Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Environ Monit Assess ; 195(10): 1219, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37718371

RESUMEN

Twenty surface sediment samples were gathered from Chasma Lake, deciding the radionuclides 137Cs, 226Ra, 228Ra, 232Th, and 40K and their associated hazard indices. The deliberate radionuclide activities of present research have been contrasted with earlier research, and acquired outcomes in the present study are found below the results in the world. The radiation hazard indices following the presence of natural radionuclides in sediment samples were estimated, and the results assigned the values of all the determined radiological indices found inside the worldwide suggested limits. It was concluded from the current review that the sediment of Chashma Lake is safe for construction and agriculture and does not make radiation dangerous to the nearby local area of the lake.


Asunto(s)
Monitoreo del Ambiente , Lagos , Pakistán , Agricultura
2.
Rep Pract Oncol Radiother ; 27(1): 76-85, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35402026

RESUMEN

Background: Several authors investigated a dosimetric impact of leaf width on radiotherapy plan quality subjectively, and concluded that thinner leaf-width multileaf collimators (MLC) are beneficial because of their better coverage of clinically relevant structures. Study aimed to investigate the dosimetric effect of MLC leaf width on volumetric modulated arc therapy plan quality by objective approach. Materials and methods: Twelve of each prostate and head-and-neck patients were planned for volumetric modulated arc therapy (VMAT) treatments for MLC leaf widths of 4 mm and 10 mm. Three different VMAT schemes single-arc, dual-arc and two combined independent single-arcs were optimized. Dose volume histogram and Isodose distribution were used for quantitative and qualitative comparison of the treatment plan, respectively. Dose-volume-indices of the planning target volume, organs at risk and number of delivered monitor units were compared. The 4 mm leaf width being reference over 10 mm and results were noted as statistically significant if p ≤ 0.05 using student t-test. Results: All VMAT schemes for both tumor sites showed a gain in target coverage, similar organs at risk doses and higher monitor units to be delivered, when changing leaf width from 10 mm to 4 mm. The p-values were significant for majority of head-and-neck dose indices. Conclusion: The thinner-leaf MLCs, owing to their better spatial resolution, result in an overall gain for target coverage, while maintaining permissible doses to the organs at risk.

3.
Environ Monit Assess ; 194(3): 223, 2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35217922

RESUMEN

This study is concentrated on the radiological risk assessment of sixteen surface sediment samples recovered from Namal Lake, District Mianwali, Punjab, Pakistan. The activity of 137Cs, 40 K, 226Ra, 228Ra, and 232Th was carried out with the help of a high purity germanium detector (HPGe) in the sediment, varied in the ranges of > 0.02-3.73 ± 1.31, 98.32 ± 21.45-341.02 ± 58.67, 18.34 ± 2.16-34.23 ± 4.34, 1.62 ± .30-2.34 ± .52, and 0.14 ± 0.10-2.34 ± 0.59 Bq kg-1 with average values 0.74 ± 0.29, 237.26 ± 37.97, 25.06 ± 4.74, 1.97 ± 0.39, and 1.73 ± 0.33 Bq kg-1, respectively. The measured concentrations in the current study have been compared with other earlier studies in the world. The data was also used for determining the other useful parameters like radium equivalent activity, absorbed dose rate, annual effective dose rate, and external and internal hazards index to assess the radiological risk assessment for the environment around the study area. The ERICA Tool software was also applied for radiological risk assessment for lake fish due to the radioactivity present in the lake sediments. It was concluded from the results of ERICA tool that the risk quotient in this study is less than one indicating that no toxic effects of radioactivity for Namal Lake fish.


Asunto(s)
Monitoreo de Radiación , Radio (Elemento) , Contaminantes Radiactivos del Suelo , Animales , Lagos , Pakistán , Radioisótopos de Potasio/análisis , Monitoreo de Radiación/métodos , Radio (Elemento)/análisis , Medición de Riesgo , Contaminantes Radiactivos del Suelo/análisis , Espectrometría gamma , Torio/análisis
4.
J Pak Med Assoc ; 71(4): 1093-1099, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34125749

RESUMEN

OBJECTIVE: To evaluate different VMAT planning techniques for a multi-leaf collimator (MLC)providing maximum aperture of 21 × 16 cm². METHODS: A VMAT planning study of nine prostate and nine head-and-neck cancer patients was carried out. The patients were previously treated with Intensity Modulated Radiotherapy (IMRT) technique during 2014-15, at radiation oncology SanBortolo Hospital, Vicenza, Italy. Three VMAT plans for each of prostate and head-and-neck cancer patient were optimized using Pinnacle treatment planning system for 6MV photon beam from ElektaSynergyS®Linac system. Single arc, dual arc and combined two independent-single-arcs were optimized for collimator angle 45°. VMAT treatment planning comparison was made among single-arc dual-arc and combined two independent-single-arcs. The student's t-test (two-sided) with p ≤ 0.05 was applied for significant difference between dose volume indices of plans. RESULTS: All VMAT techniques produced clinically acceptable plans for prostate, while for head-and-neck, DA and ISAs significantly improved target coverage compared to SA. Single arc is sufficient for prostate, while inefficient in case of head-and-neck dose-planning. In spite of having different VMAT optimization approach dual arc and two combined independent-single-arcs provided very similar target coverage, while dual arc improved sparing of organs-at-risk. Similar treatment delivery times were observed for DA and ISAs VMAT techniques. CONCLUSIONS: Single arc is sufficient for prostate, while inefficient in case of head-and-neck dose-planning. Dual arc and two combined independent-single-arcs provided similar PTV coverage, while DA provided better sparing of organs at risk.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia de Intensidad Modulada , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Masculino , Próstata , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
5.
Rep Pract Oncol Radiother ; 23(3): 189-198, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29760593

RESUMEN

AIM: The aim of study was to evaluate the dosimetric effect of collimator-rotation on VMAT plan quality, when using limited aperture multileaf collimator of Elekta Beam Modulator™ providing a maximum aperture of 21 cm × 16 cm. BACKGROUND: The increased use of VMAT technique to deliver IMRT from conventional to very specialized treatments present a challenge in plan optimization. In this study VMAT plans were optimized for prostate and head and neck cancers using Elekta Beam-ModulatorTM, whereas previous studies were reported for conventional Linac aperture. MATERIALS AND METHODS: VMAT plans for nine of each prostate and head-and-neck cancer patients were produced using the 6 MV photon beam for Elekta-SynergyS® Linac using Pinnacle3 treatment planning system. Single arc, dual arc and two combined independent-single arcs were optimized for collimator angles (C) 0°, 90° and 0°-90° (0°-90°; i.e. the first-arc was assigned C0° and second-arc was assigned C90°). A treatment plan comparison was performed among C0°, C90° and C(0°-90°) for single-arc dual-arc and two independent-single-arcs VMAT techniques to evaluate the influence of extreme collimator rotations (C0° and 90°) on VMAT plan quality. Plan evaluation criteria included the target coverage, conformity index, homogeneity index and doses to organs at risk. A 'two-sided student t-test' (p ≤ 0.05) was used to determine if there was a significant difference in dose volume indices of plans. RESULTS: For both prostate and head-and-neck, plan quality at collimator angles C0° and C(0°-90°) was clinically acceptable for all VMAT-techniques, except SA for head-and-neck. Poorer target coverage, higher normal tissue doses and significant p-values were observed for collimator angle 90° when compared with C0° and C(0°-90°). CONCLUSIONS: A collimator rotation of 0° provided significantly better target coverage and sparing of organs-at-risk than a collimator rotation of 90° for all VMAT techniques.

6.
J Radiat Res ; 58(4): 579-590, 2017 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-27974507

RESUMEN

Volumetric-modulated arc therapy (VMAT) is an efficient form of radiotherapy used to deliver intensity-modulated radiotherapy beams. The aim of this study was to investigate the relative insensitivity of VMAT plan quality to gantry angle spacing (GS). Most previous VMAT planning and dosimetric work for GS resolution has been conducted for single arc VMAT. In this work, a quantitative comparison of dose-volume indices (DIs) was made for partial-, single- and double-arc VMAT plans optimized at 2°, 3° and 4° GS, representing a large variation in deliverable multileaf collimator segments. VMAT plans of six prostate cancer and six head-and-neck cancer patients were simulated for an Elekta SynergyS® Linac (Elekta Ltd, Crawley, UK), using the SmartArc™ module of Pinnacle³ TPS, (version 9.2, Philips Healthcare). All optimization techniques generated clinically acceptable VMAT plans, except for the single-arc for the head-and-neck cancer patients. Plan quality was assessed by comparing the DIs for the planning target volume, organs at risk and normal tissue. A GS of 2°, with finest resolution and consequently highest intensity modulation, was considered to be the reference, and this was compared with GS 3° and 4°. The differences between the majority of reference DIs and compared DIs were <2%. The metrics, such as treatment plan optimization time and pretreatment (phantom) dosimetric calculation time, supported the use of a GS of 4°. The ArcCHECK™ phantom-measured dosimetric agreement verifications resulted in a >95.0% passing rate, using the criteria for γ (3%, 3 mm). In conclusion, a GS of 4° is an optimal choice for minimal usage of planning resources without compromise of plan quality.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Relación Dosis-Respuesta en la Radiación , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Masculino , Órganos en Riesgo , Neoplasias de la Próstata/radioterapia
7.
Radiother Oncol ; 122(1): 109-115, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27908453

RESUMEN

PURPOSE: To improve MLC tracking of prostate VMAT plans by dynamic rotation of the collimator to align the MLC leaves with the dominant prostate motion direction. METHODS: For 22 prostate cancer patients, two dual arc VMAT plans were made with (1) fixed collimators (45° and 315°) and (2) a rotating collimator that aligned the MLC leaves with the dominant prostate motion direction (population-based first principal component). The fixed and rotating collimator plan quality was compared using selected dose-volume indices. Next, MLC tracking treatments were simulated with 695 patient-measured prostate traces. The MLC exposure error (under- and overexposed MLC area in beam's eye view) was calculated as a surrogate for the MLC tracking error. Finally, motion including dose reconstruction was performed for 35 motion traces for one patient, and the root-mean-square dose error was compared with the MLC exposure error. RESULTS: Rotating collimator VMAT plans were of similar quality as the fixed collimator plans, but significantly improved MLC tracking with 33% lower MLC exposure errors (p≪0.0001). The reductions in MLC exposure error correlated significantly with dose error reductions. CONCLUSION: Prostate VMAT plans with rotating collimator were of similar quality as fixed collimator plans, but more suitable for MLC tracking with significantly better agreement between planned and delivered dose distributions. MLC tracking for prostate cancer patients can therefore be improved without the requirement of additional efforts or hardware changes.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Humanos , Masculino , Aceleradores de Partículas , Fantasmas de Imagen , Próstata , Estudios Retrospectivos , Rotación
8.
Clin Nurs Res ; 20(2): 135-43, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21612023

RESUMEN

Pulmonary arterial hypertension (PAH) is a complex and rapidly progressing illness with few long-term treatment options to prolong life and improve quality of life. The complexity of the disease predisposes patients to a multitude of symptoms that have an effect on their biopsychosocial well-being. McDonough et al. have taken a qualitative approach to examine the dimensions of PAH symptomology. Using a telephone survey approach, 10 patients were questioned regarding their symptoms. Following coding and categorization of the responses, two main themes were found, "holding back" and redefining life." The primary symptom associated with holding back was breathlessness. This symptom largely governed fears and behaviors associated with subthemes found within this main theme. Breathlessness also featured in the redefining life category; however, practical issues associated with medication and treatment were also assigned importance in this category by the study respondents. Symptoms of anxiety and depression were counteracted in many instances by a positive and sometimes stoic attitude toward the illness. This study presents important foundational information which will help direct further development of theoretical hypothesis related to PAH symptomology, as well as help focus clinical research toward venues that will enhance nursing care of this complex disease.


Asunto(s)
Hipertensión Pulmonar , Hipertensión Pulmonar Primaria Familiar , Humanos , Hipertensión Pulmonar/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA