Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 278
Filtrar
1.
ACS Nano ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709870

RESUMEN

In Li metal batteries (LMBs), which boast the highest theoretical capacity, the chemical structure of the solid electrolyte interphase (SEI) serves as the key component that governs the growth of reactive Li. Various types of additives have been developed for electrolyte optimization, representing one of the most effective strategies to enhance the SEI properties for stable Li plating. However, as advanced electrolyte systems become more chemically complicated, the use of additives is empirically optimized. Indeed, their role in SEI formation and the resulting cycle life of LMBs are not well-understood. In this study, we employed cryogenic transmission electron microscopy combined with Raman spectroscopy, theoretical studies including molecular dynamics (MD) simulations and density functional theory (DFT) calculations, and electrochemical measurements to explore the nanoscale architecture of SEI modified by the most representative additives, lithium nitrate (LiNO3) and vinylene carbonate (VC), applied in a localized high-concentration electrolyte. We found that LiNO3 and VC play distinct roles in forming the SEI, governing the solvation structure, and influencing the kinetics of electrochemical reduction. Their collaboration leads to the desired SEI, ensuring prolonged cycle performance for LMBs. Moreover, we propose mechanisms for different Li growth and cycling behaviors that are determined by the physicochemical properties of SEI, such as uniformity, elasticity, and ionic conductivity. Our findings provide critical insights into the appropriate use of additives, particularly regarding their chemical compatibility.

2.
Biomarkers ; 29(4): 205-210, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38588595

RESUMEN

BACKGROUND: Currently available risk scores fail to accurately predict morbidity and mortality in patients with severe symptomatic aortic stenosis who undergo transcatheter aortic valve implantation (TAVI). In this context, biomarkers like matrix metalloproteinase-2 (MMP-2) and Galectin-3 (Gal-3) may provide additional prognostic information. METHODS: Patients with severe aortic stenosis undergoing consecutive, elective, transfemoral TAVI were included. Baseline demographic data, functional status, echocardiographic findings, clinical outcomes and biomarker levels were collected and analysed. RESULTS: The study cohort consisted of 89 patients (age 80.4 ± 5.1 years, EuroScore II 7.1 ± 5.8%). During a median follow-up period of 526 d, 28 patients (31.4%) died. Among those who died, median baseline MMP-2 (alive: 221.6 [170.4; 263] pg/mL vs. deceased: 272.1 [225; 308.8] pg/mL, p < 0.001) and Gal-3 levels (alive: 19.1 [13.5; 24.6] pg/mL vs. deceased: 25 [17.6; 29.5] pg/mL, p = 0.006) were higher than in survivors. In ROC analysis, MMP-2 reached an acceptable level of discrimination to predict mortality (AUC 0.733, 95% CI [0.62; 0.83], p < 0.001), but the predictive value of Gal-3 was poor (AUC 0.677, 95% CI [0.56; 0.79], p = 0.002). Kaplan-Meier and Cox regression analyses showed that patients with MMP-2 and Gal-3 concentrations above the median at baseline had significantly impaired long-term survival (p = 0.004 and p = 0.02, respectively). CONCLUSIONS: In patients with severe aortic stenosis undergoing transfemoral TAVI, MMP-2 and to a lesser extent Gal-3, seem to have additive value in optimizing risk prediction and streamlining decision-making.


Asunto(s)
Estenosis de la Válvula Aórtica , Biomarcadores , Galectina 3 , Metaloproteinasa 2 de la Matriz , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Metaloproteinasa 2 de la Matriz/sangre , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Biomarcadores/sangre , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/sangre , Galectina 3/sangre , Anciano de 80 o más Años , Anciano , Pronóstico , Galectinas , Proteínas Sanguíneas/análisis , Proteínas Sanguíneas/metabolismo
3.
Nano Lett ; 24(14): 4233-4240, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38557069

RESUMEN

This study represents the synthesis of a novel class of nanoparticles denoted as annular Au nanotrenches (AANTs). AANTs are engineered to possess embedded, narrow circular nanogaps with dimensions of approximately 1 nm, facilitating near-field focusing for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) via a surface-enhanced Raman scattering (SERS)-based immunoassay. Notably, AANTs exhibited an exceedingly low limit of detection (LOD) of 1 fg/mL for SARS-CoV-2 spike glycoproteins, surpassing the commercially available enzyme-linked immunosorbent assay (ELISA) by 6 orders of magnitude (1 ng/mL from ELISA). To assess the real-world applicability, a study was conducted on 50 clinical samples using an SERS-based immunoassay with AANTs. The results revealed a sensitivity of 96% and a selectivity of 100%, demonstrating the significantly enhanced sensing capabilities of the proposed approach in comparison to ELISA and commercial lateral flow assay kits.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Humanos , SARS-CoV-2 , Oro , COVID-19/diagnóstico , Inmunoensayo/métodos , Espectrometría Raman/métodos
4.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38588025

RESUMEN

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Estimación de Kaplan-Meier , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Riesgo , Alemania
5.
Emerg Infect Dis ; 30(4): 817-821, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38526320

RESUMEN

Orthohantaviruses cause hantavirus cardiopulmonary syndrome; most cases occur in the southwest region of the United States. We discuss a clinical case of orthohantavirus infection in a 65-year-old woman in Michigan and the phylogeographic link of partial viral fragments from the patient and rodents captured near the presumed site of infection.


Asunto(s)
Infecciones por Hantavirus , Orthohantavirus , Femenino , Humanos , Anciano , Michigan/epidemiología , Filogeografía , Síndrome
6.
Circ Cardiovasc Interv ; : e013608, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38529637

RESUMEN

BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.

7.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506737

RESUMEN

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Catéteres , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvulas Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
8.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506739

RESUMEN

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Microtomografía por Rayos X , Catéteres , Válvulas Cardíacas
9.
Artículo en Inglés | MEDLINE | ID: mdl-38467531

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly performed for the treatment of aortic stenosis. Computed tomography (CT) analysis is essential for pre-procedural planning. Currently available software packages for TAVR planning require substantial human interaction. We describe development and validation of an artificial intelligence (AI) powered software to automatically rend anatomical measurements and other information required for TAVR planning and implantation. METHODS: Automated measurements from 100 CTs were compared to measurements from three expert clinicians and TAVR operators using commercially available software packages. Correlation coefficients and mean differences were calculated to assess precision and accuracy. RESULTS: AI-generated annular measurements had excellent agreements with manual measurements by expert operators yielding correlation coefficients of 0.97 for both perimeter and area. There was no relevant bias with a mean difference of -0.07 mm and - 1.4 mm2 for perimeter and area, respectively. For the ascending aorta measured 5 cm above the annular plane, correlation coefficient was 0.95 and mean difference was 1.4 mm. Instruction for use-based sizing yielded agreement with the effective implant size in 87-88 % of patients for self-expanding valves (perimeter-based sizing) and in 88 % for balloon-expandable valves (area-based sizing). CONCLUSIONS: A fully automated software enables accurate and precise anatomical segmentation and measurements required for TAVR planning without human interaction and with high reliability.

11.
Virus Res ; 342: 199325, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38309472

RESUMEN

The COVID-19 pandemic caused by SARS-CoV-2 becomes a serious threat to global health and requires the development of effective antiviral therapies. Current therapies that target viral proteins have limited efficacy with side effects. In this study, we investigated the antiviral activity of MIT-001, a small molecule reactive oxygen species (ROS) scavenger targeting mitochondria, against SARS-CoV-2 and other zoonotic viruses in vitro. The antiviral activity of MIT-001 was quantified by RT-qPCR and plaque assay. We also evaluated the functional analysis of MIT-001 by JC-1 staining to measure mitochondrial depolarization, total RNA sequencing to investigate gene expression changes, and immunoblot to quantify protein expression levels. The results showed that MIT-001 effectively inhibited the replication of B.1.617.2 and BA.1 strains, Zika virus, Seoul virus, and Vaccinia virus. Treatment with MIT-001 restored the expression of heme oxygenase-1 (HMOX1) and NAD(P)H: quinone oxidoreductase 1 (NqO1) genes, anti-oxidant enzymes reduced by SARS-CoV-2, to normal levels. The presence of MIT-001 also alleviated mitochondrial depolarization caused by SARS-CoV-2 infection. These findings highlight the potential of MIT-001 as a broad-spectrum antiviral compound that targets for zoonotic RNA and DNA viruses, providing a promising therapeutic approach to combat viral infection.


Asunto(s)
COVID-19 , Infección por el Virus Zika , Virus Zika , Humanos , Animales , SARS-CoV-2 , Especies Reactivas de Oxígeno , Pandemias , Peces , Antivirales/farmacología
12.
Artículo en Inglés | MEDLINE | ID: mdl-38402954

RESUMEN

OBJECTIVES: High incidences of haemorrhagic fever with renal syndrome (HFRS) have been reported in the southern Republic of Korea (ROK). A distinct southern genotype of Orthohantavirus hantanense (HTNV) was identified in Apodemus agrarius chejuensis on Jeju Island. However, its association with HFRS cases in southern ROK remains elusive. We investigated the potential of the southern HTNV genotype as an etiological agent of HFRS. METHODS: Samples from 22 patients with HFRS and 193 small mammals were collected in the southern ROK. The clinical characteristics of patients infected with the southern HTNV genotype were analysed. Amplicon-based MinION sequencing was employed for southern HTNV from patients and rodents, facilitating subsequent analyses involving phylogenetics and genetic reassortment. RESULTS: High-throughput sequencing of HTNV exhibited higher coverage with a cycle of threshold value below 32, acquiring nearly whole-genome sequences from six patients with HFRS and seven A. agrarius samples. The phylogenetic pattern of patient-derived HTNV demonstrated genetic clustering with HTNV from Apodemus species on Jeju Island and the southern Korean peninsula, revealing genetic reassortment in a single clinical sample between the M and S segments. DISCUSSION: These findings imply that the southern HTNV genotype has the potential to induce HFRS in humans. The phylogenetic inference demonstrates the diverse and dynamic characteristics of the southern HTNV tripartite genomes. Therefore, this study highlights the significance of active surveillance and amplicon sequencing for detecting orthohantavirus infections. It also raises awareness and caution for physicians regarding the emergence of a southern HTNV genotype as a cause of HFRS in the ROK.

14.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38244892

RESUMEN

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Calcio , Resultado del Tratamiento , Estudios Retrospectivos , Diseño de Prótesis
15.
Struct Heart ; 8(1): 100226, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38283573

RESUMEN

Background: The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods: This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results: We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions: The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. ClinicalTrialsgov Identifier: NCT03752866.

16.
J Med Virol ; 96(1): e29401, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38235603

RESUMEN

Hepatitis E virus (HEV), an emerging zoonotic pathogen, poses a significant public health concern worldwide. Recently, rat HEV (Rocahepevirus ratti genotype C1; HEV-C1) has been reported to cause zoonotic infections and hepatitis in humans. Human infections with HEV-C1 are considered to be underestimated worldwide due to limited knowledge of transmission routes, genome epidemiology, and the risk assessment of zoonosis associated with these viruses. A total of 186 wild Norway rats (Rattus norvegicus) were collected from the Republic of Korea (ROK) between 2011 and 2021. The prevalence of HEV-C1 RNA was 8 of 180 (4.4%) by reverse-transcription polymerase chain reaction. We first reported three nearly whole-genome sequences of HEV-C1 newly acquired from urban rats in the ROK. Phylogenetic analysis demonstrated that Korea-indigenous HEV-C1 formed an independent genetic group with those derived from R. norvegicus rats in other countries, indicating geographical and genetic diversity. Our findings provide critical insights into the molecular prevalence, genome epidemiology, and zoonotic potential of Rocahepevirus. This report raises awareness of the presence of Rocahepevirus-related hepatitis E among physicians in the ROK.


Asunto(s)
Virus de la Hepatitis E , Hepatitis E , Animales , Ratas , Humanos , Virus de la Hepatitis E/genética , Filogenia , Hepatitis E/epidemiología , Hepatitis E/veterinaria , Zoonosis , ARN Viral/genética , República de Corea/epidemiología
17.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276659

RESUMEN

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

18.
J Med Virol ; 96(1): e29346, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38178580

RESUMEN

Orthohantaviruses, etiological agents of hemorrhagic fever with renal syndrome (HFRS) and hantavirus cardiopulmonary syndrome, pose a critical public health threat worldwide. Hantaan orthohantavirus (HTNV) outbreaks are particularly endemic in Gyeonggi Province in northern area of the Republic of Korea (ROK). Small mammals were collected from three regions in the Gyeonggi Province during 2017 and 2018. Serological and molecular prevalence of HTNV was 25/201 (12.4%) and 10/25 (40%), respectively. A novel nanopore-based diagnostic assay using a cost-efficient Flongle chip was developed to rapidly and sensitively detect HTNV infection in rodent specimens within 3 h. A rapid phylogeographical surveillance of HTNV at high-resolution phylogeny was established using the amplicon-based Flongle sequencing. In total, seven whole-genome sequences of HTNV were newly obtained from wild rodents collected in Paju-si (Gaekhyeon-ri) and Yeoncheon-gun (Hyeonga-ri and Wangnim-ri), Gyeonggi Province. Phylogenetic analyses revealed well-supported evolutionary divergence and genetic diversity, enhancing the resolution of the phylogeographic map of orthohantaviruses in the ROK. Incongruences in phylogenetic patterns were identified among HTNV tripartite genomes, suggesting differential evolution for each segment. These findings provide crucial insights into on-site diagnostics, genome-based surveillance, and the evolutionary dynamics of orthohantaviruses to mitigate hantaviral outbreaks in HFRS-endemic areas in the ROK.


Asunto(s)
Virus Hantaan , Fiebre Hemorrágica con Síndrome Renal , Orthohantavirus , Animales , Filogenia , Virus Hantaan/genética , Orthohantavirus/genética , Roedores , Mamíferos , República de Corea/epidemiología
19.
Clin Res Cardiol ; 113(1): 38-47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37115228

RESUMEN

BACKGROUND: New-generation self-expanding transcatheter aortic heart valves (THV) were designed to overcome technical constraints of their preceding generations. We sought to compare the efficacy and safety of the self-expanding ACURATE neo2 (Neo2) versus Evolut PRO (PRO) devices. METHODS: Seven hundred nine patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with either Neo2 (n = 496) or PRO (n = 213) were included. Propensity score matching (PSM) was performed to account for differences in baseline characteristics. In-hospital and 30-day clinical outcomes were evaluated according to Valve Academic Research Consortium-3 criteria. RESULTS: Baseline characteristics were comparable between both groups after PSM (Neo2: n = 155, Evolut Pro: n = 155). Technical success rates were high in both groups (Neo2: 94.8% vs PRO: 97.4%; p = 0.239). Need for permanent pacemaker implantation was less frequent with Neo2 compared with PRO (7.5% vs 20.6%; p = 0.002), whereas major vascular complications were more frequent with Neo2 (Neo2: 11.6% vs PRO: 4.5%; p = 0.022). Intended valve performance at discharge was high in both groups without relevant differences among groups (Neo2: 97.4% vs. 95.3%; p = 0.328). CONCLUSIONS: Short-term outcomes after TAVI using latest-generation self-expanding THV were excellent, with overall low rates of adverse events. However, Neo2 was associated with lower pacemaker rates and reduced the prevalence of moderate-severe paravalvular leakage. Transprosthetic gradients after TAVI were higher with Neo2 compared with PRO.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...