Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 416(13): 3127-3137, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38580890

RESUMEN

Monoclonal antibodies (mAbs) represent the largest class of therapeutic protein drug products. mAb glycosylation produces a heterogeneous, analytically challenging distribution of glycoforms that typically should be adequately characterized because glycosylation-based product quality attributes (PQAs) can impact product quality, immunogenicity, and efficacy. In this study, two products were compared using a panel of analytical methods. Two high-resolution mass spectrometry (HRMS) workflows were used to analyze N-glycans, while nuclear magnetic resonance (NMR) was used to generate monosaccharide fingerprints. These state-of-the-art techniques were compared to conventional analysis using hydrophilic interaction chromatography (HILIC) coupled with fluorescence detection (FLD). The advantages and disadvantages of each method are discussed along with a comparison of the identified glycan distributions. The results demonstrated agreement across all methods for major glycoforms, demonstrating how confidence in glycan characterization is increased by combining orthogonal analytical methodologies. The full panel of methods used represents a diverse toolbox that can be selected from based on the needs for a specific product or analysis.


Asunto(s)
Anticuerpos Monoclonales , Interacciones Hidrofóbicas e Hidrofílicas , Espectroscopía de Resonancia Magnética , Espectrometría de Masas , Polisacáridos , Glicosilación , Anticuerpos Monoclonales/química , Polisacáridos/análisis , Polisacáridos/química , Espectrometría de Masas/métodos , Espectroscopía de Resonancia Magnética/métodos , Cromatografía Liquida/métodos
2.
JAMA Netw Open ; 4(6): e2118253, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34181009

RESUMEN

Importance: A publication reported that N-nitrosodimethylamine (NDMA), a probable human carcinogen, was formed when ranitidine and nitrite were added to simulated gastric fluid. However, the nitrite concentrations used were greater than the range detected in acidic gastric fluid in prior clinical studies. Objective: To characterize NDMA formation following the addition of ranitidine to simulated gastric fluid using combinations of fluid volume, pH levels, and nitrite concentrations, including physiologic levels. Design, Setting, and Participants: One 150-mg ranitidine tablet was added to 50 or 250 mL of simulated gastric fluid with a range of nitrite concentrations from the upper range of physiologic (100 µmol/L) to higher concentrations (10 000 µmol/L) with a range of pH levels. NDMA amounts were assessed with a liquid chromatography-mass spectrometry method. Main Outcomes and Measures: NDMA detected in simulated gastric fluid 2 hours after adding ranitidine. Results: At a supraphysiologic nitrite concentration (ie, 10 000 µmol/L), the mean (SD) amount of NDMA detected in 50 mL simulated gastric fluid 2 hours after adding ranitidine increased from 222 (12) ng at pH 5 to 11 822 (434) ng at pH 1.2. Subsequent experiments with 50 mL of simulated gastric fluid at pH 1.2 with no added nitrite detected a mean (SD) of 22 (2) ng of NDMA, which is the background amount present in the ranitidine tablets. Similarly, at the upper range of physiologic nitrite (ie, 100 µmol/L) or at nitrite concentrations as much as 50-fold greater (1000 or 5000 µmol/L) only background mean (SD) amounts of NDMA were observed (21 [3] ng, 24 [2] ng, or 24 [3] ng, respectively). With 250 mL of simulated gastric fluid, no NDMA was detected at the upper physiologic range (100 µmol/L) or 10-fold physiologic (1000 µmol/L) nitrite concentrations, while NDMA was detected (mean [SD] level, 7353 [183] ng) at a 50-fold physiologic nitrite concentration (5000 µmol/L). Conclusions and Relevance: In this in vitro study of ranitidine tablets added to simulated gastric fluid with different nitrite concentrations, ranitidine conversion to NDMA was not detected until nitrite was 5000 µmol/L, which is 50-fold greater than the upper range of physiologic gastric nitrite concentrations at acidic pH. These findings suggest that ranitidine is not converted to NDMA in gastric fluid at physiologic conditions.


Asunto(s)
Dimetilnitrosamina/metabolismo , Absorción Gastrointestinal/fisiología , Ranitidina/análisis , Antagonistas de los Receptores H2 de la Histamina/análisis , Antagonistas de los Receptores H2 de la Histamina/sangre , Humanos , Ranitidina/sangre
3.
Front Med (Lausanne) ; 6: 142, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31316989

RESUMEN

The US Food and Drug Administration has encouraged the reintroduction of bovine heparin drug product to the US market to mitigate the risks of heparin shortages and potential adulteration or contamination of the primary source which is porcine heparin. Here, a 1D-NMR method was applied to compare heparin sodium of bovine intestinal origin with that of bovine lung, porcine, or ovine intestinal origin. The results showed that a simple 1D test using NMR signal intensity ratios among diagnostic signals of the proton spectra uniquely identified the origin of heparin and concomitantly could be used to assure the correct sample labeling. However, a limitation of the use of only mono-dimensional spectra is that these spectra may not provide sufficiently detailed information on the composition of heparin batches to adequately determine the quality of this complex product. As an alternative, a higher resolution quantitative 2D-HSQC method was used to calculate the percentage of mono- and disaccharides, distinguish the origin of heparin and, simultaneously, assess the heparin composition. The 2D-HSQC method is proposed to provide sufficient information to evaluate the quality of industrial production process used to make the drug substance. Together, the 1D and 2D data produced by these measurements can be used to assure the identity and purity of this widely used drug.

4.
Molecules ; 22(7)2017 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-28698456

RESUMEN

Because of the complexity and global nature of the heparin supply chain, the control of heparin quality during manufacturing steps is essential to ensure the safety of the final active pharmaceutical ingredient (API). For this reason, there is a need to develop consistent analytical methods able to assess the quality of heparin early in production (i.e., as the crude heparin before it is purified to API under cGMP conditions). Although a number of analytical techniques have been applied to characterize heparin APIs, few of them have been applied for crude heparin structure and composition analyses. Here, to address this issue, NMR spectroscopy and chemometrics were applied to characterize 88 crude heparin samples. The samples were also analyzed by strong anion exchange HPLC (SAX-HPLC) as an orthogonal check of the purity levels of the crudes analyzed by NMR. The HPLC data showed that the chemometric analysis of the NMR data differentiated the samples based on their purity. These orthogonal approaches differentiated samples according their glycosaminoglycan (GAG) composition and their mono and disaccharide composition and structure for each GAG family (e.g., heparin/heparan, dermatan sulfate, and chondroitin sulfate A). Moreover, quantitative HSQC and multivariate analysis (PCA) were used to distinguish between crude heparin of different animal and tissue sources.


Asunto(s)
Dermatán Sulfato/química , Glicosaminoglicanos/química , Heparina/química , Animales , Cromatografía Líquida de Alta Presión , Dermatán Sulfato/aislamiento & purificación , Contaminación de Medicamentos , Glicosaminoglicanos/aislamiento & purificación , Heparina/aislamiento & purificación , Heparina/normas , Humanos , Espectroscopía de Resonancia Magnética , Control de Calidad
5.
AAPS J ; 19(3): 765-771, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28116677

RESUMEN

In 2000, bovine heparin was withdrawn from the US market for fear of contamination with bovine spongiform encephalopathy (BSE) agent, the cause of variant Creutzfeldt-Jakob disease in humans. Thus, US heparin is currently sourced only from pig intestines. Availability of alternative sources of crude heparin, a life-saving drug, would benefit public health. Bovine heparin is an obvious option, but BSE clearance by the bovine heparin manufacturing process should be evaluated. To this end, using hamster 263K scrapie as a surrogate for BSE agent, we applied a four-step bench-scale heparin purification protocol resembling a typical heparin manufacturing process to investigate removal of the spiked scrapie agent. We removed aliquots from each step and analyzed them for residual abnormal prion protein (PrPTSE) using a sensitive in vitro method, real-time quaking-induced conversion (RT-QuIC) assay, and for infectivity using animal bioassays. The purification process reduced infectivity by 3.6 log10 and removed PrPTSE, measured as seeding activity, by 3.4 log10. NaOH treatment was the most effective removal step tested. We also investigated NaOH at different concentrations and pH: the results showed that as much as 5.2 log10 of PrPTSE seeding activity was removed at pH 12.5. Thus, changes to the concentration, treatment time, and temperature of alkaline extraction might further improve removal. Our results, using a basic heparin manufacturing process, inform efforts to reintroduce safe bovine heparin in the USA.


Asunto(s)
Encefalopatía Espongiforme Bovina/prevención & control , Heparina/aislamiento & purificación , Proteínas Priónicas/aislamiento & purificación , Animales , Bovinos , Encefalopatía Espongiforme Bovina/transmisión , Intestinos/química , Mesocricetus , Scrapie/transmisión , Hidróxido de Sodio , Extractos de Tejidos
6.
J Pharm Biomed Anal ; 136: 92-105, 2017 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-28068519

RESUMEN

An NMR HSQC method has recently been proposed for the quantitative determination of the mono- and disaccharide subunits of heparin and low molecular weight heparins (LMWH). The focus of the current study was the validation of this procedure to make the 2D-NMR method suitable for pharmaceutical quality control applications. Pre-validation work investigated the effects of several experimental parameters to assess robustness and to optimize critical factors. Important experimental parameters were pulse sequence selection, equilibration interval between pulse trains and temperature. These observations were needed so that the NMR method was sufficiently understood to enable continuous improvement. A standard validation study on heparin then examined linearity, repeatability, intermediate precision and limits of detection and quantitation; selected validation parameters were also determined for LMWH.


Asunto(s)
Disacáridos/análisis , Heparina de Bajo-Peso-Molecular/análisis , Heparina/análisis , Monosacáridos/análisis , Resonancia Magnética Nuclear Biomolecular/métodos , Límite de Detección , Estructura Molecular , Peso Molecular , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...