1.
Biomed Tech (Berl) ; 63(6): 691-697, 2018 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-28915105

RESUMEN

Previous research investigated recumbent cycle power output (PO) from the perspective of knee and hip joint biomechanics. However, ankle-foot biomechanics and, in particular, the effect of ankle-foot orthosis (AFO)-constrained movements on cycle PO has not been widely explored. Therefore, the purpose of this study was to determine whether AFOs of a fixed position (FP) and in dorsi-plantarflexion (DPF)-, dorsiflexion (DF)- and plantarflexion (PF)-constrained movements might influence PO during voluntary recumbent cycling exercises. Twenty-five healthy individuals participated in this study. All underwent 1-min cycling at a fixed cadence for each of the AFOs. The peak and average PO of each condition were analyzed. The peak and average PO were 27.2±12.0 W (range 6-60) and 17.2±9.0 W (range 2-36), respectively, during voluntary cycling. There were no significant differences in the peak PO generated by the AFOs (p=0.083). There were also no significant differences in the average PO generated using different AFOs (p=0.063). There were no significant differences in the changes of the hip and knee joint angles with different AFOs (p=0.974 and p=1.00, respectively). However, there was a significant difference in the changes of the ankle joint angle (p<0.00). The present study observed that AFO-constrained movements did not have an influence in altering PO during voluntary recumbent cycling in healthy individuals. This finding might serve as a reference for future rehabilitative cycling protocols.


Asunto(s)
Articulación del Tobillo/patología , Marcha/fisiología , Inestabilidad de la Articulación/fisiopatología , Rango del Movimiento Articular/fisiología , Ciclismo , Ortesis del Pié , Humanos
2.
Med Eng Phys ; 38(8): 767-75, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27289541

RESUMEN

The interaction between muscle contractions and joint loading produces torques necessary for movements during activities of daily living. However, during neuromuscular electrical stimulation (NMES)-evoked contractions in persons with spinal cord injury (SCI), a simple and reliable proxy of torque at the muscle level has been minimally investigated. Thus, the purpose of this study was to investigate the relationships between muscle mechanomyographic (MMG) characteristics and NMES-evoked isometric quadriceps torques in persons with motor complete SCI. Six SCI participants with lesion levels below C4 [(mean (SD) age, 39.2 (7.9) year; stature, 1.71 (0.05) m; and body mass, 69.3 (12.9) kg)] performed randomly ordered NMES-evoked isometric leg muscle contractions at 30°, 60° and 90° knee flexion angles on an isokinetic dynamometer. MMG signals were detected by an accelerometer-based vibromyographic sensor placed over the belly of rectus femoris muscle. The relationship between MMG root mean square (MMG-RMS) and NMES-evoked torque revealed a very high association (R(2)=0.91 at 30°; R(2)=0.98 at 60°; and R(2)=0.97 at 90° knee angles; P<0.001). MMG peak-to-peak (MMG-PTP) and stimulation intensity were less well related (R(2)=0.63 at 30°; R(2)=0.67 at 60°; and R(2)=0.45 at 90° knee angles), although were still significantly associated (P≤0.006). Test-retest interclass correlation coefficients (ICC) for the dependent variables ranged from 0.82 to 0.97 for NMES-evoked torque, between 0.65 and 0.79 for MMG-RMS, and from 0.67 to 0.73 for MMG-PTP. Their standard error of measurements (SEM) ranged between 10.1% and 31.6% (of mean values) for torque, MMG-RMS and MMG-PTP. The MMG peak frequency (MMG-PF) of 30Hz approximated the stimulation frequency, indicating NMES-evoked motor unit firing rate. The results demonstrated knee angle differences in the MMG-RMS versus NMES-isometric torque relationship, but a similar torque related pattern for MMG-PF. These findings suggested that MMG was well associated with torque production, reliably tracking the motor unit recruitment pattern during NMES-evoked muscle contractions. The strong positive relationship between MMG signal and NMES-evoked torque production suggested that the MMG might be deployed as a direct proxy for muscle torque or fatigue measurement during leg exercise and functional movements in the SCI population.


Asunto(s)
Estimulación Eléctrica , Contracción Isométrica , Fenómenos Mecánicos , Músculo Cuádriceps/fisiopatología , Traumatismos de la Médula Espinal/fisiopatología , Torque , Actividades Cotidianas , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procesamiento de Señales Asistido por Computador