1.
PLoS One ; 18(10): e0293191, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37871021

RESUMEN

In this study, some confusing points about electron film dosimetry using white polystyrene suggested by international protocols were verified using a clinical linear accelerator (LINAC). According to international protocol recommendations, ionometric measurements and film dosimetry were performed on an SP34 slab phantom at various electron energies. Scaling factor analysis using ionometric measurements yielded a depth scaling factor of 0.923 and a fluence scaling factor of 1.019 at an electron beam energy of <10 MeV (i.e., R50 < 4.0 g/cm2). It was confirmed that the water-equivalent characteristics were similar because they have values similar to white polystyrene (i.e., depth scaling factor of 0.922 and fluence scaling factor of 1.019) presented in international protocols. Furthermore, percentage depth dose (PDD) curve analysis using film dosimetry showed that when the density thickness of the SP34 slab phantom was assumed to be water-equivalent, it was found to be most similar to the PDD curve measured using an ionization chamber in water as a reference medium. Therefore, we proved that the international protocol recommendation that no correction for measured depth dose is required means that no scaling factor correction for the plastic phantom is necessary. This study confirmed two confusing points that could occur while determining beam characteristics using electron film dosimetry, and it is expected to be used as basic data for future research on clinical LINACs.


Asunto(s)
Dosimetría por Película , Poliestirenos , Dosimetría por Película/métodos , Aceleradores de Partículas , Radioterapia de Alta Energía/métodos , Fantasmas de Imagen , Agua , Radiometría/métodos
2.
J Nanosci Nanotechnol ; 20(11): 6985-6991, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-32604546

RESUMEN

Phosphor screens have attracted increasing global interest because they can aid the acquisition of high-quality images while simultaneously reducing exposure. However, although increasing the thickness of the phosphor screen increases exposure efficiency due to scattered light, it also leads to a broader light spread, which results in poorer resolution. Hence, in this study, we implemented a reflector using a mirror-coating technique on the surface of a phosphor screen and analyzed its characteristics in terms of luminescence intensity and resolution. We present the fabrication and measurement of the phosphor screen based on a reflector containing Gd2O2S:Tb. The phosphor screen containing the reflector can be fabricated via the screen-printing method and roll-to-roll sputtering method. In particular, when compared to the condition without a reflector, Al and Cu reflectors showed improvements in luminescence intensity of 15.7% and 12.2%, respectively, as well as lower full widths at half maximum of 11.45 and 9.08, respectively. This quantitatively demonstrates that Cu and Al are suitable reflector materials to improve exposure efficiency while maintaining resolution in radiography systems. Moreover, because we did not utilize an optical assembly, which improves the transmission efficiency by matching the different refractive indices of the phosphor screen and photo-detector, we believe that the quantity of photons could be further improved if the reflectors were applied to a commercial product. Thus, future studies using single-layer anti-reflector coating techniques with optical assemblies are warranted.

3.
J Nanosci Nanotechnol ; 18(9): 5976-5981, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29677727

RESUMEN

With increasingly strict regulations regarding patient exposure, research on digital radiography technology has recently focused on indirect methods that can produce high-quality images for a low radiation dose. In particular, medical imaging systems based on indirect methods universally use rare-earth metal phosphors, because of their high atomic number and excellent luminescence efficiency. Thus, various studies aiming to improve the luminescence efficiency of phosphors have been conducted. Despite this research, however, the current luminescence efficiencies are insufficient. Here, we report a basic study aiming to develop a phosphor screen containing a three-quarter-wave optical-thickness layer to improve the light transmission efficiency. Specifically, the fabrication and measurement of a Gd2O2S:Tb phosphor screen containing a single three-quarter-wave optical-thickness layer is presented. The screen is fabricated via a screen-printing and spin-coating method. Based on histograms of the degree of luminescence and the pixel values, we demonstrate that the light transmission efficiency is improved by the three-quarter-wave optical-thickness layer. Note that analysis of the full width at half maximum of the pixel value distribution reveals the possibility of resolution loss when obtaining medical images. Overall, the results of this study confirm that the light transmission efficiency can be improved through use of a single-layer anti-reflection coating. However, because the emission spectrum of the Gd2O2S:Tb screen is in the 480-600-nm band, it is necessary to expand the areas exhibiting the lowest reflectance to the wavelengths at the edge of this band. Thus, further study should be conducted to optimize the optical thickness.