Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Phys Eng Sci Med ; 47(2): 717-727, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38451464

RESUMEN

Contrast resolution is an important index for evaluating the signal detectability of computed tomographic (CT) images. Recently, various noise reduction algorithms, such as iterative reconstruction (IR) and deep learning reconstruction (DLR), have been proposed to reduce the image noise in CT images. However, these algorithms cause changes in the image noise texture and blurred image signals in CT images. Furthermore, the contrast-to-noise ratio (CNR) cannot be accurately evaluated in CT images reconstructed using noise reduction methods. Therefore, in this study, we devised a new method, namely, "effective CNR analysis," for evaluating the contrast resolution of CT images. We verified whether the proposed algorithm could evaluate the effective contrast resolution based on the signal detectability of CT images. The findings showed that the effective CNR values obtained using the proposed method correlated well with the subjective visual impressions of CT images. To investigate whether signal detectability was appropriately evaluated using effective CNR analysis, the conventional CNR analysis method was compared with the proposed method. The CNRs of the IR and DLR images calculated using conventional CNR analysis were 13.2 and 10.7, respectively. By contrast, those calculated using the effective CNR analysis were estimated to be 0.7 and 1.1, respectively. Considering that the signal visibility of DLR images was superior to that of IR images, our proposed effective CNR analysis was shown to be appropriate for evaluating the contrast resolution of CT images.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Relación Señal-Ruido , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Fantasmas de Imagen
3.
J Neuroendovasc Ther ; 16(12): 586-592, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37502666

RESUMEN

Objective: Neuroendovascular treatments are less invasive than surgical clipping. However, the number of fluoroscopy runs may be greater when a contrast medium is used than when routine angiography is performed. Several recent studies have suggested that an iodinated contrast medium causes an increase in the radiation dose. Therefore, it is clinically important to identify physical factors causing amplification of the radiation dose. The purpose of this study was to investigate how dilution of a contrast medium with water influences the amplification effect of the radiation dose using simulation analysis. Methods: Three different types of commercially available contrast media, namely, iopamidol, iohexol, and iodixanol, were diluted 1.7-3.3 times with water and placed in the left brain parenchyma of a numerical brain phantom. Using the Monte Carlo simulation method, the phantom was exposed to X-ray beams under constant exposure conditions, and the energy absorbed in the entire region of the left brain parenchyma was estimated. At the same time, the content and volume of a contrast medium in the cerebral vessels were predicted on the basis of pharmacokinetic and fractal analyses. Results: The increase in absorbed energy was attributed to secondary electrons emitted from the contrast medium and varied depending on its content and volume. Interestingly, the amount of energy absorbed increased with increasing dilution of the contrast medium. Furthermore, the amplification effect of the radiation dose varied according to the type of contrast medium used. Conclusion: These results suggest that the amplification effect of the radiation dose is closely related to an increase in the cross-sectional area in which the X-rays interact with the contrast medium, which is caused by increased distribution of contrast medium in the cerebral vessels. When the contrast medium is diluted with water, its spread in the cerebral vessels plays a more important role than its content in the amplification effect of the radiation dose.

5.
Eur J Radiol Open ; 5: 183-188, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30310828

RESUMEN

PURPOSE: To investigate the contrast enhancement in DSA images based on the X-ray absorption characteristics of iodinated contrast media. METHODS: We have derived a new formula of predicting the pixel value ratio of two different contrast media and designate it as "Contrast Enhancement Ratio (CER)". In order to evaluate the accuracy of CER, we have evaluated the relationship between CER and pixel value ratio for all combinations of eleven iodinated contrast media. The non-ionic iodinated contrast media, iopamidol, iomeprol, iopromide, ioversol, iohexol, and iodixanol, were evaluated in this study. Each contrast medium was filled in the simulated blood vessel in our constructed anthropomorphic phantom, and DSA images were obtained using an angiographic imaging system. To evaluate the contrast enhancement of the contrast medium, the mean pixel value was calculated from all pixel values in the vascular image. RESULTS: CER was indicated to agree well with the pixel value ratio of two different contrast medium solutions and showed a good accuracy. CER was also shown to have a good linear relation to the pixel value ratio when the iodine concentration was constant. This means that the molecular structure of the contrast media affects contrast enhancement efficacy. Furthermore, in evaluation of contrast enhancement of iodinated contrast media by using the weight factor (that is a key factor in CER) ratio, Iodixanol, and iopamidol, and iomeprol have the same ability of contrast enhancement in DSA images, and iohexol shows the lowest ability. CONCLUSIONS: We have derived a new formula (CER) of predicting the pixel value ratio of two different contrast medium solutions, and shown that CER agreed well with the pixel value ratio for blood vessel filled with eleven contrast media.

6.
J Radiol Prot ; 37(3): 659-683, 2017 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-28516892

RESUMEN

Since the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens of the eye in 2011, there have been extensive discussions in various countries. This paper reviews the current situation in radiation protection of the ocular lens and the discussions on the potential impact of the new lens dose limit in Japan. Topics include historical changes to the lens dose limit, the current situation with occupational lens exposures (e.g., in medical workers, nuclear workers, and Fukushima nuclear power plant workers) and measurements, and the current status of biological studies and epidemiological studies on radiation cataracts. Our focus is on the situation in Japan, but we believe such information sharing will be useful in many other countries.


Asunto(s)
Cristalino/efectos de la radiación , Exposición Profesional/normas , Dosis de Radiación , Traumatismos por Radiación/prevención & control , Relación Dosis-Respuesta en la Radiación , Humanos , Japón , Medición de Riesgo
7.
Int J Comput Assist Radiol Surg ; 10(1): 1-10, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24760179

RESUMEN

PURPOSE: Arterial contour extraction is essential for visualization and analysis of vasculature in CT angiography (CTA). A means for evaluating the detectability of artery contours CTA images is required. We developed and tested a new method for this purpose based on phase information from two-dimensional Fourier transforms of CTA images. The relationship between arterial contour detectability and a patient's ocular lens dose was evaluated in CTA images obtained with various tube voltages and currents. METHODS: A head phantom was designed for use as a target object containing a simulated vascular tree, filled with dilute contrast medium (10 mg iodine/ml). The head phantom was scanned using a 64-multidetector CT scanner with tube voltages of 80-140 kV and tube currents corresponding to volume CT dose index [Formula: see text] ranging from 24.4 to 72.8 mGy. Lens doses were measured using the planar silicon PIN-photodiode system. The quality of artery contours in the CTA source images was assessed using a computed detectability index. RESULTS: Lens dose increased proportionally with tube voltage and current. The use of 80 kV provided the highest contour detectability. However, for each tube voltage, the detectability of artery contours was almost constant across the CTDI(vol) values. These results were mostly consistent with the subjective recognition of artery contours on CTA images. CONCLUSIONS: A CTA protocol using 80 kV and 420 mA can reduce the radiation exposure to ocular lens by approximately 40 %, and improve the artery contour detectability compared with a routine protocol.


Asunto(s)
Angiografía/métodos , Arterias , Cabeza/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Humanos , Dosis de Radiación
8.
Australas Phys Eng Sci Med ; 36(3): 313-22, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23955765

RESUMEN

The automated contrast-detail (C-D) analysis methods developed so-far cannot be expected to work well on images processed with nonlinear methods, such as noise reduction methods. Therefore, we have devised a new automated C-D analysis method by applying support vector machine (SVM), and tested for its robustness to nonlinear image processing. We acquired the CDRAD (a commercially available C-D test object) images at a tube voltage of 120 kV and a milliampere-second product (mAs) of 0.5-5.0. A partial diffusion equation based technique was used as noise reduction method. Three radiologists and three university students participated in the observer performance study. The training data for our SVM method was the classification data scored by the one radiologist for the CDRAD images acquired at 1.6 and 3.2 mAs and their noise-reduced images. We also compared the performance of our SVM method with the CDRAD Analyser algorithm. The mean C-D diagrams (that is a plot of the mean of the smallest visible hole diameter vs. hole depth) obtained from our devised SVM method agreed well with the ones averaged across the six human observers for both original and noise-reduced CDRAD images, whereas the mean C-D diagrams from the CDRAD Analyser algorithm disagreed with the ones from the human observers for both original and noise-reduced CDRAD images. In conclusion, our proposed SVM method for C-D analysis will work well for the images processed with the non-linear noise reduction method as well as for the original radiographic images.


Asunto(s)
Algoritmos , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Máquina de Vectores de Soporte , Tomografía Computarizada por Rayos X/métodos , Humanos , Dinámicas no Lineales , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación
9.
Radiat Prot Dosimetry ; 153(1): 85-91, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22645383

RESUMEN

Radiation doses in paediatric computed tomography (CT) were investigated for various types of recent CT scanners with newborn and 6-y-old phantoms in which silicon-photodiode dosemeters were implanted at various organ positions. In the head, chest and abdominal CT for the newborn phantom, doses for organs within the scan region were 21-40, 3-8 and 3-12 mGy, respectively. The corresponding doses for the child phantom were 20-37, 2-11 and 4-17 mGy, respectively. In the head, chest and abdominal CT, the effective doses were respectively 2.1-3.3, 2.0-6.0 and 2.2-10.0 mSv for the newborn, and 1.0-2.0, 1.2-6.6 and 2.9-11.8 mSv for the child. Radiation doses for the newborn were at the same levels as those for the child, excepting effective doses in head CT for the newborn, which were 1.8 times higher than those for the child.


Asunto(s)
Cabeza/diagnóstico por imagen , Fantasmas de Imagen , Radiografía Abdominal , Radiografía Torácica , Radiometría/instrumentación , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X , Carga Corporal (Radioterapia) , Niño , Humanos , Recién Nacido , Fotoquímica , Semiconductores , Silicio/química
10.
Radiat Prot Dosimetry ; 154(3): 314-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23019596

RESUMEN

Organ and effective doses during paediatric chest radiographic examination were investigated for various tube voltages between 60 and 110 kV at a constant milliampere-second value and focus-to-film distance by using an in-phantom dose measuring system and a Monte Carlo (MC) simulation software (PCXMC), where the former was composed of 32 photodiode dosemeters embedded in various tissue and organ sites within a 6-y-old child anthropomorphic phantom. Lung doses obtained ranged from 0.010 to 0.066 mGy and effective doses from 0.004 to 0.025 mSv, where these doses varied by a factor of 6 with the change in the tube voltage. Effective doses obtained using the MC simulation software agreed with those obtained using the dose measuring system within 23 %, revealing the usefulness of PCXMC software for evaluating effective doses. The present study would provide helpful dose data for the selection of technical parameters in paediatric chest radiography in Japan.


Asunto(s)
Especificidad de Órganos , Pediatría/instrumentación , Fotometría/instrumentación , Dosis de Radiación , Radiografía Torácica/instrumentación , Radiometría/instrumentación , Semiconductores , Carga Corporal (Radioterapia) , Niño , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Silicio/efectos de la radiación
11.
Med Phys ; 37(11): 5579-85, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21158269

RESUMEN

PURPOSE: The aim of this study was to evaluate radiation dose to patients undergoing computed tomography coronary angiography (CTCA) for prospectively gated axial (PGA) technique and retrospectively gated helical (RGH) technique. METHODS: Radiation doses were measured for a 320-detector row CT scanner (Toshiba Aquilion ONE) using small sized silicon-photodiode dosimeters, which were implanted at various tissue and organ positions within an anthropomorphic phantom for a standard Japanese adult male. Output signals from photodiode dosimeters were read out on a personal computer, from which organ and effective doses were computed according to guidelines published in the International Commission on Radiological Protection Publication 103. RESULTS: Organs that received high doses were breast, followed by lung, esophagus, and liver. Breast doses obtained with PGA technique and a phase window width of 16% at a simulated heart rate of 60 beats per minute were 13 mGy compared to 53 mGy with RGH technique using electrocardiographically dependent dose modulation at the same phase window width as that in PGA technique. Effective doses obtained in this case were 4.7 and 20 mSv for the PGA and RGH techniques, respectively. Conversion factors of dose length product to the effective dose in PGA and RGH were 0.022 and 0.025 mSv mGy(-1) cm(-1) with a scan length of 140 mm. CONCLUSIONS: CTCA performed with PGA technique provided a substantial effective dose reduction, i.e., 70%-76%, compared to RGH technique using the dose modulation at the same phase windows as those in PGA technique. Though radiation doses in CTCA with RGH technique were the same level as, or some higher than, those in conventional coronary angiography (CCA), the use of PGA technique reduced organ and effective doses to levels less than CCA except for breast dose.


Asunto(s)
Angiografía Coronaria/métodos , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Humanos , Masculino , Fantasmas de Imagen , Estudios Retrospectivos , Factores de Tiempo , Distribución Tisular , Tomógrafos Computarizados por Rayos X
12.
Med Phys ; 37(8): 4298-306, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20879590

RESUMEN

PURPOSE: The objective of this study was to evaluate organ dose and the effective dose to patients undergoing tomosynthesis (TS) and C-arm cone-beam computed tomography (CBCT) examinations and to compare the doses to those in multidetector CT (MDCT) scans. METHODS: Patient doses were measured with small sized silicon-photodiode dosimeters, 48 in number, which were implanted at various tissue and organ positions within an anthropomorphic phantom. Output signals from photodiode dosimeters were read out on a personal computer, from which organ and effective doses were computed. The doses in head, chest, abdomen, and hip-joint TS, and in head and abdomen C-arm CBCT were evaluated for routine protocols on Shimadzu TS and C-arm CBCT systems, and the doses in MDCT with the same scan regions as in TS and CBCT were on Toshiba 64-detector-row CT scanners. RESULTS: In TS examination of the head, chest, abdomen, and hip-joint, organ doses for organs within scan ranges were 1-4 mGy, and effective doses were 0.07 mSv for the head scan and around 1 mSv for other scans. In C-arm CBCT examinations of the head and abdomen, organ doses within scan range were 2-37 mGy, and effective doses were 1.2 mSv for the head scan and 4-5 mSv for abdominal scans. Effective doses in TS examinations were approximately a factor of 10 lower, while the doses in CBCT examinations were nearly the same level, compared to the doses in the corresponding MDCT examinations. CONCLUSIONS: TS examinations with low doses and excellent resolutions in coronal images compared to recent MDCT would widely be used in tomographic examinations of the chest, abdomen, pelvis, skeletal-joints, and knee instead of MDCT examinations with significantly high doses. Since patient dose in C-arm CBCT was nearly the same level as that in recent MDCT, the same consideration for high radiation dose would be required for the use of CBCT.


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Fantasmas de Imagen , Radiometría/instrumentación , Radioterapia Conformacional/instrumentación , Antropometría/instrumentación , Carga Corporal (Radioterapia) , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Pediatr Radiol ; 40(7): 1206-14, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20066408

RESUMEN

BACKGROUND: CT examinations of the head and neck are the most commonly performed CT studies in children, raising concern about radiation dose and their risks to children. OBJECTIVE: The purpose of this study was to clarify radiation dose levels for children of 6 years of age undergoing head and neck multidetector CT (MDCT) examinations. MATERIALS AND METHODS: Radiation doses were measured with small-sized silicon-photodiode dosimeters that were implanted at various tissue and organ positions within a standard 6-year-old anthropomorphic phantom. Organ and effective doses of brain CT were evaluated for 19 protocols in nine hospitals on various (2-320 detector rows) MDCT scanners. RESULTS: The maximum value of mean organ dose in brain CT was 34.3 mGy for brain. Maximum values of mean doses for the radiosensitive lens and thyroid were 32.7 mGy for lens in brain CT and 17.2 mGy for thyroid in neck CT. seventy-fifth percentile of effective dose distribution in brain CT was approximately the same as the diagnostic reference level (DRL) in the 2003 UK survey. CONCLUSION: The results of this study would encourage revision of MDCT protocols in pediatric head and neck CT examinations for dose reduction and protocol standardization.


Asunto(s)
Carga Corporal (Radioterapia) , Cabeza/diagnóstico por imagen , Cuello/diagnóstico por imagen , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Niño , Femenino , Humanos , Masculino , Efectividad Biológica Relativa
14.
Radiat Prot Dosimetry ; 136(1): 38-44, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19617599

RESUMEN

The purpose of this study was to clarify patient doses in the current otolaryngological multi-detector row computed tomography (MDCT) examinations. Patient doses were measured with an in-phantom dosimetry system which was composed of 48 photodiode dosimeters embedded within an anthropomorphic phantom. Organ and effective doses were evaluated according to the International Commission on Radiological Protection Publication 103. In neck CT, doses for salivary glands and for thyroid were high, 7.6-29.9 and 13.4-60.3 mGy, respectively. In sinus CT, brain and lens doses were high, 7.6-24.6 and 10.6-32.0 mGy, respectively, and in inner ear CT, lens dose was 8.0-35.3 mGy. Effective doses were 1.8-6.6 mSv in neck CT, 0.5-0.9 mSv in sinus CT and 0.3-0.6 mSv in inner ear CT. The present dose data would be used to estimate radiation risks for patients undergoing otolaryngological MDCT examinations.


Asunto(s)
Enfermedades Otorrinolaringológicas/diagnóstico por imagen , Dosis de Radiación , Radiometría/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Humanos , Fantasmas de Imagen/estadística & datos numéricos
15.
Radiat Prot Dosimetry ; 118(4): 421-30, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16439515

RESUMEN

Organ and the effective doses of patients undergoing clinical X ray examinations of chest and abdomen were evaluated with an anthropomorphic phantom and a new dosimetry system. The system was comprised of 34 pin photodiode dosemeters placed in/on particular tissues or organs of the anthropomorphic phantom, where the tissues and organs are defined by the International Commission on Radiological Protection (ICRP) to estimate the effective doses. Dosemeter signals were acquired on a personal computer directly, and converted into absorbed doses, from which the organ and the effective doses were evaluated on the computer. Our study showed that organ doses ranged from <0.01 to 0.72 mGy in routine X-ray radiography of chest and of abdomen and from 0.07 to 55.91 mGy in routine computed tomography (CT) examinations with current multi-slice CT scanners. The effective dose observed in the chest CT examination was approximately 300 times higher than that in chest radiography.


Asunto(s)
Fantasmas de Imagen , Radiometría/instrumentación , Radiometría/métodos , Tomografía Óptica/instrumentación , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Masculino , Fotoquímica/instrumentación , Silicio , Tomografía Óptica/métodos
16.
Igaku Butsuri ; 24(1): 21-30, 2004.
Artículo en Japonés | MEDLINE | ID: mdl-15226646

RESUMEN

In the present study we describe the evaluation of the effectiveness of gonad protection in diagnostic radiology based on the measurement of organ and the effective doses with and without lead clothing to gonads. We devised in-phantom dosimetry system and measured organ and effective doses in x-ray radiography and CT examinations with the new dosimetry system. From the data of organ and the effective doses we assessed the effectiveness of radiological protection by the use of lead clothing to gonads. Although in chest radiography and chest CT examinations, the effectiveness of radiological protection was not found, in the case of hip joint radiography (AP), gonad doses decreased remarkably by using lead clothing. The effectiveness of radiological protection, i.e. the ratio of the decreased dose to the dose value without protection, in testis and ovary were found to be 91.4% and 68.0%, respectively. It was also found that gonad doses observed with and without gonad protection were extremely lower than those of threshold for sterility recommended by the International Commission on Radiological Protection 60 (ICRP Publ. 60).


Asunto(s)
Dosis de Radiación , Protección Radiológica , Gónadas , Humanos , Fantasmas de Imagen , Radiometría , Tomografía Computarizada por Rayos X
17.
Med Phys ; 29(7): 1504-10, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12148731

RESUMEN

A dosimetry system using commercially available pin silicon photodiodes as the sensor is evaluated for in-phantom dose measurements in x-ray CT and other diagnostic radiology. System sensitivity measured as a function of the effective energy of x rays was between 0.37 and 0.49 V/mGy at an effective energy range between 23.5 and 72 keV. The minimum detectable organ dose with 25% uncertainty was estimated to be 0.02 mGy. The excellent output linearity was found over a dose range from 0.03 to more than 10 mGy with flat dose rate response of system sensitivity up to 35 mGy s(-1), though the sensitivity indicated some energy dependence across the diagnostic energy range with a maximum of about 10%/10 keV. Since angular dependence of the sensitivity of the photodiode sensor was found to be small enough it would induce negligible dose error. Dose profile measurement along the axis of a thoracic phantom undergoing CT chest examination indicated the reliability of dose values over a range of two orders of magnitude from less than 0.2 to 12 mGy. The present dosimetry system having advantages of high sensitivity with immediate readout of dose values, low cost, and easy construction would widely be used as an alternative to TLD dosimeters for organ and skin dose measurements in CT and other diagnostic radiology.


Asunto(s)
Radiometría/instrumentación , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Relación Dosis-Respuesta en la Radiación , Humanos , Luz , Fantasmas de Imagen , Radiografía Torácica , Sensibilidad y Especificidad , Silicio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...