Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Environ Monit Assess ; 194(9): 643, 2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35930070

RESUMEN

The present study demonstrates the spatial analysis and mapping of fish and different measures of environmental parameters and fish diversity of Pong reservoir, Himachal Pradesh, using Kriging spatial interpolation methods for geographical information system mapping. Seasonal data on environmental parameters, potential fish habitat and fish diversity was collected from lentic (dam), lentic (reservoir), transitional and lotic zone of the reservoir.. Important environmental parameters like water temperature, dissolved oxygen, electrical conductivity, water depth and transparency showed variations across the different zones of the reservoir. The sediment of the reservoir was sandy clay loam in nature as per texture analysis. Fish species richness, Shannon index and evenness index showed a similarity of the lotic and lentic (reservoir) zones of the reservoir. Six potential fish breeding grounds were identified in the reservoir indicating high conservation significance. The analysis of data showed a declining trend in fish production from 456.9 tonnes during the decade 1976-1987 to 347.91 tonnes during 2009-2020. The factors like anthropogenic climate change, predation of a stocked fish juvenile by water birds, undersized fish stocking and unscientific management are the probable reasons for the decreasing fish production. The spatial variation pattern of the water spread area, environmental parameters, fish catch and potential fish breeding grounds depicted in the GIS platform can be used as an important information base by the policy makers for fisheries management. The stocking of large size fish as a stocking material and adequate protection of the potential fish breeding grounds are the key advisories for the sustainable enhancement of fisheries as well as conservation.


Asunto(s)
Biodiversidad , Sistemas de Información Geográfica , Animales , Ecosistema , Monitoreo del Ambiente , Peces , Agua
2.
J Mech Behav Biomed Mater ; 115: 104294, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33383376

RESUMEN

The valve replacement therapy is the standard treatment for severe heart valve diseases. Nowadays, two types of commercial prosthesis are available: mechanical and biological, but both of them have severe limitations. Moreover, alternative therapeutic approach for valve replacement, based on minimally invasive techniques (MIAVR), motivates the search for new valve materials. In this study a polyurethane-based self-expandable tri-leaflets heart valve compatible with MIAVR procedure is proposed. The device is based on the development, fabrication and characterization of three different elements: the leaflets, the polymeric stent for supporting the leaflets, and the external metallic stent for anchoring the valve to the native aortic root. The polymeric stent and the valve leaflets were fabricated using a thermoplastic silicone-polycarbonate-urethane using 3D printing and spray technology while the external metallic stent was made in nickel titanium (Nitinol) to obtain a self-expandable valve after the crimping process. The three elements were assembled in the completed device and tested by crimping, fatigue and fluid-dynamic test. The novel polymeric valve proposed showed promising results about valve crimping capabilities, durability and fluid dynamic performances. This approach could offer advantages such as low cost and to produce a tailor-made device basing on patient's imaging data. Moreover, the selected biomaterial offers the potential to have a device that could need of permanent anticoagulation and lack of calcification.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica , Humanos , Diseño de Prótesis , Stents
3.
JPEN J Parenter Enteral Nutr ; 13(4): 438-9, 1989.
Artículo en Inglés | MEDLINE | ID: mdl-2778945

RESUMEN

Malposition of a central venous catheter occurs despite improvements in catheter design and regardless of the skill of the physician. A simple method of repositioning a central venous catheter has been successful in 25 of 25 attempts. Documentation of the rationale for the use of this technique is provided using x-rays.


Asunto(s)
Cateterismo Venoso Central/métodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...