Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Ann Thorac Surg ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38750687

RESUMEN

BACKGROUND: Aggressive resection/exclusion of the primary entry in the descending aorta remains controversial in older patients with acute type A aortic dissection (ATAAD). We investigated the effect of residual primary entry in the descending aorta in younger and older groups. METHODS: Patients with ATAAD who underwent emergency surgery (n=1103) were divided into younger (< 70 years; n=681) and older (≥ 70 years; n=422) cohorts. Each cohort was further divided into groups with or without residual primary entry in the descending aorta. After propensity score matching, 179 and 71 matched pairs were obtained in the younger and older cohorts, respectively. Surgical outcomes were compared between the residual and non-residual groups in each age cohort. RESULTS: In the younger cohort, the cumulative incidence rate of distal aortic events was significantly higher in the residual than in the non-residual group (10-year: 35 [95% CI, 27-44] % vs. 22 [15-31] %, P=.001). However, in the older group, residual or non-residual primary entry did not affect the rates (10-year:11 [5-20] % vs. 9 [4-17] %, P=.75). Multivariate analysis identified age < 70 years (P<.001; HR, 2.188; 95% CI, 1.493, 3.205) and residual primary entry at the descending aorta (P<.001; HR, 2.142; 95% CI, 1.559-2.943) as significant predictors for distal aortic events. CONCLUSIONS: Aggressive resection/exclusion of the primary entry in the descending aorta should be considered for patients aged < 70 years to avoid distal aortic events; however, it might not always be appropriate for the older patients ≥ 70 years.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38498834

RESUMEN

Computational fluid dynamics was performed to simulate haemodynamics of type B aortic dissection complicated by mesenteric malperfusion caused by dynamic obstruction in a 70-year-old man. Streamline analysis showed disappearance of antegrade flow in the false lumen of the descending aorta and attenuation of intermittent flap-induced disruption of visceral vessel perfusion after entry coverage. Quantitative analysis showed endovascular repair increased perfusion volume of the coeliac artery and superior mesenteric artery by 55.6% and 77.4%, respectively. Entry closure with thoracic endovascular prosthesis improved mesenteric malperfusion by attenuating the intermittent flap-induced perfusion disruption.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38280667

RESUMEN

OBJECTIVE: The predissection aortic diameter is the best reference for determining the size of the frozen elephant trunk in aortic dissection. We aimed to develop a new prediction method to estimate the predissection diameter of proximal descending aorta. Furthermore, we evaluated the accuracy of the estimated predissection proximal descending aortic diameters calculated using 3 prediction methods. METHODS: A total of 39 patients with acute type A aortic dissection who underwent predissection computed tomography were included in derivation sets. We measured the aortic dimensions at 3 levels of the proximal descending aorta: 5, 10, and 15 cm from zone 2. We developed a new prediction method-postdissection aortic diameter divided by 1.13 (AoDNew factor)-and estimated the predissection aortic diameter using the new and previously proposed methods by Rylski (AoDRylski) and Yamauchi (EquationYamauchi). Furthermore, we validated the new prediction method using a validation dataset with 24 patients. RESULTS: The rate of bias ≤2 mm was significantly greater with EquationYamauchi and AoDNew factor than with AoDRylski in the derivation group at each level of the proximal descending aorta (P < .001). In the validation group, the rate of bias ≤2 mm was significantly greater with EquationYamauchi and AoDNew factor than with AoDRylski at 10 cm and 15 cm from zone 2 (10 cm: P = .014, 15 cm: P < .001). CONCLUSIONS: These results suggest that the new prediction method can be used as a simple and accurate estimation method for the predissection aortic diameter at the proximal descending aorta.

