Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 95(8): 4059-4066, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36800441

RESUMEN

Characterization of charge heterogeneity is an essential pillar for pharmaceutical development and quality control of therapeutic monoclonal antibodies (mAbs). The highly selective and commonly applied capillary zone electrophoresis (CZE) method containing high amounts of ε-aminocaproic acid (EACA) provides a detailed and robust charge heterogeneity profile of intact mAb variants. Nevertheless, the exact location of protein modifications within these charge profiles remains ambiguous. Electrospray ionization mass spectrometry (ESI-MS) is a promising tool for this purpose; however, EACA is incompatible with electrospray. In this context, we present a two-dimensional CZE-CZE-MS system to combine efficient charge variant separation of intact mAbs with subsequent peptide analysis after in-capillary digestion of selected charge variants. The first dimension is based on a generic CZE(EACA) method in a fused silica capillary. In the second dimension, a neutral-coated capillary is used for in-capillary reduction and digestion with Tris(2-carboxyethyl)phosphine (TCEP) and pepsin, followed by CZE separation and MS/MS-characterization of the resulting peptides. The setup is demonstrated using stressed and nonstressed mAbs where peaks of basic, main, and acidic variants were transferred in a heart-cut fashion, digested, and characterized on the peptide level. Sequence coverages of more than 90% were obtained for heavy chain (HC) and light chain (LC) for four different mAbs, including low-abundance variants (<2% of the main peak). Frequently observed modifications (deamidation, oxidation, etc.) could be detected and localized. This study demonstrates a proof-of-concept for identification and localization of protein modifications from CZE charge heterogeneity profiles and, in this way, is expected to support the development and quality control testing of protein pharmaceuticals.


Asunto(s)
Anticuerpos Monoclonales , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Anticuerpos Monoclonales/química , Péptidos , Electroforesis Capilar/métodos , Digestión
2.
Electrophoresis ; 44(5-6): 540-548, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36148605

RESUMEN

Imaged capillary isoelectric focusing (iCIEF) has emerged as an important technique for therapeutic monoclonal antibody (mAb) charge heterogeneity analysis in the biopharmaceutical context, providing imaged detection and quantitation by UV without a mobilization step. Besides quantitation, the characterization of separated charge variants ideally directly by online electrospray ionization-mass spectrometry (ESI-MS) is crucial to ensure product quality, safety, and efficacy. Straightforward direct iCIEF-MS coupling combining high separation efficiency and quantitative results of iCIEF with the characterization power of MS enables deep characterization of mAb charge variants. A short technical setup and optimized methodical parameters (30 nl/min mobilization rate, 2%-4% ampholyte concentration, 0.5-2 mg/ml sample concentration) allow successful mAb charge variant peak assignment from iCIEF to MS. Despite a loss of separation resolution during the transfer, separated intact mAb charge variants, including deamidation as well as major and minor glycoforms even from low abundant charge variants, could be characterized by online ESI-MS with high precision. The presented setup provides a large potential for mAb charge heterogeneity characterization in biopharmaceutical applications.


Asunto(s)
Anticuerpos Monoclonales , Productos Biológicos , Anticuerpos Monoclonales/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Focalización Isoeléctrica/métodos , Focalización Isoeléctrica Capilar
3.
Artículo en Inglés | MEDLINE | ID: mdl-35026663

RESUMEN

Methionine is a common excipient used in therapeutic protein liquid formulations as stabilizer and antioxidant. The oxidation of methionine to methionine sulfoxide can be regarded as a sensitive marker of oxidative stress for drug product storage conditions. In this study, a sensitive HPLC method for the quantification of methionine sulfoxide in formulated protein product was developed and qualified according to regulatory requirements using a SIELC® Primesep 100 column with UV detection. The separation involves a mixed-mode mechanism including reversed phase and cationic exchange modalities. The operating range of the method was established between 1 µM and 35 µM of methionine sulfoxide. In this testing range, the method was shown to be linear (R2 > 0.99), accurate (Recovery 92.9 - 103.6%, average recovery = 99.8 ± 1.4%) and precise (intermediate precision at LoQ, CV = 2.9%). The developed test system was successfully applied to study the effects of temperature and storage conditions on methionine sulfoxide formation in complex therapeutic antibody formulations.


Asunto(s)
Excipientes/química , Metionina/análogos & derivados , Biomarcadores/análisis , Cromatografía Líquida de Alta Presión/métodos , Límite de Detección , Modelos Lineales , Metionina/análisis , Metionina/química , Oxidación-Reducción , Reproducibilidad de los Resultados
4.
J Pharm Biomed Anal ; 201: 114089, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-33940498

RESUMEN

Size heterogeneity analysis by capillary sieving electrophoresis utilizing sodium dodecyl sulfate (CE(SDS)) with optical detection is a major method applied for release and stability testing of monoclonal antibodies (mAbs) in biopharmaceutical applications. Identification of mAb-fragments and impurities observed with CE(SDS) is of outstanding importance for the assessment of critical quality attributes and development of the analytical control system. Mass spectrometric (MS) detection is a powerful tool for protein identification and characterization. Unfortunately, CE(SDS) is incompatible with online MS-hyphenation due to strong ionization suppression of SDS and other separation buffer components. Here, we present a comprehensive platform for full characterization of individual CE(SDS)-separated peaks by CE(SDS)-capillary zone electrophoresis-top-down-MS. The peak of interest is transferred from the first to the second dimension via an 8-port valve to remove MS-incompatible components. Full characterization of mAb byproducts is performed by intact mass determination and fragmentation by electron transfer dissociation, higher-energy collisional dissociation, and ultraviolet photodissociation. This enables online determination of intact mass as well as sequence verification of individual CE(SDS)-separated peaks simultaneously. A more substantiated characterization of unknown CE(SDS) peaks by exact localization of modifications without prior digestion is facilitated. High sensitivity is demonstrated by successful mass and sequence verification of low abundant, unknown CE(SDS) peaks from two stressed mAb samples. Good fragmentation coverages are obtained by MS2, enabling unequivocal identification of these mAb-fragments. Also, the differentiation of reduced/non-reduced intra-protein disulfide bonds is demonstrated. In summary, a reliable and unambiguous online MS2 identification of unknown compounds of low-abundant individual CE(SDS) peaks is enabled.


Asunto(s)
Anticuerpos Monoclonales , Electroforesis Capilar , Fragmentos de Inmunoglobulinas , Espectrometría de Masas , Dodecil Sulfato de Sodio
5.
Electrophoresis ; 42(11): 1209-1216, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33651405

RESUMEN

Oxidative damage of biopharmaceuticals during manufacturing and storage is a key concern throughout pharmaceutical development. However, few simple and robust analytical methods are available for the determination of oxidation sites. Here, the potential of affinity capillary electrophoresis (ACE) in the separation of proteins with oxidized methionine (Met) residues is shown. Silver(I) and gold(I) ions have the attribute to selectively form complexes with thioethers over sulfoxides. The addition of these ions to the BGE leads to a selective complexation of Met residues and, thus, to a change of charge allowing separation of species according to the different oxidation states of Met. The mechanisms of these interactions are discussed and binding constants for peptides containing Met with silver(I) are calculated. Additionally, the proposed method can be used as an indicator of oxidative stress in large proteins. The presented technique is easily accessible, economical, and has rapid analysis times, adding new approaches to the analytical toolbox of Met sulfoxide detection.


Asunto(s)
Oro , Metionina , Proteínas , Plata , Cationes , Electroforesis Capilar , Metionina/química , Oxidación-Reducción , Proteínas/química
6.
Electrophoresis ; 42(4): 374-380, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32762042

RESUMEN

Capillary sieving electrophoresis utilizing SDS (CE(SDS)) is one of the most applied methods for the analysis of antibody (mAb) size heterogeneity in the biopharmaceutical industry. Inadequate peak identification of observed protein fragments is still a major issue. In a recent publication, we introduced an electrophoretic 2D system, enabling online mass spectrometric detection of generic CE(SDS) separated peaks and identification of several mAb fragments. However, an improvement regarding system stability and handling of the approach was desired. Here, we introduce a novel 8-port valve in conjunction with an optimized decomplexation strategy. The valve contains four sample loops with increased distances between the separation dimensions. Thus, successively coinjection of solvent and cationic surfactant without any additional detector in the second dimension is enabled, simplifying the decomplexation strategy. Removal efficiency was optimized by testing different volumes of solvents as presample and cationic surfactant as postsample zone. 2D measurements of the light and heavy chain of the reduced NIST mAb with the 8-port valve and the optimized decomplexation strategy demonstrates the increased robustness of the system. The presented novel set-up is a step toward routine application of CE(SDS)-CZE-MS for impurity characterization of proteins in the biopharmaceutical field.


Asunto(s)
Electroforesis Capilar/métodos , Espectrometría de Masas/métodos , Nanotecnología/instrumentación , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química , Electroforesis Capilar/instrumentación , Diseño de Equipo , Cadenas Pesadas de Inmunoglobulina/análisis , Cadenas Pesadas de Inmunoglobulina/química , Cadenas Ligeras de Inmunoglobulina/análisis , Cadenas Ligeras de Inmunoglobulina/química , Espectrometría de Masas/instrumentación
7.
Anal Bioanal Chem ; 411(27): 7197-7206, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31616969

RESUMEN

Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) is the fundamental technique for protein separation by size. Applying this technology in capillary format, gaining high separation efficiency in a more automated way, is a key technology for size separation of proteins in the biopharmaceutical industry. However, unequivocal identification by online mass spectrometry (MS) is impossible so far, due to strong interference in the electrospray process by SDS and other components of the SDS-MW separation gel buffer. Here, a heart-cut two-dimensional electrophoretic separation system applying an electrically isolated valve with an internal loop of 20 nL is presented. The peak of interest in the CE (SDS) separation is transferred to the CZE-MS, where electrospray-interfering substances of the SDS-MW gel are separated prior to online electrospray ionization mass spectrometry. An online SDS removal strategy for decomplexing the protein-SDS complex is implemented in the second dimension, consisting of the co-injection of organic solvent and cationic surfactant. This online CE (SDS)-CZE-MS system allows MS characterization of proteoforms separated in generic CE (SDS), gaining additional separation in the CZE and detailed MS information. In general, the system can be applied to all kinds of proteins separated by CE (SDS). Here, we present results of the CE (SDS)-CZE-MS system on the analysis of several biopharmaceutically relevant antibody impurities and fragments. Additionally, the versatile application spectrum of the system is demonstrated by the analysis of extracted proteins from soybean flour. The online hyphenation of CE (SDS) resolving power and MS identification capabilities will be a powerful tool for protein and mAb characterization. Graphical abstract Two-dimensional capillary electrophoresis system hyphenated with mass spectrometry for the characterization of CE (SDS)-separated proteins. As first dimension, a generic and high MS-interfering CE (SDS) separation is performed for size separation. After heart-cut transfer of the unknown CE (SDS) protein peak, via a four-port nanoliter valve to a volatile electrolyte system as second dimension, interference-free mass spectrometric data of separated mAb fragments and soybean proteins are obtained.


Asunto(s)
Electroforesis Capilar/instrumentación , Glycine max/química , Proteínas de Soja/aislamiento & purificación , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Electroforesis en Gel de Poliacrilamida , Diseño de Equipo , Dodecil Sulfato de Sodio/química , Proteínas de Soja/análisis
8.
Electrophoresis ; 40(22): 3014-3022, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31560789

RESUMEN

Charge heterogeneity profiling is important for the quality control (QC) of biopharmaceuticals. Because of the increasing complexity of these therapeutic entities [1], the development of alternative analytical techniques is needed. In this work, flow-through partial-filling affinity capillary electrophoresis (FTPFACE) has been established as a method for the analysis of a mixture of two similar monoclonal antibodies (mAbs). The addition of a specific ligand results in the complexation of one mAb in the co-formulation, thus changing its migration time in the electric field. This allows the characterization of the charged variants of the non-shifted mAb without interferences. Adsorption of proteins to the inner capillary wall has been circumvented by rinsing with guanidine hydrochloride before each injection. The presented FTPFACE approach requires only very small amounts of ligands and provides complete comparability with a standard CZE of a single mAb.


Asunto(s)
Anticuerpos Monoclonales/análisis , Productos Biológicos/análisis , Electroforesis Capilar/métodos , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/aislamiento & purificación , Productos Biológicos/química , Productos Biológicos/aislamiento & purificación
9.
Electrophoresis ; 38(24): 3136-3146, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28887890

RESUMEN

CZE is a well-established technique for charge heterogeneity testing of biopharmaceuticals. It is based on the differences between the ratios of net charge and hydrodynamic radius. In an extensive intercompany study, it was recently shown that CZE is very robust and can be easily implemented in labs that did not perform it before. However, individual characteristics of some examined proteins resulted in suboptimal resolution. Therefore, enhanced method development principles were applied here to investigate possibilities for further method optimization. For this purpose, a high number of different method parameters was evaluated with the aim to improve CZE separation. For the relevant parameters, design of experiments (DoE) models were generated and optimized in several ways for different sets of responses like resolution, peak width and number of peaks. In spite of product specific DoE optimization it was found that the resulting combination of optimized parameters did result in significant improvement of separation for 13 out of 16 different antibodies and other molecule formats. These results clearly demonstrate generic applicability of the optimized CZE method. Adaptation to individual molecular properties may sometimes still be required in order to achieve optimal separation but the set screws discussed in this study [mainly pH, identity of the polymer additive (HPC versus HPMC) and the concentrations of additives like acetonitrile, butanolamine and TETA] are expected to significantly reduce the effort for specific optimization.


Asunto(s)
Anticuerpos Monoclonales/análisis , Electroforesis Capilar/métodos , Electroforesis Capilar/normas , Proyectos de Investigación
10.
Anal Bioanal Chem ; 409(26): 6057-6067, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28801824

RESUMEN

Capillary zone electrophoresis (CZE) is a powerful tool that is progressively being applied for the separation of monoclonal antibody (mAb) charge variants. Mass spectrometry (MS) is the desired detection method concerning identification of mAb variants. In biopharmaceutical applications, there exist optimized and validated electrolyte systems for mAb variant quantification. However, these electrolytes interfere greatly with the electrospray ionization (ESI) process. Here, a heart-cut CZE-CZE-MS setup with an implemented mechanical four-port valve interface was developed that used a generic ε-aminocaproic acid based background electrolyte in the first dimension and acetic acid in the second dimension. Interference-free, highly precise mass data (deviation less than 1 Da) of charge variants of trastuzumab, acting as model mAb system, were achieved. The mass accuracy obtained (low parts per million range) is discussed regarding both measured and calculated masses. Deamidation was detected for the intact model antibody, and related mass differences were significantly confirmed on the deglycosylated level. The CZE-CZE-MS setup is expected to be applicable to a variety of antibodies and electrolyte systems. Thus, it has the potential to become a compelling tool for MS characterization of antibody variants separated in ESI-interfering electrolytes. Graphical Abstract Two-dimensional capillary zone electrophoresis mass spectrometry for the characterization of intact monoclonal antibody (mAb) charge variants. A generic, but highly electrospray-interfering electrolyte system was used as first dimension for mAb charge variant separation and coupled to a volatile electrolyte system as second dimension via a four-port nanoliter valve. In this way, interference-free and precise mass spectrometric data of separated mAb charge variants, including deamidation products, were obtained.


Asunto(s)
Antineoplásicos Inmunológicos/química , Electroforesis Capilar/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Trastuzumab/química , Amidas/análisis , Ácido Aminocaproico/química , Anticuerpos Monoclonales/química , Electrólitos/química , Electroforesis Capilar/instrumentación , Diseño de Equipo , Glicosilación , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Electricidad Estática
11.
Electrophoresis ; 38(7): 1044-1052, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28008632

RESUMEN

Capillary electrophoresis is an important technique for the characterization of monoclonal antibodies (mAbs), especially in the pharmaceutical context. However, identification is difficult as upscaling and hyphenation of used methods directly to mass spectrometry is often not possible due to separation medium components that are incompatible with MS detection. Here a CE-MS method for the analysis of mAbs is presented analyzing SDS-complexed samples. To obtain narrow and intensive peaks of SDS-treated antibodies, an in-capillary strategy was developed based on the co-injection of positively charged surfactants and methanol as organic solvent. For samples containing 0.2% (v/v) of SDS, recovered MS peak intensities up to 97 and 95% were achieved using cetyltrimethylammonium bromide or benzalkonium chloride, respectively. Successful removal of SDS was shown in neutral coated capillaries but also in a capillary with a positively charged coating applying reversed polarity. The usefulness of this in-capillary strategy was demonstrated also for other proteins and for antibodies dissolved in up to 10% v/v SDS solution, and in other SDS-containing matrices, including the sieving matrix used in a standard CE-SDS method and gel-buffers applied in SDS-PAGE methods. The developed CE-MS approaches enable fast and reproducible characterization of SDS-complexed antibodies.


Asunto(s)
Anticuerpos Monoclonales/análisis , Electroforesis Capilar/métodos , Espectrometría de Masas/métodos , Dodecil Sulfato de Sodio/aislamiento & purificación , Reproducibilidad de los Resultados , Dodecil Sulfato de Sodio/química
12.
J Chromatogr B Analyt Technol Biomed Life Sci ; 983-984: 101-10, 2015 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-25637812

RESUMEN

Within pharmaceutical industry charge heterogeneity testing of biopharmaceuticals has to be reproducible and fast. It should pass method validation according to ICH Q2. Classical approaches for the analysis of the charge heterogeneity of biopharmaceuticals are ion exchange chromatography (IEC) and isoelectric focusing (IEF). As an alternative approach, also capillary zone electrophoresis (CZE) was expected to allow reliable charge heterogeneity profiling by separation according to the analyte's net charge and hydrodynamic radius. Aim of this study was to assess if CZE possesses all of the required features. Therefore, beside lab internal validation of this method also an international cross company study was organized. It was shown that CZE is applicable across a broad pI range between 7.4 and 9.5. The coefficient of correlation was above 0.99 which demonstrated linearity. Precision by repeatability was around 1% (maximum relative standard deviation per level) and accuracy by recovery was around 100% (mean recovery per level). Accuracy was further verified by direct comparison of IEC, IEF and CZE, which in this case showed comparable %CPA results for all three methods. However, best resolution for the investigated MAb was obtained with CZE. In dependence on sample concentration the detection limit was between 1 and 3%. Within the intercompany study for CZE the same stressed and non-stressed samples were analyzed in each of the 11 participating labs. The finally obtained dataset contained more than 1000 separations which provided an extended dataset for further statistical evaluation. Among the different labs no significant differences between the peak profiles were observed. Mean driver for dropouts in quantitative evaluation was linked to the performance of some participating labs while the impact of the method performance was negligible. In comparison to a 50cm capillary there was a slightly better separation of impurities and drug substance related compounds with a 30cm capillary which demonstrates that an increased stability indicating potential can be combined with the increased separation velocity and high throughput capability of a shorter capillary. Separation can be performed in as little as approx. 3min allowing high throughput applications. The intercompany study delivered precise results without explicit training of the participating labs in the method prior to the study (standard deviations in the range of 1%). It was demonstrated that CZE is an alternative platform technology for the charge heterogeneity testing of antibodies in the pharmaceutical industry.


Asunto(s)
Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química , Electroforesis Capilar/métodos , Cromatografía por Intercambio Iónico , Concentración de Iones de Hidrógeno , Focalización Isoeléctrica , Reproducibilidad de los Resultados
13.
J Sep Sci ; 35(22): 3124-9, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23065998

RESUMEN

An international team including 12 laboratories from 11 independent biopharmaceutical companies in the United States and Switzerland was formed to evaluate the precision and robustness of imaged capillary isoelectric focusing for the charge heterogeneity analysis of monoclonal antibodies. The different laboratories determined the apparent pI and the relative distribution of the charged isoforms for a representative monoclonal antibody sample using the same capillary isoelectric focusing assay. Statistical evaluation of the data was performed to determine within and between laboratory consistencies and outlying information. The apparent pI data generated for each charged variant peak showed very good precision between laboratories with RSD values of less than 0.8%. Similarly, the RSD for the therapeutic monoclonal antibody charged variants percent peak area values are less than 11% across different laboratories using different analyst, different lots of ampholytes and multiple instruments. These results validate the appropriate use of imaged capillary isoelectric focusing in the biopharmaceutical industry in support of process development and regulatory submissions of therapeutic antibodies.


Asunto(s)
Anticuerpos Monoclonales/análisis , Electroforesis Capilar/métodos , Focalización Isoeléctrica/métodos , Laboratorios/normas , Electroforesis Capilar/normas , Humanos , Focalización Isoeléctrica/normas , Isoformas de Proteínas/análisis , Suiza
14.
Electrophoresis ; 30(9): 1579-86, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19425006

RESUMEN

Recently, several therapeutic double-stranded (ds) oligonucleotides (ODNs) are in pharmaceutical development. During quality control, these therapeutic molecules have to be characterized with respect to their identity, their content and their impurity profile. It follows that the ds molecule as well as its process- and product-related impurities have to be quantified. The single strands are considered as process as well as product-related impurities in the ds drug substance. Applying well known, conventional, single-base resolution CE-CGE systems developed for the quality control of single-stranded antisense ODNs in the early 1990s, it turned out that the ds ODNs under investigation are migrating in broad, splitted peaks between the peaks reaction zones are observed. It follows that the quantification of the single strands in the drug substance as well as quantification of other product-related impurities, e.g. n-1; n-2 (loss of one and two bases (n), respectively) etc., are not possible without adaptation of the test system. The paper shows how the test system was adjusted in order to determine single-stranded strands as well as ds strands next to each other quantitatively in the ds drug substance under investigation.


Asunto(s)
ADN/química , Electroforesis Capilar/métodos , Conformación de Ácido Nucleico , Oligonucleótidos/análisis , Animales , Cationes/química , ADN/análisis , ADN/sangre , Modelos Químicos , Oligonucleótidos/química , Ratas
15.
Electrophoresis ; 28(20): 3625-38, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17941130

RESUMEN

Two robust chiral standard separation systems were developed for the analysis of the chiral purity of chemically different model compounds applied in homogeneous asymmetric hydrogenation catalysis. Sulfated CDs were used as chiral selectors as they allow the analysis of neutral, acidic as well as basic compounds in the same electrophoretic system. Poorly water-soluble amines were dissolved in different organic solvent/buffer mixtures. Reproducibly, depending on the amount of organic solvent in the sample solution, peak splitting occurred and/or more peaks than expected were observed, implying impure model compounds. The dependence of the "chiral purity" on experimental parameters, e.g., kind and amount of sample solvent, length of injection plug, inner surface modification of the capillary, kind of sulfated CD, hydrophobicity, and basicity of the analytes, etc. was investigated. It is gathered that different equilibrium constants of the strong binding basic analytes and highly sulfated CD complex in the organic phase of the injection plug and the aqueous electrolyte phase are resulting in two different mobility zones for each enantiomer. It follows that each enantiomer is showing two peaks instead of one. Experimental strategies are shown to avoid these peak splitting/artificial impurity effects and obtain the "real" chiral purity picture of the samples.


Asunto(s)
Ciclodextrinas/química , Electroforesis Capilar/métodos , Compuestos Orgánicos/química , Solventes/química , Sulfatos/química , Ciclodextrinas/aislamiento & purificación , Metanol , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Solubilidad , Estereoisomerismo
16.
J Chromatogr A ; 982(2): 275-83, 2002 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-12489884

RESUMEN

Affinity capillary electrophoresis using mobility-shift analysis was utilized to characterize the binding of peptide ligands to cyclophilins, which are members of the enzyme family of peptidyl-prolyl cis/trans isomerases. Peptides derived from the human immunodeficiency virus capsid protein p24 exhibited different affinities to the isoenzymes cyclophilin18 and cyclophilin20. For the interaction of the peptide hormone bradykinin with cyclophilin18, a dissociation constant of 1.4 +/- 0.1 mM was determined. Finally, the affinity of cyclophilin20 to peptides from a cellulose-bound peptide library scanning the sequence of Drosophila melanogaster protein cappuccino was investigated. The affinities of selected peptides to cyclophilin20 and a green fluorescent fusion protein with cyclophilin20 were compared.


Asunto(s)
Ciclofilinas/química , Electroforesis Capilar/métodos , Oligopéptidos/química , Prolina/química , Secuencia de Aminoácidos , Animales , Sitios de Unión , Bradiquinina/química , Bradiquinina/metabolismo , Ciclofilinas/metabolismo , Proteínas de Drosophila/química , Proteína p24 del Núcleo del VIH/química , Proteína p24 del Núcleo del VIH/metabolismo , Oligopéptidos/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...