Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med Biol ; 68(19)2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37747082

RESUMEN

Objective.A new method to estimate the range of an ion beam in a patient during heavy-ion therapy was investigated, which was previously verified for application in proton therapy.Approach.The method consists of placing a hadron tumour marker (HTM) close to the tumour. As the treatment beam impinges on the HTM, the marker undergoes nuclear reactions. When the HTM material is carefully chosen, the activation results in the emission of several delayed, characteristicγrays, whose intensities are correlated with the remaining range inside the patient. When not just one but two reaction channels are investigated, the ratio between these twoγray emissions can be measured, and the ratio is independent of any beam delivery uncertainties.Main results.A proof-of-principle experiment with an16O ion beam and Ag foils as HTM was successfully executed. The107Ag(16O,x)112Sb and the107Ag(16O,x)114Sb reaction channels were identified as suitable for the HTM technique. When only oneγ-ray emission is measured, the resulting range-uncertainty estimation is at the 0.5 mm scale. When both channels are considered, a theoretical limit on the range uncertainty of a clinical fiducal marker was found to be ±290µm.Significance.Range uncertainty of a heavy-ion beam limits the prescribed treatment plan for cancer patients, especially the direction of the ion beam in relation to any organ at risk. An easy to implement range-verification technique which can be utilized during clinical treatment would allow treatment plans to take full advantage of the sharp fall-off of the Bragg peak without the risk of depositing excessive dose into healthy tissue.


Asunto(s)
Radioterapia de Iones Pesados , Terapia de Protones , Humanos , Biomarcadores de Tumor , Radioterapia de Iones Pesados/métodos , Terapia de Protones/métodos , Incertidumbre , Método de Montecarlo
2.
Phys Med Biol ; 68(18)2023 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-37681308

RESUMEN

Objective.The results of a follow-up experiment investigating a novel method for sub-milimetre range verification (RV) in proton therapy (PT) are presented.Approach.The method consists of implanting a hadron tumour marker (HTM) near the planned treatment volume, and measuring theγ-ray signals emitted as a result of activation by the proton beam. These signals are highly correlated with the energy of the beam impinging on the HTM and can provide an absolute measurement of the range of the beam relative to the position of the HTM, which is independent of any uncertainties in beam delivery.Main results.Three candidate HTM materials were identified and combined into a single composite HTM, which makes use of the strongest reaction in each material. The setup of the previous experiment was improved on by using high-purity germanium detectors to measure theγ-ray signal with a higher resolution than was previously achieved. A PMMA phantom was also used to simulate theγ-ray background from tissue activation. HTM RV using the data collected in this study yielded range measurements whose average deviation from the expected value was 0.13(22)mm.Significance.Range uncertainty in PT limits the prescribed treatment plan for cancer patients with large safety margins and constrains the direction of the proton beam in relation to any organ at risk. The sub-milimetre range uncertainty achieved in this study using HTM RV, if implemented clinically, would allow for a reduction in the size of safety margins, increasing the therapeutic window for PT.


Asunto(s)
Germanio , Terapia de Protones , Humanos , Protones , Biomarcadores de Tumor , Fantasmas de Imagen
3.
Phys Rev Lett ; 127(11): 112701, 2021 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-34558922

RESUMEN

We have performed the first direct measurement of the ^{83}Rb(p,γ) radiative capture reaction cross section in inverse kinematics using a radioactive beam of ^{83}Rb at incident energies of 2.4 and 2.7A MeV. The measured cross section at an effective relative kinetic energy of E_{cm}=2.393 MeV, which lies within the relevant energy window for core collapse supernovae, is smaller than the prediction of statistical model calculations. This leads to the abundance of ^{84}Sr produced in the astrophysical p process being higher than previously calculated. Moreover, the discrepancy of the present data with theoretical predictions indicates that further experimental investigation of p-process reactions involving unstable projectiles is clearly warranted.

4.
Phys Med Biol ; 66(2): 025005, 2021 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-32998122

RESUMEN

In this work, a new method of range verification for proton therapy (PT) is experimentally demonstrated for the first time. If a metal marker is implanted near the tumour site, its response to proton activation will result in the emission of characteristic γ rays. The relative intensity of γ rays originating from competing fusion-evaporation reaction channels provides a unique signature of the average proton energy at the marker, and by extension the beam's range, in vivo and in real time. The clinical feasibility of this method was investigated at the PT facility at TRIUMF with a proof-of-principle experiment which irradiated a naturally-abundant molybdenum foil at various proton beam energies. Delayed characteristic γ rays were measured with two Compton-shielded LaBr3 scintillators. The technique was successfully demonstrated by relating the relative intensity of two γ-ray peaks to the energy of the beam at the Mo target, opening the door to future clinical applications where the range of the beam can be verified in real time.


Asunto(s)
Rayos gamma/uso terapéutico , Molibdeno , Terapia de Protones/métodos , Análisis Espectral , Humanos , Método de Montecarlo
5.
Phys Med Biol ; 65(24): 245047, 2020 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-33331299

RESUMEN

In this work, we propose a novel technique for in-vivo proton therapy range verification. This technique makes use of a molybdenum hadron tumour marker, implanted at a short distance from the clinical treatment volume. Signals emitted from the marker during treatment can provide a direct measurement of the proton beam energy at the marker's position. Fusion-evaporation reactions between the proton beam and marker nucleus result in the emission of delayed characteristic γ rays, which are detected off-beam for an improved signal-to-noise ratio. In order to determine the viability of this technique and to establish an experimental setup for future work, the Monte Carlo package GEANT4 was used in combination with ROOT to simulate a treatment scenario with the new method outlined in this work. These simulations show that the intensity of delayed γ rays produced from competing reactions yields a precise measurement of the range of the proton beam relative to the marker, with sub-millimetre uncertainty.


Asunto(s)
Rayos gamma , Método de Montecarlo , Terapia de Protones/métodos , Simulación por Computador , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...