Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Future Cardiol ; 19(3): 155-162, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-37259838

RESUMEN

Aim: To assess the diagnostic value of left atrial deformation parameters during dobutamine stress echocardiography to predict significant coronary artery stenosis in patients with moderate pretest probability of coronary artery disease (CAD). Materials & methods: Rest and stress echocardiography were performed on 61 patients with a moderate and high probability of CAD. Based on presence of CAD patients were divided into pathological and nonpathological groups. Results: Early diastolic strain rate (LAe SR) was significantly lower among the pathological group at high dobutamine doses. LAe SR was evaluated with receiver operating characteristic curve and threshold prognostic value was set of -2.05 (sensitivity 78%, specificity 50%, area under the curve 0.638; p = 0.026). Conclusion: Measuring LAe SR has predictive value and might be a helpful parameter in assessing ischemia.


Asunto(s)
Fibrilación Atrial , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Humanos , Estenosis Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Ecocardiografía de Estrés , Atrios Cardíacos/diagnóstico por imagen , Angiografía Coronaria
2.
J Cardiovasc Thorac Res ; 14(3): 180-190, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36398054

RESUMEN

Introduction: The study aimed to evaluate the diagnostic value of global and regional myocardial deformation parameters derived from two-dimensional speckle-tracking echocardiography to detect functionally significant coronary artery stenosis. Methods: Dobutamine stress echocardiography and cardiac magnetic resonance myocardial perfusion imaging (CMR-MPI) were performed on 145 patients with a moderate and high probability of coronary artery disease (CAD) and LVEF≥55%. Significant CAD was defined as>50% stenosis of the left main stem,>70% stenosis in a major coronary vessel, or in the presence of intermediate stenosis (50-69%) validated as hemodynamically significant by CMRMPI. Patients were divided in two groups: non-pathological (48.3%) vs pathological (51.7%), according to CAG and CMR-MPI results. Afterwards, off-line speckle-tracking analysis was performed to analyse myocardial deformation parameters. Results: There were no differences in myocardial deformation parameters at rest between groups, except global longitudinal strain (GLS) and global radial strain (GRS) were significantly lower in the CAD (+) group: -21.3±2.2 vs.-16.3±2.3 (P<0.001) and 39.7±23.2 vs. 24.5±15.8 (P<0.001). GLS and regional longitudinal strain rate (SR) had the highest diagnostic value at high dobutamine dose with AUC of 0.902 and 0.878, respectively. At early recovery, GLS was also found to be the best myocardial deformation parameter with a sensitivity of 78%, specificity 67%, AUC 0.824. Conclusion: Global and regional myocardial deformation parameters are highly sensitive and specific in detecting functionally significant CAD. The combination of deformation parameters and WMA provides an incremental diagnostic value for patients with a moderate and high probability of CAD, especially the combination with regional longitudinal SR.

3.
Echocardiography ; 39(11): 1439-1445, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36266744

RESUMEN

AIMS: This study sought to examine the feasibility, accuracy and reproducibility of a novel, fully automated 2D transthoracic echocardiography (2D TTE) parasternal long axis (PLAX) view aortic measurements quantification software compared to board-certified cardiologists in controlled clinical setting. METHODS AND RESULTS: Aortic Annulus (AoA), Aortic Sinus (AoS), Sinotubular Junction (STJ) and Proximal Ascending Aorta (AAo) diameter measurements were performed retrospectively on each of 58 subjects in two different ways: twice using a fully automated software (Ligence Heart version 2) and twice manually by three cardiologists (ORG) and one expert cardiologist (EC). Out of 58 studies AoA was measured in 54 (93%), AoS in 55 (95%), STJ in 55 (95%) and AAo in 54 (93%) studies. Automated measurements had a stronger correlation with EC when compared to ORG with the largest correlation difference of .1 for STJ measurements and lowest difference of .01 for AoS measurements. Automated software was in higher agreement with ground truth intervals (ORG measurements mean +- SEM) in three out of four measurements. CONCLUSION: Fully automated 2D TTE PLAX view aortic measurements using a novel AI-based quantification software are feasible and yield results that are in close agreement with what experienced readers measure manually while providing better reproducibility. This approach may prove to have important clinical implications in the automation of the aortic root and ascending aorta assessment to improve workflow efficiency.


Asunto(s)
Inteligencia Artificial , Ecocardiografía Tridimensional , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estudios de Factibilidad , Ecocardiografía/métodos , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos
4.
J Cardiovasc Echogr ; 30(3): 131-139, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33447503

RESUMEN

BACKGROUND: The main goal of this manuscript was to evaluate the diagnostic value of the global and regional postsystolic shortening (PSS) parameters, assessed by two-dimensional (2D) speckle-tracking echocardiography, at rest and during dobutamine stress for the detection of functionally significant coronary artery stenoses in patients with moderate pretest probability of stable coronary artery disease (CAD). METHODS: Dobutamine stress echocardiography (DSE) and adenosine stress myocardial perfusion imaging by cardiac magnetic resonance (CMR-MPI) were performed on 83 patients with moderate pretest probability of stable CAD and left ventricle ejection fraction ≥55%. CAD was defined as ≥50% diameter stenoses on invasive coronary artery angiography (CAA) validated as hemodynamically significant by CMR-MPI. According to invasive CAA and CMR-MPI results, patients were divided into two groups: Nonpathologic CAD (-) group: 38 (45.8%) and pathologic CAD (+) group: 45 (54.2%). RESULTS: There were no significant differences in clinical characteristics, conventional 2D echocardiography between the two groups at rest and during low dobutamine dose. Regional postsystolic index (PSI) during recovery phase had the highest area under the receiver operating characteristic curve (AUC) (AUC 0.882, sensitivity 87%, specificity 92%) for the detection of functionally significant one-vessel disease. During high dobutamine dose, regional PSI had sensitivity 78% and specificity 81% (AUC 0.78) to detect significant CAD. Regional PSI remained the same tendency remains for the detection of multiple-vessel CAD. Other myocardial deformation parameters were less sensitive and specific during high dobutamine dose and recovery phase. CONCLUSIONS: PSS parameters showed to be sensitive and specific in detecting hemodynamically significant coronary artery stenosis in patients with stable CAD with moderate pretest probability. The study revealed that the assessment of regional PSI performed during recovery improves the diagnostic accuracy of DSE for the detection of functionally significant CAD.

5.
Anatol J Cardiol ; 22(1): 13-20, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31264652

RESUMEN

OBJECTIVE: Left ventricle (LV) geometry and dyssynchrony are associated with LV remodeling after acute myocardial infarction (AMI). The aim of this prospective study was to assess the diagnostic value of new three-dimensional echocardiography (3DE) parameters [sphericity (SI) and systolic dyssynchrony indexes (SDI)] for the prediction of LV remodeling after AMI and to compare them with two-dimensional echocardiography (2DE) parameters. METHODS: 2DE and 3DE were performed in 75 patients with AMI within 3 days from the onset of MI and 6 months later. LV remodeling was defined as a ≥15% increase in the LV end-diastolic volume (EDV) at follow-up. 3D SI was calculated by dividing EDV by the volume of a sphere whose diameter was derived from the major end-diastolic LV long axis. SDI was considered as a standard deviation of the time from cardiac cycle onset to minimum systolic volume in 16 LV segments. RESULTS: LV remodeling was identified in 34 (45%) patients using the 2DE method and in 22 (29%) patients using the 3DE method. Evaluated 3DE parameters, such as EDV [area under the receiver operating characteristic (ROC) curve (AUC) 0.742, sensitivity 71%, specificity 79%], end-systolic volume (AUC 0.729, sensitivity 69%, specificity 78%), SDI (AUC 0.777, sensitivity 73%, specificity 77%), and SI, had significant prognostic value for LV remodeling. According to the AUC, the highest predictive value had 3D SI (AUC 0.957, sensitivity 90%, specificity 91%). CONCLUSION: 3DE parameters, especially 3D SI and SDI, play important roles in the prediction of LV remodeling after AMI and can be used in clinical practice.


Asunto(s)
Ecocardiografía Tridimensional/normas , Infarto del Miocardio/diagnóstico por imagen , Disfunción Ventricular Izquierda/prevención & control , Remodelación Ventricular , Anciano , Área Bajo la Curva , Proteína C-Reactiva/análisis , Estudios de Cohortes , Femenino , Humanos , Técnicas para Inmunoenzimas , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Revascularización Miocárdica , Nefelometría y Turbidimetría , Variaciones Dependientes del Observador , Intervención Coronaria Percutánea , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Fumar , Terapia Trombolítica , Troponina I/análisis , Función Ventricular Izquierda/fisiología
6.
Echocardiography ; 33(10): 1512-1522, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27307201

RESUMEN

BACKGROUND: The aim of this prospective study was to assess the usefulness of global longitudinal strain (GLS), regional diastolic and systolic strain, strain rate (SR) parameters at rest and during dobutamine stress echocardiography for detecting significant coronary artery stenosis in patients with a moderate or high probability of coronary artery disease (CAD). METHODS: Dobutamine stress echocardiography and adenosine magnetic resonance imaging (AMRI) were performed on 127 patients with a moderate and high probability of CAD and left ventricle ejection fraction ≥55%. CAD was defined as ≥70% diameter stenosis on coronary angiography validated as hemodynamically significant by AMRI. Patients were grouped according to coronary angiography and AMRI results: CAD (-) n=67 (52.8%) vs CAD (+) n=60 (47.2%). RESULTS: There were no significant differences of clinical characteristics, conventional echocardiography, and deformation parameters between the two groups at rest except that GLS was higher in the CAD (-) group (-21.5±2.4% vs -16.2±2.1%, P=.00). GLS at high dobutamine doses had the highest area under the ROC curve (AUC) (AUC 0.955, sensitivity 94%, specificity 92%). Radial late diastolic SR at low doses performed best out of all diastolic parameters with an AUC of 0.789, sensitivity 76.7%, specificity 91.7%. Other deformation parameters including visual assessment were inferior. CONCLUSIONS: Global longitudinal strain is highly sensitive and specific in detecting hemodynamically significant coronary artery stenosis in moderate- to high-risk patients without known CAD. This is the first study showing that GLS is more sensitive and specific compared with early and late diastolic SR parameters or visual assessment in detecting CAD.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/epidemiología , Dobutamina , Ecocardiografía de Estrés/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Volumen Sistólico , Adulto , Módulo de Elasticidad , Femenino , Humanos , Lituania/epidemiología , Masculino , Prevalencia , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Sensibilidad y Especificidad , Vasodilatadores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...