Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(6)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38544225

RESUMEN

In this paper, surface electromyography (sEMG) is used to gather the activation neural signal from muscles during an indoor rowing exercise. The exercise was performed by professional athletes and amateur non-athletes. The data acquisition and processing are described to obtain a set of parameters: number of cycles, average cycle time, cycle time standard deviation, fatigue time, muscle activation time, and muscle energy. These parameters are used to draw conclusions on common non-athletes' mistakes during exercise for better training advice and a way of statistically distinguishing an athlete from a non-athlete.


Asunto(s)
Músculo Esquelético , Deportes Acuáticos , Humanos , Electromiografía , Músculo Esquelético/fisiología , Ejercicio Físico/fisiología , Atletas , Deportes Acuáticos/fisiología , Hábitos
2.
Artículo en Inglés | MEDLINE | ID: mdl-36554391

RESUMEN

The SARS-CoV-2 virus pandemic has shown that the use of a contact thermometer to verify the elevated body temperature of a suspected person carries a risk of spreading disease. The perfect solution seems to be the use of thermal imaging as a diagnostic method in fever evaluation. The aim of the research is to develop an algorithm for thermovision measurements in fever screening standards in the context of the impact of various weather conditions on the temperature of people entering the public institution. Each examined person had two thermal images of the face-AP and lateral projection. Using a T1020 FLIR thermal camera with a resolution of 1024 × 768 pixels; the mean temperature was measured from the area of the forehead, the maximum forehead, the corners of the eyes, the inside of the mouth and the external auditory canal temperature. On the other hand, using classic contact thermometers, the temperature in the armpit and ear was measured. The obtained preliminary results showed very strong and positive correlations between the temperature in the ear measured with an ear thermometer and the maximum, minimum and average forehead temperature. These correlations oscillate at approximately r = 0.6, but the highest value of Spearman coefficient was obtained for the mean temperature of the forehead. Moreover, high correlations were also obtained between the temperature in the ear, measured with an ear thermometer, and the maximum temperature in the corners of the eyes and in the ear, measured with a thermal imaging camera. These values were, respectively, r = 0.54, r = 0.65. In summarizing, remote body temperature measurement taken with a thermal camera can be useful in the assessment of the body's core temperature.


Asunto(s)
COVID-19 , Pandemias , Humanos , Temperatura , COVID-19/diagnóstico , COVID-19/epidemiología , SARS-CoV-2 , Fiebre/diagnóstico , Temperatura Corporal , Boca
3.
J Therm Biol ; 99: 103013, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34420643

RESUMEN

The impact of participation in the ultramarathon on the health and mental and physical condition is very complex. Undoubtedly, exercise brings many benefits but also involves health risks. Especially such an extreme effort as the one associated with finishing the ultramarathon run, can be dangerous to the health of the runner. With the variety of possible biomarkers of excessive fatigue that threaten health and life, a question arises which of them are the best and which should be considered in amateur long-distance runners showing particularly high individual variability. In this study differential scanning calorimetry (DSC) has been applied to show the overall effect of the 12-h run on blood sera of participants. Serum samples were obtained from the blood of ten male amateur long-distance runners, collected before and immediately after the run. Distinct changes in the shape of DSC curves have been observed for serum after finishing the run relative to pre-race serum. Statistically significant differences between stages "before" and "after" ultramarathon running have been found for parameters of the endothermic transition associated with denaturation of serum proteins. An increase in the temperature (from 70.9 ± 0.9 to 75.8 ± 2.9 °C) and excess heat capacity (from 0.859 ± 0.201 to 1.102 ± 0.226 Jg-1 °C-1) at peak maximum, the enthalpy of serum denaturation (from 18.55 ± 6.52 to 22.08 ± 5.61 Jg-1) and the first moment of the thermal transition with respect to the temperature (from the value of 67.0 ± 2.1 to 72.6 ± 2.1 °C) has been observed. These results show a clear impact of running an ultramarathon on the participant's blood serum.


Asunto(s)
Biomarcadores/sangre , Carrera de Maratón/fisiología , Atletas , Rastreo Diferencial de Calorimetría , Humanos , Masculino , Persona de Mediana Edad