Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 9(8)2020 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-32707779

RESUMEN

In this clinical validation study, we developed and validated a urinary Q-Score generated from the quantitative test QSant, formerly known as QiSant, for the detection of biopsy-confirmed acute rejection in kidney transplants. Using a cohort of 223 distinct urine samples collected from three independent sites and from both adult and pediatric renal transplant patients, we examined the diagnostic utility of the urinary Q-Score for detection of acute rejection in renal allografts. Statistical models based upon the measurements of the six QSant biomarkers (cell-free DNA, methylated-cell-free DNA, clusterin, CXCL10, creatinine, and total protein) generated a renal transplant Q-Score that reliably differentiated stable allografts from acute rejections in both adult and pediatric renal transplant patients. The composite Q-Score was able to detect both T cell-mediated rejection and antibody-mediated rejection patients and differentiate them from stable non-rejecting patients with a receiver-operator characteristic curve area under the curve of 99.8% and an accuracy of 98.2%. Q-Scores < 32 indicated the absence of active rejection and Q-Scores ≥ 32 indicated an increased risk of active rejection. At the Q-Score cutoff of 32, the overall sensitivity was 95.8% and specificity was 99.3%. At a prevalence of 25%, positive and negative predictive values for active rejection were 98.0% and 98.6%, respectively. The Q-Score also detected subclinical rejection in patients without an elevated serum creatinine level but identified by a protocol biopsy. This study confirms that QSant is an accurate and quantitative measurement suitable for routine monitoring of renal allograft status.

2.
J Clin Microbiol ; 58(2)2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31776192

RESUMEN

The Singulex Clarity C. diff toxins A/B (Clarity) assay is an automated, ultrasensitive immunoassay for the detection of Clostridioides difficile toxins in stool. In this study, the performance of the Clarity assay was compared to that of a multistep algorithm using an enzyme immunoassay (EIA) for detection of glutamate dehydrogenase (GDH) and toxins A and B arbitrated by a semiquantitative cell cytotoxicity neutralization assay (CCNA). The performance of the assay was evaluated using 211 residual deidentified stool samples tested with a GDH-and-toxin EIA (C. Diff Quik Chek Complete; Techlab), with GDH-and-toxin discordant samples tested with CCNA. The stool samples were stored at -80°C before being tested with the Clarity assay. For samples discordant between Clarity and the standard-of-care algorithm, the samples were tested with PCR (Xpert C. difficile; Cepheid), and chart review was performed. The testing algorithm resulted in 34 GDH+/toxin+, 53 GDH-/toxin-, and 124 GDH+/toxin- samples, of which 39 were CCNA+ and 85 were CCNA- Clarity had 96.2% negative agreement with GDH-/toxin- samples, 100% positive agreement with GDH+/toxin+ samples, and 95.3% agreement with GDH+/toxin-/CCNA- samples. The Clarity result was invalid for one sample. Clarity agreed with 61.5% of GDH+/toxin-/CCNA+ samples, 90.0% of GDH+/toxin-/CCNA+ (high-positive) samples, and 31.6% of GDH+/toxin-/CCNA+ (low-positive) samples. The Singulex Clarity C. diff toxins A/B assay demonstrated high agreement with a testing algorithm utilizing a GDH-and-toxin EIA and CCNA. This novel automated assay may offer an accurate, stand-alone solution for C. difficile infection (CDI) diagnostics, and further prospective clinical studies are merited.


Asunto(s)
Proteínas Bacterianas/análisis , Toxinas Bacterianas/análisis , Clostridioides difficile/química , Clostridioides difficile/enzimología , Enterotoxinas/análisis , Glutamato Deshidrogenasa/análisis , Técnicas para Inmunoenzimas/normas , Adulto , Algoritmos , Automatización de Laboratorios , Infecciones por Clostridium/diagnóstico , Heces/química , Femenino , Humanos , Masculino , Sensibilidad y Especificidad
3.
J Clin Microbiol ; 57(11)2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31434726

RESUMEN

Clostridioides difficile infection (CDI) is one of the most common health care-associated infections, resulting in significant morbidity, mortality, and economic burden. Diagnosis of CDI relies on the assessment of clinical presentation and laboratory tests. We evaluated the clinical performance of ultrasensitive single-molecule counting technology for detection of C. difficile toxins A and B. Stool specimens from 298 patients with suspected CDI were tested with the nucleic acid amplification test (NAAT; BD MAX Cdiff assay or Xpert C. difficile assay) and Singulex Clarity C. diff toxins A/B assay. Specimens with discordant results were tested with the cell cytotoxicity neutralization assay (CCNA), and the results were correlated with disease severity and outcome. There were 64 NAAT-positive and 234 NAAT-negative samples. Of the 32 NAAT+/Clarity- and 4 NAAT-/Clarity+ samples, there were 26 CCNA- and 4 CCNA- samples, respectively. CDI relapse was more common in NAAT+/toxin+ patients than in NAAT+/toxin- and NAAT-/toxin- patients. The clinical specificity of Clarity and NAAT was 97.4% and 89.0%, respectively, and overdiagnosis was more than three times more common in NAAT+/toxin- than in NAAT+/toxin+ patients. The Clarity assay was superior to NAATs for the diagnosis of CDI, by reducing overdiagnosis and thereby increasing clinical specificity, and the presence of toxins was associated with negative patient outcomes.


Asunto(s)
Infecciones por Clostridium/diagnóstico , Enterotoxinas/aislamiento & purificación , Inmunoensayo/métodos , Imagen Individual de Molécula/métodos , Adulto , Anciano , Técnicas Bacteriológicas/métodos , Clostridioides difficile/química , Clostridioides difficile/genética , Infecciones por Clostridium/microbiología , Heces/química , Heces/microbiología , Femenino , Humanos , Masculino , Uso Excesivo de los Servicios de Salud , Persona de Mediana Edad , Técnicas de Amplificación de Ácido Nucleico , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...