Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Luminescence ; 39(8): e4837, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39113185

RESUMEN

During the pandemic, Favipiravir (FVP) and Molnupiravir (MPV) have been widely used for COVID-19 treatment, leading to their presence in the environment. A green synchronous spectrofluorimetric method was developed to simultaneously detect them in environmental water, human plasma, and binary mixtures. Maximum fluorescence intensity was achieved at pH 8, with MPV exhibiting two peaks at 300 and 430 nm, and FVP showing one peak at 430 nm. A fluorescence subtraction method effectively removed interference, enabling direct determination of MPV at 300 nm and FVP at 430 nm. The method showed linearity within 2-13 ng/mL for FVP and 50-600 ng/mL for MPV, with recoveries of 100.35% and 100.12%, respectively. Limits of detection and quantification were 0.19 and 0.57 ng/mL for FVP and 10.52 and 31.88 ng/mL for MPV. Validation according to ICH and FDA guidelines yielded acceptable results. The method demonstrated good recoveries of FVP and MPV in pharmaceuticals, tap water and Nile water (99.62% ± 0.96% and 99.69% ± 0.64%) as per ICH guidelines and spiked human plasma (94.87% ± 2.111% and 94.79% ± 1.605%) following FDA guidelines, respectively. Its environmental friendliness was assessed using Green Analytical Procedure Index (GAPI) and the Analytical Greenness Metric (AGREE) tools.


Asunto(s)
Amidas , Antivirales , Pirazinas , Espectrometría de Fluorescencia , Pirazinas/análisis , Pirazinas/sangre , Pirazinas/química , Amidas/análisis , Amidas/química , Amidas/sangre , Espectrometría de Fluorescencia/métodos , Humanos , Antivirales/análisis , Antivirales/sangre , Uridina/análisis , Uridina/sangre , Límite de Detección , Citidina/análisis , Citidina/sangre , Citidina/análogos & derivados , Tratamiento Farmacológico de COVID-19 , Mercaptopurina/sangre , Mercaptopurina/análisis , SARS-CoV-2 , Hidroxilaminas
2.
Sci Rep ; 14(1): 19873, 2024 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-39191859

RESUMEN

There are no documented electroanalytical methods for quantifying the anti-inflammatory drug bumadizone (BUM) in pharmaceutical or biological matrices. So, a new voltammetric method was developed to determine BUM at nano concentrations in pharmaceutical forms, in the presence of its alkaline degradant, and in biological fluids. Five electrodes were tested, including three nano-reduced graphene oxide (nRGO) electrodes (5%, 15%, and 20%), a carbon paste electrode (CPE), and a 10% nRGO-modified CPE. The 10% nRGO-modified electrode showed the best performance, offering high selectivity and low detection limits, with good linearity in the concentration range of 0.9 × 102 to 15 × 102 ng mL-1. Differential pulse voltammetry successfully applied this electrode for BUM determination in various samples, achieving excellent recovery without preliminary separation. The method was validated according to ICH guidelines and compared favorably to the reference method. Its environmental impact was assessed using AGREE and Eco-scale metrics in addition to the RGB algorithm, showing superior greenness and whiteness profiles due to safer solvents and lower energy consumption, along with high practical effectiveness using the BAGI metric.


Asunto(s)
Técnicas Electroquímicas , Electrodos , Grafito , Grafito/química , Técnicas Electroquímicas/métodos , Humanos , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/química , Límite de Detección
3.
BMC Chem ; 18(1): 56, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38521957

RESUMEN

Gold and silver nanoparticles have witnessed increased scientific interest due to their colourful colloidal solutions and exceptional applications. Comparing the localized surface plasmon resonance (LSPR) of gold and silver nanoparticles is crucial for understanding and optimizing their optical properties. This comparison informs the design of highly sensitive plasmonic sensors, aids in selecting the most suitable nanoparticles for applications like surface-enhanced infrared spectroscopy (SEIRA) and biomedical imaging, and guides the choice between gold and silver nanoparticles based on their catalytic and photothermal properties. Ultimately, the study of LSPR facilitates the tailored use of these nanoparticles in diverse scientific and technological applications. Two SEIRA methods combined with partial least squares regression (PLSR) chemometric tools were developed. This development is based on the synthesis of homogeneous, high-dense deposited metal nanoparticle islands over the surface of glass substrates to be used as lab-on-chip SEIRA sensors for the determination of bisacodyl (BIS) and its active metabolite in plasma. SEM micrographs revealed the formation of metallic islands of colloidal citrate-capped gold and silver nanoparticles of average sizes of 29.7 and 15 nm, respectively. BIS and its active metabolite were placed on the nanoparticles' coated substrates to be directly measured, then PLSR chemometric modelling was used for the quantitative determinations. Plasmonic citrate-capped gold nanoparticle substrates showed better performance than those prepared using citrate-capped silver nanoparticles in terms of preparation time, enhancement factor, PLSR model prediction, and quantitative results. This study offers a way to determine BIS and its active metabolite in the concentration range 15-240 ng/mL in human plasma using inexpensive disposable glass-coated substrates that can be prepared in 1 h to get results in seconds with good recovery between 98.77 and 100.64%. The sensors provided fast, simple, selective, molecular-specific and inexpensive procedures to determine molecules in their pure form and biological fluid.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38301337

RESUMEN

The integration of molecular imprinting technique with chromatographic one has a great impact on the assay's selectivity and sensitivity. Herein, a molecularly imprinted solid-phase extraction associated with high performance liquid chromatography (MISPE-HPLC) was employed for simultaneous determination of the co-formulated drugs; tetracycline hydrochloride (TET) and metronidazole (MET), in plasma and in their anti-H-pylori drug for the first time. Two sorts of molecularly imprinted polymers (MIPs) were fabricated using TET and MET as the template molecules, while ethylene glycol dimethacrylate and methacrylic acid were used as a cross-linker and a monomer, respectively. The synthesized MIPs were identified using different techniques. The adsorption-desorption capability of each template was investigated towards its corresponding MIP. The extraction conditions of MISPE was optimized with respect to TET/MIP and MET/MIP sorbent. Bismuth subcitrate (BSC), the third co-formulated drug was analyzed in spiked human plasma using an atomic absorption spectrometric (AAS) method. The performance of the developed methods was assured as per ICH guidelines for analyzing the studied drugs in their pharmaceutical dosage form along with two of their official impurities. In addition, bioanalytical method validation was conducted where linearity was achieved at 2.0-40.0 µg mL-1, 2.0-40.0 µg mL-1 and 5.0-80.0 µg mL-1 for TET, MET and BSC, respectively.


Asunto(s)
Metronidazol , Impresión Molecular , Compuestos Organometálicos , Humanos , Cromatografía Líquida de Alta Presión/métodos , Espectrofotometría Atómica , Tetraciclina , Extracción en Fase Sólida/métodos , Preparaciones Farmacéuticas , Impresión Molecular/métodos , Adsorción
5.
Sci Rep ; 14(1): 2085, 2024 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267465

RESUMEN

Two different multivariate techniques have been applied for the quantitative analysis of caffeine, codeine, paracetamol and p-aminophenol (PAP) in quaternary mixture, namely, Partial Least Squares (PLS-1) and Artificial Neural Networks (ANN). For suitable analysis, a calibration set of 25 mixtures with various ratios of the drugs and PAP impurity were established using a 4-factor 5-level experimental design. The most meaningful wavelengths for the chemometric models were chosen using Genetic Algorithm (GA) as a variable selection technique. By using an independent validation set, the validity of the proposed methods was evaluated. A comparative study was established between the three multivariate models (PLS-1, GA-PLS and GA-ANN). The comparison between the various models revealed that the GA-ANN model was superior at resolving the highly overlapped spectra of this quaternary combination. The drugs were successfully quantified in their pharmaceutical dosage form utilizing the GA-ANN models.


Asunto(s)
Aminofenoles , Cafeína , Codeína , Acetaminofén , Quimiometría
6.
Sci Rep ; 13(1): 19678, 2023 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-37952008

RESUMEN

This work is concerned with exploiting the power of chemometrics in the assay and purity determination of naphazoline HCl (NZ) and pheniramine maleate (PN) in their combined eye drops. Partial least squares (PLS) and artificial neural network (ANN) were the chosen models for that purpose where three selected official impurities, namely; NZ impurity B and PN impurities A and B, were successfully determined. The quantitative determinations of studied components were assessed by percentage recoveries, standard errors of prediction as well as root mean square errors of prediction. The developed models were constructed in the ranges of 5.0-13.0 µg mL-1 for NZ, 10.0-60.0 µg mL-1 for PN, 1.0-5.0 µg mL-1 for NZ impurity B and 2.0-14.0 µg mL-1 for two PN impurities. The proposed models could determine NZ and PN with respective detection limits of 0.447 and 1.750 µg mL-1 for PLS, and 0.494 and 2.093 µg mL-1 for ANN. The two established models were compared favorably with official methods where no significant difference observed.


Asunto(s)
Nafazolina , Feniramina , Soluciones Oftálmicas , Quimiometría , Espectrofotometría/métodos , Análisis de los Mínimos Cuadrados
7.
BMC Chem ; 17(1): 140, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37876002

RESUMEN

The presence of minor components represents a challenging problem in spectrophotometric analysis of pharmaceuticals. If one component has a low absorptivity or present in a low concentration compared to the other components, this will hinder its quantitation by spectrophotometric methods. Continuous Wavelet Transform (CWT) as a signal processing technique was utilized to figure out a solution to such a problem. A comparative study was established between traditional derivative spectrophotometry (Numerical Differentiation, ND) and CWT to indicate the advantages and limitations of each technique and possibility of solving the problem of minor components. A mixture of ibuprofen (IBU) and phenylephrine (PHE) with its degradation products forming a ternary mixture was used for comparing the two techniques. The two techniques were applied on raw spectral data and on ratio spectra data resulting in four methods, namely ND, CWT, Derivative Ratio-Zero Crossing (DRZC) and Continuous Wavelet Transform Ratio-Zero Crossing (CWTR-ZC) methods. By comparing the results in laboratory prepared mixtures, CWT technique showed advantages in analysis of mixtures with minor components than ND. The proposed methods were validated according to the ICH guideline Q2(R1), where their linearity was established with correlation coefficient ranging from 0.9995 to 0.9999. The linearity was in the range 3-40 µg/mL for PHE in all methods, while for IBU it was 20-180 and 30-180 µg/mL in CWT and ND methods, respectively. The CWT methods were applied for quantitative determination of the drugs in their dosage form showing the ability of the methods to quantitate minor components in pharmaceutical formulations.

8.
BMC Chem ; 17(1): 141, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37876006

RESUMEN

The development and validation of the stability indicating HPLC technique has contributed to the understanding of the stability profile of ibuprofen (IBU) and phenylephrine (PHE). Stability profile was achieved for PHE; the drug was found to be liable to be influenced by stress oxidative conditions; two oxidative degradants (Deg1 & Deg2) were formed and their structures were confirmed using IR and mass spectrometry. The drugs and degradation products were successfully separated using a gradient elution method on YMC-C8 column with 0.1% hexanesulfonic acid and acetonitrile as a mobile phase at pH 6.6. The flow rate was 1.0 mL/min, and a diode array detector operating at 220 nm was used for UV detection. The retention times of degradants Deg1, Deg2, ibuprofen (IBU), and phenylephrine hydrochloride (PHE) were 2.0, 2.2, 3.2 and 7.0 min, respectively. The proposed method was validated with respect to linearity, accuracy, precision, specificity, and robustness using ICH guidelines. The linearities of ibuprofen and phenylephrine hydrochloride were in the range of 10-100 µg/mL and 0.3-10 µg/mL, respectively. The % recoveries of the two drugs were found to be 100.75 ± 1.44%, 99.67% ± 1.67, and the LOD was found to be 2.75/mL and 0.09/mL for IBU, and PHE, respectively. The method was successfully applied to the estimation of ibuprofen and phenylephrine hydrochloride combination in pharmaceutical dosage form. The proposed technique was validated using ICH guidelines and its greenness was assessed according to Analytical Eco Scale metric (AES). Molecular docking was used to assess the two drugs and PHE oxidative degradants interaction with the stationary phase and to confirm the outcomes of the proposed method with regard to the order of elution of the two drugs and PHE degradation products. Eco-friendly and environmental safety were assessed through the application of one of the most applicable greenness assessment tool; Analytical Eco Scale metric (AES).

9.
Anal Chim Acta ; 1278: 341707, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37709450

RESUMEN

BACKGROUND: An anti-H-pylori co-formulated mixture of tetracycline HCl (TET), metronidazole (MET), and bismuth subcitrate (BSC) is recently available. Only two chromatographic and spectrophotometric methods are reported for determining those drugs simultaneously where the effect of impurities that could be present as well as the biological fluids matrix influence do not be taken into consideration. There is a need to develop an easy-to-use potentiometric technique for analysis of TET, MET, and BSC in their co-formulated capsules, in presence of some official impurities and in spiked human plasma. RESULTS: Three carbon paste electrodes (CPEs) were fabricated for this purpose. Being a solid contact ion-selective electrode, CPE suffers from the creation of a water layer affecting its stability and reproducibility. Besides, it has a common problem in differentiation between two drugs carrying the same charge (positively charged TET and MET). Water layer formation was prevented through inserting polyaniline nanoparticles (≈10.0 nm diameter) between solid contact and ion-sensing membrane in the three proposed sensors. TET and MET interference was overcome by synthesizing a corresponding molecular imprinted polymer (MIP) for each drug. The synthesized MIPs were inserted in equivalent sensing membranes and characterized using several techniques. The suggested MIPs have a noticeable enhanced sensitivity in potentiometric determination. The obtained LODs were 5.88 × 10-8, 5.19 × 10-7, and 1.73 × 10-6 M for TET, MET and BSC proposed CPEs, respectively, with corresponding slopes of 57.37, 56.20, and -57.40 mV decade-1. SIGNIFICANCE: The proposed potentiometric method makes the detection of the three cited drugs simple, fast, and feasible. This approach is the first for determining three drugs potentiometrically in one combined formulation. The obtained results were compared favorably with previously reported potentiometric methods.


Asunto(s)
Carbono , Metronidazol , Humanos , Cápsulas , Reproducibilidad de los Resultados , Electrodos de Iones Selectos , Tetraciclinas
10.
BMC Chem ; 17(1): 76, 2023 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-37454105

RESUMEN

Two Chromatographic methods have been established and optimized for simultaneous determination of serdexmethylphenidate (SER.DMP) and dexmethylphenidate (DMP) in the presence of their degradation products. The first method is a reversed phase high performance liquid chromatography with diode array detection (HPLC-DAD). Isocratic separation was carried out on Waters X-bridge Shield RP18 column (150×3.9×5 µm particle size) using a mixture of 5 mM phosphate buffer (pH 5.5): acetonitrile (40:60, v/v) as a mobile phase, flow rate 1 mL/min and detection at 220 nm. The second method is a thin-layer chromatography (TLC)-densitometry method using methanol: chloroform (70:30, v/v) as a mobile phase and UV scanning at 220 nm. In HPLC method, the linearity range of SER.DMP was (2.5-25 µg/mL); with LOD (0.051 µg/mL) and LOQ (0.165 µg/mL) while for DMP was (2.5-25 µg/mL); with LOD and LOQ of (0.098 µg/mL) and (0.186 µg/mL), respectively. For TLC method the sensitivity range of SER.DMP was (5-25 µg/mL), LOD was (0.184 µg/spot), while LOQ was (0.202 µg/ spot) whereas for DMP the sensitivity range was (5-25 µg/mL) with LOD of (0.115 µg/ spot) and LOQ of (0.237 µg/ spot), respectively. SER.DMP was found to be equally labile to acidic and alkaline hydrolysis, whereas DMP was sensitive to acidic hydrolysis only. Both drugs were successfully determined in presence of acidic and basic degradants by the two developed methods (stability indicating assay method). Chromatographic separation of the degradation products was carried out on TLC aluminum silica plates 60 F254, as a stationary phase, using methanol: dichloroethane: acetonitrile (60:20:20 v/v), as a mobile phase. The degradation pathway was confirmed using TLC, IR, 1H-NMR and mass spectroscopy; moreover, the separation power was correlated to the computational results by applying molecular dynamic simulation. The developed methods were validated according to the International Conference on Harmonization (ICH) guidelines demonstrating good accuracy and precision. They were successfully applied for quantitation of SER.DMP and DMP in pure and capsule forms. The results were statistically compared with those obtained by the reported method in terms of accuracy, precision and robustness, and no significant difference was found.

11.
BMC Chem ; 17(1): 16, 2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36915195

RESUMEN

This work is dedicated to the greenness estimation of three proposed spectrophotometric techniques [e.g., ratio difference (RD), mean centering of ratio spectra (MCR) and continuous wavelet transform of ratio spectra (CWT)] for the determination of a binary combination named Ofloxacin (OFL) and Ornidazole (ORN). Applying the green analytical chemistry methods to assess the proposed methods has widely attained the analytical community care. The greenness assessment was performed via three evaluation approaches; the "Analytical Eco-Scale", the "National Environmental Method Index" (NEMI) and "Green Analytical Procedure Index" (GAPI). Following the examination of the zero spectrum of OFL and ORN, it is observed that OFL and ORN spectra are overlapped, so they can be detected by the methods mentioned previously. The ratio difference method was carried out at wavelengths of 294.6 nm and 265.6 nm for OFL, 292 nm and 315 nm for ORN. The linear range was (2-15 µg/mL) for OFL and (3-30 µg/mL) for ORN. The MCR method based on the use of mean centered ratio spectra in dual steps and calculating the second ratio spectra mean centered values at 294.6 nm for OFL and 315 nm for ORN. The continuous wavelet transformation which carried out using MATLAB at wavelengths of 265 nm for OFL and 306 for ORN. These techniques were intended for the binary mixture analysis in bulk powder and pharmaceutical formulations with high recoveries. The developed methods were validated according to ICH guidelines. All techniques were statistically compared to either an official method for OFL or a reported method for ORN and the results indicate that there were not any significant differences.

12.
BMC Chem ; 17(1): 24, 2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36949535

RESUMEN

A sequential spectrophotometric resolution technique (SSRT) was developed in this study without the use of systematic separation procedures to determine drug of a quaternary combination; caffeine (CAF), pseudoephedrine (PSE), doxylamine succinate (DOX), and paracetamol (PAR). Their presence in a tablet with a gap ratio of 3:3:1:150, respectively, and their overlapping spectra with low absorptivities make their resolution and determination impossible without prior separation. successive ratio subtraction technique (SRST) and constant multiplication method were used to solve these problems. Furthermore, an in-lab sample enrichment technique was applied to increase minor components concentration and consequently their absorbanses (CAF, PSE, and DOX). The D0 absorption spectra were generated by successive ratios followed by subtraction and multiplication of the constants. The maximum absorbances of the drugs tested, namely (CAF, PSE, DOX and PAR) were measured at wavelengths of 272.0, 257.0, 260.0, and 248.0 nm, respectively. The limits of detection (LOD) and limits of quantification (LOQ) were 0.021, 0.124, 0.186, 0.137 and 0.070, 0.414, 0.621, 0.456 (µg/mL), respectively. The linearitiy ranges (µg/mL) were 1.0-22.0, 1.0-24.0, 10.0-90.0 and 1.0-15.0 for CAF, PSE, DOX, and PAR, respectively. The International Conference on Harmonization (ICH) guidelines were applied for method validation, and the results obtained were within the limited parameters. The finding results were compared to official and/or published analytical methods to determine the procedure's reliability. It was noted that there was no actual difference in accuracy and precision between both meyhods. The proposed technique is sensitive, selective and economic;so it can be applied to the simultaneous analysis of these drugs in their commercial tablets and/or in quality-control laboratories.

13.
BMC Chem ; 16(1): 117, 2022 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-36529773

RESUMEN

Desmopressin acetate (DPA) is a synthetic analogue of vasopressin used in the treatment of diabetes insipidus, bedwetting, hemophilia A, and elevated levels of urea in the blood. Sensitive and selective stability-indicating methods are needed to be developed and validated for its assay pure and pharmaceutical dosage forms in the presence of its degradation products as no method has been reported for its determination in the presence of its degradants. This work describes a comparative study of five simple stability-indicating spectrophotometric techniques for determination of DPA in presence of its acid-degradation products (acid-degradants) without prior separation. The proposed spectrophotometric techniques (First derivative, Derivative ratio, Ratio difference, Mean centering and Dual wavelength) were developed and validated according to ICH guidelines. Acid degradation was carried out with 0.1 N HCl; the acid-degradants were separated on TLC plates and the acidic degradation pathway was established by IR, H-NMR and MS techniques. The TLC method was based on the separation of DPA and its acid-induced degradation products on silica gel plates using methanol: water (80:20, v/v) as a developing system and UV detection at 254 nm. All assay suggested methods were successfully applied for quantitation of DPA in pure and tablet forms. They are specific, sensitive, precise and accurate. They showed good linearity in the concentration range of 1-14 µg/mL with good correlation coefficients, and limit of detection (LOD) of 0.304, 0.274, 0.167, 0.248 and 0.199 and limit of quantitation (LOQ) of 0.920, 0.829, 0.506, 0.751 and 0.604) for each method, respectively. These methods were successfully applied for the simultaneous determination of DPA in its pure and tablet dosage form in the presence of its acid-degradants. The results obtained were statistically comparable with those of reported HPLC assay method; no significant differences were observed with relevance to accuracy and precision. All the methods are sensitive, selective and can be used for the routine analysis of DPA in its pure and dosage forms.

14.
BMC Chem ; 16(1): 24, 2022 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-35379288

RESUMEN

Impurity profiling of a pharmaceutical compound is now taking great attention during quality assessment of pharmaceuticals, as presence of small amount of impurities may affect safety and efficacy. In this work, a novel TLC chromatographic method coupled with densitometric detection was established for the simultaneous quantification of naphazoline HCl, pheniramine maleate and three of their official impurities, namely; naphazoline impurity B, pheniramine impurities; A & B. Chromatographic separation was carried out on TLC aluminum silica plates F254, as a stationary phase, using methanol: ethyl acetate: 33.0% ammonia (2.0: 8.0: 1.0, by volume), as a mobile phase. Plates were examined at 260.0 nm and International Council for Harmonisation (ICH) guidelines were followed for method's validation. Important factors, such as; composition of mobile phase and detection wavelengths were optimized. Linearity was achieved over the ranges of 2.0-50.0 µg band-1 for naphazoline, 10.0-110.0 µg band-1 for pheniramine, 0.1-10.0 µg band-1 for naphazoline impurity B and 2.0-50.0 µg band-1 for both pheniramine impurities. The proposed method was assessed in terms of accuracy, precision and robustness where satisfactory results (recovery % ≈ 100% and RSD < 2) were obtained. The method was also applied for the simultaneous determination of naphazoline HCl and pheniramine maleate, in Naphcon-A® eye drops, with respective recoveries of 101.36% and 100.94%. Method greenness was evaluated and compared to the reported HPLC one via environmental, health and safety tool. The developed method has much potential over the reported one of being simple, selective, economic and time saving for the analysis of the five cited compounds.

15.
Food Chem ; 382: 131702, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35149471

RESUMEN

In this paper, chemically modified carbon paste Mn2O3/MCNTs-NPs electrode for estimation of dinitolmide (DOM) utilizing square wave voltammetry method (SWV) was developed. The study investigated the electrochemical behavior of DOM, and the morphology of the modified electrode was evaluated by Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM). The voltammetric behavior of DOM at modified electrode was recorded at a scan rate of 100 mVs-1 against Ag/AgCl reference electrode in phosphate buffer pH 4.0 within linearity range 2-12 µM, LOQ, and LOD of 1.8 and 0.594 µM, respectively, with average % recovery of (100.89 ± 0.795). GAPI and Analytical Eco-Scale tools were applied for greenness assessment. Specificity and interference study was valid for the proposed method; allowing DOM to be determined in its acidic degradation and its major interference drug. The proposed method was successfully employed to quantify DOM in bulk powder, egg, and frozen cuts-up chicken muscle samples.


Asunto(s)
Carbono , Dinitolmida , Técnicas Electroquímicas , Electrodos , Productos Avícolas
16.
Spectrochim Acta A Mol Biomol Spectrosc ; 271: 120880, 2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35032731

RESUMEN

Six selective spectrophotometric techniques, four univariate and two multivariate ones were developed for the determination of the antidiabetic drug omarigliptin (OMR) along with its hydrolytic and oxidative degradation products. The proposed univariate spectrophotometric methods were ratio subtraction, first derivative, derivative ratio and ratio difference. Linearities were constructed in the range of 10.0-180.0 µg mL-1 for both OMR & its hydrolytic degradation product and 10.0-110.0 µg mL-1 for the oxidative degradation one. On the other hand, partial least squares and artificial neural networks were the chosen multivariate approaches. Their linearity ranges were 20.0-60.0 µg mL-1 for OMR and 10.0-30.0 µg mL-1 for the two degradation products. All the methods were validated, effectively applied for quantification of the intact drug in its tablet formulation and favorably compared to the reported one.


Asunto(s)
Compuestos Heterocíclicos con 2 Anillos , Análisis de los Mínimos Cuadrados , Piranos , Espectrofotometría/métodos
17.
J Chromatogr Sci ; 59(8): 762-769, 2021 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-33434917

RESUMEN

In a contribution to stability profiling of the recent antidiabetic drug, omarigliptin (OMR), two stability-indicating chromatographic methods were developed and validated. Stability profiling was performed for OMR under different stress conditions as acidic, alkaline, oxidative, photolytic and thermal degradations. Structures elucidation to all formed degradation products were identified using IR and mass spectrometry. Thin Layer Chromatography (TLC) and High-Performance Liquid Chromatography (HPLC) were used. In TLC-densitometric method, aluminum TLC plates precoated with silica gel G.F254 were used as stationary phase along with methanol: ethyl acetate: 33% ammonia (2:8:1,v/v/v) as mobile phase. The obtained chromatograms were scanned at 254 nm over concertation range of 5-70 µg band-1 for OMR. The second chromatographic method was an HPLC one with diode array detection and RP-C18 column with isocratic elution. Mobile phase used was composed of phosphate buffer pH 3.5: acetonitrile (80, 20, v/v), delivered at flow rate of 1.0 mL min-1. Diode array detector was adjusted at 230 nm with linearity range of 15-180 µg mL-1 for OMR. Several factors affecting TLC and HPLC efficiency have been carefully studied. The developed methods were validated according to International Conference on Harmonization guidelines and successfully applied for assessment of OMR in bulk powder and tablets.


Asunto(s)
Compuestos Heterocíclicos con 2 Anillos , Hipoglucemiantes , Cromatografía Líquida de Alta Presión , Cromatografía en Capa Delgada , Estabilidad de Medicamentos , Piranos , Reproducibilidad de los Resultados
18.
RSC Adv ; 11(12): 7051-7058, 2021 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-35423192

RESUMEN

A simple RP-HPLC-DAD method was developed and validated, as per the ICH guidelines, for simultaneous determination of naphazoline HCl (NPZ) & pheniramine maleate (PHN) along with three of their official impurities. Chromatographic separation was performed on a hypersil ODS column (5 mm, 250-4.6 mm i.d.) with isocratic elution using phosphate buffer pH 6.0: acetonitrile (70 : 30, v/v) as mobile phase, at a flow rate of 1.0 mL min-1 and UV detection at 260.0 nm. The developed method was found to be linear over the concentration ranges of 5.00-45.00 µg mL-1 for NPZ and NPZ impurity B and 10.00-110.00 µg mL-1, 10-70 µg mL-1 and 10-120 µg mL-1 for PHN, and PHN impurity A and B, respectively, with correlation coefficient values <0.999 for the five cited compounds. The method was confirmed to be accurate, robust and precise with RSD >2.0%. LOD and LOQ values for the five cited compounds were calculated. Moreover, the method was also validated in rabbit aqueous humor as per the US food and drug administration (FDA) bioanalytical validation guidelines. Finally, the proposed method was applied for the analysis of the two drugs along with their impurities in dosage form and spiked aqueous humor samples.

19.
RSC Adv ; 11(22): 13366-13375, 2021 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-35423846

RESUMEN

Over past years, the field of pharmaceutical dissolution testing has significantly expanded to cover not only the quality control of dosage forms, but also to play an important role in the bioavailability testing paradigm and screening of most formulations. These tests usually need a very long time sampling and monitoring, so that the automation of sampling is laborsaving. Problems often occur with these automatic devices due to sampling lines that may disconnect, crimp, carry over, become mixed up, or are inadequately cleaned. Potentiometric sensors, such as liquid contact (LC-ISE) or solid contact ion-selective electrodes (SC-SP-ISE), can provide timely data to be used for the real-time tracking of the amount of active pharmaceutical ingredients (APIs) released in the dissolution medium without these problems. In this work, we adopted the Just-Dip-It approach as a process analytical technology solution with the ultimate goal of advancing the ion selective sensors to their most effective use in pharmaceutical analysis. Two sensors were fabricated, the traditional LC-ISE and SC-SP-ISE. The sensing poly-vinyl chloride membranes of two electrodes were prepared using 2-nitrophenyl octyl ether as a plasticizer to soften the membrane, and the reduction in resistance to pioglitazone ions (PIO) permeability was achieved through the incorporation of sodium tetraphenylborate and calix[8]arene as a cationic exchanger salt and inclusion complexing ligand, respectively. Finally, prepared membranes were turned into the flexible perm-selective slices of hydrophobic plastic, which work as a barrier to other compounds, except for the PIO cation in the concentration range of 1 × 10-6 to 1 × 10-2 M and 1 × 10-5 to 1 × 10-2 M for SC-SP-ISE and LC-ISE, respectively. The challenges and opportunities of both sensors in comparison to a developed HPLC method were discussed for the dissolution testing of the combination dosage forms of pioglitazone. Potentiometric methods were validated according to IUPAC guidelines, while HPLC was validated according to ICH guidelines to ensure accuracy and precision.

20.
RSC Adv ; 11(31): 19196-19202, 2021 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-35478607

RESUMEN

Thin layer chromatography (TLC) is a powerful and simple technique for screening and quantifying low quality and counterfeit pharmaceutical products. The detection methods used to detect and quantify separate analytes in TLC ranges from the densitometric method to mass spectrometric or Raman spectroscopic methods. This work describes the development and optimization of a simple and sensitive TLC method utilizing a smartphone CCD camera for verification of both identity and quantity of antibiotics in dosage form, namely ofloxacin and ornidazole. Mixtures of ofloxacin and ornidazole were chromatographed on a silica gel 60 F254 plate as a stationary phase. The optimized mobile phase is n-butanol : methanol : ammonia (8 : 1 : 1.5 by volume). Iodine vapor has been used as a "universal stain" to visualize the spots on the TLC plates in order to obtain a visual image using the smartphone camera and a desk lamp as an illumination source, thus eliminating the need for a UV illumination source. The recorded images were processed to calculate the R f values (R f values for ofloxacin and ornidazole were 0.12 and 0.76, respectively) which provide identity of the drugs while spot intensity was calculated using a commercially available smartphone app and employed for quantitative analysis of the antibiotics and "acetaminophen" as an example of a counterfeit substance. The smartphone TLC method yielded a linearity of ofloxacin and ornidazole in the range of 12.5-62.5 µg/band and 500-1000 µg/band, respectively. The limit of detection was found to be 1.6 µg/spot for ofloxacin and 97.8 µg/spot for ornidazole. The proposed method was compared with the bench top densitometric method for verification using a Camag TLC Scanner 3, the spot areas were scanned at 320 nm. The R f value of ofloxacin and ornidazole was calculated to be 0.12 and 0.76, respectively. The densitometric method yielded a linearity of ofloxacin and ornidazole in the range of 5-40 µg/band and 5-50 µg/band, respectively. The limit of detection was found to be 0.8 µg/spot for ofloxacin and 1.1 µg/spot for ornidazole. The proposed method has been successfully applied for the determination of ofloxacin and ornidazole present in more than one pharmaceutical dosage form and was comparable to the densitometric method.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA