Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Eng Sci Med ; 46(2): 801-812, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37052806

RESUMEN

Cone-beam computed tomography (CBCT), derived from multidetector row CT (MDCT), has a high spatial resolution and has recently been applied to various organs. One of the severe limitations common to CBCT and MDCT is metal artifacts. In particular, streak metal artifacts (SMAs) between multiple metal materials often hinder diagnosis. However, no studies have quantitatively compared the strength of SMAs in MDCT and CBCT. Nomura et al. reported an evaluation method specialized in SMAs of CBCT using the Gumbel distribution (GD), which can also be applied to SMAs of MDCT (Oral Surg Oral Med Oral Pathol Oral Radiol 131: 494-502, 2021, https://doi.org/10.1016/J.OOOO.2020.08.031 ). This study aimed to quantitatively compare SMAs occurring between titanium materials on MDCT and CBCT images using the GD-based method. The SMAs were investigated as follows: A hydroxyapatite block was sandwiched between two titanium rods to generate an SMA. They were placed in an acrylic phantom, simulating a human head, and scanned using an MDCT scanner and two CBCT scanners. The obtained images were analyzed using Gumbel plots and location parameters, and the SMA strength was calculated. The results showed that the SMAs on the MDCT images were significantly weaker than those on the CBCT images. In the CBCT scans, a smaller volume CT dose index value caused stronger SMAs. These results indicate that MDCT is more advantageous than CBCT in terms of SMA reduction when bone morphology between titanium materials must be evaluated. The characteristic should be considered in clinical cases.


Asunto(s)
Artefactos , Titanio , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Multidetector/métodos , Fantasmas de Imagen
2.
Oral Radiol ; 39(2): 235-241, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35689759

RESUMEN

OBJECTIVES: To determine the magnetic resonance imaging (MRI) features of methotrexate-related lymphoproliferative disorder (MTX-LPD) in the oral cavity of a patient with a chief complaint of oral symptoms. METHODS: We included six patients who visited our hospital between November 2014 and November 2019, histopathologically diagnosed with MTX-LPD. All images were examined using 3 T MRI and reviewed by two radiologists. RESULTS: Masses were detected in five cases; all masses demonstrated signal hypointensity and homogeneous signal hyperintensity on T1- and T2-weighted images with fat suppression. Homogeneous enhancement with fat suppression was evident on post-contrast T1-weighted imaging. We performed dynamic contrast-enhanced MRI in three cases and observed early enhancement with a low washout ratio pattern in all cases. Four patients underwent diffusion-weighted MRI and revealed low mean apparent diffusion coefficient (ADC) of 0.57 (range 0.5-0.65) × 10-3 mm2/s. CONCLUSIONS: We reported on the imaging characteristics of six rare cases of MTX-LPD in the oral cavity. Homogeneous hyperintensity on fat-suppressed T2-weighted images and low ADC values are possible features of MTX-LPD. Moreover, MTX-LPD can be differentiated from other carcinomas in the oral cavity.


Asunto(s)
Artritis Reumatoide , Trastornos Linfoproliferativos , Humanos , Metotrexato/efectos adversos , Artritis Reumatoide/patología , Imagen por Resonancia Magnética , Imagen de Difusión por Resonancia Magnética , Trastornos Linfoproliferativos/inducido químicamente , Trastornos Linfoproliferativos/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...