Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Sci Rep ; 10(1): 3141, 2020 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-32081989

RESUMEN

External cephalic version (ECV) is associated with a moderate degree of pain. Virtual reality (VR) is a technology that has shown promise in offering procedural analgesia. We undertook a clinical pilot to assess the viability of VR to reduce pain during ECV. In an open randomised controlled trial (RCT), we randomised 50 women to either VR or standard care each (25 per group). Women receiving VR were administered VR content (Skylights) via a headset. Pre- and post-procedural measures of pain, anxiety, device experience and vital signs were measured. There were no significant differences between groups (VR/no VR) in pain scores (60.68 vs 49.76; p = 0.2), ECV success rates (80% vs 76%; p = 0.7) or anxiety levels. The women receiving VR had a significantly higher anticipation of pain pre-procedurally (70.0 vs 50.0; p = 0.03). 20 (80%) of the VR women indicated that they would use VR again and 22 (88%) indicated they would recommend it to a friend having ECV. There were no significant differences between groups for side effects encountered or changes in vital signs. We have shown that using VR during ECV is feasible and appears safe. Our results inform the design of future RCTs.


Asunto(s)
Analgesia/métodos , Manejo del Dolor/métodos , Versión Fetal/métodos , Realidad Virtual , Adulto , Ansiedad , Simulación por Computador , Estudios de Factibilidad , Femenino , Humanos , Dolor , Dimensión del Dolor/métodos , Proyectos Piloto , Embarazo , Versión Fetal/efectos adversos
3.
Cardiovasc J Afr ; 28(4): 229-234, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28906538

RESUMEN

OBJECTIVE: While nuclear myocardial perfusion imaging (MPI) offers many benefits to patients with known or suspected cardiovascular disease, concerns exist regarding radiation-associated health effects. Little is known regarding MPI practice in Africa. We sought to characterise radiation doses and the use of MPI best practices that could minimise radiation in African nuclear cardiology laboratories, and compare these to practice worldwide. METHODS: Demographics and clinical characteristics were collected for a consecutive sample of 348 patients from 12 laboratories in six African countries over a one-week period from March to April 2013. Radiation effective dose (ED) was estimated for each patient. A quality index (QI) enumerating adherence to eight best practices, identified a priori by an IAEA expert panel, was calculated for each laboratory. We compared these metrics with those from 7 563 patients from 296 laboratories outside Africa. RESULTS: Median (interquartile range) patient ED in Africa was similar to that of the rest of the world [9.1 (5.1-15.6) vs 10.3 mSv (6.8-12.6), p = 0.14], although a larger proportion of African patients received a low ED, ≤ 9 mSv targeted in societal recommendations (49.7 vs 38.2%, p < 0.001). Bestpractice adherence was higher among African laboratories (QI score: 6.3 ± 1.2 vs 5.4 ± 1.3, p = 0.013). However, median ED varied significantly among African laboratories (range: 2.0-16.3 mSv; p < 0.0001) and QI range was 4-8. CONCLUSION: Patient radiation dose from MPI in Africa was similar to that in the rest of the world, and adherence to best practices was relatively high in African laboratories. Nevertheless there remain opportunities to further reduce radiation exposure to African patients from MPI.


Asunto(s)
Cardiología/estadística & datos numéricos , Cardiopatías/diagnóstico , Imagen de Perfusión Miocárdica/efectos adversos , Exposición a la Radiación/efectos adversos , Traumatismos por Radiación/epidemiología , Sistema de Registros , Tomografía Computarizada de Emisión de Fotón Único/efectos adversos , África/epidemiología , Anciano , Estudios Transversales , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad
5.
Circ J ; 81(4): 501-510, 2017 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-28179594

RESUMEN

BACKGROUND: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia.Methods and Results:Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. CONCLUSIONS: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.


Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Pautas de la Práctica en Medicina/normas , Exposición a la Radiación/estadística & datos numéricos , Anciano , Asia , Cardiología/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medicina Nuclear/métodos , Calidad de la Atención de Salud , Dosis de Radiación , Tecnecio/administración & dosificación , Talio/administración & dosificación
6.
J Nucl Cardiol ; 24(3): 851-859, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-26902484

RESUMEN

BACKGROUND: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. METHODS AND RESULTS: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight "best practices" were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus. CONCLUSIONS: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the "as low as reasonably achievable" (ALARA) principle.


Asunto(s)
Cardiología/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Exposición a la Radiación/prevención & control , Protección Radiológica/estadística & datos numéricos , Tomografía Computarizada de Emisión/estadística & datos numéricos , Cardiología/estadística & datos numéricos , Adhesión a Directriz/normas , Adhesión a Directriz/estadística & datos numéricos , Encuestas de Atención de la Salud , Humanos , Internacionalidad , América Latina/epidemiología , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Pautas de la Práctica en Medicina/normas , Mejoramiento de la Calidad , Protección Radiológica/normas , Tomografía Computarizada de Emisión/normas , Revisión de Utilización de Recursos
7.
Heart Lung Circ ; 26(1): 25-34, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27425184

RESUMEN

BACKGROUND: There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. METHODS: Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. RESULTS: In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). CONCLUSION: Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world.


Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Dosis de Radiación , Exposición a la Radiación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oceanía
8.
J Nucl Cardiol ; 24(2): 507-517, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27796852

RESUMEN

OBJECTIVE: To test the hypothesis that, in the initial evaluation of patients with suspected coronary artery disease (CAD), stress myocardial perfusion imaging (MPI) would result in less downstream testing than coronary computed tomographic angiography (CCTA). METHODS: In this international, randomized trial, mildly symptomatic patients with an intermediate likelihood of having CAD, and asymptomatic patients at intermediate risk of cardiac events, underwent either initial stress-rest MPI or CCTA. The primary outcome was downstream noninvasive or invasive testing at 6 months. Secondary outcomes included cumulative effective radiation dose (ERD) and costs at 12 months. RESULTS: We recruited 303 patients (151 MPI and 152 CTA) from 6 centers in 6 countries. The initial MPI was abnormal in 29% (41/143) and CCTA in 56% (79/141) of patients. Fewer patients undergoing initial stress-rest MPI had further downstream testing at 6 months (adjusted OR 0.51, 95% CI 0.28-0.91, P = 0.023). There was a small increase in the median cumulative ERD with MPI (9.6 vs. 8.8 mSv, P = 0.04), but no difference in costs between the two strategies at 12 months. CONCLUSION: In the management of patients with suspected CAD, a strategy of initial stress MPI is substantially less likely to require further downstream testing than initial testing with CCTA. TRIAL REGISTRATION: clinicaltrials.gov identification number NCT01368770.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Pruebas de Función Cardíaca/métodos , Tamizaje Masivo/métodos , Imagen de Perfusión Miocárdica/métodos , Diagnóstico Precoz , Femenino , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
JACC Cardiovasc Imaging ; 9(4): 376-84, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27056156

RESUMEN

OBJECTIVES: The aim of this study was to investigate gender-based differences in nuclear cardiology practice globally, with a particular focus on laboratory volume, radiation dose, protocols, and best practices. BACKGROUND: It is unclear whether gender-based differences exist in radiation exposure for nuclear cardiology procedures. METHODS: In a large, multicenter, observational, cross-sectional study encompassing 7,911 patients in 65 countries, radiation effective dose was estimated for each examination. Patient-level best practices relating to radiation exposure were compared between genders. Analysis of covariance was used to determine any difference in radiation exposure according to gender, region, and the interaction between gender and region. Linear, logistic, and hierarchical regression models were developed to evaluate gender-based differences in radiation exposure and laboratory adherence to best practices. The study also included the United Nations Gender Inequality Index and Human Development Index as covariates in multivariable models. RESULTS: The proportion of myocardial perfusion imaging studies performed in women varied among countries; however, there was no significant correlation with the Gender Inequality Index. Globally, mean effective dose for nuclear cardiology procedures was only slightly lower in women (9.6 ± 4.5 mSv) than in men (10.3 ± 4.5 mSv; p < 0.001), with a difference of only 0.3 mSv in a multivariable model adjusting for patients' age and weight. Stress-only imaging was performed more frequently in women (12.5% vs. 8.4%; p < 0.001); however, camera-based dose reduction strategies were used less frequently in women (58.6% vs. 65.5%; p < 0.001). CONCLUSIONS: Despite significant worldwide variation in best practice use and radiation doses from nuclear cardiology procedures, only small differences were observed between genders worldwide. Regional variations noted in myocardial perfusion imaging use and radiation dose offer potential opportunities to address gender-related differences in delivery of nuclear cardiology care.


Asunto(s)
Disparidades en Atención de Salud , Cardiopatías/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones , Dosis de Radiación , Exposición a la Radiación , Radiofármacos/administración & dosificación , Tomografía Computarizada de Emisión de Fotón Único , África , Anciano , Asia , Distribución de Chi-Cuadrado , Circulación Coronaria , Estudios Transversales , Europa (Continente) , Femenino , Cardiopatías/fisiopatología , Humanos , América Latina , Modelos Lineales , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Imagen de Perfusión Miocárdica/efectos adversos , América del Norte , Oceanía , Oportunidad Relativa , Tomografía de Emisión de Positrones/efectos adversos , Radiofármacos/efectos adversos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Tomografía Computarizada de Emisión de Fotón Único/efectos adversos
10.
Eur J Nucl Med Mol Imaging ; 43(4): 718-28, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26686336

RESUMEN

PURPOSE: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. METHODS: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). RESULTS: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. CONCLUSION: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Tomografía de Emisión de Positrones/métodos , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Técnicas de Imagen Cardíaca/efectos adversos , Técnicas de Imagen Cardíaca/instrumentación , Técnicas de Imagen Cardíaca/normas , Cardiología/organización & administración , Unión Europea , Medicina Nuclear/organización & administración , Tomografía de Emisión de Positrones/efectos adversos , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/normas , Sociedades Científicas
11.
Eur Heart J ; 36(26): 1689-96, 2015 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-25898845

RESUMEN

AIMS: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. METHODS AND RESULTS: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. CONCLUSION: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.


Asunto(s)
Adhesión a Directriz/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Guías de Práctica Clínica como Asunto/normas , Dosis de Radiación , Exposición a la Radiación/análisis , Anciano , Cardiología/normas , Protocolos Clínicos/normas , Estudios Transversales , Femenino , Salud Global , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Tomografía de Emisión de Positrones/normas , Tomografía de Emisión de Positrones/estadística & datos numéricos , Práctica Profesional/normas , Práctica Profesional/estadística & datos numéricos , Calidad de la Atención de Salud/normas , Calidad de la Atención de Salud/estadística & datos numéricos , Análisis de Regresión , Tomografía Computarizada de Emisión de Fotón Único/normas , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos
12.
Indian J Exp Biol ; 52(8): 793-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25141542

RESUMEN

With an aim to devise a prophylactic and/or therapeutic approach for preventing internalization of radiothallium (201Tl), and more importantly by implication, its chemical analogue radiocesium (137Cs) during any nuclear emergency, different ex vivo and in vivo animal models were created to determine the role ofpH in absorption of 201Tl across jejunum/muscle tissue and whole body retention of 201Tl respectively. Movement of Tl+ under simulated pH conditions proved that pH had direct influence on its absorption. Oral intake of acidified water or parenteral administration of lactic acid was able to reduce the body burden of 201Tl by up to 12 and 50% respectively. The results indicate that acidification of gut, within physiological range may be used as an option for decorporation/inhibition of incorporation of radiothallium and radiocesium, particularly in cases of mass casualty.


Asunto(s)
Yeyuno/efectos de los fármacos , Ácido Láctico/administración & dosificación , Músculo Esquelético/efectos de los fármacos , Protectores contra Radiación/administración & dosificación , Animales , Radioisótopos de Cesio/efectos adversos , Humanos , Yeyuno/efectos de la radiación , Ratones , Músculo Esquelético/efectos de la radiación , Ratas , Radioisótopos de Talio/efectos adversos , Irradiación Corporal Total/efectos adversos
13.
Semin Nucl Med ; 43(3): 161-6, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23561452

RESUMEN

The International Atomic Energy Agency's (IAEA) programme in human health aims to enhance the capabilities in Member States to address needs related to the prevention, diagnosis, and treatment of diseases through the application of nuclear techniques. It has the specific mission of fostering the application of nuclear medicine techniques as part of the clinical management of certain types of diseases. Attuned to the continuous evolution of this specialty as well as to the advancement and diversity of methods in delivering capacity building efforts in this digital age, the section of nuclear medicine of the IAEA has enhanced its program by incorporating online educational resources for nuclear medicine professionals into its repertoire of projects to further its commitment in addressing the needs of its Member States in the field of nuclear medicine. Through online educational resources such as the Human Health Campus website, e-learning modules, and scheduled interactive webinars, a validation of the commitment by the IAEA in addressing the needs of its Member States in the field of nuclear medicine is strengthened while utilizing the advanced internet and communications technology which is progressively becoming available worldwide. The Human Health Campus (www.humanhealth.iaea.org) is the online educational resources initiative of the Division of Human Health of the IAEA geared toward enhancing professional knowledge of health professionals in radiation medicine (nuclear medicine and diagnostic imaging, radiation oncology, and medical radiation physics), and nutrition. E-learning modules provide an interactive learning environment to its users while providing immediate feedback for each task accomplished. Webinars, unlike webcasts, offer the opportunity of enhanced interaction with the learners facilitated through slide shows where the presenter guides and engages the audience using video and live streaming. This paper explores the IAEA's available online educational resources programs geared toward the enhancement of the nuclear medicine profession as delivered by the section of nuclear medicine of the IAEA.


Asunto(s)
Educación Médica/métodos , Agencias Internacionales , Internet , Energía Nuclear , Medicina Nuclear/educación , Humanos , Radiofármacos
14.
Semin Nucl Med ; 43(3): 167-71, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23561453

RESUMEN

The International Atomic Energy Agency promotes the practice of nuclear medicine among its Member States with a focus on quality and safety. It considers quality culture as a part of the educational process and as a tool to reduce heterogeneity in the practice of nuclear medicine, and in turn, patient care. Sensitization about quality is incorporated in all its delivery mechanisms. The Agency has developed a structured peer-review process called quality management (QM) audits in nuclear medicine practices to help nuclear medicine facilities improve their quality through this voluntary comprehensive audit process. The process is multidisciplinary, covering all aspects of nuclear medicine practice with a focus on the patient. It complements other QM and accreditation approaches developed by professional societies or accreditation agencies. The Agency is committed to propagate its utility and assist in the implementation process. Similar auditing programs for practice in diagnostic radiology and radiotherapy, called QUADRIL and QUATRO, respectively, are also in place. Necessary amendments in the auditing process and content are incorporated based on technological and practice changes with time. The reader will become familiar with the approach of the Agency on QM in nuclear medicine and its implementation process to improve patient care.


Asunto(s)
Agencias Internacionales , Energía Nuclear , Medicina Nuclear/normas , Atención al Paciente/normas , Objetivos , Humanos , Auditoría Administrativa , Control de Calidad , Informe de Investigación
15.
Semin Nucl Med ; 43(3): 208-23, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23561459

RESUMEN

The growth in nuclear medicine, in the past decade, is largely due to hybrid imaging, specifically single-photon emission tomography-computed tomography (SPECT-CT) and positron emission tomography-computed tomography (PET-CT). Introduction and use of hybrid imaging has been growing at a fast pace. This has led to many challenges and opportunities to the personnel dealing with it. The International Atomic Energy Agency (IAEA) keeps a close watch on the trends in applications of nuclear techniques in health by many ways, including obtaining inputs from member states and professional societies. In 2012, a Technical Meeting on trends in hybrid imaging was organized by IAEA to understand the current status and trends of hybrid imaging using nuclear techniques, its role in clinical practice, and associated educational needs and challenges. Perspective of scientific societies and professionals from all the regions of the world was obtained. Heterogeneity in value, educational needs, and access was noted and the drivers of this heterogeneity were discussed. This article presents the key points shared during the technical meeting, focusing primarily on SPECT-CT and PET-CT, and shares the action plan for IAEA to deal with heterogeneity as suggested by the participants.


Asunto(s)
Países en Desarrollo , Diagnóstico por Imagen/estadística & datos numéricos , Agencias Internacionales , Internacionalidad , Energía Nuclear , Informe de Investigación , Diagnóstico por Imagen/economía , Diagnóstico por Imagen/tendencias , Ambiente , Humanos , Legislación como Asunto
16.
Int Orthop ; 36(2): 271-6, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21735206

RESUMEN

PURPOSE: The World Health Organisation has declared tuberculosis (TB) a global emergency and spinal tuberculosis is one of the most common forms. There is still controversy regarding optimum duration of treatment in osteoarticular tuberculosis due to the lack of well-defined criteria for the end point of treatment. Emergence of multi drug resistant tuberculosis, primarily due to use of poor drug regimens, further illustrates the need of newer and more effective diagnostic methods, particularly in developing countries. METHODS: This prospective clinical study to evaluate the role of technetium ((99m)Tc)-ciprofloxacin scan as a tool to assess disease activity involved in 15 cases of TB spine with a mean age of 32.2 years (range 21-72). Following a clinico-radiological diagnosis, all patients were treated with standard anti tubercular treatment and a scan was done at zero, three and six months of treatment with tracer activity being recorded and compared in sequential scans along with a parallel evaluation of clinical and radiological profile at regular intervals. RESULTS: Out of 15 cases, nine had an initially positive bone scan. Two patients (22%) converted to negative scans at three months, whereas the remaining seven (78%) turned negative at six months. The end of six months treatment was also accompanied by clinico-radiological resolution in all cases. CONCLUSION: In conclusion, technetium ((99m)Tc)-ciprofloxacin scan could be a promising tool for monitoring disease activity in selected cases of tuberculosis spine as an alternative for therapeutic drug monitoring; however, due to the small sample size, studies with a large number of patients might be of help in defining these cases in a better way.


Asunto(s)
Ciprofloxacina/análogos & derivados , Compuestos de Organotecnecio , Tiocarbamatos , Tuberculosis de la Columna Vertebral/diagnóstico por imagen , Adulto , Anciano , Comorbilidad , Diabetes Mellitus/epidemiología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Cintigrafía , Tuberculosis de la Columna Vertebral/diagnóstico , Tuberculosis de la Columna Vertebral/epidemiología
17.
J Nucl Med ; 52 Suppl 2: 16S-23S, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22144549

RESUMEN

This article describes trends in nuclear medicine in the developing world as noted by nuclear medicine professionals at the International Atomic Energy Agency (IAEA). The trends identified are based on data gathered from several sources, including information gathered through a database maintained by the IAEA; evaluation of country program frameworks of various IAEA Member States; personal interactions with representatives in the nuclear medicine field from different regions of the world; official proceedings and meeting reports of the IAEA; participation in numerous national, regional, and international conferences; discussions with the leadership of major professional societies; and relevant literature. The information presented in this article relied on both objective and subjective observations. The aims of this article were to reflect on recent developments in the specialty of nuclear medicine and to envision the directions in which it is progressing. These issues are examined in terms of dimensions of practice, growth, and educational and training needs in the field of nuclear medicine. This article will enable readers to gain perspective on the status of nuclear medicine practice, with a specific focus on the developing world, and to examine needs and trends arising from the observations.


Asunto(s)
Países en Desarrollo/estadística & datos numéricos , Medicina Nuclear/tendencias , Bases de Datos Factuales , Humanos , Agencias Internacionales , Medicina Nuclear/educación , Medicina Nuclear/estadística & datos numéricos
18.
Int Orthop ; 35(12): 1869-74, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21116818

RESUMEN

In the evidence-based medicine era, objective treatment guidelines have been laid down for pulmonary tuberculosis, but the same is not true for osteoarticular tuberculosis. This has led to demands for standardising the treatment protocol and to a lack of consensus between doctors regarding the composition and duration of treatment. Twenty-five patients with extraspinal osteoarticular tuberculosis were evaluated prospectively. Following the diagnosis, patients were given standard directly observed treatment short course (DOTS) regimen and were monitored for disease activity at zero, three and six months with the help of technetium-99m-labelled ciprofloxacin ((99m)Tc) scan. Tracer activity at the site was recorded and compared on sequential scans. Clinical and radiological profile of all the patients were also recorded at regular intervals and compared. All 25 cases had a positive (99m)Tc bone scan initially. Four patients (16%) converted to negative scans at three months, whereas the remaining 21 patients (84%) showed negative scans at six months. The end of six months therapy also coincided with resolution of clinical and radiological parameters in all cases. In conclusion, (99m)Tc scan is a promising tool for monitoring drug response in osteoarticular tuberculosis; however, due to the small sample size, studies with a large number of patients might be of help.


Asunto(s)
Antituberculosos/uso terapéutico , Ciprofloxacina/análogos & derivados , Monitoreo de Drogas/métodos , Compuestos de Organotecnecio , Radiofármacos , Tuberculosis Osteoarticular/diagnóstico por imagen , Tuberculosis Osteoarticular/tratamiento farmacológico , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Cintigrafía , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
19.
Environ Toxicol Pharmacol ; 27(2): 206-11, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21783941

RESUMEN

INTRODUCTION: The increased use of organophosphate (OP) insecticides and the ever increasing possibility of terror groups using nerve agents underscore the need to develop effective and safe antidotes against OP poisoning. While intramuscular administration of nerve gas antidotes like atropine sulphate has certain lacunae, intravenous route is neither practical nor feasible in the field conditions for mass casualties. The objective was to develop a novel atropine sulphate nasal drop formulation, evaluate and characterize it using scintigraphy and to carry out safety-efficacy study in human volunteers with a view to obtain early pharmacological effects in comparison to the existing options, particularly the conventional intramuscular route. METHODS: Permeability studies were done using atropine sulphate solution containing variable amount of chitosan. Radiometric method was developed for scintigraphy studies while standard spectroscopy was used for the quantification of atropine sulphate in fluids. Concentration of atropine sulphate in nasal drops to produce therapeutic concentration in blood was calculated. Six volunteers (age range 18-53 years) were administered the formulation delivering 6mg of atropine sulphate each. Bioavailability and atropinization were noted serially. RESULTS: Based on the results of in vitro, human scintigraphy and analytical data, 1% atropine sulphate-0.5% chitosan was chosen as the final nasal formulation. Human bioavailability curve was created which showed that the therapeutic concentration of the drug in blood was reached within 5min with nasal drops suggesting that drug delivery through the nasal route is significantly better than the intramuscular route. Unpaired t-test between the means of baseline value of heart rate and that of each time interval showed that increase in heart rate of all the volunteers became significant at 15min (P<0.01) and extremely significant at 30min (P<0.001). Correlation was evident from 5min (c>0.7). Pupil diameter showed maximal increase at 30min (P<0.01). CONCLUSIONS: This novel product, 1% atropine sulphate-0.5% chitosan nasal drops might be a safe and efficacious emergency treatment of organophosphorous poisoning with several advantages over the present management, including early atropinization and capability of mass treatment in least amount of time.

20.
Nucl Med Commun ; 28(11): 847-51, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17901767

RESUMEN

OBJECTIVES: A study was undertaken to evaluate the diagnostic efficiency of Tc-Tetrofosmin scan and color Doppler in the characterization of benign and malignant solitary thyroid nodules. METHODS: Fifty-two patients found to have a cold solitary thyroid nodule on Tc-pertechnetate scintigraphy were included in this study. All patients underwent a single-injection dual-phase (30 min and 120 min) Tc-Tetrofosmin scan. The intranodular vascularity was measured using color Doppler sonography. Fine-needle aspiration cytology was performed on all the patients. In the following days and weeks all patients underwent surgery. RESULTS: Thirteen out of 15 patients with thyroid cancer showed delayed retention of radiotracer (on 120 min images as compared to the initial 30 min image). Thirty-six out of 37 patients harboring benign solitary nodules showed significant washout of tracer on delayed images. Sensitivity, specificity, positive predictive value and negative predictive value of delayed Tc-Tetrofosmin scintigraphy were found to be 86.6, 97.2, 92.8 and 94.7%, respectively. The Doppler study was able to demonstrate increased vascularity in the center of 8 of the 15 malignant nodules. Thirty-two patients harboring a benign solitary nodule showed normal or increased peripheral vascularity on Doppler study. Sensitivity, specificity, positive predictive value and negative predictive value of color Doppler were found to be 53.5, 86.4, 61.5 and 82%, respectively. CONCLUSION: Delayed Tc-Tetrofosmin scintigraphy is a highly sensitive and specific method for characterizing solitary thyroid nodules, while color Doppler has a low sensitivity but relatively high specificity in differentiating benign from malignant thyroid lesions.


Asunto(s)
Compuestos Organofosforados , Compuestos de Organotecnecio , Radiofármacos , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Ultrasonografía Doppler en Color , Adolescente , Adulto , Anciano , Biopsia con Aguja Fina , Niño , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neovascularización Patológica/diagnóstico por imagen , Cintigrafía , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA