Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Mol Biosci ; 10: 1160851, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37577751

RESUMEN

Background: Tissue fibrosis is a major healthcare burden that affects various organs in the body for which no effective treatments exist. An underlying, emerging theme across organs and tissue types at early stages of fibrosis is the activation of pericytes and/or fibroblasts in the perivascular space. In hepatic tissue, it is well known that liver sinusoidal endothelial cells (EC) help maintain the quiescence of stellate cells, but whether this phenomenon holds true for other endothelial and perivascular cell types is not well studied. Methods: The goal of this work was to develop an organ-on-chip microvascular model to study the effect of EC co-culture on the activation of perivascular cells perturbed by the pro-fibrotic factor TGFß1. A high-throughput microfluidic platform, PREDICT96, that was capable of imparting physiologically relevant fluid shear stress on the cultured endothelium was utilized. Results: We first studied the activation response of several perivascular cell types and selected a cell source, human dermal fibroblasts, that exhibited medium-level activation in response to TGFß1. We also demonstrated that the PREDICT96 high flow pump triggered changes in select shear-responsive factors in human EC. We then found that the activation response of fibroblasts was significantly blunted in co-culture with EC compared to fibroblast mono-cultures. Subsequent studies with conditioned media demonstrated that EC-secreted factors play at least a partial role in suppressing the activation response. A Luminex panel and single cell RNA-sequencing study provided additional insight into potential EC-derived factors that could influence fibroblast activation. Conclusion: Overall, our findings showed that EC can reduce myofibroblast activation of perivascular cells in response to TGFß1. Further exploration of EC-derived factors as potential therapeutic targets in fibrosis is warranted.

2.
Lab Chip ; 21(23): 4637-4651, 2021 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-34730597

RESUMEN

Microfluidic lab-on-a-chip devices are changing the way that in vitro diagnostics and drug development are conducted, based on the increased precision, miniaturization and efficiency of these systems relative to prior methods. However, the full potential of microfluidics as a platform for therapeutic medical devices such as extracorporeal organ support has not been realized, in part due to limitations in the ability to scale current designs and fabrication techniques toward clinically relevant rates of blood flow. Here we report on a method for designing and fabricating microfluidic devices supporting blood flow rates per layer greater than 10 mL min-1 for respiratory support applications, leveraging advances in precision machining to generate fully three-dimensional physiologically-based branching microchannel networks. The ability of precision machining to create molds with rounded features and smoothly varying channel widths and depths distinguishes the geometry of the microchannel networks described here from all previous reports of microfluidic respiratory assist devices, regarding the ability to mimic vascular blood flow patterns. These devices have been assembled and tested in the laboratory using whole bovine or porcine blood, and in a porcine model to demonstrate efficient gas transfer, blood flow and pressure stability over periods of several hours. This new approach to fabricating and scaling microfluidic devices has the potential to address wide applications in critical care for end-stage organ failure and acute illnesses stemming from respiratory viral infections, traumatic injuries and sepsis.


Asunto(s)
Dispositivos Laboratorio en un Chip , Microfluídica , Animales , Bovinos , Diseño de Equipo , Porcinos
3.
Artif Organs ; 45(8): E247-E264, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33561881

RESUMEN

Advances in microfluidics technologies have spurred the development of a new generation of microfluidic respiratory assist devices, constructed using microfabrication techniques capable of producing microchannel dimensions similar to those found in human capillaries and gas transfer films in the same thickness range as the alveolar membrane. These devices have been tested in laboratory settings and in some cases in extracorporeal animal experiments, yet none have been advanced to human clinical studies. A major challenge in the development of microfluidic oxygenators is the difficulty in scaling the technology toward high blood flows necessary to support adult humans; such scaling efforts are often limited by the complexity of the fabrication process and the manner in which blood is distributed in a three-dimensional network of microchannels. Conceptually, a central advantage of microfluidic oxygenators over existing hollow-fiber membrane-based configurations is the potential for shallower channels and thinner gas transfer membranes, features that reduce oxygen diffusion distances, to result in a higher gas transfer efficiency defined as the ratio of the volume of oxygen transferred to the blood per unit time to the active surface area of the gas transfer membrane. If this ratio is not significantly higher than values reported for hollow fiber membrane oxygenators (HFMO), then the expected advantage of the microfluidic approach would not be realized in practice, potentially due to challenges encountered in blood distribution strategies when scaling microfluidic designs to higher flow rates. Here, we report on scaling of a microfluidic oxygenator design from 4 to 92 mL/min blood flow, within an order of magnitude of the flow rate required for neonatal applications. This scaled device is shown to have a gas transfer efficiency higher than any other reported system in the literature, including other microfluidic prototypes and commercial HFMO cartridges. While the high oxygen transfer efficiency is a promising advance toward clinical scaling of a microfluidic architecture, it is accompanied by an excessive blood pressure drop in the circuit, arising from a combination of shallow gas transfer channels and equally shallow distribution manifolds. Therefore, next-generation microfluidic oxygenators will require novel design and fabrication strategies to minimize pressure drops while maintaining very high oxygen transfer efficiencies.


Asunto(s)
Cuidados Críticos , Microfluídica/instrumentación , Oxigenadores de Membrana , Diseño de Equipo , Humanos
4.
Sci Rep ; 10(1): 18045, 2020 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-33093518

RESUMEN

Implementation of gene editing technologies such as CRISPR/Cas9 in the manufacture of novel cell-based therapeutics has the potential to enable highly-targeted, stable, and persistent genome modifications without the use of viral vectors. Electroporation has emerged as a preferred method for delivering gene-editing machinery to target cells, but a major challenge remaining is that most commercial electroporation machines are built for research and process development rather than for large-scale, automated cellular therapy manufacturing. Here we present a microfluidic continuous-flow electrotransfection device designed for precise, consistent, and high-throughput genetic modification of target cells in cellular therapy manufacturing applications. We optimized our device for delivery of mRNA into primary human T cells and demonstrated up to 95% transfection efficiency with minimum impact on cell viability and expansion potential. We additionally demonstrated processing of samples comprising up to 500 million T cells at a rate of 20 million cells/min. We anticipate that our device will help to streamline the production of autologous therapies requiring on the order of 10[Formula: see text]-10[Formula: see text] cells, and that it is well-suited to scale for production of trillions of cells to support emerging allogeneic therapies.


Asunto(s)
Sistemas CRISPR-Cas , Tratamiento Basado en Trasplante de Células y Tejidos/métodos , Electroporación/métodos , Edición Génica/métodos , Técnicas de Transferencia de Gen , Microfluídica/métodos , ARN Mensajero/genética , Linfocitos T , Transfección/métodos , Células Cultivadas , Humanos
5.
Lab Chip ; 20(19): 3653, 2020 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-32756648

RESUMEN

Correction for 'A high-throughput microfluidic microphysiological system (PREDICT-96) to recapitulate hepatocyte function in dynamic, re-circulating flow conditions' by Kelly Tan et al., Lab Chip, 2019, 19, 1556-1566, DOI: .

6.
Biomicrofluidics ; 10(5): 054116, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27795748

RESUMEN

In pre-clinical safety studies, drug-induced vascular injury (DIVI) is defined as an adverse response to a drug characterized by degenerative and hyperplastic changes of endothelial cells and vascular smooth muscle cells. Inflammation may also be seen, along with extravasation of red blood cells into the smooth muscle layer (i.e., hemorrhage). Drugs that cause DIVI are often discontinued from development after considerable cost has occurred. An in vitro vascular model has been developed using endothelial and smooth muscle cells in co-culture across a porous membrane mimicking the internal elastic lamina. Arterial flow rates of perfusion media within the endothelial chamber of the model induce physiologic endothelial cell alignment. Pilot testing with a drug known to cause DIVI induced extravasation of red blood cells into the smooth muscle layer in all devices with no extravasation seen in control devices. This engineered vascular model offers the potential to evaluate candidate drugs for DIVI early in the discovery process. The physiologic flow within the co-culture model also makes it candidate for a wide variety of vascular biology investigations.

7.
Lab Chip ; 16(5): 829-46, 2016 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-26778829

RESUMEN

The anatomical and pharmacological inaccessibility of the inner ear is a major challenge in drug-based treatment of auditory disorders. This also makes pharmacokinetic characterization of new drugs with systemic delivery challenging, because efficacy is coupled with how efficiently a drug can reach its target. Direct delivery of drugs to cochlear fluids bypasses pharmacokinetic barriers and helps to minimize systemic toxicity, but anatomical barriers make administration of multiple doses difficult without an automated delivery system. Such a system may be required for hair-cell regeneration treatments, which will likely require timed delivery of several drugs. To address these challenges, we have developed a micropump for controlled, automated inner-ear drug delivery with the ultimate goal of producing a long-term implantable/wearable delivery system. The current pump is designed to be used with a head mount for guinea pigs in preclinical drug characterization experiments. In this system, we have addressed several microfluidic challenges, including maintaining controlled delivery at safe, low flow rates and delivering drug without increasing the volume of fluid in the cochlea. By integrating a drug reservoir and all fluidic components into the microfluidic structure of the pump, we have made the drug delivery system robust compared to previous systems that utilized separate, tubing-connected components. In this study, we characterized the pump's unique infuse-withdraw and on-demand dosing capabilities on the bench and in guinea pig animal models. For the animal experiments, we used DNQX, a glutamate receptor antagonist, as a physiological indicator of drug delivery. DNQX suppresses compound action potentials (CAPs), so we were able to infer the distribution and spreading of the DNQX over time by measuring the changes in CAPs in response to stimuli at several characteristic frequencies.


Asunto(s)
Cóclea , Sistemas de Liberación de Medicamentos , Bombas de Infusión , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas , Animales , Sistemas de Liberación de Medicamentos/instrumentación , Sistemas de Liberación de Medicamentos/métodos , Cobayas , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos
8.
Biomed Microdevices ; 17(2): 37, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25686902

RESUMEN

One of the major challenges in treatment of auditory disorders is that many therapeutic compounds are toxic when delivered systemically. Local intracochlear delivery methods are becoming critical in emerging treatments and in drug discovery. Direct infusion via cochleostomy, in particular, is attractive from a pharmacokinetics standpoint, as there is potential for the kinetics of delivery to be well-controlled. Direct infusion is compatible with a large number of drug types, including large, complex molecules such as proteins and unstable molecules such as siRNA. In addition, hair-cell regeneration therapy will likely require long-term delivery of a timed series of agents. This presents unknown risks associated with increasing the volume of fluid within the cochlea and mechanical damage caused during delivery. There are three key requirements for an intracochlear drug delivery system: (1) a high degree of miniaturization (2) a method for pumping precise and small volumes of fluid into the cochlea in a highly controlled manner, and (3) a method for removing excess fluid from the limited cochlear fluid space. To that end, our group is developing a head-mounted microfluidics-based system for long-term intracochlear drug delivery. We utilize guinea pig animal models for development and demonstration of the device. Central to the system is an infuse-withdraw micropump component that, unlike previous micropump-based systems, has fully integrated drug and fluid storage compartments. Here we characterize the infuse-withdraw capabilities of our micropump, and show experimental results that demonstrate direct drug infusion via cochleostomy in animal models. We utilized DNQX, a glutamate receptor antagonist that suppresses CAPs, as a test drug. We monitored the frequency-dependent changes in auditory nerve CAPs during drug infusion, and observed CAP suppression consistent with the expected drug transport path based on the geometry and tonotopic organization of the cochlea.


Asunto(s)
Cóclea , Sistemas de Liberación de Medicamentos/instrumentación , Bombas de Infusión , Microfluídica/instrumentación , Animales , Cóclea/efectos de los fármacos , Vías de Administración de Medicamentos , Sistemas de Liberación de Medicamentos/métodos , Diseño de Equipo , Cobayas , Masculino , Microtecnología , Miniaturización , Quinoxalinas/administración & dosificación
9.
Lab Chip ; 14(4): 710-21, 2014 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-24302432

RESUMEN

Reciprocating microfluidic drug delivery, as compared to steady or pulsed infusion, has unique features which may be advantageous in many therapeutic applications. We have previously described a device, designed for wearable use in small animal models, that periodically infuses and then withdraws a sub-microliter volume of drug solution to and from the endogenous fluid of the inner ear. This delivery approach results in zero net volume of liquid transfer while enabling mass transport of compounds to the cochlea by means of diffusion and mixing. We report here on an advanced wearable delivery system aimed at further miniaturization and complex dosing protocols. Enhancements to the system include the incorporation of a planar micropump to generate reciprocating flow and a novel drug reservoir that maintains zero net volume delivery and permits programmable modulation of the drug concentration in the infused bolus. The reciprocating pump is fabricated from laminated polymer films and employs a miniature electromagnetic actuator to meet the size and weight requirements of a head-mounted in vivo guinea pig testing system. The reservoir comprises a long microchannel in series with a micropump, connected in parallel with the reciprocating flow network. We characterized in vitro the response and repeatability of the planar pump and compared the results with a lumped element simulation. We also characterized the performance of the reservoir, including repeatability of dosing and range of dose modulation. Acute in vivo experiments were performed in which the reciprocating pump was used to deliver a test compound to the cochlea of anesthetized guinea pigs to evaluate short-term safety and efficacy of the system. These advances are key steps toward realization of an implantable device for long-term therapeutic applications in humans.


Asunto(s)
Cóclea , Sistemas de Liberación de Medicamentos/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Animales , Colorantes/administración & dosificación , Electricidad , Cobayas , Modelos Teóricos
10.
Biomaterials ; 34(38): 10007-15, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24079890

RESUMEN

A biodegradable microvessel scaffold comprised of distinct parenchymal and vascular compartments separated by a permeable membrane interface was conceptualized, fabricated, cellularized, and implanted. The device was designed with perfusable microfluidic channels on the order of 100 µm to mimic small blood vessels, and high interfacial area to an adjacent parenchymal space to enable transport between the compartments. Poly(glycerol sebacate) (PGS) elastomer was used to construct the microvessel framework, and various assembly methods were evaluated to ensure robust mechanical integrity. In vitro studies demonstrated the differentiation of human skeletal muscle cells cultured in the parenchymal space, a 90% reduction in muscle cell viability due to trans-membrane transport of a myotoxic drug from the perfusate, and microvessel seeding with human endothelial cells. In vivo studies of scaffolds implanted subcutaneously and intraperitoneally, without or with exogenous cells, into nude rats demonstrated biodegradation of the membrane interface and host blood cell infiltration of the microvessels. This modular, implantable scaffold could serve as a basis for building tissue constructs of increasing scale and clinical relevance.


Asunto(s)
Decanoatos/química , Glicerol/análogos & derivados , Polímeros/química , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Animales , Supervivencia Celular/fisiología , Células Cultivadas , Glicerol/química , Humanos , Microscopía Electrónica de Rastreo , Músculo Esquelético/citología , Ratas
11.
Adv Healthc Mater ; 1(2): 164-7, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22708076

RESUMEN

A device containing a 3D microchannel network (fabricated using sacrificial melt-spun microfibers) sandwiched between lithographically patterned microfluidic channels offers improved delivery of soluble compounds to a large volume compared to a simple stack of two microfluidic channel layers. With this improved delivery ability comes an increased fluidic resistance due to the tortuous network of small-diameter channels.


Asunto(s)
Dimetilpolisiloxanos/química , Técnicas Analíticas Microfluídicas/instrumentación , Impresión Molecular/instrumentación , Fotograbar/métodos , Diseño de Equipo , Análisis de Falla de Equipo
12.
Lab Chip ; 12(9): 1686-95, 2012 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-22418858

RESUMEN

Microfluidic fabrication technologies are emerging as viable platforms for extracorporeal lung assist devices and oxygenators for cardiac surgical support and critical care medicine, based in part on their ability to more closely mimic the architecture of the human vasculature than existing technologies. In comparison with current hollow fiber oxygenator technologies, microfluidic systems have more physiologically-representative blood flow paths, smaller cross section blood conduits and thinner gas transfer membranes. These features can enable smaller device sizes and a reduced blood volume in the oxygenator, enhanced gas transfer efficiencies, and may also reduce the tendency for clotting in the system. Several critical issues need to be addressed in order to advance this technology from its current state and implement it in an organ-scale device for clinical use. Here we report on the design, fabrication and characterization of multilayer microfluidic oxygenators, investigating scaling effects associated with fluid mechanical resistance, oxygen transfer efficiencies, and other parameters in multilayer devices. Important parameters such as the fluidic resistance of interconnects are shown to become more predominant as devices are scaled towards many layers, while other effects such as membrane distensibility become less significant. The present study also probes the relationship between blood channel depth and membrane thickness on oxygen transfer, as well as the rate of oxygen transfer on the number of layers in the device. These results contribute to our understanding of the complexity involved in designing three-dimensional microfluidic oxygenators for clinical applications.


Asunto(s)
Oxigenación por Membrana Extracorpórea/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Modelos Teóricos , Diseño de Equipo , Humanos , Oxígeno/sangre , Intercambio Gaseoso Pulmonar/fisiología
13.
Dig Dis Sci ; 57(5): 1152-62, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22359192

RESUMEN

BACKGROUND: Hepatic stellate cells (HSC) play a major role in the progression of liver fibrosis. AIM: The aim of our study was to investigate whether rat HSC cultured on a nanofiber membrane (NM) retain their quiescent phenotype during both short- and long-term culture and whether activated HSC revert to a quiescent form when re-cultured on NM. METHODS: Rat HSC cultured for 1 day on plastic plates (PP) were used as quiescent HSC, while cells cultured for 1 week on PP were considered to be activated HSC. Quiescent or activated HSC were subsequently plated on PP or NM and cultured for an additional 4 days at which time their gene expression, stress fiber development, and growth factor production were determined. For long-term culture, HSC were grown on NM for 20 days and the cells then replated on PP and cultured for another 10 days. RESULTS: Expression of marker genes for HSC activation, stress fiber development, and growth factor production were significantly lower in both quiescent and activated HSC cultured on NM than in those cultured on PP. After long-term culture on NM, activation marker gene expression and stress fiber development were still significantly lower in HSC than in PP, and HSC still retained the ability to activate when replated onto PP. CONCLUSIONS: HSC cultured on NM retained quiescent characteristics after both short- and long-term culture while activated HSC reverted toward a quiescent state when cultured on NM. Cultures of HSC grown on NM are a useful in vitro model to investigate the mechanisms of activation and deactivation.


Asunto(s)
Células Estrelladas Hepáticas/citología , Nanofibras , Plásticos , Cultivo Primario de Células/instrumentación , Animales , Factores Biológicos/biosíntesis , Factores Biológicos/genética , Adhesión Celular , Movimiento Celular , Endotelina-1/genética , Perfilación de la Expresión Génica , Células Estrelladas Hepáticas/metabolismo , Cirrosis Hepática/metabolismo , Cirrosis Hepática/patología , Masculino , Cultivo Primario de Células/métodos , Ratas , Ratas Wistar , Fibras de Estrés/genética , Factores de Tiempo , Factor de Crecimiento Transformador beta2/genética
14.
J Control Release ; 152(2): 270-7, 2011 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-21385596

RESUMEN

Reciprocating drug delivery is a means of delivering soluble drugs directly to closed fluid spaces in the body via a single cannula without an accompanying fluid volume change. It is ideally suited for drug delivery into small, sensitive and unique fluid spaces such as the cochlea. We characterized the pharmacokinetics of reciprocating drug delivery to the scala tympani within the cochlea by measuring the effects of changes in flow parameters on the distribution of drug throughout the length of the cochlea. Distribution was assessed by monitoring the effects of DNQX, a reversible glutamate receptor blocker, delivered directly to the inner ear of guinea pigs using reciprocating flow profiles. We then modeled the effects of those parameters on distribution using both an iterative curve-fitting approach and a computational fluid dynamic model. Our findings are consistent with the hypothesis that reciprocating delivery distributes the drug into a volume in the base of the cochlea, and suggest that the primary determinant of distribution throughout more distal regions of the cochlea is diffusion. Increases in flow rate distributed the drug into a larger volume that extended more apically. Over short time courses (less than 2h), the apical extension, though small, significantly enhanced apically directed delivery of drug. Over longer time courses (>5h) or greater distances (>3mm), maintenance of drug concentration in the basal scala tympani may prove more advantageous for extending apical delivery than increases in flow rate. These observations demonstrate that this reciprocating technology is capable of providing controlled delivery kinetics to the closed fluid space in the cochlea, and may be suitable for other applications such as localized brain and retinal delivery.


Asunto(s)
Sistemas de Liberación de Medicamentos/instrumentación , Antagonistas de Aminoácidos Excitadores/administración & dosificación , Antagonistas de Aminoácidos Excitadores/farmacocinética , Quinoxalinas/administración & dosificación , Quinoxalinas/farmacocinética , Rampa Timpánica/metabolismo , Animales , Simulación por Computador , Difusión , Diseño de Equipo , Cobayas , Hidrodinámica , Cinética , Modelos Biológicos
15.
Audiol Neurootol ; 14(6): 411-22, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19923811

RESUMEN

BACKGROUND: Direct delivery of drugs and other agents into the inner ear will be important for many emerging therapies, including the treatment of degenerative disorders and guiding regeneration. METHODS: We have taken a microfluidics/MEMS (MicroElectroMechanical Systems) technology approach to develop a fully implantable reciprocating inner-ear drug-delivery system capable of timed and sequenced delivery of agents directly into perilymph of the cochlea. Iterations of the device were tested in guinea pigs to determine the flow characteristics required for safe and effective delivery. For these tests, we used the glutamate receptor blocker DNQX, which alters auditory nerve responses but not cochlear distortion product otoacoustic emissions. RESULTS: We have demonstrated safe and effective delivery of agents into the scala tympani. Equilibration of the drug in the basal turn occurs rapidly (within tens of minutes) and is dependent on reciprocating flow parameters. CONCLUSION: We have described a prototype system for the direct delivery of drugs to the inner ear that has the potential to be a fully implantable means for safe and effective treatment of hearing loss and other diseases.


Asunto(s)
Cóclea/efectos de los fármacos , Sistemas de Liberación de Medicamentos/instrumentación , Microfluídica/instrumentación , Perilinfa/efectos de los fármacos , Estimulación Acústica , Animales , Cóclea/fisiología , Sistemas de Liberación de Medicamentos/métodos , Cobayas , Microfluídica/métodos , Emisiones Otoacústicas Espontáneas/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...