Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Acta Oncol ; 61(1): 89-96, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34783610

RESUMEN

BACKGROUND: Accurate target volume delineation is a prerequisite for high-precision radiotherapy. However, manual delineation is resource-demanding and prone to interobserver variation. An automatic delineation approach could potentially save time and increase delineation consistency. In this study, the applicability of deep learning for fully automatic delineation of the gross tumour volume (GTV) in patients with anal squamous cell carcinoma (ASCC) was evaluated for the first time. An extensive comparison of the effects single modality and multimodality combinations of computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) have on automatic delineation quality was conducted. MATERIAL AND METHODS: 18F-fluorodeoxyglucose PET/CT and contrast-enhanced CT (ceCT) images were collected for 86 patients with ASCC. A subset of 36 patients also underwent a study-specific 3T MRI examination including T2- and diffusion-weighted imaging. The resulting two datasets were analysed separately. A two-dimensional U-Net convolutional neural network (CNN) was trained to delineate the GTV in axial image slices based on single or multimodality image input. Manual GTV delineations constituted the ground truth for CNN model training and evaluation. Models were evaluated using the Dice similarity coefficient (Dice) and surface distance metrics computed from five-fold cross-validation. RESULTS: CNN-generated automatic delineations demonstrated good agreement with the ground truth, resulting in mean Dice scores of 0.65-0.76 and 0.74-0.83 for the 86 and 36-patient datasets, respectively. For both datasets, the highest mean Dice scores were obtained using a multimodal combination of PET and ceCT (0.76-0.83). However, models based on single modality ceCT performed comparably well (0.74-0.81). T2W-only models performed acceptably but were somewhat inferior to the PET/ceCT and ceCT-based models. CONCLUSION: CNNs provided high-quality automatic GTV delineations for both single and multimodality image input, indicating that deep learning may prove a versatile tool for target volume delineation in future patients with ASCC.


Asunto(s)
Neoplasias del Ano , Aprendizaje Profundo , Neoplasias de Cabeza y Cuello , Neoplasias del Ano/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Carga Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA