Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
World J Urol ; 42(1): 310, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38722553

RESUMEN

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Urólogos , Humanos , Urología , Procedimientos Quirúrgicos Urológicos
2.
World J Urol ; 42(1): 298, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709327

RESUMEN

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Asunto(s)
Diseño de Equipo , Riñón , Iluminación , Ureteroscopios , Modelos Anatómicos , Humanos
3.
World J Urol ; 42(1): 277, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38691160

RESUMEN

PURPOSE: To prospectively evaluate the rate and associated risk factors of early infectious complications after ureterorenoscopy for urolithiasis. METHODS: After ethical committee approval, 400 therapeutic retrograde ureterorenoscopy procedures between August 3, 2020 and November 24, 2021 were included for analysis in a single-center study. Postoperative infection was defined as an afebrile urinary tract infection, fever (≥ 38 °C) with pyuria (≥ 300 WBC/µL) or proven urinary pathogen, and urosepsis. The primary outcome was the rate of infectious complications after ureterorenoscopy. Secondary outcomes were the perioperative factors that increased the risk of infectious complications within 30 days of surgery using univariate and multivariate logistic regression analysis. RESULTS: Twenty-nine of four hundred (7.3%) patients developed an infectious complication within 30 days after ureterorenoscopy. Ten (2.5%) patients developed an afebrile urinary tract infection, eight (2.0%) developed fever with pyuria, five (1.3%) febrile urinary tract infection, and six (1.5%) urosepsis. On univariate analysis, preoperative stent-type JFil® pigtail suture stent was significantly associated with the dependent variable (p < 0.001). On multivariate logistic regression analysis, older age (OR 1.035; 95% CI 1.006-1.070; p = 0.02) was found to be significantly associated with developing a postoperative infectious complication. CONCLUSIONS: A 7.3% rate of postoperative infectious complications and 1.5% urosepsis rate were observed after therapeutic ureterorenoscopy, without the need of intensive care admission. The only significant risk factors were preoperative stent type (JFil® pigtail suture stent) on univariate analysis, and older age on multivariate logistic regression analysis. Further multicentric prospective observational data are needed in this field.


Asunto(s)
Complicaciones Posoperatorias , Ureteroscopía , Infecciones Urinarias , Humanos , Masculino , Femenino , Estudios Prospectivos , Factores de Riesgo , Ureteroscopía/efectos adversos , Persona de Mediana Edad , Infecciones Urinarias/epidemiología , Infecciones Urinarias/etiología , Adulto , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Factores de Tiempo , Sepsis/etiología , Sepsis/epidemiología , Urolitiasis/cirugía
4.
World J Urol ; 42(1): 355, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38796790

RESUMEN

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Asunto(s)
Diseño de Equipo , Iluminación , Ureteroscopios , Ureteroscopía , Luz , Humanos , Solución Salina , Color
5.
World J Urol ; 42(1): 294, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38704777

RESUMEN

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Asunto(s)
Ureteroscopios , Ureteroscopía , Humanos , Diseño de Equipo , Iluminación , Docilidad , Cálices Renales
6.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38488927

RESUMEN

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Protección Radiológica , Humanos , Estudios Prospectivos , Exposición Profesional/prevención & control , Fluoroscopía/efectos adversos , Exposición a la Radiación/prevención & control , Dosis de Radiación
7.
J Endourol ; 38(5): 488-498, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38429915

RESUMEN

Urothelial carcinoma (UC) affecting the urinary tract is recognized as one of the prevalent types of cancer, ranking fifth in terms of incidence. However, it is important to note that upper tract urothelial carcinoma (UTUC), in comparison to bladder cancer, is relatively uncommon and represents a minority of UC cases, accounting for ∼5% to 10%. It is worth emphasizing that as much as 60% of UTUC cases are invasive at the time of diagnosis, in contrast to 25% of bladder cancer cases. These statistics highlight the urgent need for well-designed, multidisciplinary strategies to guide optimal management for this vulnerable patient population, aiming to control treatment variability and minimize the risks associated with undertreatment and overtreatment. Methods: In this study, we present a comparative analysis of the contemporary guidelines on UTUC management from the European Association of Urology (EAU) and the American Urological Association/Society of Urologic Oncology (AUA/SUO) released in 2023. Our objective is to contrast the different guidelines and examine the evidence on which their recommendations are based. Results: By thoroughly reviewing the guidelines from both organizations, we observed substantial agreement on the management of UTUC. However, we also identified noticeable differences among these guidelines, leading to a wide range of recommendations. These disparities might stem from variations in clinical practices, regional preferences, and the availability of resources. It is crucial to acknowledge that both the EAU and AUA/SUO base their guidelines on the latest scientific evidence and expert consensus within their respective regions. Conclusions: These findings underscore the importance of ongoing collaboration, knowledge exchange, and harmonization of guidelines to improve the standard of care for UTUC globally. Future research should focus on identifying areas of consensus and bridging the gaps between different international guidelines to enhance the management outcomes for this challenging disease.


Asunto(s)
Guías de Práctica Clínica como Asunto , Humanos , Europa (Continente) , Estados Unidos , Carcinoma de Células Transicionales/terapia , Carcinoma de Células Transicionales/diagnóstico , Carcinoma de Células Transicionales/patología , Neoplasias Urológicas/terapia
8.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520528

RESUMEN

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Asunto(s)
Iluminación , Ureteroscopios , Humanos , Diseño de Equipo , Urólogos , Equipos Desechables , Ureteroscopía
10.
BMC Urol ; 24(1): 24, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38287319

RESUMEN

INTRODUCTION: Extended pelvic lymph node dissection (ePLND) in men undergoing robot-assisted laparoscopic radical prostatectomy (RARP) is a widely used procedure. However, little is known about anatomical site-specific yields and subsequent metastatic patterns in these patients. PATIENTS AND METHODS: Data on a consecutive series of 1107 patients undergoing RARP at our centre between 2004 and 2018 were analysed. In men undergoing LN dissection, the internal, external and obturator nodes were removed and sent in separately. We performed an analysis of LN yields in total and for each anatomical zone, patterns of LN metastases and complications. Oncological outcome in pN+ disease was assessed including postoperative PSA persistence and survival. RESULTS: A total of 823 ePLNDs were performed in the investigated cohort resulting in 98 men being diagnosed as pN+ (8.9%). The median (IQR) LN yield was 19 (14-25), 10 (7-13) on the right and 9 (6-12) on the left side (P < 0.001). A median of six (4-8) LNs were retrieved from the external, three (1-6) from the internal iliac artery, and eight (6-12) from the obturator fossa. More men had metastatic LNs on the right side compared to the left (41 vs. 19). Symptomatic lymphoceles occurred exclusively in the ePLND group (2.3% vs. 0%, p = 0.04). Postoperatively, 47 (47.9%) of men with pN+ reached a PSA of < 0.1µg/ml. There was no association between a certain pN+ region and postoperative PSA persistence or BCRFS. The estimated cancer specific survival rate at 5 years was 98.5% for pN+ disease. CONCLUSION: Robot-assisted laparoscopic ePLND with a high LN yield and low complication rate is feasible. However, we observed an imbalance in more removed and positive LNs on the right side compared to the left. A high rate of postoperative PSA persistence and early recurrence in pN+ patients might indicate a possibly limited therapeutical value of the procedure in already spread disease. Yet, these men demonstrated an excellent survival.


Asunto(s)
Laparoscopía , Neoplasias de la Próstata , Robótica , Masculino , Humanos , Antígeno Prostático Específico , Metástasis Linfática , Escisión del Ganglio Linfático/métodos , Neoplasias de la Próstata/patología , Ganglios Linfáticos/patología , Pelvis/patología , Prostatectomía/métodos , Laparoscopía/métodos
11.
World J Urol ; 42(1): 33, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38217743

RESUMEN

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Asunto(s)
Aluminio , Láseres de Estado Sólido , Litotripsia por Láser , Urolitiasis , Itrio , Humanos , Tulio , Urolitiasis/cirugía , Litotripsia por Láser/métodos , Láseres de Estado Sólido/uso terapéutico , Tecnología , Holmio
12.
World J Urol ; 42(1): 46, 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38244083

RESUMEN

PURPOSE: Urolithiasis has become increasingly prevalent, leading to higher disability-adjusted life years and deaths. Various stone classification systems have been developed to enhance the understanding of lithogenesis, aid urologists in treatment decisions, and predict recurrence risk. The aim of this manuscript is to provide an overview of different stone classification criteria. METHODS: Two authors conducted a review of literature on studies relating to the classification of urolithiasis. A narrative synthesis for analysis of the studies was used. RESULTS: Stones can be categorized based on anatomical position, size, medical imaging features, risk of recurrence, etiology, composition, and morphoconstitutional analysis. The first three mentioned offer a straightforward approach to stone classification, directly influencing treatment recommendations. With the routine use of CT imaging before treatment, precise details like anatomical location, stone dimensions, and Hounsfield Units can be easily determined, aiding treatment planning. In contrast, classifying stones based on risk of recurrence and etiology is more complex due to dependencies on multiple variables, including stone composition and morphology. A classification system based on morphoconstitutional analysis, which combines morphological stone appearance and chemical composition, has demonstrated its value. It allows for the rapid identification of crystalline phase principles, the detection of crystalline conversion processes, the determination of etiopathogenesis, the recognition of lithogenic processes, the assessment of crystal formation speed, related recurrence rates, and guidance for selecting appropriate treatment modalities. CONCLUSIONS: Recognizing that no single classification system can comprehensively cover all aspects, the integration of all classification approaches is essential for tailoring urolithiasis patient-specific management.


Asunto(s)
Litotricia , Urolitiasis , Humanos , Urolitiasis/terapia , Diagnóstico por Imagen , Litotricia/métodos , Urólogos
14.
Eur Urol Focus ; 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37940392

RESUMEN

CONTEXT: Laser performance for lithotripsy is currently reported using units of measurement such as J/mm3, mm3/J, mm3/s, s/mm3, and mm3/min. However, there are no current standardized definitions or terminology for these metrics. This may lead to confusion when assessing and comparing different laser systems. OBJECTIVE: The primary objective was to summarize outcome values and corresponding terminology from studies on laser lithotripsy performance using stone volume in relation to time or energy. The secondary objective was to propose a standardized terminology for reporting laser performance metrics. EVIDENCE ACQUISITION: A systematic review of the literature was conducted using the search string ("j*/mm3" OR "mm3/j*" OR "mm3/s*" OR "s*/mm3" OR "mm3/min*" OR "min*/mm3" AND "lithotripsy") on Scopus, Web of Science, Embase, and PubMed databases. Study selection, data extraction, and quality assessment were performed independently by two authors. EVIDENCE SYNTHESIS: A total of 28 studies were included, covering holmium:yttrium-aluminum-garnet (Ho:YAG), MOSES, and thulium fiber laser (TFL) technologies. Laser energy consumption values reported for the studies ranged from 2.0 - 43.5 J/mm3in vitro and from 2.7 - 47.8 J/mm3in vivo, translating to laser ablation efficiency of 0.023 - 0.500 mm3/J and 0.021 - 0.370 mm3/J, respectively. Laser ablation speeds ranged from 0.3 - 8.5 mm3/s in vivo, translating to lasing time consumption of 0.12 - 3.33 s/mm3. Laser efficacy ranged from 4.35 - 51.7 mm3/min in vivo. There was high heterogeneity for the terminology used to describe laser performance for the same metrics. CONCLUSIONS: The range of laser performance metric values relating stone volume to energy or time is wide, with corresponding differing terminology. We propose a standardized terminology for future studies on laser lithotripsy, including laser ablation efficiency (mm3/J), laser ablation speed (mm3/s), and laser energy consumption (J/mm3). Laser efficacy (mm3/min) is proposed as a broader term that is based on the total operative time, encompassing the whole technique using the laser. PATIENT SUMMARY: We reviewed studies to identify the units and terms used for laser performance when treating urinary stones. The review revealed a wide range of differing units, outcomes, and terms. Therefore, we propose a standardized terminology for future studies on laser stone treatment.

15.
Front Surg ; 10: 1274583, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37780913

RESUMEN

Ureteroscopy has become an increasingly popular surgical intervention for conditions such as urinary stone disease. As new technologies and techniques become available, debate regarding their proper use has risen. This includes the role of single use ureteroscopes, optimal laser for stone lithotripsy, basketing versus dusting, the impact of ureteral access sheath, the need for safety guidewire, fluoroscopy free URS, imaging and follow up practices are all areas which have generated a lot of debate. This review serves to evaluate each of these issues and provide a balanced conclusion to guide the clinician in their practice.

16.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37831156

RESUMEN

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Litotricia , Nefrolitiasis , Cálculos Urinarios , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Litotripsia por Láser/métodos , Cálculos Urinarios/terapia , Oxalato de Calcio , Holmio
17.
World J Urol ; 41(11): 3301-3308, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37682286

RESUMEN

INTRODUCTION: Several preclinical studies about a novel pulsed-thulium:yttrium-aluminum-garnet (p-Tm:YAG) device have been published, demonstrating its possible clinical relevance. METHODS: We systematically reviewed the reality and expectations for this new p-Tm:YAG technology. A PubMed, Scopus and Embase search were performed. All relevant studies and data identified in the bibliographic search were selected, categorized, and summarized. RESULTS: Tm:YAG is a solid state diode-pumped laser that emits at a wavelength of 2013 nm, in the infrared spectrum. Despite being close to the Ho:YAG emission wavelength (2120 nm), Tm:YAG is much closer to the water absorption peak and has higher absorption coefficient in liquid water. At present, there very few evaluations of the commercially available p-Tm:YAG devices. There is a lack of information on how the technical aspects, functionality and pulse mechanism can be maximized for clinical utility. Available preclinical studies suggest that p-Tm:YAG laser may potentially increase the ablated stone weight as compared to Ho:YAG under specific condition and similar laser parameters, showing lower retropulsion as well. Regarding laser safety, a preclinical study observed similar absolute temperature and cumulative equivalent minutes at 43° C as compared to Ho:YAG. Finally, laser-associated soft-tissue damage was assessed at histological level, showing similar extent of alterations due to coagulation and necrosis when compared with the other clinically relevant lasers. CONCLUSIONS: The p-Tm:YAG appears to be a potential alternative to the Ho:YAG and TFL according to these preliminary laboratory data. Due to its novelty, further studies are needed to broaden our understanding of its functioning and clinical applicability.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Temperatura , Agua , Holmio
18.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37587366

RESUMEN

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Cálculos Urinarios , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Polvo , Litotripsia por Láser/métodos , Cálculos Urinarios/terapia
19.
J Endourol ; 37(8): 935-939, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37337653

RESUMEN

Purpose: On February 6, 2018, the European Atomic Energy Community reduced the annual equivalent dose limit for the lens from 150 to 20 mSv/year, because of its association with cataracts at low radiation doses. Our aim was to estimate the radiation doses received by the lens during endourologic procedures that require fluoroscopy. Materials and Methods: Multicenter study including prospective data of annual eye dosimeters between 2017 and 2020. Four endourologists used an eye dosimeter in endourologic procedures that require fluoroscopy (ureteroscopy, retrograde intrarenal surgery, and percutaneous nephrolithotomy). Surgeons 1 and 2 wore leaded glasses; surgeon 1 also used the as low as reasonably achievable (ALARA) protocol. Descriptive statistical analysis using SPSS 25.0 was conducted. Results: Surgeons 1, 2, 3, and 4 performed a median of 159, 586, 102, and 129 endourologic procedures per year, respectively, for a total of 641, 2340, 413, and 350 procedures between 2017 and 2020. The median annual dose of lens radiation exposure was 0.16, 1.18, 3.79, and 1.42 mSv per year, respectively, which corresponds to 0.001, 0.009, 0.024, and 0.012 mSv per procedure. The two surgeons who used leaded glasses registered a lower radiation dose per procedure (0.001 vs 0.027). Similarly, the urologist who used the ALARA protocol registered the lowest lens radiation dose compared with the three surgeons who did not use it (0.001 vs 0.023). Conclusions: The endourologists who participated in this study effectively comply with current guidelines on radiation exposure to the lens. Registered eye lens radiation does not seem to be related to the number of procedures but rather to the use of leaded glasses and the ALARA protocol.


Asunto(s)
Cristalino , Exposición Profesional , Exposición a la Radiación , Humanos , Estudios Prospectivos , Dosis de Radiación , Fluoroscopía/efectos adversos , Estudios Multicéntricos como Asunto
20.
Ther Adv Urol ; 15: 17562872231179332, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37377944

RESUMEN

Objective: The objective of this study was to evaluate a new concept in flexible ureteroscopy: instrumental dead space (IDS). For this purpose, various proximal working channel connector designs, as well as the impact of ancillary devices occupying the working channel were evaluated in currently available flexible ureteroscopes. Design and methods: IDS was defined as the volume of saline irrigation needed to inject at the proximal connector for delivery at the distal working channel tip. Because IDS is related to working channel diameter and length, proximal connector design, as well as occupation of working channel by ancillary devices, these parameters were also reviewed. Results: IDS significantly varied between flexible ureteroscope models, ranging from 1.1 ml for the Pusen bare scopes, to 2.3 ml for Olympus scopes with their 4-way connector (p < 0.001). Proximal connector designs showed a high degree of variability in the number of available Luer locks, valves, seals, angles, and rotative characteristics. The measured length of the working channel of bare scopes ranged between 739 and 854 mm and significantly correlated with measured IDS (R2 = 0.82, p < 0.001). The coupling of scopes with an alternative ancillary proximal connector and the insertion of ancillary devices into the working channel significantly reduced IDS (mean IDS reduction of 0.1 to 0.5 ml; p < 0.001). Conclusions: IDS appears as a new parameter that should be considered for future applications of flexible ureteroscopes. A low IDS seems desirable for several clinical applications. The main factors impacting IDS are working channel and proximal connector design, as well as ancillary devices inserted into the working channel. Future studies should clarify how reducing IDS may affect irrigation flow, intrarenal pressure, and direct in-scope suction, as well as evaluate the most desirable proximal connector design properties.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...