Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
World J Urol ; 42(1): 228, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38598022

RESUMEN

PURPOSE: Commercial double J stents (DJS) have a uniform shape regardless of the specific nature of various ureteral diseases. We tested renovated DJS and compared them with conventional DJS using ureter models. METHODS: One straight ureter model included stenosis at the distal ureter near the ureterovesical junction and the other did not. We used conventional DJS and renovated 5- and 6-Fr soft DJS for ureter stones and 6-, 7-, and 8.5-Fr hard DJS for tumors. The DJS comprised holes in the upper, middle, or lower one-third of the shaft (length, 24 cm; 2-cm-diameter coils at both ends). More holes were created along the shaft based on the ureteral disease location. Conventional DJS had holes spaced 1 cm apart along the shaft. Renovated DJS had holes spaced 1 cm apart along the shaft with 0.5-cm intervals on the upper, middle, or lower one-third of the shaft. Urine flow was evaluated. RESULTS: As the DJS diameter increased, the flow rate decreased. The flow rates of DJS with holes in the lower shaft were relatively lower than those of conventional DJS and DJS with holes in the upper and middle shafts. In the ureter model without stenosis, 6-, 7-, and 8.5-Fr renovated stents exhibited significantly higher flow rates than conventional stents. In the ureter model with stenosis, 5-, 6-, 7-, and 8.5-Fr renovated stents did not exhibit significantly higher flow rates than conventional stents. CONCLUSION: Renovated stents and conventional stents did not exhibit significant differences in urine flow with stenosis.


Asunto(s)
Uréter , Ureterolitiasis , Humanos , Uréter/cirugía , Constricción Patológica , Stents
2.
J Thromb Haemost ; 22(5): 1389-1398, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38278416

RESUMEN

BACKGROUND: Iatrogenic femoral artery pseudoaneurysm (IFP) incidence is increasing with increase in diagnostic and therapeutic angiography, and so, the less invasive percutaneous thrombin injection (PTI) is the most widely used treatment. Moreover, studies that minimize PTI complications and highlight therapeutic effects are lacking. OBJECTIVES: This study performed in vitro thrombosis modeling of pseudoaneurysms and analyzed thrombosis within and thromboembolism outside the sac during thrombin injection. METHODS: We evaluated PTI in terms of thrombin injection location (at the junction of the IFP sac and neck, the center, and the dome, located farthest from the neck of the sac), thrombin injection time (5 and 8 seconds), and blood flow rate (ranging from 210 mL/min to 300 mL/min). Porcine blood was used as the working fluid in this study. RESULTS: Thrombin injection at the junction of the IFP sac and the pseudoaneurysm neck led to less thrombosis within the sac but substantial thrombi consistently outside the sac, whereas thrombin injected at the sac center mostly led to complete thrombosis within the sac, preventing further blood flow into the sac and reducing likelihood of thrombi outside the sac. A longer thrombin injection time enhanced the therapeutic effect and decreased the possibility of thromboembolism. Thromboembolism occurred more frequently at flow rates of >240 mL/min. CONCLUSION: The thrombin injection site in a pseudoaneurysm significantly influences thrombogenesis within and thromboembolism outside the sac. Thus, slow and deliberate injection of thrombin into the center of the sac could potentially reduce complications and enhance treatment efficacy.


Asunto(s)
Aneurisma Falso , Arteria Femoral , Trombina , Trombosis , Trombina/administración & dosificación , Aneurisma Falso/tratamiento farmacológico , Animales , Trombosis/tratamiento farmacológico , Trombosis/etiología , Porcinos , Inyecciones Intraarteriales , Factores de Tiempo , Humanos , Tromboembolia/tratamiento farmacológico , Tromboembolia/prevención & control , Tromboembolia/etiología , Enfermedad Iatrogénica
3.
Artículo en Inglés | MEDLINE | ID: mdl-37647248

RESUMEN

The effect of side holes morphology changes in double J stent (DJS) on encrustation was analyzed using computational fluid dynamics (CFD). We analyzed DJS side holes with inner diameter of 1 mm and outer diameters of 1 (type A), 1.2 (type B) and 1.4 (type C) mm, respectively. Concentric stenosis with three intraureteral degree (0%, 12%, and 88%) was analyzed. The flow rate, shear stress and wall shear stress (WSS) distribution were investigated. Urine flow through SH1 before the ureteropelvic junction (UPJ) differed based on the ureteral stenosis degree. The sum of flow rates through the SHs increased with diameter. In the stented ureter with 12% stenosis, the flow rate through SH1 approximately doubled than that without ureteral stenosis, and the flow rate through SH1 was maximal for the type 'C' stent in both 12% and 88% ureteral stenosis. The mean shear stress in the SHs increased with the degree of stenosis. The WSS around the SHs was higher for type 'C' than types A and B. From the flow rates and shear stresses in and around the SHs, the larger SH diameter of the DJS from the UPJ to mid-ureter is expected to induce encrustation reduction, especially in patients with urinary lithiasis.

4.
Clin Nephrol ; 99(6): 290-298, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36999524

RESUMEN

PURPOSE: To evaluate the formation of encrustation on double J stents (DJSs) using artificial urine. MATERIALS AND METHODS: In this study, a static urinary system containing artificial urine was created, and a total of 45 DJSs were used to evaluate the formation of encrustation. Three groups of 15 DJSs were tested for 4, 8, or 14 weeks. The formation of encrustation on the DJSs over the weeks was analyzed using methods including X-ray powder diffraction (XRD), inductively coupled plasma spectrophotometer (ICP), and scanning electron microscope (SEM). Statistical analysis and the uncertainty test were used for data analysis using R language. RESULTS: The ICP analyzed the weight of the calcium and magnesium, which are the major components of urinary stones and encrustation, and showed that it was the heaviest at 14 weeks. Measurement of the area of encrustation on the outer surface of the DJSs revealed that the encrustation area at the bottom of the stent was greater than that at the top of the stent, regardless of the experimental period (proximal part: ≤ 41,099 µm2, distal part: ≤ 183,259 µm2). Encrustation occurred around the side holes of DJSs and became bigger over time to fill up the side holes. CONCLUSION: Encrustation spots included the bottom zone of the DJS and around the side holes. These results indicate that the performance of DJSs would be improved by modifying the shape of DJSs located near the bladder and side holes.


Asunto(s)
Uréter , Urolitiasis , Humanos , Stents , Calcio , Magnesio , Orina
5.
Comput Biol Med ; 145: 105456, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35390747

RESUMEN

OBJECTIVE: This study investigates the effects of vesicoureteral reflux (VUR) in the upper and lower urinary tracts with and without ureteral stenosis and with a double J stent (DJS). METHODS: The entire length of the urinary tract with an implanted DJS was modeled. To assess the possibility of VUR, the measured values were used as boundary conditions for the baseline, the maximum cystometric bladder capacity (MCBC) during the filling phase, and maximum vesical pressure during the voiding phase were computed. The flow rates, flow patterns, wall shear stress (WSS) distribution, impact force induced by reflux urination, and helicity of the bladder were investigated for the urinary system. RESULTS: The flow from the bladder to the renal pelvis was detected at maximum vesical pressure (75 cmH2O) during the voiding phase, and a small amount (1.09 mL/s) of VUR was noted at the MCBC during the filling phase. The WSS increased when the reflux was large. Helicity within the bladder varied with the stenosis as well as opening and closing of the urethra. The reflux within the stent was reduced by 40% by inserting a ball into the stent. CONCLUSION: The main VUR factor was the opening and closing of the vesicoureteric junction by the detrusor muscle. The largest urine reflux (11.7 mL/s) to the kidney occurred when the detrusor muscle was relaxed. SIGNIFICANCE: Ureteral stenosis affected the VUR and reduced urine reflux. Ball insertion in the stent reduced urine reflux through the stent lumen.


Asunto(s)
Reflujo Vesicoureteral , Constricción Patológica , Humanos , Stents , Vejiga Urinaria , Micción/fisiología
6.
Korean J Radiol ; 22(11): 1834-1840, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34402241

RESUMEN

OBJECTIVE: To analyze the computational fluid dynamics (CFD) of femoral artery pseudoaneurysm (FAP), identify a suitable location and timing for percutaneous thrombin injection (PTI) based on this analysis, and report our clinical experience with the procedure. MATERIALS AND METHODS: CFD can be used to analyze the hemodynamics of the human body. An analysis using CFD recommended that the suitable location of the needle tip for PTI is at the center of the aneurysm sac and the optimal timing for starting PTI is during the early inflow phase of blood into the sac. Since 2011, seven patients (three male and four female; median age, 60 years [range, 43-75 years]) with FAP were treated with PTI based on the devised suitable location and time. Prior to the procedure, color Doppler ultrasonography was performed to determine the location and timing of the thrombin injection. RESULTS: The technical success rate of the PTI was 100%. The amount of thrombin used for the procedure ranged from 200 IU to 1000 IU (median, 500 IU). None of the patients experienced any symptoms or signs of embolic complications during the procedure. Follow-up CT images did not reveal any embolism in the lower extremities and showed complete thrombosis of the pseudoaneurysm. CONCLUSION: Based on our study of CFD, PTI administered centrally in the FAP during early inflow, as seen on color Doppler, can be an effective technique.


Asunto(s)
Aneurisma Falso , Trombina , Adulto , Anciano , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/tratamiento farmacológico , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Hidrodinámica , Masculino , Persona de Mediana Edad , Trombina/administración & dosificación , Ultrasonografía Intervencional
7.
Int J Numer Method Biomed Eng ; 36(2): e3294, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31981313

RESUMEN

A double J stent (DJS) is used to alleviate the congestion of urine in the upper urinary tract when there is ureteral stenosis, which causes the interruption of normal urine flow and results in renal failure. The purpose of placing DJSs is to ensure sufficient urine flow in the ureter, but the DJS acts as a foreign body in the urinary system and sometimes acts as an obstacle in achieving sufficient urine flow. Here, to evaluate the performance of various sizes of DJSs, 5Fr (1.666 mm) to 8Fr (2.666 mm), in the ureter, silicon ureter models without stenosis, and a circulation setup were constructed. The total flow rates (TFRs) in the stented ureters were evaluated with an in vitro experiment. The TFRs in the 5Fr DJS were larger than those in the other sizes of DJS. As the size of DJS increased, the TFR decreased. Computational fluid dynamics was also applied to validate the experimental results. It was shown that the experimental results agreed well with the numerical results.


Asunto(s)
Hidrodinámica , Stents , Uréter/cirugía , Obstrucción Ureteral/cirugía , Adulto , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis
8.
Technol Health Care ; 25(S1): 63-72, 2017 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-28582893

RESUMEN

Ureteral stenosis presents with a narrowing in the ureter, due to an intrinsic or extrinsic ureteral disease, such as ureter cancer or retroperitoneal fibrosis. The placement of a double J stent in the upper urinary system is one of the most common treatments of ureteral stenosis, along with the insertion of a percutaneous nephrostomy tube into the renal pelvis. The effect that the side holes in a double J stent have on urine flow has been evaluated in a few studies using straight ureter models. In this study, urine flow through a double J stent's side holes was analyzed in curved ureter models, which were based on human anatomy. In ureteral stenosis, especially in severe ureteral stenosis, a stent with side holes had a positive effect on the luminal and total flow rates, compared with the rates for a stent without side holes. The more side holes a stent has, the greater the luminal and total flow rates. However, the angular positions of the side holes did not affect flow rate. In conclusion, the side holes in a double J stent had a positive effect on ureteral stenosis, and the effect became greater as the ureteral stenosis became more severe.


Asunto(s)
Stents , Obstrucción Ureteral/terapia , Constricción Patológica , Humanos , Diseño de Prótesis , Obstrucción Ureteral/fisiopatología , Urodinámica/fisiología
9.
Comput Math Methods Med ; 2017: 5172641, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28659992

RESUMEN

The ureter provides a way for urine to flow from the kidney to the bladder. Peristalsis in the ureter partially forces the urine flow, along with hydrostatic pressure. Ureteral diseases and a double J stent, which is commonly inserted in a ureteral stenosis or occlusion, disturb normal peristalsis. Ineffective or no peristalsis could make the contour of the ureter a tube, a funnel, or a combination of the two. In this study, we investigated urine flow in the abnormal situation. We made three different, curved tubular, funnel-shaped, and undulated ureter models that were based on human anatomy. A numerical analysis of the urine flow rate and pattern in the ureter was performed for a combination of the three different ureters, with and without a ureteral stenosis and with four different types of double J stents. The three ureters showed a difference in urine flow rate and pattern. Luminal flow rate was affected by ureter shape. The side holes of a double J stent played a different role in detour, which depended on ureter geometry.


Asunto(s)
Modelos Biológicos , Uréter/anatomía & histología , Uréter/fisiología , Humanos , Peristaltismo , Stents
10.
J Craniofac Surg ; 26(8): e765-70, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26595001

RESUMEN

OBJECTIVE: The aim of the study was to compare the effect of conventional maxillomandibular advancement (MMA) and modified MMA with anterior segmental setback osteotomy (MMA-ASSO) on the airway changes in patients with obstructive sleep apnea syndrome (OSAS) using three-dimensional computational fluid dynamics (3D-CFD) analysis. METHODS: Two adult male patients with Class I malocclusion, lip protrusion, acute nasolabial angle, and OSAS were treated with conventional MMA (Case 1) and modified MMA-ASSO (Case 2). Individualized 3D airway models were fabricated using computed tomography data obtained 1 month before (T0) and at least 6 months after surgery (T1). A total of 7 cross-sectional areas of the airway were established, starting just above the hard palate (plane 1) with interval of 1 mm caudally. Airflow velocity and negative pressure were investigated using CFD analysis, and polysomnography studies were performed at T0 and T1. RESULTS: There were improvement of apnea-hypoapnea index and the lowest O2 level (T0 versus T1; 43.2 versus 15.2, 79% versus 90% in Case 1; 61.0 versus 6, 89% versus 92% in Case 2). At plane 2 (retropalatal area) in Cases 1 and 2, there were increase in the smallest cross-sectional areas (57.9% versus 28.4%), decrease in the airflow velocity and increase in the negative pressure at the peak of expiration (49.5% versus 31.7%; 88.4% versus 54.3%), end after expiration (53.2% versus 32.2%; 83.2% versus 47.9%), and peak of inspiration (53.1% versus 29.2%; 75.3% versus 48.2%). CONCLUSION: Modified MMA-ASSO method might be an effective treatment option for OSAS patients with improvement of airway problems and esthetic facial profile.


Asunto(s)
Avance Mandibular/métodos , Osteotomía Maxilar/métodos , Faringe/anatomía & histología , Apnea Obstructiva del Sueño/cirugía , Adulto , Anatomía Transversal , Estudios de Seguimiento , Mentoplastia/métodos , Humanos , Hidrodinámica , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Inhalación/fisiología , Masculino , Maloclusión Clase I de Angle/cirugía , Osteotomía Le Fort/métodos , Osteotomía Sagital de Rama Mandibular/métodos , Paladar Duro/anatomía & histología , Modelación Específica para el Paciente , Ápice del Flujo Espiratorio/fisiología , Polisomnografía/métodos , Presión , Ventilación Pulmonar/fisiología , Tomografía Computarizada por Rayos X/métodos
11.
Biomed Mater Eng ; 26 Suppl 1: S215-23, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26405994

RESUMEN

A ureteral stenosis or occlusion causes the disturbance of normal urine flow and results in renal failure. Ureteral stents are used to relieve the stagnation of urine in the upper urinary tract. Peristalsis in the ureter, which occurs to help urine flow, becomes to weaken when a stent is inserted and effective peristalsis disappears as time goes on, and a stented ureter seems to be tubular and curved in the human body. Double J stents, which are manufactured by many medical companies and are used widely these days, have different geometries of side holes in the stent shafts. In total, 12 models-six curved models of a stented ureter according to different numbers and positions of side holes and ureteral and stent stenoses and another six straight models for comparison with the curved ones-were made based on the data collected from 19 men. The flow rate and pattern in the stented ureter were evaluated using computational fluid dynamics (CFD). According to the results, curved models reflecting the human anatomy seem to be more desirable in the CFD simulation of urine flow and must be good for evaluating the effect of geometrical variations in stent design on urine flow.


Asunto(s)
Modelos Biológicos , Peristaltismo/fisiología , Stents , Uréter/fisiología , Micción/fisiología , Orina/fisiología , Simulación por Computador , Análisis de Falla de Equipo , Humanos , Diseño de Prótesis , Reología/métodos , Uréter/cirugía
12.
Biomed Mater Eng ; 26 Suppl 1: S319-27, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26406019

RESUMEN

A double J stent has been used widely these days for patients with a ureteral stenosis or with renal stones and lithotripsy. The stent has multiple side holes in the shaft, which supply detours for urine flow. Even though medical companies produce various forms of double J stents that have different numbers and positions of side holes in the stent, the function of side holes in fluid dynamics has not been studied well. Here, the flow rate and pattern around the side holes of a double J stent were evaluated in curved models of a stented ureter based on the human anatomy and straight models for comparison. The total flow rate was higher in the stent with a greater number of side holes. The inflow and outflow to the stent through the side holes in the curved ureter was more active than in the straight ureter, which means the flow through side holes exists even in the ureter without ureteral stenosis or occlusion and even in the straight ureter. When the diameter of the ureter changed, the in-stent flow rate in the ureter did not change and the extraluminal flow rate was higher in the ureter with a greater diameter.


Asunto(s)
Modelos Biológicos , Stents , Obstrucción Ureteral/fisiopatología , Obstrucción Ureteral/terapia , Micción , Orina/fisiología , Simulación por Computador , Diseño Asistido por Computadora , Análisis de Falla de Equipo , Humanos , Diseño de Prótesis , Reología/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...