Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neurosurg Case Lessons ; 7(8)2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38373298

RESUMEN

BACKGROUND: Brachioradial pruritus (BRP) is a rare form of chronic dysesthesia characterized by persistent itching, burning, or tingling commonly involving the dorsolateral upper extremities. Although the exact pathophysiology remains unclear, the condition may be a manifestation of atypical cervical radiculopathy. OBSERVATIONS: The authors describe two patients with BRP, a 44-year-old female and a 51-year-old male, both of whom benefited from surgical intervention for atypical cervical radiculopathy, while also highlighting their presentation, diagnostic testing, treatment, and outcomes. LESSONS: The cases demonstrate the potential relationship between cervical spondylosis and BRP while examining the role of surgical intervention as a treatment option.

2.
Neurospine ; 21(1): 20-29, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38317548

RESUMEN

Spinal robotics have the potential to improve the consistency of outcomes in adult spinal deformity (ASD) surgery. The objective of this paper is to assess the accuracy of pedicle and S2 alar-iliac (S2AI) screws placed with robotic guidance in ASD patients. PubMed Central, Google Scholar, and an institutional library database were queried until May 2023. Articles were included if they described ASD correction via robotic guidance and pedicle and/or S2AI screw accuracy. Articles were excluded if they described pediatric/adolescent spinal deformity or included outcomes for both ASD and non-ASD patients without separating the data. Methodological quality was assessed using the Newcastle-Ottawa scale. Primary endpoints were pedicle screw accuracy based on the Gertzbein-Robbins Scale and self-reported accuracy percentages for S2AI screws. Data were extracted for patient demographics, operative details, and perioperative outcomes and assessed using descriptive statistics. Five studies comprising 138 patients were included (mean age 66.0 years; 85 females). A total of 1,508 screws were inserted using robotic assistance (51 S2AI screws). Two studies assessing pedicle screws reported clinically acceptable trajectory rates of 98.7% and 96.0%, respectively. Another study reported a pedicle screw accuracy rate of 95.5%. Three studies reported 100% accuracy across 51 total S2AI screws. Eight total complications and 4 reoperations were reported. Current evidence supports the application of robotics in ASD surgery as safe and effective for placement of both screw types. However, due to the paucity of data, a comprehensive assessment of its incremental benefit over other techniques cannot be made. Further work using expanded cohorts is merited.

3.
Cureus ; 13(4): e14283, 2021 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-33959461

RESUMEN

This study aimed to assess clinical and radiological outcomes associated with zero-profile stand-alone cages with instrumentation used for single- and multilevel anterior cervical discectomy and fusion (ACDF) operations. Many plate-cage ACDF systems have proven to be successful in producing high fusion rates and positive clinical outcomes. However, the anterior plating in traditional systems has been associated with complications such as dysphagia and mechanical accidents. A total of 190 patients underwent single- or multilevel ACDF surgeries with zero-profile polyetheretherketone cages containing integrated titanium instrumentation and screw fixation (one-level, n=31; two-level, n=65; three-level, n=71; four-level, n=23). Demographic information such as age and smoking status as well as postoperative outcomes were collected and analysed. Out of the 190 patients who underwent ACDF surgeries with a zero-profile stand-alone cage, none experienced any conditions or infections, and zero were readmitted postoperatively. Although traditional plate-cage systems yield high fusion rates in ACDF surgeries, zero-profile systems with integrated fixation have showcased impressive clinical and radiographic results in both single- and multilevel operations.

4.
Cureus ; 13(3): e13886, 2021 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-33868850

RESUMEN

A systematic literature review was conducted on studies comparing interspinous process (ISP) devices to traditional methods of posterior spinal instrumentation (pedicle screw-rod construct), in terms of indications of use, complications, pain assessment, estimated blood loss, length of hospital stay, reoperation rates, and return to work. The objective was to analyze, evaluate and summarize the current published literature on the proposed efficacy and clinical and surgical long-term outcomes of the ISP device in comparison to the traditional posterior spinal instrumentation (pedicle screw-rod construct). The ISP device is a minimally invasive and less disruptive alternative to traditional methods of posterior spinal instrumentation (pedicle screw-rod construct). However, very few published literature studies to date have reported the comparison of ISPs in terms of efficacy and clinical and surgical outcomes, to traditional posterior spinal instrumentation. A systematic literature review was performed in PubMed and Google Scholar to evaluate the results of published research that meet the defined inclusion and exclusion criteria and to analyze clinical indications and surgical outcomes of the ISP device compared to traditional methods of posterior spinal instrumentation (pedicle screw-rod construct). Inclusion criteria included keywords such as "ISP device, ISP, posterior spinal instrumentation, pedicle screw fixation, bilateral pedicle screws, interbody fusion with posterior spinal instrumentation, lumbar spinal stenosis, and posterior lumbar stability." No exclusion criteria keywords were included in this literature review. ISPs provide a high degree of spinal stability in multiple planes, including a decreased range of motion restriction in flexion-extension, and comparable results to bilateral pedicle screw (BPS) in axial rotation. The use of the ISP device in adjunct with an interbody fusion, ensures less estimated operative blood loss (EBL), shorter operative time, less bony exposure without the need for extensive soft tissue or muscle retraction, a decrease in the rate of pseudoarthrosis, and a shorter length of hospital stay (LOHS) when compared to the traditional posterior instrumentation (pedicle screw-rod construct). Based on the various published literature reviews noted throughout this research paper, it is safe to conclude, that an ISP device that is accompanied by interbody fusion, including posterior approaches posterior lumbar interbody fusion (PLIF) and transforaminal lumbar interbody fusion (TLIF); anterior approaches such as anterior interbody fusion (ALIF), and lateral approaches including direct lateral interbody fusion (DLIF), lateral lumbar interbody fusion (LLIF), extreme lateral interbody fusion (XLIF), is considered a credible and an effective minimally invasive option for the treatment of mild to moderate lumbar stenosis and stable low-grade spondylolisthesis (less than two) when compared to the traditional posterior spinal instrumentation of a pedicle screw-rod construct. Surgeons that are relatively new to the ISP technologies for spinal instrumentation would likely benefit from more clinical and surgical evidence of safety and efficacy in published peer-reviewed medical literature. Further clinical trials are needed to manifest the efficacy of ISPs regarding postoperative outcomes when compared to traditional posterior instrumentation techniques (pedicle screw-rod construct) with adjunct interbody fusions.