Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39049513

RESUMEN

PURPOSE: This study investigated the effect of different fluoroscopy settings on the accuracy of locating Schottle's point during medial patellofemoral ligament (MPFL) reconstruction. METHODS: The centre of the MPFL femoral footprint was identified and marked on 44 dry femurs. Two standard true lateral knee fluoroscopic images were obtained: (1) medial to lateral (ML) and (2) lateral to medial (LM). The deviation between the anatomically determined MPFL femoral footprint and the fluoroscopically identified point was measured on both fluoroscopic images. An 'acceptable tunnel location' was defined as within a 5- or 7-mm margin of error from the anatomic MPFL footprint. Distal femoral morphometric dimensions were also measured using digital calipers. Statistical analysis determined discrepancies between techniques and their relation to femoral morphometry. RESULTS: The LM view yielded a significantly smaller distance between the anatomical MPFL footprint and Schottle's point compared to the ML view (3.2 ± 1.5 vs. 4.5 ± 2.1 mm, p < 0.001). The LM view achieved acceptable tunnel locations, meeting the 5-mm error criterion in 90.9% of cases, while the ML view achieved 65.9% (p < 0.001). Both views yielded acceptable tunnel locations at similar rates using the 7-mm error criterion (n.s.). The anatomic MPFL footprint was displaced towards the anterior and proximal location in the ML view in reference to the Schottle point. No correlation was observed between any of the morphometric measurements and the deviations. CONCLUSIONS: This study demonstrated that using the LM fluoroscopic view improves the accuracy of femoral tunnel placement when identifying the MPFL footprint via the Schottle technique. Adopting the LM view in surgical practice will help surgeons locate the anatomical femoral footprint accurately, replicating the native MPFL and enhancing clinical outcomes. LEVEL OF EVIDENCE: Level 4, cadaveric study.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38359865

RESUMEN

OBJECTIVE: This study aimed to test whether palmaris longus tendon (PLT) length and thickness can be predicted from simple anthropometric measurements. MATERIALS AND METHODS: 120 healthy volunteers with bilateral PL muscles were enrolled in this prospective study. PLT length and thickness were measured by ultrasonographic examination. Anthropometric measurements included body height, weight, forearm length, and wrist circumference. Correlation, linear regression, and Bland-Altman plot were used for analysis. RESULTS: The mean PLT length and thickness were 10.8±1.4 cm and 4.0±0.9 mm, respectively. Body height and PLT length had a moderate positive correlation (r:0.407, p:0.001), and forearm length and PLT thickness had a weak positive correlation (r:0.229, p:0.001). The regression analysis showed that body height was the best predictor for PLT length, and forearm length was the best predictor for PLT thickness. The regression equations were as follows: PLT length=0.276+(0.062×height) (r2=0.165, p<0.001) and PLT thickness=1.373+(0.108×forearm length) (r2=0.052, p<0.001). The predicted PLT lengths and thicknesses were calculated using these regression formulas and compared with the actual thicknesses and lengths using the Bland-Altman plot. The upper and lower limits of agreement (95% CI) ranged from -2.54 cm to 2.51 cm for actual PLT length and predicted PLT length and from -1.76 mm to 1.74 mm for actual PLT thickness and predicted PLT thickness in the Bland-Altman plot with a weak agreement and proportional bias. CONCLUSIONS: These findings indicate that height and forearm length have limited accuracy in predicting PLT length and thickness. The preoperative ultrasonographic examination can provide valuable assistance, particularly in cases that require grafts with precise length and thickness requirements.

3.
Arch Orthop Trauma Surg ; 144(4): 1675-1684, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38400901

RESUMEN

PURPOSE: The success of medial patellofemoral ligament (MPFL) reconstruction is closely linked to the precise positioning of the femoral tunnel. Intraoperative fluoroscopy is commonly utilized to identify the MPFL footprint. This study aimed to ascertain the most accurate fluoroscopic method among the five previously described methods used to determine the MPFL femoral footprint. MATERIALS AND METHODS: Using 44 well-preserved dry femur bones, the MPFL femoral insertion site was demarcated using anatomical bony landmarks, namely the center of the saddle sulcus between the medial epicondyle, adductor tubercle and gastrocnemius tubercle. Fluoroscopic true lateral knee images were acquired and measurements taken, referencing established methods by Schottle et al., Redfern et al., Wijdicks et al., Barnett et al., and Kaipel et al. The distance between anatomic and fluoroscopic MPFL footprints was then measured on digital fluoroscopic images. The accuracy of the locations was compared using a margin of error of 5 and 7 mm. RESULTS: The Schottle method consistently emerged superior, showcasing the smallest mean distance (3.2 ± 1.2 mm) between the anatomic and radiographic MPFL footprints and a high in-point detection rate of 90.9% under 5 mm criteria. While the Redfern method displayed perfect accuracy (100%) within the 7 mm criteria, the Schottle method also performed 97.7% accuracy. CONCLUSIONS: For intraoperative identification of the MPFL footprint using fluoroscopy, the Schottle method is the most consistent and accurate among the assessed methods. Thus, its accuracy in detecting the MPFL footprint makes it recommended for MPFLR to ensure optimal outcomes. LEVEL OF EVIDENCE: Level IV, cadaveric study.


Asunto(s)
Articulación Patelofemoral , Humanos , Articulación Patelofemoral/cirugía , Fémur/diagnóstico por imagen , Fémur/cirugía , Articulación de la Rodilla , Fluoroscopía/métodos , Ligamentos Articulares/cirugía
4.
J Obstet Gynaecol ; 43(1): 2171777, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36708520

RESUMEN

The aim of this study was to define the actual rate of the traction needed and the balloon catheter or tenaculum requirement for hysterosalpingography (HSG) examinations, and to investigate the correlation between pain scores with the type of traction, operator, parity or the type of infertility. 788 patients undergoing HSG participated in the trial. The HSG examinations were completed in 58% of the patients (458) without any traction. Traction was needed in 42% of patients, those with the balloon catheter in 26.9%, and those with the tenaculum only at 15%. Patients with balloon catheter traction had similar pain scores to those using tenaculum traction. The pain scores changed according to the operator. HSG examinations should be performed step-by-step and the need for traction evaluated during the procedure.IMPACT STATEMENTWhat is already known on this subject? HSG is a technique to evaluate fallopian tube patency and other potential intrauterine pathology in infertile women.What do the results of this study add? Traction was not needed in more than half of the HSG examinations. The pain due to the balloon catheter and tenaculum is similar.What the implications are of these findings for clinical practice and/or further research? HSG examinations should be performed step-by-step by checking the need for traction. Traction with the balloon catheter prevents the uterine spasm, infection and bleeding complications during or after the HSG.


Asunto(s)
Histerosalpingografía , Infertilidad Femenina , Femenino , Humanos , Embarazo , Catéteres , Trompas Uterinas/patología , Histerosalpingografía/métodos , Infertilidad Femenina/etiología , Infertilidad Femenina/terapia , Infertilidad Femenina/patología , Dolor
5.
Lasers Med Sci ; 37(4): 2227-2237, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35022874

RESUMEN

To compare the effects of low level laser therapy (LLLT) and corticosteroid injection in patients with moderate carpal tunnel syndrome (CTS). Eighty-seven patients (143 wrists) with moderate CTS were randomized to the corticosteroid or LLLT groups. 40 mg of triamcinolone acetate solution was applied to carpal tunnel of 44 patients (74 wrist). LLLT was applied to 43 patients (70 wrist) five times a week, for a total of 15 sessions (fluence of 6 j/cm2 for 1 min per point at a wavelength of 830 nm). Outcome measures were numbness and pain, QuickDASH questionnaire, grasping tests, Tinel and Phalen tests, electrophysiological tests and MRI evaluations, which were tested at the baseline and 1st and 6th months after the treatment. Eighty patients (133 wrists) completed the study at the end of 6 months. VAS and Quick DASH scores were better in the corticosteroid group in the 1st month, but there were no significant differences between groups in the 6th month. Phalen and Tinel tests, strength tests, and motor distal latency improved significantly and similarly in both groups at the 1st and 6th months. Sensory distal latency and sensory nerve conduction velocity showed significant improvements in the 1st and 6th months only in the corticosteroid group. In both groups, median nerve intensity rate and palmary spring rate improved significantly after the treatment. Based on this study, corticosteroid injection and LLLT groups showed statistically significant difference at the 1st month (short-term), whereas there was no significant difference at the 6th month (intermediate-term).


Asunto(s)
Síndrome del Túnel Carpiano , Terapia por Luz de Baja Intensidad , Corticoesteroides/uso terapéutico , Síndrome del Túnel Carpiano/tratamiento farmacológico , Síndrome del Túnel Carpiano/radioterapia , Método Doble Ciego , Humanos , Nervio Mediano , Conducción Nerviosa , Estudios Prospectivos , Resultado del Tratamiento
6.
J Comput Assist Tomogr ; 42(3): 423-428, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29189402

RESUMEN

PURPOSE: The aims of this study were to evaluate using testicle apparent diffusion coefficient (ADC) values in patients with varicocele and compare them with those of healthy individuals, to identify an optimal ADC threshold level to predict abnormal semen analysis using diffusion-weighted imaging. MATERIALS AND METHODS: Thirty-one patients with the diagnosis of varicocele and 20 healthy controls were enrolled in the study. All subjects underwent testicle diffusion-weighted imaging at b values of 0, 400, and 800 s/mm and semen analysis. Student t tests were used to compare continuous variables between 2 groups. Testicle ADC values were correlated with semen analysis parameters. The relationship between ADC values and impaired semen analysis parameters was evaluated using Pearson correlation coefficient analysis. Receiver operating characteristic curves were formed. Cut-off values for ADC, sensitivity, and specificity values were measured. RESULTS: There was a negative correlation between mean ADC values and plexus pampiniformis vein diameter (r = -0.467, P < 0.001) and a positive correlation between mean ADC values and sperm count (r = 0.838, P < 0.001) as well as sperm morphology (r = 0.548, P < 0.05). Sensitivity values of 94.3% and 86.6% and specificity values of 87.5% and 43.8% were determined for the best cut-off ADC values in diagnosing the sperm count and morphology, respectively (area under the curve, 0.961 and 0.781). CONCLUSIONS: Decreased testicular ADC values in patients with varicocele are significantly correlated with semen parameters. This method may be used to determine the degree of testicular parenchymal destruction. In addition, testicular ADC cut-off values might be useful in dyspermia patients for the management of patients with varicocele.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Análisis de Semen/estadística & datos numéricos , Testículo/diagnóstico por imagen , Varicocele/diagnóstico por imagen , Adulto , Humanos , Masculino , Proyectos Piloto , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA