Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 38(7 Suppl 2): S3-S8, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36639116

RESUMEN

BACKGROUND: Mobile-bearing (MB) total knee arthroplasty (TKA) may reduce wear and improve patellar tracking but may increase revision risk due to tibial component design, balance complexity, and bearing dislocation. We utilized the American Joint Replacement Registry to examine risk of revision with MB compared to fixed-bearing (FB) designs. METHODS: An analysis of primary TKA in patients over 65 years was performed with American Joint Replacement Registry data linked to Centers for Medicare and Medicaid Services data from 2012 to 2019. Analyses compared MB to FB designs with a subanalysis of implants from a single company. We identified 485,024 TKAs, with 452,199 (93.2%) FB-TKAs and 32,825 (6.8%) MB-TKAs. Cox proportional hazards regression modeling was used for all-cause revision and revision for infection, adjusting for sex, age, and competing risk of mortality. Event-free survival curves evaluated time to all-cause revision and revision for infection. RESULTS: MB-TKAs were at an increased risk for all-cause revision: hazard ratio (HR) 1.36 ([95% confidence interval (CI) 1.24-1.49], P < .0001) but not revision for infection: HR 1.06 ([95% CI 0.90-1.25], P = .52). When comparing implants within a single company, MB-TKAs were at an increased risk of all-cause revision: HR 1.55 ([95% CI 1.38-1.73], P < .0001). Event-free survival curves demonstrated increased risk for all-cause revision for MB-TKA across all time points, with a greater magnitude of risk up to 8 years. CONCLUSION: Although survivorship of both designs was outstanding, MB-TKA designs demonstrated increased risk for all-cause revision. Additional investigation is needed to determine if this is related to patient selection factors, surgical technique, bearing, or implant design.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Distinciones y Premios , Prótesis de la Rodilla , Anciano , Humanos , Estados Unidos/epidemiología , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/efectos adversos , Reoperación , Diseño de Prótesis , Medicare , Sistema de Registros , Articulación de la Rodilla/cirugía , Falla de Prótesis , Resultado del Tratamiento
2.
Clin Orthop Relat Res ; 480(10): 1929-1936, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35994277

RESUMEN

BACKGROUND: Highly cross-linked polyethylene (HXLPE) can improve wear properties in TKA, but it can also lead to decreased mechanical properties. Antioxidants were added to HXLPE to improve its mechanical properties while retaining the improved wear characteristics. However, it remains unclear whether these modifications to conventional polytheylene used in TKA have resulted in a change in the revision risk. QUESTIONS/PURPOSES: We used American Joint Replacement Registry data to ask: (1) Is there a difference in all-cause revision in patients who underwent TKA using HXLPE with or without an antioxidant doping compared with conventional polyethylene? (2) Is there a difference in revision for aseptic failure in patients who underwent TKA using HXLPE with or without an antioxidant doping compared with conventional polyethylene? METHODS: We analyzed American Joint Replacement Registry data from 2012 to 2019. We identified 339,366 primary TKAs over the study period in patients older than 65 years and linked procedures to supplemental Centers for Medicare & Medicaid data where available. Patient total number of reported comorbidities, gender, age, region, polyethylene characteristics, procedure dates, and indication for revision were recorded. Median follow-up was 34 months. We compared HXLPE with or without antioxidants to conventional polyethylene. Event-free percent survival curves and Cox proportional hazard regression modeling was used for all-cause revision and revision for aseptic failure. RESULTS: Compared with conventional polyethylene, there was no difference in all-cause revision with HXLPE with an antioxidant (HR 1.06 [95% CI 0.98 to 1.14]; p = 0.13) or HXLPE without an antioxidant (HR 1.04 [95% CI 0.97 to 1.11]; p = 0.28). Compared with conventional polyethylene, there was no difference in revision for aseptic failure with HXLPE with an antioxidant (HR 1.07 [95% CI 0.99 to 1.14]; p = 0.08) or HXLPE without an antioxidant (HR 1.03 [95% CI 0.97 to 1.01]; p = 0.30). CONCLUSION: We found no difference in revision risk between HXLPE with or without an antioxidant and conventional polyethylene during this time frame. HXLPE polyethylene, with or without an antioxidant, should not be widely adopted until or unless it is shown to be superior to conventional polyethylene in TKA. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Anciano , Antioxidantes , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Medicare , Polietileno , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Estados Unidos
3.
J Bone Joint Surg Am ; 104(17): 1548-1553, 2022 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-35726886

RESUMEN

BACKGROUND: Polyethylene bearing design may influence the risk of revision after total knee arthroplasty (TKA). Previous investigations from outside of the United States have suggested the potential for an increased risk of all-cause revision and revision for infection with the use of posterior-stabilized bearings. We examine the risk of revision based on the polyethylene bearing design selection for primary TKA. METHODS: An analysis of the American Joint Replacement Registry (AJRR) data from 2012 to 2019 was performed. We identified all primary TKAs over the study period and linked cases to supplemental U.S. Centers for Medicare & Medicaid Services (CMS) data where available. Patient demographic characteristics, polyethylene characteristics, procedure dates, and cause for revision were recorded. Analysis was performed to compare minimally stabilized implants (cruciate-retaining, anterior-stabilized, or pivot bearing designs) with posterior-stabilized implants. Cumulative incidence function (CIF) curves and Cox proportional hazard ratios (HRs) were created for all-cause revision and revision for infection in each group. RESULTS: We identified 305,279 cases with reported minimally stabilized or posterior-stabilized implant characteristics. There were 161,486 cases (52.9%) that utilized posterior-stabilized bearings compared with 143,793 cases (47.1%) with minimally stabilized bearings. For minimally stabilized bearings, 1,693 cases (1.18%) had all-cause revision and 334 cases (0.23%) had revision for infection. For posterior-stabilized bearings, 2,406 cases (1.49%) had all-cause revision and 446 cases (0.28%) had revision for infection. The use of posterior-stabilized bearings had HRs of 1.25 (95% confidence interval [CI], 1.2 to 1.3; p < 0.0001) for all-cause revision and 1.18 (95% CI, 1.0 to 1.4; p = 0.02) for revision for infection. CONCLUSIONS: Similar to investigations from international registries, we found an increased risk of all-cause revision and revision for infection when using posterior-stabilized bearings in TKA in the United States. Surgeons should consider this finding when considering bearing selection for primary TKA. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Medicare , Polietileno , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Estados Unidos
4.
J Arthroplasty ; 37(4): 659-667, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34826567

RESUMEN

BACKGROUND: Advances in polyethylene bearing characteristics have led to various options for total knee arthroplasty. We examine trends in use of polyethylene in the United States. METHODS: An analysis of American Joint Replacement Registry data from 2012 to 2019 for primary total knee arthroplasty procedures was conducted. Design and manufacturing characteristics were obtained and validated in the American Joint Replacement Registry dataset. Polyethylene bearing design and manufacturing use characteristics were compared by year, gender, age group, and geographic region of the procedure. Descriptive analysis was performed. RESULTS: We identified 993,292 cases over the study period. In total, 791,233 (80%) cases had complete device data available and were included in analysis. In addition, 366,280 (49.4%) cases utilized minimally stabilized bearings compared to 374,809 (50.6%) for posterior-stabilized bearings. Posterior-stabilized use was stable over the study period and highest in the Northeast (64.5%; P < .0001). Cruciate-retaining use decreased from 29.7% to 20.2% and anterior-stabilized use increased from 17.4% to 25.2%. Conventional polyethylene use decreased from 42.8% to 21.9%, and was highest in the 81+ age group (37.8%; P < .0001) and Northeast (43.0%; P < .0001). Highly cross-linked polyethylene (HXLPE) with antioxidant use increased from 9.08% to 31.8%, while HXLPE without antioxidant use remained constant. CONCLUSION: There was an increase in use of anterior-stabilized and pivot bearings and an increase in use of HXLPE with antioxidant. Additionally, there were noted age group and regional differences in the use of various bearings. Further study should evaluate if these changing utilization trends are related to clinical outcomes, or due to regional training, preferences, or manufacturer pressures. LEVEL OF EVIDENCE: Level III, retrospective.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Antioxidantes , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/cirugía , Polietileno , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Estudios Retrospectivos , Estados Unidos
5.
Arthroplast Today ; 9: 73-77, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34041333

RESUMEN

BACKGROUND: In 2014, the Affordable Care Act Hospital Readmissions Reduction Program began penalizing hospitals for excessive readmission rates 30 days after total hip arthroplasty (THA) and total knee arthroplasty (TKA). Various data sets with nonstandardized validation processes report readmission data, which may provide conflicting outcome values for the same patient populations. METHODS: We queried 4 separate data sets: the American Joint Replacement Registry, Centers for Medicare and Medicaid Services billing data, the Vizient data set, and an advanced analytics integration (Cognos) report from our electronic medical record. We identified 2763 patients who underwent primary TKA and THA at a single academic medical center from June 2016 to June 2019. We then matched 613 surgery encounters in all 4 databases. Our primary outcome metric was 30-day readmissions. Fleiss' Kappa was used to measure agreement among the different data sets. RESULTS: Of the 613 THA and TKA patients, there were 45 (7.3%) readmissions noted. Data collected from the Centers for Medicare and Medicaid Services flagged 41 (6.7%) readmissions, Vizient flagged 11 (1.8%) readmissions, and the American Joint Replacement Registry and Cognos report both flagged 6 (0.98%) readmissions each. None of the readmissions were identified by all 4 data sets. There was significant disagreement among data sets using Fleiss' Kappa (kappa = -0.1318, P = .03). CONCLUSION: There is disagreement in readmission rates in databases receiving the same patient data after THA and TKA. Care must be taken to establish standard validation processes and reporting methods and scrutiny applied when interpreting readmission rates from various data sets.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...