Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Bone Joint J ; 99-B(11): 1520-1525, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29092993

RESUMEN

AIMS: To evaluate the effect of a single early high-dose vitamin D supplement on fracture union in patients with hypovitaminosis D and a long bone fracture. PATIENTS AND METHODS: Between July 2011 and August 2013, 113 adults with a long bone fracture were enrolled in a prospective randomised double-blind placebo-controlled trial. Their serum vitamin D levels were measured and a total of 100 patients were found to be vitamin D deficient (< 20 ng/ml) or insufficient (< 30 ng/mL). These were then randomised to receive a single dose of vitamin D3 orally (100 000 IU) within two weeks of injury (treatment group, n = 50) or a placebo (control group, n = 50). We recorded patient demographics, fracture location and treatment, vitamin D level, time to fracture union and complications, including vitamin D toxicity. Outcomes included union, nonunion or complication requiring an early, unplanned secondary procedure. Patients without an outcome at 15 months and no scheduled follow-up were considered lost to follow-up. The t-test and cross tabulations verified the adequacy of randomisation. An intention-to-treat analysis was carried out. RESULTS: In all, 100 (89%) patients had hypovitaminosis D. Both treatment and control groups had similar demographics and injury characteristics. The initial median vitamin D levels were 16 ng/mL (interquartile range 5 to 28) in both groups (p = 0.885). A total of 14 patients were lost to follow-up (seven from each group), two had fixation failure (one in each group) and one control group patient developed an infection. Overall, the nonunion rate was 4% (two per group). No patient showed signs of clinical toxicity from their supplement. CONCLUSIONS: Despite finding a high level of hypovitaminosis D, the rate of union was high and independent of supplementation with vitamin D3. Cite this article: Bone Joint J 2017;99-B:1520-5.


Asunto(s)
Colecalciferol/uso terapéutico , Fijación de Fractura , Fracturas Óseas/cirugía , Fracturas no Consolidadas/prevención & control , Deficiencia de Vitamina D/tratamiento farmacológico , Vitaminas/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Método Doble Ciego , Esquema de Medicación , Femenino , Estudios de Seguimiento , Fracturas Óseas/complicaciones , Fracturas no Consolidadas/epidemiología , Fracturas no Consolidadas/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Deficiencia de Vitamina D/complicaciones , Deficiencia de Vitamina D/diagnóstico
2.
Bone Joint J ; 96-B(11): 1535-9, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25371470

RESUMEN

The purpose of this study was to describe the radiological characteristics of a previously unreported finding: posterior iliac offset at the sacroiliac joint and to assess its association with pelvic instability as measured by initial displacement and early implant loosening or failure. Radiographs from 42 consecutive patients with a mean age of 42 years (18 to 77; 38 men, four women) and mean follow-up of 38 months (3 to 96) with Anteroposterior Compression II injuries, were retrospectively reviewed. Standardised measurements were recorded for the extent of any diastasis of the pubic symphysis, widening of the sacroiliac joint, static vertical ramus offset and a novel measurement (posterior offset of the ilium at the sacroiliac joint identified on axial CT scan). Pelvic fractures with posterior iliac offset exhibited greater levels of initial displacement of the anterior pelvis (anterior sacroiliac widening, pubic symphysis diastasis and static vertical ramus offset, p < 0.001,0.034 and 0.028, respectively). Pelvic fractures with posterior ilium offset also demonstrated higher rates of implant loosening regardless of fixation method (p = 0.05). Posterior offset of the ilium was found to be a reliable and reproducible measurement with substantial inter-observer agreement (kappa = 0.70). Posterior offset of the ilium on axial CT scan is associated with greater levels of initial pelvic displacement and early implant loosening.


Asunto(s)
Fracturas Óseas/complicaciones , Inestabilidad de la Articulación/diagnóstico por imagen , Imagen por Resonancia Magnética , Articulación Sacroiliaca/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Humanos , Inestabilidad de la Articulación/etiología , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Articulación Sacroiliaca/lesiones , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA