Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Acoust Soc Am ; 156(2): 1319-1323, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39177363

RESUMEN

Previous research demonstrated the potential of using speakers as sensors to detect ear canal conditions. This study continues that effort by using a single speaker to measure electrical impedance across various acoustic loads. Electrical impedance data were collected and preprocessed for machine learning model training. Different image forms were tested, including magnitude only and combined magnitude phase. Using 2100 data samples with convolutional neural network-based models (AlexNet, ResNet, and DenseNet), binary and multiclass classifications achieved average accuracies of 0.9716 and 0.907, respectively. This innovative approach is set to revolutionize acoustic sensing through artificial intelligence.


Asunto(s)
Acústica , Inteligencia Artificial , Humanos , Impedancia Eléctrica , Redes Neurales de la Computación , Conducto Auditivo Externo/fisiología , Aprendizaje Automático
2.
Medicina (Kaunas) ; 60(5)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38792927

RESUMEN

Background and Objective: The aim of this study was to analyze trends in surgical and non-surgical service utilization for common shoulder disorders in Korea from 2010 to 2019. Methods and Materials: This retrospective, cross-sectional, descriptive study utilized National Patient Sample data from the Health Insurance and Review Assessment Service (HIRA) of Korea. These data constitute a 2% sample out of the entire Korean population and include data for a variety of parameters instrumental for health care research. Patients with at least one medical service use for rotator cuff syndrome or tear, impingement syndrome, or adhesive capsulitis between January 2010 and December 2019 were included. Trends in healthcare utilization by disorder type, patient demographics, seasonal service use, and treatment details were examined. Results: There was an upward trend in the total number of patients and costs for shoulder disorders, from 35,798 patients and USD 5,485,196 in 2010 to 42,558 and USD 11,522,543 in 2019, respectively. The number of patients aged ≥60 and hospital visits increased. March had the highest number of claims. Physical therapy was the most common non-surgical procedure, while nerve block claims more than doubled. Opioid prescription rates also tripled. Surgical treatments were dominated by shoulder rotator cuff repair and acromioplasty. Conclusions: There was a significant increase in healthcare utilization for shoulder disorders, marked by rising costs and patient numbers. The use of nerve blocks and opioids notably increased. These data are valuable for clinicians, researchers, and policymakers.


Asunto(s)
Aceptación de la Atención de Salud , Humanos , República de Corea/epidemiología , Estudios Transversales , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Anciano , Aceptación de la Atención de Salud/estadística & datos numéricos , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/terapia , Adolescente , Síndrome de Abducción Dolorosa del Hombro/cirugía , Síndrome de Abducción Dolorosa del Hombro/terapia , Seguro de Salud/estadística & datos numéricos
3.
Imaging Sci Dent ; 42(4): 201-5, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23301204

RESUMEN

PURPOSE: This study was performed to assess the compatibility of cone beam computed tomography (CBCT) synthesized cephalograms with conventional cephalograms, and to find a method for obtaining normative values for three-dimensional (3D) assessments. MATERIALS AND METHODS: The sample group consisted of 10 adults with normal occlusion and well-balanced faces. They were imaged using conventional and CBCT cephalograms. The CBCT cephalograms were synthesized from the CBCT data using OnDemand 3D software. Twenty-one angular and 12 linear measurements from each imaging modality were compared and analyzed using paired-t test. RESULTS: The linear measurements between the two imaging modalities were not statistically different (p>0.05) except for the U1 to facial plane distance. The angular measurements between the two imaging modalities were not statistically different (p>0.05) with the exception of the gonial angle, ANB difference, and facial convexity. CONCLUSION: Two-dimensional cephalometric norms could be readily used for 3D quantitative assessment, if corrected for lateral cephalogram distortion.

SELECCIÓN DE REFERENCIAS