clinicaltrials.gov/ct2/show/NCT05101850.

4.
Respir Care ; 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36347564

RESUMEN

BACKGROUND: COVID-19-related ARDS is characterized by severe hypoxemia with initially preserved lung compliance and impaired ventilation/perfusion (V̇/Q̇) matching. PEEP can increase end-expiratory lung volume, but its effect on V̇/Q̇ mismatch in COVID-19-related ARDS is not clear. METHODS: We enrolled intubated and mechanically ventilated subjects with COVID-19 ARDS and used the automatic lung parameter estimator (ALPE) to measure V̇/Q̇. Respiratory mechanics measurements, shunt, and V̇/Q̇ mismatch (low V̇/Q̇ and high V̇/Q̇) were collected at 3 PEEP levels (clinical PEEP = intermediate PEEP, low PEEP [clinical - 50%], and high PEEP [clinical + 50%]). A mixed-effect model was used to evaluate the impact of PEEP on V̇/Q̇. We also investigated if PEEP might have a different effect on V̇/Q̇ mismatch in 2 different respiratory mechanics phenotypes, that is, high elastance/low compliance (phenotype H) and low elastance/high compliance (phenotype L). RESULTS: Seventeen subjects with COVID-related ARDS age 66 [60-71] y with a PaO2 /FIO2 of 141 ± 74 mm Hg were studied at low PEEP = 5.6 ± 2.2 cm H2O, intermediate PEEP = 10.6 ± 3.8 cm H2O, and high PEEP = 15 ± 5 cm H2O. Shunt, low V̇/Q̇, high V̇/Q̇, and alveolar dead space were not significantly influenced, on average, by PEEP. Respiratory system compliance decreased significantly when increasing PEEP without significant variation of PaO2 /FIO2 (P = .26). In the 2 phenotypes, PEEP had opposite effects on shunt, with a decrease in the phenotype L and an increase in phenotype H (P = .048). CONCLUSIONS: In subjects with COVID-related ARDS placed on invasive mechanical ventilation for > 48 h, PEEP had a heterogeneous effect on V̇/Q̇ mismatch and, on average, higher levels were not able to reduce shunt. The subject's compliance could influence the effect of PEEP on V̇/Q̇ mismatch since an increased shunt was observed in subjects with lower compliance, whereas the opposite occurred in those with higher compliance.

5.
Biomed Eng Online ; 21(1): 5, 2022 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-35073928

RESUMEN

BACKGROUND: Systems aiding in selecting the correct settings for mechanical ventilation should visualize patient information at an appropriate level of complexity, so as to reduce information overload and to make reasoning behind advice transparent. Metaphor graphics have been applied to this effect, but these have largely been used to display diagnostic and physiologic information, rather than the clinical decision at hand. This paper describes how the conflicting goals of mechanical ventilation can be visualized and applied in making decisions. Data from previous studies are analyzed to assess whether visual patterns exist which may be of use to the clinical decision maker. MATERIALS AND METHODS: The structure and screen visualizations of a commercial clinical decision support system (CDSS) are described, including the visualization of the conflicting goals of mechanical ventilation represented as a hexagon. Retrospective analysis is performed on 95 patients from 2 previous clinical studies applying the CDSS, to identify repeated patterns of hexagon symbols. RESULTS: Visual patterns were identified describing optimal ventilation, over and under ventilation and pressure support, and over oxygenation, with these patterns identified for both control and support modes of mechanical ventilation. Numerous clinical examples are presented for these patterns illustrating their potential interpretation at the bedside. CONCLUSIONS: Visual patterns can be identified which describe the trade-offs required in mechanical ventilation. These may have potential to reduce information overload and help in simple and rapid identification of sub-optimal settings.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Respiración Artificial , Toma de Decisiones , Humanos , Respiración con Presión Positiva , Estudios Retrospectivos
6.
J Clin Monit Comput ; 35(5): 1149-1157, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-32816177

RESUMEN

During one-lung ventilation (OLV), titrating the positive end-expiratory pressure (PEEP) to target a low driving pressure (∆P) could reduce postoperative pulmonary complications. However, it is unclear how to conduct PEEP titration: by stepwise increase starting from zero PEEP (PEEPINCREMENTAL) or by stepwise decrease after a lung recruiting manoeuvre (PEEPDECREMENTAL). In this randomized trial, we compared the physiological effects of these two PEEP titration strategies on respiratory mechanics, ventilation/perfusion mismatch and gas exchange. Patients undergoing video-assisted thoracoscopic surgery in OLV were randomly assigned to a PEEPINCREMENTAL or PEEPDECREMENTAL strategy to match the lowest ∆P. In the PEEPINCREMENTAL group, PEEP was stepwise titrated from ZEEP up to 16 cm H2O, whereas in the PEEPDECREMENTAL group PEEP was decrementally titrated, starting from 16 cm H2O, immediately after a lung recruiting manoeuvre. Respiratory mechanics, ventilation/perfusion mismatch and blood gas analyses were recorded at baseline, after PEEP titration and at the end of surgery. Sixty patients were included in the study. After PEEP titration, shunt decreased similarly in both groups, from 50 [39-55]% to 35 [28-42]% in the PEEPINCREMENTAL and from 45 [37-58]% to 33 [25-45]% in the PEEPDECREMENTAL group (both p < 0.001 vs baseline). The resulting ∆P, however, was lower in the PEEPDECREMENTAL than in the PEEPINCREMENTAL group (8 [7-11] vs 10 [9-11] cm H2O; p = 0.03). In the PEEPDECREMENTAL group the PaO2/ FIO2 ratio increased significantly after intervention (from 140 [99-176] to 186 [152-243], p < 0.001). Both the PEEPINCREMENTAL and the PEEPDECREMENTAL strategies were able to decrease intraoperative shunt, but only PEEPDECREMENTAL improved oxygenation and lowered intraoperative ΔP.Clinical trial number NCT03635281; August 2018; "retrospectively registered".


Asunto(s)
Ventilación Unipulmonar , Humanos , Pulmón , Rendimiento Pulmonar , Respiración con Presión Positiva , Mecánica Respiratoria
7.
Int J Sports Med ; 41(10): 661-668, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32455456

RESUMEN

The purpose of this study was to investigate the correlation between the seismocardiogram and cardiorespiratory fitness. Cardiorespiratory fitness can be estimated as VO2max using non-exercise algorithms, but the results can be inaccurate. Healthy subjects were recruited for this study. Seismocardiogram and electrocardiogram were recorded at rest. VO2max was measured during a maximal effort cycle ergometer test. Amplitudes and timing intervals were extracted from the seismocardiogram and used in combination with demographic data in a non-exercise prediction model for VO2max. 26 subjects were included, 17 females. Mean age: 38.3±9.1 years. The amplitude following the aortic valve closure derived from the seismocardiogram had a significant correlation of 0.80 (p<0.001) to VO2max. This feature combined with age, sex and BMI in the prediction model, yields a correlation to VO2max of 0.90 (p<0.001, 95% CI: 0.83-0.94) and a standard error of the estimate of 3.21 mL·kg-1·min-1 . The seismocardiogram carries information about the cardiorespiratory fitness. When comparing to other non-exercise models the proposed model performs better, even after cross validation. The model is limited when tracking changes in VO2max. The method could be used in the clinic for a more accurate estimation of VO2max compared to current non-exercise methods.


Asunto(s)
Capacidad Cardiovascular , Pruebas de Función Cardíaca/métodos , Consumo de Oxígeno , Adulto , Algoritmos , Índice de Masa Corporal , Electrocardiografía , Femenino , Humanos , Estudios Longitudinales , Masculino , Procesamiento de Señales Asistido por Computador
8.
Crit Care ; 24(1): 111, 2020 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-32293506

RESUMEN

BACKGROUND: Several studies have found only a weak to moderate correlation between oxygenation and lung aeration in response to changes in PEEP. This study aimed to investigate the association between changes in shunt, low and high ventilation/perfusion (V/Q) mismatch, and computed tomography-measured lung aeration following an increase in PEEP in patients with ARDS. METHODS: In this preliminary study, 12 ARDS patients were subjected to recruitment maneuvers followed by setting PEEP at 5 and then either 15 or 20 cmH2O. Lung aeration was measured by computed tomography. Values of pulmonary shunt and low and high V/Q mismatch were calculated by a model-based method from measurements of oxygenation, ventilation, and metabolism taken at different inspired oxygen levels and an arterial blood gas sample. RESULTS: Increasing PEEP resulted in reduced values of pulmonary shunt and the percentage of non-aerated tissue, and an increased percentage of normally aerated tissue (p < 0.05). Changes in shunt and normally aerated tissue were significantly correlated (r = - 0.665, p = 0.018). Three distinct responses to increase in PEEP were observed in values of shunt and V/Q mismatch: a beneficial response in seven patients, where shunt decreased without increasing high V/Q; a detrimental response in four patients where both shunt and high V/Q increased; and a detrimental response in a patient with reduced shunt but increased high V/Q mismatch. Non-aerated tissue decreased with increased PEEP in all patients, and hyperinflated tissue increased only in patients with a detrimental response in shunt and V/Q mismatch. CONCLUSIONS: The results show that improved lung aeration following an increase in PEEP is not always consistent with reduced shunt and V/Q mismatch. Poorly matched redistribution of ventilation and perfusion, between dependent and non-dependent regions of the lung, may explain why patients showed detrimental changes in shunt and V/Q mismatch on increase in PEEP, despite improved aeration. TRIAL REGISTRATION: ClinicalTrails.gov, NCT04067154. Retrospectively registered on August 26, 2019.


Asunto(s)
Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Relación Ventilacion-Perfusión/fisiología , Adulto , Anciano , Análisis de los Gases de la Sangre/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración con Presión Positiva/instrumentación , Estudios Prospectivos , Síndrome de Dificultad Respiratoria/complicaciones
9.
Nutr Clin Pract ; 34(5): 767-774, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30714634

RESUMEN

BACKGROUND: Indirect calorimetry (IC) is considered the accurate way of measuring energy expenditure (EE). IC devices often apply the Haldane transformation, introducing errors at inspiratory oxygen fraction (FiO2 ) >60%. The aim was to assess measurement reliability and agreement between an unevaluated IC (device 2) (Beacon Caresystem, Mermaid Care A/S, Noerresundby, Denmark) not using Haldane transformation and an IC that does (device 1) (Ecovx, GE, Helsinki, Finland) at varying FiO2 . METHODS: Twenty healthy male subjects participated, with 16 completing the study (33 ± 9 years, 83.3 ± 16 kg, 1.83 ± 0.08 m). Subjects were mechanically ventilated in pressure support (3cmH2 O; positive end-expiratory pressure: 3cmH2 O) at FiO2 of 21%, 50%, 85%, and 21% for 15 minutes at each FiO2 . Mean EE, oxygen consumption (VO2 ), and CO2 production (VCO2 ) were compared within and between devices across FiO2 levels. RESULTS: Device 2 showed within-device EE significant differences at 21% vs 50% FiO2 and device 1 for VCO2 at 50% vs. 85% FiO2 . For all variables, both devices showed reliable measurements at 21% and 50% FiO2 , but at 85%, FiO2 bias and limits of agreement increased. Between devices, there were significant differences for EE at both 21% and 85% FiO2 for VO2 and for VCO2 at 85% FiO2 . CONCLUSION: Both systems measured EE, VO2 , and VCO2 at 21%-85% FiO2 reliably but with bias at 85% FiO2 . The devices were in agreement at 21% and 50% FiO2 , but further studies need to confirm accuracy at high FiO2 .


Asunto(s)
Calorimetría Indirecta/normas , Respiración Artificial/normas , Adulto , Calorimetría Indirecta/instrumentación , Metabolismo Energético , Voluntarios Sanos , Humanos , Inhalación , Masculino , Consumo de Oxígeno , Reproducibilidad de los Resultados , Respiración Artificial/métodos
10.
J Crit Care ; 48: 407-413, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30317049

RESUMEN

PURPOSE: To assess whether a clinical decision support system (CDSS) suggests PS and FIO2 maintaining appropriate breathing effort, and minimizing FIO2. MATERIALS: Prospective, cross-over study in PS ventilated ICU patients. Over support (150% baseline) and under support (50% baseline) were applied by changing PS (15 patients) or PEEP (8 patients). CDSS advice was followed. Tension time index of inspiratory muscles (TTies), respiratory and metabolic variables were measured. RESULTS: PS over support (median 8.0 to 12.0 cmH2O) reduced respiratory muscle activity (TTies 0.090 ±â€¯0.028 to 0.049 ±â€¯0.030; p < .01), and tended to increase tidal volume (VT: 8.6 ±â€¯3.0 to 10.1 ±â€¯2.9 ml/kg; p = .08). CDSS advice reduced PS (6.0 cmH2O, p = .005), increased TTies (0.076 ±â€¯0.038, p < .01), and tended to reduce VT (8.9 ±â€¯2.4 ml/kg, p = .08). PS under support (12.0 to 4.0 cmH2O) slightly increased respiratory muscle activity, (TTies to 0.120 ±â€¯0.044; p = .007) with no significant CDSS advice. CDSS advice reduced FIO2 by 12-14% (p = .005), resulting in median SpO2 = 96% (p < .02). PEEP changes did not result in changes in physiological variables, or CDSS advice. CONCLUSION: The CDSS advised on low values of PS often not prohibiting extubation, while acting to preserve respiratory muscle function and preventing passive lung inflation. CDSS advice minimized FIO2 maintaining SpO2 at safe and beneficial values.


Asunto(s)
Técnicas de Apoyo para la Decisión , Respiración Artificial/métodos , Músculos Respiratorios/fisiopatología , Anciano , Extubación Traqueal/métodos , Análisis de Varianza , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Respiración con Presión Positiva/métodos , Estudios Prospectivos
11.
Crit Care Med ; 46(7): e642-e648, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29629989

RESUMEN

OBJECTIVES: To evaluate the physiologic effects of applying advice on mechanical ventilation by an open-loop, physiologic model-based clinical decision support system. DESIGN: Prospective, observational study. SETTING: University and Regional Hospitals' ICUs. PATIENTS: Varied adult ICU population. INTERVENTIONS: Advice were applied if accepted by physicians for a period of up to 4-8 hours. MEASUREMENTS AND MAIN RESULTS: Seventy-two patients were included for data analysis. Acceptance of advice was high with 95.7% of advice applied. In 41 patients in pressure support ventilation, following system advice led to significant decrease in PS, with PS reduced below 8 cm H2O in 15 patients (37%), a level not prohibiting extubation. Fraction of end-tidal CO2 values did not change, and increase in respiratory rate/VT was within clinical limits, indicating that in general, the system maintained appropriate patient breathing effort. In 31 patients in control mode ventilation, pressure control and tidal volume settings were decreased significantly, with tidal volume reduced below 8 mL/kg predicted body weight in nine patients (29%). Minute ventilation was maintained by a significant increase in respiratory rate. Significant reductions in FIO2 were seen on elevated baseline median values of 50% in both support and control mode-ventilated patients, causing clinically acceptable reductions in oxygen saturation. CONCLUSIONS: The results indicate that during a short period, the clinical decision support system provided appropriate suggestions of mechanical ventilation in a varied ICU population, significantly reducing ventilation to levels which might be considered safe and beneficial.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Respiración Artificial/métodos , Técnicas de Apoyo para la Decisión , Humanos , Unidades de Cuidados Intensivos , Estudios Prospectivos , Reproducibilidad de los Resultados , Fenómenos Fisiológicos Respiratorios
12.
Anesthesiology ; 128(3): 531-538, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29215365

RESUMEN

BACKGROUND: Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. METHODS: Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. RESULTS: During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P < 0.001). The PaO2/FIO2 ratio increased significantly only at a positive end-expiratory pressure of 10 cm H2O (P < 0.001). Driving pressure decreased from 16 ± 3 cm H2O at a positive end-expiratory pressure of 0 cm H2O to 12 ± 3 cm H2O at a positive end-expiratory pressure of 10 cm H2O (P < 0.001). The high V/Q ratio did not change. CONCLUSIONS: During low VT one-lung ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.


Asunto(s)
Pulmón/fisiología , Ventilación Unipulmonar/métodos , Respiración con Presión Positiva/métodos , Mecánica Respiratoria/fisiología , Anciano , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Intercambio Gaseoso Pulmonar/fisiología , Volumen de Ventilación Pulmonar/fisiología
13.
Simul Healthc ; 12(6): 349-355, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28825930

RESUMEN

INTRODUCTION: Advances in knowledge regarding mechanical ventilation (MV), in particular lung-protective ventilation strategies, have been shown to reduce mortality. However, the translation of these advances in knowledge into better therapeutic performance in real-life clinical settings continues to lag. High-fidelity simulation with a mannequin allows students to interact in lifelike situations; this may be a valuable addition to traditional didactic teaching. The purpose of this study is to compare computer-based and mannequin-based approaches for training residents on MV. METHODS: This prospective randomized single-blind trial involved 50 residents. All participants attended the same didactic lecture on respiratory pathophysiology and were subsequently randomized into two groups: the mannequin group (n = 25) and the computer screen-based simulator group (n = 25). One week later, each underwent a training assessment using five different scenarios of acute respiratory failure of different etiologies. Later, both groups underwent further testing of patient management, using in situ high-fidelity simulation of a patient with acute respiratory distress syndrome. RESULTS: Baseline knowledge was not significantly different between the two groups (P = 0.72). Regarding the training assessment, no significant differences were detected between the groups. In the final assessment, the scores of only the mannequin group significantly improved between the training and final session in terms of either global rating score [3.0 (2.5-4.0) vs. 2.0 (2.0-3.0), P = 0.005] or percentage of key score (82% vs. 71%, P = 0.001). CONCLUSIONS: Mannequin-based simulation has the potential to improve skills in managing MV.


Asunto(s)
Anestesiología/educación , Simulación por Computador , Internado y Residencia/métodos , Maniquíes , Entrenamiento Simulado/métodos , Adulto , Competencia Clínica , Evaluación Educacional , Femenino , Enseñanza Mediante Simulación de Alta Fidelidad/métodos , Humanos , Conocimiento , Masculino , Estudios Prospectivos , Respiración Artificial , Método Simple Ciego
14.
Chron Respir Dis ; 12(4): 357-64, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26323278

RESUMEN

Gas exchange impairment is primarily caused by ventilation-perfusion mismatch in chronic obstructive pulmonary disease (COPD), where diffusing capacity of the lungs for carbon monoxide (DLCO) remains the clinical measure. This study investigates whether DLCO: (1) can predict respiratory impairment in COPD, that is, changes in oxygen and carbon dioxide (CO2); (2) is associated with combined risk assessment score for COPD (Global Initiative for Chronic Obstructive Lung Disease (GOLD) score); and (3) is associated with blood glucose and body mass index (BMI). Fifty patients were included retrospectively. DLCO; arterial blood gas at inspired oxygen (FiO2) = 0.21; oxygen saturation (SpO2) at FiO2 = 0.21 (SpO2 (21)) and FiO2 = 0.15 (SpO2 (15)) were registered. Difference between arterial and end-tidal CO2 (ΔCO2) was calculated. COPD severity was stratified according to GOLD score. The association between DLCO, SpO2, ΔCO2, GOLD score, blood glucose, and BMI was investigated. Multiple regression showed association between DLCO and GOLD score, BMI, and glucose level (R (2) = 0.6, p < 0.0001). Linear and multiple regression showed an association between DLCO and SpO2 (21) (R (2) = 0.3, p = 0.001 and p = 0.03, respectively) without contribution from SpO2 (15) or ΔCO2. A stronger association between DLCO and GOLD score than between DLCO and SpO2 could indicate that DLCO is more descriptive of systemic deconditioning than gas exchange in COPD patients. However, further larger studies are needed. A weaker association is seen between DLCO and SpO2 (21) without contribution from SpO2 (15) and ΔCO2. This could indicate that DLCO is more descriptive of systemic deconditioning than gas exchange in COPD patients. However, further larger studies are needed.


Asunto(s)
Dióxido de Carbono/metabolismo , Oxígeno/metabolismo , Capacidad de Difusión Pulmonar , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Intercambio Gaseoso Pulmonar/fisiología , Insuficiencia Respiratoria/fisiopatología , Anciano , Análisis de los Gases de la Sangre , Glucemia/metabolismo , Monóxido de Carbono , Estudios de Cohortes , Femenino , Volumen Espiratorio Forzado , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oximetría , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Insuficiencia Respiratoria/diagnóstico , Insuficiencia Respiratoria/metabolismo , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
15.
Respir Physiol Neurobiol ; 205: 77-83, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25448397

RESUMEN

The study aimed to investigate diaphragm respiratory drive modulation through electrical activity of the diaphragm (EADi) during progressive cycling in endurance-trained men (N=7) and to test day-to-day measurement reliability. Normalized EADi increased at exercise intensities from 40% workload (WL) to 70% and 85%WL but plateaued from 70% to 85% (p<0.05). V˙O2, V˙CO2, V˙E, increased at all exercise intensities, where Vt and BF increased from 40% to 55% WL and from 70% to 85% and RER increased at 70% and 85% (p<0.05). Bland-Altman plots of normalized EADi showed bias of 0.9% and -6.4% and limits of agreement of ±36.0% and ±30.4% for absolute measurements and relative changes from 40% WL, respectively. Within-day variability appeared constant indicating that measurements within a trial are reliable. Results suggest that diaphragm respiratory drive increases at moderate exercise intensities, but plateaus at high intensities where other respiratory muscles might contribute significantly to the breathing effort, perhaps to "protect" against diaphragm fatigue.


Asunto(s)
Diafragma/fisiología , Ejercicio Físico/fisiología , Resistencia Física/fisiología , Fenómenos Fisiológicos Respiratorios , Adulto , Ciclismo , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...