Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 10(1): 4980, 2019 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-31672971

RESUMEN

Understanding and controlling modal coupling in micro/nanomechanical devices is integral to the design of high-accuracy timing references and inertial sensors. However, insight into specific physical mechanisms underlying modal coupling, and the ability to tune such interactions is limited. Here, we demonstrate that tuneable mode coupling can be achieved in capacitive microelectromechanical devices with dynamic electrostatic fields enabling strong coupling between otherwise uncoupled modes. A vacuum-sealed microelectromechanical silicon ring resonator is employed in this work, with relevance to the gyroscopic lateral modes of vibration. It is shown that a parametric pumping scheme can be implemented through capacitive electrodes surrounding the device that allows for the mode coupling strength to be dynamically tuned, as well as allowing greater flexibility in the control of the coupling stiffness. Electrostatic pump based sideband coupling is demonstrated, and compared to conventional strain-mediated sideband operations. Electrostatic coupling is shown to be very efficient, enabling strong, tunable dynamical coupling.

2.
J Acoust Soc Am ; 146(1): 516, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31370610

RESUMEN

Ultra-high-speed video microscopy and numerical modeling were used to assess the dynamics of microbubbles at the surface of urinary stones. Lipid-shell microbubbles designed to accumulate on stone surfaces were driven by bursts of ultrasound in the sub-MHz range with pressure amplitudes on the order of 1 MPa. Microbubbles were observed to undergo repeated cycles of expansion and violent collapse. At maximum expansion, the microbubbles' cross-section resembled an ellipse truncated by the stone. Approximating the bubble shape as an oblate spheroid, this study modeled the collapse by solving the multicomponent Euler equations with a two-dimensional-axisymmetric code with adaptive mesh refinement for fine resolution of the gas-liquid interface. Modeled bubble collapse and high-speed video microscopy showed a distinctive circumferential pinching during the collapse. In the numerical model, this pinching was associated with bidirectional microjetting normal to the rigid surface and toroidal collapse of the bubble. Modeled pressure spikes had amplitudes two-to-three orders of magnitude greater than that of the driving wave. Micro-computed tomography was used to study surface erosion and formation of microcracks from the action of microbubbles. This study suggests that engineered microbubbles enable stone-treatment modalities with driving pressures significantly lower than those required without the microbubbles.


Asunto(s)
Simulación por Computador , Elasticidad/fisiología , Microscopía por Video , Cálculos Urinarios/fisiopatología , Acústica , Medios de Contraste/farmacología , Microburbujas , Microscopía por Video/métodos , Modelos Biológicos , Cálculos Urinarios/diagnóstico
3.
Sci Rep ; 9(1): 2244, 2019 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-30783192

RESUMEN

Silicon Microelectromechanical Systems (MEMS) resonators have broad commercial applications for timing and inertial sensing. However, the performance of MEMS resonators is constrained by dissipation mechanisms, some of which are easily detected and well-understood, but some of which have never been directly observed. In this work, we present measurements of the quality factor, Q, for a family of single crystal silicon Lamé-mode resonators as a function of temperature, from 80-300 K. By comparing these Q measurements on resonators with variations in design, dimensions, and anchors, we have been able to show that gas damping, thermoelastic dissipation, and anchor damping are not significant dissipation mechanisms for these resonators. The measured f · Q product for these devices approaches 2 × 1013, which is consistent with the expected range for Akhiezer damping, and the dependence of Q on temperature and geometry is consistent with expectations for Akhiezer damping. These results thus provide the first clear, direct detection of Akhiezer dissipation in a MEMS resonator, which is widely considered to be the ultimate limit to Q in silicon MEMS devices.

4.
ACS Appl Mater Interfaces ; 11(9): 9594-9599, 2019 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-30707831

RESUMEN

The ability to deposit thin and conformal films has become of great importance because of downscaling of devices. However, because of nucleation difficulty, depositing an electrically stable and thin conformal platinum film on an oxide nucleation layer has proven challenging. By using plasma-enhanced atomic layer deposition (PEALD) and TiO2 as a nucleation layer, we achieved electrically continuous PEALD platinum films down to a thickness of 3.7 nm. Results show that for films as thin as 5.7 nm, the Mayadas-Shatzkes (MS) model for electrical conductivity and the Tellier-Tosser model for temperature coefficient of resistance hold. Although the experimental values start to deviate from the MS model below 5.7 nm because of incomplete Pt coverage, the films still show root mean square electrical stability better than 50 ppm over time, indicating that these films are not only electrically continuous but also sufficiently reliable for use in many practical applications.

5.
Ultramicroscopy ; 166: 39-47, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27160487

RESUMEN

Specimen preparation remains a practical challenge in transmission electron microscopy and frequently limits the quality of structural and chemical characterization data obtained. Prevailing methods for thinning of specimens to electron transparency are serial in nature, time consuming, and prone to producing artifacts and specimen failure. This work presents an alternative method for the preparation of plan-view specimens using isotropic vapor-phase etching with integrated etch stops. An ultrathin amorphous etch-stop layer simultaneously serves as an electron transparent support membrane whose thickness is defined by a controlled growth process such as atomic layer deposition with sub-nanometer precision. This approach eliminates the need for mechanical polishing or ion milling to achieve electron transparency, and reduces the occurrence of preparation induced artifacts. Furthermore, multiple specimens from a plurality of samples can be thinned in parallel due to high selectivity of the vapor-phase etching process. These features enable dramatic reductions in preparation time and cost without sacrificing specimen quality and provide advantages over wet etching techniques. Finally, we demonstrate a platform for high-throughput transmission electron microscopy of plan-view specimens by combining the parallel preparation capabilities of vapor-phase etching with wafer-scale micro- and nanofabrication.

6.
ACS Appl Mater Interfaces ; 7(34): 19251-9, 2015 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-26284489

RESUMEN

The ability to efficiently and reliably transfer heat between sources and sinks is often a bottleneck in the thermal management of modern energy conversion technologies ranging from microelectronics to thermoelectric power generation. These interfaces contribute parasitic thermal resistances that reduce device performance and are subjected to thermomechanical stresses that degrade device lifetime. Dense arrays of vertically aligned metal nanowires (NWs) offer the unique combination of thermal conductance from the constituent metal and mechanical compliance from the high aspect ratio geometry to increase interfacial heat transfer and device reliability. In the present work, we synthesize copper NW arrays directly onto substrates via templated electrodeposition and extend this technique through the use of a sacrificial overplating layer to achieve improved uniformity. Furthermore, we infiltrate the array with an organic phase change material and demonstrate the preservation of thermal properties. We use the 3ω method to measure the axial thermal conductivity of freestanding copper NW arrays to be as high as 70 W m(-1) K(-1), which is more than an order of magnitude larger than most commercial interface materials and enhanced-conductivity nanocomposites reported in the literature. These arrays are highly anisotropic, and the lateral thermal conductivity is found to be only 1-2 W m(-1) K(-1). We use these measured properties to elucidate the governing array-scale transport mechanisms, which include the effects of morphology and energy carrier scattering from size effects and grain boundaries.

7.
Sci Rep ; 5: 9036, 2015 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-25762243

RESUMEN

Parametric amplification, resulting from intentionally varying a parameter in a resonator at twice its resonant frequency, has been successfully employed to increase the sensitivity of many micro- and nano-scale sensors. Here, we introduce the concept of self-induced parametric amplification, which arises naturally from nonlinear elastic coupling between the degenerate vibration modes in a micromechanical disk-resonator, and is not externally applied. The device functions as a gyroscope wherein angular rotation is detected from Coriolis coupling of elastic vibration energy from a driven vibration mode into a second degenerate sensing mode. While nonlinear elasticity in silicon resonators is extremely weak, in this high quality-factor device, ppm-level nonlinear elastic effects result in an order-of-magnitude increase in the observed sensitivity to Coriolis force relative to linear theory. Perfect degeneracy of the primary and secondary vibration modes is achieved through electrostatic frequency tuning, which also enables the phase and frequency of the parametric coupling to be varied, and we show that the resulting phase and frequency dependence of the amplification follow the theory of parametric resonance. We expect that this phenomenon will be useful for both fundamental studies of dynamic systems with low dissipation and for increasing signal-to-noise ratio in practical applications such as gyroscopes.

8.
Proc Natl Acad Sci U S A ; 110(51): 20426-30, 2013 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-24309375

RESUMEN

Reliably routing heat to and from conversion materials is a daunting challenge for a variety of innovative energy technologies--from thermal solar to automotive waste heat recovery systems--whose efficiencies degrade due to massive thermomechanical stresses at interfaces. This problem may soon be addressed by adhesives based on vertically aligned carbon nanotubes, which promise the revolutionary combination of high through-plane thermal conductivity and vanishing in-plane mechanical stiffness. Here, we report the data for the in-plane modulus of aligned single-walled carbon nanotube films using a microfabricated resonator method. Molecular simulations and electron microscopy identify the nanoscale mechanisms responsible for this property. The zipping and unzipping of adjacent nanotubes and the degree of alignment and entanglement are shown to govern the spatially varying local modulus, thereby providing the route to engineered materials with outstanding combinations of mechanical and thermal properties.

9.
Sci Rep ; 3: 3244, 2013 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-24247809

RESUMEN

Micromechanical resonators are promising replacements for quartz crystals for timing and frequency references owing to potential for compactness, integrability with CMOS fabrication processes, low cost, and low power consumption. To be used in high performance reference application, resonators should obtain a high quality factor. The limit of the quality factor achieved by a resonator is set by the material properties, geometry and operating condition. Some recent resonators properly designed for exploiting bulk-acoustic resonance have been demonstrated to operate close to the quantum mechanical limit for the quality factor and frequency product (Q-f). Here, we describe the physics that gives rise to the quantum limit to the Q-f product, explain design strategies for minimizing other dissipation sources, and present new results from several different resonators that approach the limit.

10.
Nano Lett ; 12(2): 683-6, 2012 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-22224582

RESUMEN

While the literature is rich with data for the electrical behavior of nanotransistors based on semiconductor nanowires and carbon nanotubes, few data are available for ultrascaled metal interconnects that will be demanded by these devices. Atomic layer deposition (ALD), which uses a sequence of self-limiting surface reactions to achieve high-quality nanolayers, provides an unique opportunity to study the limits of electrical and thermal conduction in metal interconnects. This work measures and interprets the electrical and thermal conductivities of free-standing platinum films of thickness 7.3, 9.8, and 12.1 nm in the temperature range from 50 to 320 K. Conductivity data for the 7.3 nm bridge are reduced by 77.8% (electrical) and 66.3% (thermal) compared to bulk values due to electron scattering at material and grain boundaries. The measurement results indicate that the contribution of phonon conduction is significant in the total thermal conductivity of the ALD films.


Asunto(s)
Membranas Artificiales , Nanopartículas del Metal/química , Platino (Metal)/química , Conductividad Térmica , Conductividad Eléctrica , Tamaño de la Partícula , Propiedades de Superficie
11.
Biomed Microdevices ; 9(6): 939-49, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17574533

RESUMEN

Experiments were conducted to evaluate a silicon accelerometer as an implantable sound sensor for implantable hearing aids. The main motivation of this study is to find an alternative sound sensor that is implantable inside the body, yet does not suffer from the signal attenuation from the body. The merit of the accelerometer sensor as a sound sensor will be that it will utilize the natural mechanical conduction in the middle ear as a source of the vibration. With this kind of implantable sound sensor, a totally implantable hearing aid is feasible. A piezoresistive silicon accelerometer that is completely encapsulated with a thin silicon film and long flexible flex-circuit electrical cables were used for this study. The sensor is attached on the middle ear ossicles and measures the vibration transmitted from the tympanic membrane due to the sound in the ear canal. In this study, the sensor is fully characterized on a human cadaveric temporal bone preparation.


Asunto(s)
Aceleración , Audífonos , Prótesis e Implantes , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Miniaturización , Vibración
12.
Anal Chem ; 75(5): 1180-7, 2003 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-12641239

RESUMEN

We have developed an acrylic microfluidic device that sequentially couples liquid-phase isoelectric focusing (IEF) and free solution capillary electrophoresis (CE). Rapid separation (<1 min) and preconcentration (73x) of species were achieved in the initial IEF dimension. Using full-field fluorescence imaging, we observed nondispersive mobilization velocities on the order of 20 microm/s during characterization of the IEF step. This transport behavior allowed controlled electrokinetic mobilization of focused sample bands to a channel junction, where voltage switching was used to repeatedly inject effluent from the IEF dimension into an ampholyte-based CE separation. This second dimension was capable of analyzing all fluid volumes of interest from the IEF dimension, as IEF was 'parked' during each CE analysis and refocused prior to additional CE analyses. Investigation of each dimension of the integrated system showed time-dependent species displacement and band-broadening behavior consistent with IEF and CE, respectively. The peak capacity of the 2D system was approximately 1300. A comprehensive 2D analysis of a fluid volume spanning 15% of the total IEF channel length was completed in less than 5 min.


Asunto(s)
Electroforesis/instrumentación , Focalización Isoeléctrica/instrumentación , Microcomputadores , Algoritmos , Diagnóstico por Imagen , Indicadores y Reactivos
13.
Proc Natl Acad Sci U S A ; 99(19): 12252-6, 2002 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-12198184

RESUMEN

Geckos have evolved one of the most versatile and effective adhesives known. The mechanism of dry adhesion in the millions of setae on the toes of geckos has been the focus of scientific study for over a century. We provide the first direct experimental evidence for dry adhesion of gecko setae by van der Waals forces, and reject the use of mechanisms relying on high surface polarity, including capillary adhesion. The toes of live Tokay geckos were highly hydrophobic, and adhered equally well to strongly hydrophobic and strongly hydrophilic, polarizable surfaces. Adhesion of a single isolated gecko seta was equally effective on the hydrophobic and hydrophilic surfaces of a microelectro-mechanical systems force sensor. A van der Waals mechanism implies that the remarkable adhesive properties of gecko setae are merely a result of the size and shape of the tips, and are not strongly affected by surface chemistry. Theory predicts greater adhesive forces simply from subdividing setae to increase surface density, and suggests a possible design principle underlying the repeated, convergent evolution of dry adhesive microstructures in gecko, anoles, skinks, and insects. Estimates using a standard adhesion model and our measured forces come remarkably close to predicting the tip size of Tokay gecko seta. We verified the dependence on size and not surface type by using physical models of setal tips nanofabricated from two different materials. Both artificial setal tips stuck as predicted and provide a path to manufacturing the first dry, adhesive microstructures.


Asunto(s)
Lagartos/fisiología , Adhesividad , Animales , Fenómenos Biofísicos , Biofisica , Extremidades/fisiología , Interacciones Hidrofóbicas e Hidrofílicas , Modelos Biológicos , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...