Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 254: 116204, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38507929

RESUMEN

Autophagy is an early-stage response with self-degradation properties against several insulting conditions. To date, the critical role of autophagy has been well-documented in physiological and pathological conditions. This process involves various signaling and functional biomolecules, which are involved in different steps of the autophagic response. During recent decades, a range of biochemical analyses, chemical assays, and varied imaging techniques have been used for monitoring this pathway. Due to the complexity and dynamic aspects of autophagy, the application of the conventional methodology for following autophagic progression is frequently associated with a mistake in discrimination between a complete and incomplete autophagic response. Biosensors provide a de novo platform for precise and accurate analysis of target molecules in different biological settings. It has been suggested that these devices are applicable for real-time monitoring and highly sensitive detection of autophagy effectors. In this review article, we focus on cutting-edge biosensing technologies associated with autophagy detection.


Asunto(s)
Técnicas Biosensibles , Autofagia
2.
Food Chem ; 439: 138145, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38091787

RESUMEN

Antibiotic residuals in foods may lead to crucial health and safety issues in the human body. Rapid and in-time analysis of antibiotics using simple and sensitive techniques is in high demand. Among the most commonly applicable modalities, chromatography-based techniques like HPLC and LC-MS, along with immunological approaches, particularly ELISA have been exampled in the analysis of antibiotics. Despite being highly sensitive, these methods are considerably time-consuming, thus the presence of skilled personnel and costly equipment is essential. Nanomaterial-based (bio)sensors, however, are de novo analytical equipment with some beneficial characteristics, such as simplicity, low price, on-site, high accuracy, and sensitivity for the detection of analytes. This review aimed to collect the latest developments in NM-based sensors and biosensors for the observation of highly used antibiotics like Vancomycin (Van), Linezolid (Lin), and Clindamycin (Clin). The current challenges and developmental perspectives are also debated in detail for future research directions.


Asunto(s)
Técnicas Biosensibles , Nanoestructuras , Humanos , Antibacterianos/análisis , Ensayo de Inmunoadsorción Enzimática , Linezolid , Vancomicina , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos
3.
Food Chem X ; 20: 100883, 2023 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-38144784

RESUMEN

As tetracycline antibiotics were used in the poultry sector, their residue in edible animal products may adversely affect food safety and human health. The development of selective and sensitive tetracycline sensors has garnered a lot of interest due to the complexity of food samples. Therefore, a fluorescent sensing probe based on chromium(III)-metal-organic framework was developed for the rapid detection of tetracycline. After the addition of tetracycline, blue emission at λem 410 nm was effectively quenched by the interaction between TC and Cr(III)-metal-organic framework material. Under optimized conditions (sensor concentration: 30 mg/L and pH: 10.0), the sensing probe showed a fast response time (1 min), and low detection limit (0.78 ng/mL) with a linear range (5-45 ng/mL). Interestingly, the Cr(III)-metal-organic framework was successfully applied to quantity tetracycline residue in chicken meat and egg samples with recoveries of 95.17-06.93%. To deduce, our work can provide a new strategy for the direct detection of tetracycline in food samples.

4.
Sci Rep ; 13(1): 16163, 2023 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-37758805

RESUMEN

Alzheimer's disease (AD) is a progressive brain disorder characterized by the ongoing decline of brain functions. Studies have revealed the detrimental effects of hyperphosphorylated tau (p-tau) protein fibrils in AD pathogenesis, highlighting the importance of this factor in the early-stage detection of AD conditions. We designed an electrochemical immunosensor for quantitative detection of the cis conformation of the p-tau protein (cis-p-tau) employing platinum nanoparticles (Pt NPs) supported on zeolitic imidazolate frameworks (ZIF) for modifying the glassy carbon electrode (GCE) surface. Under optimum conditions, the immunosensor selectively and sensitively detected cis-p-tau within the broad linear range of 1 fg mL-1 to 10 ng mL-1 and the low limit of detection (LOD) of 1 fg mL-1 with desired reproducibility and stability. Furthermore, the fabricated immunosensor's performance was examined for the cis-p-tau analysis in the serum of AD patients, indicating its accuracy and feasibility for real-sample analysis. Notably, this is the first application of Pt@ZIF-8 nanocomposite in fabricating a valid immunosensor for selective cis-p-tau detection, even in the presence of trans-p-tau. It is worth mentioning that the enzyme-linked immunosorbent assay (ELISA) reference technique is not able to evaluate pico- or femtomolar concentrations of cis-p-tau, making the fabricated immunosensor superior for early-stage measurement and screening of AD.


Asunto(s)
Enfermedad de Alzheimer , Técnicas Biosensibles , Nanopartículas del Metal , Nanocompuestos , Zeolitas , Humanos , Enfermedad de Alzheimer/diagnóstico , Proteínas tau , Zeolitas/química , Nanopartículas del Metal/química , Reproducibilidad de los Resultados , Inmunoensayo , Platino (Metal)/química , Nanocompuestos/química , Técnicas Electroquímicas , Límite de Detección , Oro/química
5.
Mikrochim Acta ; 190(9): 371, 2023 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-37646854

RESUMEN

The measurement of food contaminants faces a great challenge owing to the increasing demand for safe food, increasing consumption of fast food, and rapidly changing patterns of human consumption. As different types of contaminants in food products can pose different levels of threat to human health, it is desirable to develop specific and rapid methods for their identification and quantification. During the past few years, metal-organic framework (MOF)-based materials have been extensively explored in the development of food safety sensors. MOFs are porous crystalline materials with tunable composition, dynamic porosity, and facile surface functionalization. The construction of high-performance biosensors for a range of applications (e.g., food safety, environmental monitoring, and biochemical diagnostics) can thus be promoted through the synergistic combination of MOFs with aptamers. Accordingly, this review article delineates recent innovations achieved for the aptamer-functionalized MOFs toward the detection of food contaminants. First, we describe the basic concepts involved in the detection of food contaminants in terms of the advantages and disadvantages of the commonly used analytical methods (e.g., DNA-based methods (PCR/real-time PCR/multiplex PCR/digital PCR) and protein-based methods (enzyme-linked immunosorbent assay/immunochromatography assay/immunosensor/mass spectrometry). Afterward, the progress in aptamer-functionalized MOF biosensors is discussed with respect to the sensing mechanisms (e.g., the role of MOFs as signal probes and carriers for loading signal probes) along with their performance evaluation (e.g., in terms of sensitivity). We finally discuss challenges and opportunities associated with the development of aptamer-functionalized MOFs for the measurement of food contaminants.


Asunto(s)
Técnicas Biosensibles , Estructuras Metalorgánicas , Humanos , Inmunoensayo , Oligonucleótidos , Alimentos Procesados
6.
Mikrochim Acta ; 190(7): 253, 2023 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-37286753

RESUMEN

An innovative aptamer labeled with 5-FAM has been developed with a high affinity for Yersinia enterocolitica (Y. enterocolitica) using graphene oxide (GO) as a quenching platform. The selectivity of the prepared system was evaluated in the presence of common coexisted bacteria like Yersinia pseudotuberculosis, Staphylococcus aureus, Listeria monocytogenes, Escherichia coli, and Salmonella typhimurium. Some experimental factors like pH and stability were investigated. The results showed that in the absence of Y. enterocolitica, aptamer labeled with 5-FAM was bonded with GO, causing fluorescence to be relatively weak. After the addition of Y. enterocolitica, the aptamer is released from the GO surface and binds to the target bacteria, and significantly increases the fluorescence intensity with an excitation wavelength of 410 nm and an emission wavelength of 530 nm. After optimizing all conditions, the system exhibited a wide linear response for Y. enterocolitica in the concentration range 10 to 1.0 × 109 CFU•mL-1 and the limit of detection (LOD) was 3 CFU•mL-1. This system demonstrated that GO-designed aptamers can be successful in detecting Y. enterocolitica in whole-cell forms, making them potentially useful for screening and rapid detection.


Asunto(s)
Yersinia enterocolitica , Yersinia pseudotuberculosis , Límite de Detección , Salmonella typhimurium , Oligonucleótidos , Escherichia coli
7.
Sci Rep ; 13(1): 6847, 2023 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-37100835

RESUMEN

Breast cancer (BC) is one of the most commonly diagnosed cancers and the second leading cause of cancer mortality among women around the world. The purpose of this study is to present a non-labeled liquid crystal (LC) biosensor, based on the inherent feature of nematic LCs, for the evaluation of BC using the human epidermal growth factor receptor-2 (HER-2) biomarker. The mechanism of this sensing is supported by surface modification with dimethyloctadecyl [3-(trimethoxysilyl) propyl] ammonium chloride (DMOAP) encouraging the long alkyl chains that induce a homeotropic orientation of the LC molecules at the interface. To enhance the binding efficacy of more HER-2 antibody (Ab) on LC aligning agents, a simple ultraviolet radiation-assisted method was also used to increase functional groups on the DMOAP coated slides, thereby improving binding affinity and efficiency onto HER-2 Abs. The designed biosensor makes use of the specific binding of HER-2 protein to HER-2 Ab and disruption of the orientation of LCs. This orientation change leads to a transition of the optical appearance from dark to birefringent, enabling the detection of HER-2. This novel biosensor exhibits a linear optical response to HER-2 concentration in the wide dynamic range of 10-6-102 ng/mL, with an ultra-low detection limit of 1 fg/mL. As a proof of concept, the designed LC biosensor was successfully investigated for the quantification of HER-2 protein in patients suffering from BC. Owing to the sensitivity, selectivity, and label-free detection, this biosensor may amplify the application of LC-based biosensors for the detection of most types of cancers.


Asunto(s)
Técnicas Biosensibles , Cristales Líquidos , Glándulas Mamarias Humanas , Humanos , Femenino , Cristales Líquidos/química , Rayos Ultravioleta , Oncogenes , Anticuerpos , Técnicas Biosensibles/métodos
8.
Biosensors (Basel) ; 13(2)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36831982

RESUMEN

Listeria monocytogenes (L.M.) is a gram-positive bacillus with wide distribution in the environment. This bacterium contaminates water sources and food products and can be transmitted to the human population. The infection caused by L.M. is called listeriosis and is common in pregnant women, immune-deficient patients, and older adults. Based on the released statistics, listeriosis has a high rate of hospitalization and mortality; thus, rapid and timely detection of food contamination and listeriosis cases is necessary. During the last few decades, biosensors have been used for the detection and monitoring of varied bacteria species. These devices are detection platforms with great sensitivity and low detection limits. Among different types of biosensors, electrochemical biosensors have a high capability to circumvent several drawbacks associated with the application of conventional laboratory techniques. In this review article, different electrochemical biosensor types used for the detection of listeriosis were discussed in terms of actuators, bioreceptors, specific working electrodes, and signal amplification. We hope that this review will facilitate researchers to access a complete and comprehensive template for pathogen detection based on the different formats of electrochemical biosensors.


Asunto(s)
Técnicas Biosensibles , Listeria monocytogenes , Listeriosis , Embarazo , Humanos , Femenino , Anciano , Listeriosis/epidemiología , Listeriosis/microbiología , Contaminación de Alimentos/análisis , Técnicas Biosensibles/métodos , Electrodos , Microbiología de Alimentos
9.
Mikrochim Acta ; 190(3): 90, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-36786882

RESUMEN

A green, environmentally friendly protocol was developed for ultrasensitive and highly specific recognition of prostate-specific antigen (PSA) based on the ECL effect of luminol supported by chitosan-silver nanoparticles (CS/AgNPs) nanocomposites. The transducing surface was fabricated through two consecutive electrodeposition steps of gold nanoparticles (AuNPs) and chitosan (CS)-AgNPs-luminol electrochemiluminophore onto the glassy carbon electrode. In addition to an appropriate desirable biocompatibility, the electrochemical synthesis presents low-cost preparation and ultrafast determination opportunity. AgNPs play a linking role to attach luminol, as an ECL agent to the CS support via donor-acceptor bonds between Ag atoms with NH groups of luminol and CS. Also, AgNPs can amplify the ECL intensity as a consequence of their excellent specific surface area and conductivity. To enhance the performance of the nanobiosensor, AuNPs were also used due to their high-specific surface area and excellent affinity toward amine groups of CS. Based on this high-performance analysis strategy, ultrasensitive screening of PSA was attained with a desirable limit of detection of 0.6 ng mL-1 and a broad linear range between 1 pg mL-1 and 10 ng⋅mL-1 (R2=0.994). Approximately, the same results were recorded for the analysis of the unprocessed serum samples of patients with prostate cancer at different stages. This research provided significant insight into electrografting methods to construct ECL transducers for clinical monitoring of PSA and other tumor biomarkers in the clinical setting.


Asunto(s)
Quitosano , Nanopartículas del Metal , Nanocompuestos , Humanos , Masculino , Quitosano/química , Oro/química , Mediciones Luminiscentes/métodos , Luminol/química , Nanopartículas del Metal/química , Nanocompuestos/química , Antígeno Prostático Específico , Plata , Técnicas Electroquímicas
10.
Mikrochim Acta ; 190(2): 77, 2023 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-36715890

RESUMEN

Recently, electrochemiluminescent (ECL) immunosensors have received much attention in the field of biomarker detection. Here, a highly enhanced ECL immunosensing platform was designed for ultrasensitive detection of carcinoembryonic antigen (CEA). The surface of the glassy carbon electrode was enhanced by applying functional nanostructures such as thiolated graphene oxide (S-GO) and streptavidin-coated gold nanoparticles (SA-AuNPs). The selectivity and sensitivity of the designed immunosensor were improved by entrapping CEA biomolecules using a sandwich approach. Luminol/silver nanoparticles (Lu-SNPs) were applied as the main core of the signaling probe, which were then coated with streptavidin to provide overloading of the secondary antibody. The highly ECL signal enhancement was obtained due to the presence of horseradish peroxidase (HRP) in the signaling probe, in which the presence of H2O2 further amplified the intensity of the signals. The engineered immunosensor presented excellent sensitivity for CEA detection, with limit of detection (LOD) and linear detection range (LDR) values of 58 fg mL-1 and 0.1 pg mL-1 to 5 pg mL-1 (R2 = 0.9944), respectively. Besides its sensitivity, the fabricated ECL immunosensor presented outstanding selectivity for the detection of CEA in the presence of various similar agents. Additionally, the developed immunosensor showed an appropriate repeatability (RSD 3.8%) and proper stability (2 weeks). Having indicated a robust performance in the real human serum with stated LOD and LDR, the engineered immunosensor can be considered for the detection and monitoring of CEA in the clinic.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Nanocompuestos , Humanos , Luminol/química , Antígeno Carcinoembrionario , Oro/química , Plata/química , Nanopartículas del Metal/química , Peróxido de Hidrógeno , Estreptavidina , Mediciones Luminiscentes , Inmunoensayo , Nanocompuestos/química
11.
Biosens Bioelectron ; 222: 114980, 2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36521207

RESUMEN

The tumor microenvironment consists of a multiplicity of cells such as cancer cells, fibroblasts, endothelial cells, and immune cells within the specific parenchyma. It has been indicated that cancer cells can educate other cells within the tumor niche in a paracrine manner by the release of nano-sized extracellular vesicles namely exosomes (Exo), resulting in accelerated tumor mass growth. It is suggested that exosomal cargo with remarkable information can reflect any changes in metabolic and proteomic profiles in parent tumor cells. Therefore, exosomes can be touted as prognostic, diagnostic, and therapeutic elements with specific biomarkers in patients with different tumor types. Despite the advantages, conventional exosome separation and purification protocols are time-consuming and laborious with low abnormal morphology and purity rate. During the last decades, biosensor-based modalities, as emerging instruments, have been used to detect and analyze Exo in biofluids. Due to suitable specificity, sensitivity, and real-time readout, biosensors became promising approaches for the analysis of Exo in in vitro and in vivo settings. The inherent advantages and superiority of electrochemical biosensors in the determination of tumor grade based on exosomal cargo and profile were also debated. Present and future challenges were also discussed related to the application of electrochemical biosensors in the clinical setting. In this review, the early detection of several cancer types associated with ovaries, breast, brain, colon, lungs, T and B lymphocytes, liver and rare types of cancers were debated in association with released exosomes.


Asunto(s)
Técnicas Biosensibles , Exosomas , Neoplasias , Humanos , Técnicas Biosensibles/métodos , Exosomas/química , Proteómica , Células Endoteliales/química , Biomarcadores de Tumor/análisis , Neoplasias/patología , Microambiente Tumoral
12.
Med Res Rev ; 43(3): 464-569, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36464910

RESUMEN

Breast cancer is categorized as the most widespread cancer type among women globally. On-time diagnosis can decrease the mortality rate by making the right decision in the therapy procedure. These features lead to a reduction in medication time and socioeconomic burden. The current review article provides a comprehensive assessment for breast cancer diagnosis using nanomaterials and related technologies. Growing use of the nano/biotechnology domain in terms of electrochemical nanobiosensor designing was discussed in detail. In this regard, recent advances in nanomaterial applied for amplified biosensing methodologies were assessed for breast cancer diagnosis by focusing on the advantages and disadvantages of these approaches. We also monitored designing methods, advantages, and the necessity of suitable (nano) materials from a statistical standpoint. The main objective of this review is to classify the applicable biosensors based on breast cancer biomarkers. With numerous nano-sized platforms published for breast cancer diagnosis, this review tried to collect the most suitable methodologies for detecting biomarkers and certain breast cancer cell types.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Mama , Nanoestructuras , Femenino , Humanos , Biomarcadores de Tumor , Neoplasias de la Mama/diagnóstico , Nanotecnología/métodos , Biomarcadores , Nanoestructuras/química , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos
13.
Environ Res ; 214(Pt 3): 113966, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35952738

RESUMEN

Alginate-grafted polyaniline (Alg-g-PANI) microparticles were synthesized through the grafting of aniline onto functionalized Alg followed by double crosslinking by glutaraldehyde and calcium chloride. The performance of the developed microparticles as adsorbent in simultaneous removal of malachite green (MG) and congo red (CR) dyes were examined by the batch method. Experimental parameters, including adsorbent amount, pH, initial dyes concentrations, and contact time were optimized. Langmuir and Freundlich adsorption models were employed to explore the equilibrium isotherm. As the Langmuir model results, the maximum adsorption capacities (Qm) of microparticles for the MG and CR dyes were obtained as 578.3 and 409.6 mgg-1, respectively. Adsorption kinetics for both dyes were well-fitted with the pseudo-second-order model that confirm the rate-limiting step might be the chemical adsorption. The adsorbent was regenerated via desorption process and was reusable five times without a substantial decrease in its adsorption efficacy in first three cycles. Adsorbent-dyes interactions were computationally evaluated using Gromacs package, and it was found that both MG and CR are able to interact strongly with the adsorbent. In accordance with experimental results, simulation data revealed that MG can be removed more efficiently than those of the CR. As the experimental results, we could conclude that the synthesized Alg-g-PANI microparticles can be used as a nature-inspired adsorbent for simultaneous removals of CR and MG dyes.


Asunto(s)
Colorantes , Contaminantes Químicos del Agua , Adsorción , Aniones , Cationes , Rojo Congo , Concentración de Iones de Hidrógeno , Cinética , Contaminantes Químicos del Agua/análisis
14.
Molecules ; 27(2)2022 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-35056745

RESUMEN

Human Tau protein is the most reliable biomarker for the prediction of Alzheimer's disease (AD). However, the assay to detect low concentrations of tau protein in serum is a great challenge for the early diagnosis of AD. This paper reports an electrochemiluminescence (ECL) immunosensor for Tau protein in serum samples. Gold nanostars (AuNSs) decorated on carbon nitride nanosheets (AuNS@g-CN nanostructure) show highly strong and stable ECL activity compared to pristine CN nanosheets due to the electrocatalytic and surface plasmon effects of AuNSs. As a result of the strong electromagnetic field at branches, AuNSs showed a better ECL enhancement effect than their spherical counterpart. For the fabrication of a specific immunosensor, immobilized AuNSs were functionalized with a monoclonal antibody specific for Tau protein. In the presence of Tau protein, the ECL intensity of the immunosensor decreased considerably. Under the optimal conditions, this ECL based immunosensor exhibits a dynamic linear range from 0.1 to 100 ng mL-1 with a low limit of detection of 0.034 ng mL-1. The LOD is less than the Tau level in human serum; thus, this study provides a useful method for the determination of Tau. The fabricated ECL immunosensor was successfully applied to the detection of Tau, the biomarker in serum samples. Therefore, the present approach is very promising for application in diagnosing AD within the early stages of the disease.


Asunto(s)
Enfermedad de Alzheimer/sangre , Técnicas Biosensibles/métodos , Nanoestructuras/química , Proteínas tau/sangre , Área Bajo la Curva , Técnicas Biosensibles/instrumentación , Oro/química , Humanos , Límite de Detección , Mediciones Luminiscentes , Microscopía Electrónica de Rastreo , Nitrilos/química , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta , Proteínas tau/inmunología
16.
Sci Rep ; 11(1): 23994, 2021 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-34907220

RESUMEN

Biopolymer films have drawn growing demand for their application in the point of care domain owing to their biocompatibility, eco-friendly, and eligibility for in vivo analyses. However, their poor conductivity restricts their sensitivity in diagnostics. For high-quality electrochemical biosensor monitoring, two vital factors to be greatly paid attention are the effective merge of amplification modifiers with transducing surface and the superior linking across the recognition interface. Here, we introduce an enzyme-free electrochemical biosensor based on electrosynthesized biocompatible WO3/poly glutamic acid nano-biocomposites to address the hardships specific to the analysis of circulating proteins clinical samples. In addition to its green synthesis route, the poor tendency of both components of the prepared nano-biocomposite to amine groups makes it excellent working in untreated biological samples with high contents of proteins. Several electrochemical and morphological investigations (SEM, EDX, and dot mapping) were fulfilled to gain a reliable and trustful standpoint of the framework. By using this nanobiosensor, the concentration of HER-2 was detectable as low as 1 fg mL-1 with a wide linear response between 1 ng mL-1 and 1 fg mL-1. Meanwhile, the protocol depicted ideal specificity, stability, and reproducibility for the detection of HER-2 protein in untreated serum samples of breast cancer patients.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Mama/sangre , Técnicas Electroquímicas , Ácido Glutámico/química , Nanopartículas del Metal/química , Nanocompuestos/química , Óxidos/química , Receptor ErbB-2/sangre , Tungsteno/química , Femenino , Tecnología Química Verde , Humanos
17.
Life Sci ; 286: 120041, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34637796

RESUMEN

Mouse CD90+ SSCs were enriched using the MACS technique and incubated with different doses of estradiol, ranging from 0.01 ng/mL to 500 µg/mL, for 7 days. The viability of SSCs was determined using an MTT assay. The combined effects of estradiol plus Sertoli cell differentiation medium on the orientation of SSCs toward Sertoli-like cells were also assessed. Using immunofluorescence imaging, we monitored protein levels of Oct3/4 after being exposed to estradiol. In addition, protein levels of testosterone, TF, and ABP were measured using ELISA. The expression of Sertoli cell-specific genes such as SOX9, GATA4, FSHR, TF, and ESR-1 and -2 was monitored using real-time PCR assay, and the effects of 14-day injection of estradiol on sperm parameters and Oct3/4 positive progenitor cells in a model of mouse were determined. Data showed that estradiol increased the viability of mouse SSCs in a dose-dependent manner compared to the control (p < 0.05). Along with these changes, cells displayed morphological changes and reduced Oct3/4 transcription factor levels compared to the control SSCs. 7-day incubation of SSCs with estradiol led to the up-regulation of SOX9, GATA4, FSHR, TF, and ESR-1 and -2, and levels of testosterone, TF, and ABP were increased compared to the control group (p < 0.05). The in-vivo examination noted that estradiol reduced sperm parameters coincided with morphological abnormalities (p < 0.05). Histological examination revealed pathological changes in seminiferous tubules and reduction of testicular Oct3/4+ progenitor cells. In conclusion, estradiol treatment probably can induce Sertoli cell differentiation of SSCs while exogenous administration leads to testicular progenitor cell depletion and infertility in long term.


Asunto(s)
Células Madre Germinales Adultas/metabolismo , Estradiol/farmacología , Espermatogénesis/fisiología , Células Madre Germinales Adultas/efectos de los fármacos , Animales , Diferenciación Celular/efectos de los fármacos , Estradiol/metabolismo , Masculino , Ratones , Ratones Endogámicos BALB C , ARN Mensajero/genética , Células de Sertoli/metabolismo , Espermatogénesis/efectos de los fármacos , Espermatozoides/efectos de los fármacos , Espermatozoides/metabolismo , Células Madre/efectos de los fármacos , Células Madre/metabolismo , Testículo/metabolismo , Testosterona/metabolismo
18.
Sci Rep ; 11(1): 14921, 2021 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-34290319

RESUMEN

In the present article, we developed a highly sensitive label-free electrochemical immunosensor based on NiFe-layered double hydroxides (LDH)/reduced graphene oxide (rGO)/gold nanoparticles modified glassy carbon electrode for the determination of receptor tyrosine kinase-like orphan receptor (ROR)-1. In this electrochemical immunoassay platform, NiFe-LDH/rGO was used due to great electron mobility, high specific surface area and flexible structures, while Au nanoparticles were prepared and coated on the modified electrodes to improve the detection sensitivity and ROR1 antibody immobilizing (ROR1Ab). The modification procedure was approved by using cyclic voltammetry and differential pulse voltammetry based on the response of peak current to the step by step modifications. Under optimum conditions, the experimental results showed that the immunosensor revealed a sensitive response to ROR1 in the range of 0.01-1 pg mL-1, and with a lower limit of quantification of 10 attogram/mL (10 ag mL-1). Furthermore, the designed immunosensor was applied for the analysis of ROR1 in several serum samples of chronic lymphocytic leukemia suffering patients with acceptable results, and it also exhibited good selectivity, reproducibility and stability.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Compuestos Férricos , Oro , Grafito , Hidróxidos , Inmunoensayo/métodos , Nanopartículas del Metal , Nanocompuestos , Níquel , Receptores Huérfanos Similares al Receptor Tirosina Quinasa/sangre , Biomarcadores/sangre , Femenino , Humanos , Leucemia Linfocítica Crónica de Células B/diagnóstico , Límite de Detección , Masculino , Reproducibilidad de los Resultados
19.
Biosens Bioelectron ; 178: 113023, 2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33529862

RESUMEN

Ultrasensitive monitoring of cancer cells, especially metastatic ones, has a great interest in human medicine. Despite the early diagnosis of diseases, there is an essential need for any prediction in the severity of side effects for therapeutic outcomes like metastasis. Therefore, the inhibition of cancer cells metastasis to other organs is of utmost importance for cancer suffering patients. In this regard, we developed an electrochemiluminescence (ECL)-based cytosensor for the quantification of metastatic breast cancer cells, namely SKBR-3. Silica-based mesoporous materials have a great potential for application in ECL biosensors due to their high loading capacity and mechanical strength. Herein, a silica-based electrode was prepared via in situ electrosyntheses of mesoporous silica as an environmentally friendly approach. In this protocol, luminol (as luminophore) was combined with chitosan (as attachment biomolecule) to produce a stable lumino-composite film on the electrode surface. At the optimum experimental conditions, the lower limit of quantitation (LLOQ) and linear dynamic range (LDR) were obtained as 20 cells/mL and 20 to 2000 cells/mL, individually. The specificity was desirably examined in the presence of other breast cancer cell lines such as MCF-7 and MDA-MB-231, as a model of early-stage and invasive phases of breast cancer cells. The repeatability was successfully examined for five repetitive measurements and the acceptable relative standard deviation (RSD) was calculated as about 1.6% for 500 cells/mL. As a proof of concept, the presented cytosensor has a high ability to use in clinical laboratories for the detection and separation of metastatic cells via the combination with microfluidic systems.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Mama , Neoplasias de la Mama/diagnóstico , Técnicas Electroquímicas , Humanos , Límite de Detección , Mediciones Luminiscentes , Luminol , Células MCF-7
20.
Bioelectrochemistry ; 137: 107633, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32891010

RESUMEN

Gold nanostars (AuNSs) demonstrate an intense electromagnetic field around tip of branches. In this research, we employed AuNSs-enhanced electrochemiluminescence (ECL) emission from graphitic carbon nitride nanosheets (g-CN nanosheets) to detect CD133 peptide as a cancer stem cell membrane biomarker. In this biosensor, the g-CN nanosheets were decorated with AuNSs (AuNSs@g-CN nanosheets). AuNSs@g-CN nanosheets exhibited strong and stable cathodic ECL emission compared to that of pure g-CN nanosheets. The ECL intensity from the AuNSs@g-CN nanosheets was over 30% higher than that of spherical gold nanoparticles (spherical AuNPs) decorated g-CN nanosheets. The additional ECL enhancement of AuNSs was due to the localized surface plasmon resonance (LSPR) effect located around multiple branch tips of AuNSs. The RSD of ECL curves intensities, obtained from successive potential scans for 10 cycles, were less than 4%, indicating the superior stability of the AuNSs@g-CN nanosheets. Under optimum conditions, the ECL intensity of GCE/AuNSs@g-CN nanosheets/anti-CD133 decreased linearly with CD133 peptide concentration in the range of 0.05-100 ng mL-1. The LOD achieved was 0.257 ng mL-1 (S/N = 3). The applicability of the designed biosensor in real samples was examined through the determination of CD133 peptide in spiked serum samples, from which satisfactory results were obtained.


Asunto(s)
Antígeno AC133/análisis , Biomarcadores de Tumor/análisis , Técnicas Electroquímicas/métodos , Oro/química , Nanopartículas del Metal/química , Células Madre Neoplásicas/patología , Técnicas Biosensibles/métodos , Humanos , Límite de Detección , Luminiscencia , Células Madre Neoplásicas/inmunología , Resonancia por Plasmón de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...