4.
J Artif Organs ; 27(1): 23-31, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36738330

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the effect of decalcification and existence of stent at the aortic annulus on mitral annular motion after surgery. METHODS: Patients receiving Inspiris (Edwards, CA, USA, n = 117), Intuity (Edwards, n = 36), Perceval (Corcym, London, UK, n = 36), Evolut (Medtronics, MN, USA, n = 81) and Sapien 3 (Edwards, n = 250) were included in the study. Mitral annular motion was evaluated by E', using tissue doppler imaging. RESULTS: After surgery, a significant increase in E' was observed in patients receiving Inspiris (Before: 4.2 ± 1.21 cm/s vs. Discharge: 5.0 ± 1.23 cm/s, p < 0.001). Mid-term echocardiogram performed at 11.8 ± 2.2 months after the surgery, showed a significant increase in E' in patients receiving Inspiris (Before: 4.2 ± 1.21 cm/s vs. Mid-term: 5.2 ± 1.20 cm/s, p < 0.001) and Perceval (Before: 3.9 ± 1.34 cm/s vs. Mid-term: 4.5 ± 1.24 cm/s, p = 0.008). Univariable analysis showed a higher increase in E' in patients with decalcified annulus compared to those without decalcified annulus (Decalcification: 0.15 ± 1.321 cm/s vs. No Decalcification: 0.66 ± 1.420 cm/s, p < 0.001). Multivariable analysis showed that balloon-expandable stent (ß = - 0.6960, p < 0.001) and self-expanding stent (r = - 0.3592, p = 0.042) were independent limiting factors for an increase in E' at discharge. However, balloon-expandable stent (ß = - 0.8382, p < 0.001), and not self-expanding stent (ß = - 0.3682, p = 0.089), was a remaining independent factor associated with E' at mid-term follow-up. CONCLUSIONS: Decalcification was associated with improvement in E' after surgery. Balloon-expandable stent was an independent limiting factor for improvement in E' up to 1 year after the surgery, while self-expanding stent was not a significant factor after 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Stents , Resultado del Tratamiento , Diseño de Prótesis
5.
J Artif Organs ; 27(1): 32-40, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36991242

RESUMEN

Mosaic valve shows higher pressure gradient after aortic valve replacement compared to other same size labeled prostheses in postoperative echocardiogram. The purpose of this study was to evaluate the mid-term echocardiogram findings and long-term clinical outcomes of patients receiving a 19 mm Mosaic. Forty-six aortic stenosis patients receiving 19 mm Mosaic and 112 patients receiving either 19 mm Magna or Inspiris, who underwent mid-term follow-up echocardiogram were included in the study. Mid-term hemodynamic measurements evaluated by trans-thoracic echocardiogram and long-term outcomes were compared. Patients receiving Mosaic were significantly older (Mosaic: 76 ± 5.1 years vs. Magna/Inspiris: 74 ± 5.5 years, p = 0.046) and had smaller body surface area (Mosaic: 1.40 ± 0.114m2 vs. Magna/Inspiris: 1.48 ± 0.143m2, p < 0.001). There were no significant differences in comorbidities and medications. Post-operative echocardiogram performed at 1 week after the surgery showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 38 ± 13.5 mmHg vs. Magna/Inspiris: 31 ± 10.7 mmHg, p = 0.002). Furthermore, mid-term echocardiogram follow-up performed at median duration of 53 ± 14.9 months after the surgery continuously showed higher maximum pressure gradient in patients receiving Mosaic (Mosaic: 45 ± 15.6 mmHg vs. Magna/Inspiris: 32 ± 13.0 mmHg, p < 0.001). However, there were no significant difference in changes in left ventricular mass from baseline in both groups. Kaplan-Meyer curve also showed no difference in long-term mortality and major adverse cardiac and cerebrovascular event between the two groups. Although the pressure gradient across the valve evaluated by echocardiogram was higher in 19 mm Mosaic compared to 19 mm Magna/Inspiris, there were no significant differences in left ventricular remodeling and long-term outcomes between the two groups.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Remodelación Ventricular , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Hemodinámica , Resultado del Tratamiento , Diseño de Prótesis
6.
Kyobu Geka ; 76(11): 924-927, 2023 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-38056949

RESUMEN

A 44-year old man with a history of Stanford type B acute aortic dissection was admitted for the treatment of acute aortic dissection. Computed tomography( CT) scan showed a descending entry-type non-A non-B aortic dissection with a maximum diameter of 65 mm occurring in a patient with Edwards typeⅢ right aortic arch whose left subclavian artery was obliterated. The patient was initially treated conservatively and underwent one-stage extended aortic repair from the ascending aorta to the descending thoracic aorta via median sternotomy 22 days after the symptom onset. Although the patient suffered from right empyema postoperatively, he was discharged from the hospital on postoperative day 64 after 4 weeks antibiotics therapy. The patient was also complicated by right recurrent nerve palsy, hoarseness improved over the 8 months after surgery.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Masculino , Humanos , Adulto , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/cirugía , Procedimientos Quirúrgicos Vasculares , Esternotomía , Stents , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento
7.
J Cardiovasc Dev Dis ; 10(7)2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37504549

RESUMEN

BACKGROUND: The incidence of delirium is high in older patients undergoing cardiovascular surgery with cardiopulmonary bypass (CPB). Intraoperative tissue hypoperfusion and re-reperfusion injury, which generate reactive oxygen species (ROS), are suggested to induce delirium. Ascorbic acid is an excellent antioxidant and may reduce organ damage by inhibiting the production of ROS. This prospective observational study aimed to measure pre- and postoperative plasma ascorbic acid levels and examine their association with delirium. METHODS: Patients older than 70 years of age scheduled for elective cardiovascular surgery using CPB were enrolled. From September 2020 to December 2021, we enrolled 100 patients, and the data of 98 patients were analyzed. RESULTS: In total, 31 patients developed delirium, while 67 did not. Preoperative plasma ascorbic acid levels did not differ between the non-delirium and delirium groups (6.0 ± 2.2 vs. 5.5 ± 2.4 µg/mL, p = 0.3). Postoperative plasma ascorbic acid levels were significantly different between the groups (2.8 [2.3-3.5] vs. 2.3 [1.6-3.3] µg/mL, p = 0.037). CONCLUSIONS: In patients who undergo cardiovascular surgery with CPB, lower postoperative plasma ascorbic acid levels may be associated with the development of delirium.

8.
Gen Thorac Cardiovasc Surg ; 71(4): 232-239, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35999411

RESUMEN

OBJECTIVE: Preoperative assessment of frailty is important for predicting postoperative outcomes. This study investigated the association between frailty and late outcomes among patients who underwent thoracic aortic surgery via median sternotomy. METHODS: A total of 1010 patients underwent thoracic aortic surgery via median sternotomy between April 2008 and December 2016. Patients < 65 years of age, those who underwent urgent or emergent surgery, and those with incomplete data were excluded; as such, 374 patients were ultimately included in the present study. Frailty was evaluated using an index comprising history of dementia, body mass index < 18.5 kg/m2, and hypoalbuminemia. A frailty score from 0 to 3 was determined by assigning 1 point for each criterion met. Frailty was defined as a score ≥ 1. Patients were categorized into of 2 groups: frail (n = 52) and non-frail (n = 322). The mean follow-up was 6.1 ± 3.1 years. RESULTS: Overall in-hospital mortality did not differ between the frail and non-frail groups. However, the incidence of re-exploration for bleeding and discharge to a health care facility was higher in the frail group than in the non-frail group. Multivariable analysis revealed that preoperative frailty was an independent predictor of late mortality during follow-up [hazard ratio 3.71 (95% confidence interval 2.16-6.37); P < 0.001]. CONCLUSION: Preoperative frailty was associated with late mortality after thoracic aortic surgery. Assessment of preoperative frailty using a simple frailty index may be useful in the decision-making process for elderly patients.


Asunto(s)
Fragilidad , Humanos , Anciano , Fragilidad/complicaciones , Fragilidad/diagnóstico , Anciano Frágil , Factores de Riesgo , Esternotomía/efectos adversos , Resultado del Tratamiento , Evaluación Geriátrica , Estudios Retrospectivos , Complicaciones Posoperatorias/etiología , Medición de Riesgo
9.
J Card Surg ; 37(9): 2706-2712, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35726649

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the changes in mitral annular motion after surgery in patients with aortic stenosis. METHODS: Patients receiving Edwards (Edwards) valves were included in the study. Echocardiographic findings were compared among the three treatments postoperatively, at discharge, and at 1 year after the surgery. Mitral annular motion was evaluated by e prime, using tissue doppler imaging. RESULTS: There were 111 patients receiving Inspiris, 30 patients receiving Intuity and 241 patients receiving Sapien 3. The patients receiving Sapien 3 were significantly older, (Inspiris: 71 ± 6.7 years vs. Intuity: 75 ± 5.2 years vs. Sapien 3: 84 ± 5.1 years, p < .001), and prevalence of hemodialysis were significantly higher in patients receiving Intuity (Inspiris: 11.7% vs. Intuity: 46.7% vs. Sapien 3: 0.0%, p < .001). There was a significant improvement in mean pressure gradient in all groups (Inspiris: 55 ± 21.2-13 ± 5.2 mmHg, p < .001; Intuity: 48 ± 17.6-12 ± 4.9 mmHg, p < .001, Sapien 3: 55 ± 16.6-14 ± 5.2 mmHg, p < .001). Decalcification was associated with increase in e prime after surgery (no decalcification: 0.10 ± 1.280 cm/s vs. decalcification: 0.68 ± 1.405 cm/s, p < .001) Further, existence of stent was associated with less increase in e prime after surgery (no stent: 0.83 ± 1.210 cm/s vs. stent: 0.10 ± 1.356; p < .001). Multivariate analysis showed that existence of stent but not decalcification of the aortic valve was independently associated with changes in e prime after surgery (ß: -.4679, 95% confidence interval: -0.93389 to -0.00200, p = .049). CONCLUSIONS: Although improvement in pressure gradient was achieved in all treatments, existence of stent inhibited mitral annular motion after surgery.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Diseño de Prótesis , Resultado del Tratamiento
10.
Artículo en Inglés | MEDLINE | ID: mdl-35552699

RESUMEN

OBJECTIVES: We aimed to determine whether non-A non-B aortic dissection (AD) differs in morphologic and haemodynamic properties from type B AD. METHODS: We simulated and compared haemodynamics of patients with acute type B or acute non-A non-B AD by means of computational fluid dynamics. Wall pressure and wall shear stress (WSS) in both the true lumen (TL) and false lumen (FL) at early, mid- and late systole were evaluated. Morphology, WSS and the FL/TL wall pressure ratio were compared between groups. RESULTS: Nineteen patients (type B, n = 7; non-A non-B, n = 12) were included. The median age (51 [46, 67] vs 53 [50, 63] years; P = 0.71) and a complicated course (14% vs 33%; P = 0.6) did not differ between the type B group and the non-A non-B group. However, the median entry tear width was increased in the non-A non-B group (9.7 [7.3, 12.7] vs 16.3 [11.9, 24.9] mm; P = 0.010). Streamlines showed, in patients with non-A non-B AD, blood from the TL flowed into the FL via the entry tear. Prevalence of a FL/TL wall pressure ratio >1.0 (type B versus non-A non-B) at early, mid- and late systole was 57% vs 83% (P = 0.31), 43% vs 83% (P = 0.13) and 57% vs 75% (P = 0.62), respectively. WSS did not differ between the groups. CONCLUSIONS: The increased FL/TL wall pressure ratio observed during systole in non-A non-B AD may beget a complicated presentation.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Disección Aórtica , Procedimientos Endovasculares , Hemodinámica , Humanos , Hidrodinámica , Modelos Cardiovasculares
11.
J Card Surg ; 37(8): 2338-2347, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35545926

RESUMEN

OBJECTIVE: Although hemodilution during hypothermic cardiopulmonary bypass (CPB) had been thought to improve microcirculation and reduce blood viscosity, there has been no report investigating the effect of low nadir hematocrit (Hct) values caused by severe hemodilution on the surgical outcomes of patients with acute type A aortic dissection (ATAAD). METHODS: We retrospectively reviewed 112 consecutive patients who emergently underwent emergency surgical repair of ATAAD at our institution. The patients were classified into the high Hct (nadir Hct ≥ 21% during CPB; n = 51) and low Hct (nadir Hct < 21% during CPB; n = 61) groups. After propensity score matching of preoperative characteristics, surgical outcomes were compared between the groups. RESULTS: Although there was no difference in the surgical procedure, longer CPB time and more blood transfusion during surgery were needed in the low Hct group than in the high Hct group. After surgery, estimated glomerular filtration rate was significantly lower (p = .015), lactaic acid was higher (p = .045), and intubation time was longer (p = .018) in the low Hct group than in the high Hct group, although there was no difference in hospital mortality between the groups. The AUC of the nadir Hct during CPB as a prognostic indicator of prolonged postoperative ventilator support was 0.8, with the highest accuracy at 16.7% (sensitivity 88%, specificity 76.9%). In all cohorts, female sex was an independent risk factor for a lower nadir Hct value of <21% during CPB. CONCLUSION: A lower nadir Hct value of <21% during CPB may be associated with postoperative renal dysfunction and prolonged ventilator support in patients with ATAAD.


Asunto(s)
Disección Aórtica , Puente Cardiopulmonar , Disección Aórtica/etiología , Disección Aórtica/cirugía , Puente Cardiopulmonar/efectos adversos , Femenino , Hematócrito , Hemodilución , Humanos , Estudios Retrospectivos
12.
Ann Vasc Dis ; 15(1): 37-44, 2022 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-35432643

RESUMEN

Objective: To examine early histologic changes in the aorta exposed to bicuspid flow. Material and Methods: A porcine bicuspid aortopathy model was developed by suturing aortic cusps. Of nine pigs, eight underwent sham surgery (n=3) or bicuspidalization (n=5); one was used as an intact control. Wall shear stress (WSS) was assessed by computational fluid dynamics (CFD). Animals were exposed to normal or bicuspid flow for 48 h and were then euthanized for histologic examinations. Results: No animal died intraoperatively. One animal subjected to bicuspidalization died of respiratory failure during postoperative imaging studies. Echocardiography showed the aortic valve area decreased from 2.52±1.15 to 1.21±0.48 cm2 after bicuspidalization, CFD revealed increased maximum WSS (10.0±5.2 vs. 54.0±25.7 Pa; P=0.036) and percentage area of increased WSS (>5 Pa) in the ascending aorta (30.3%±24.1% vs. 81.3%±13.4%; P=0.015) after bicuspidalization. Hematoxylin-eosin staining and transmission electron microscopy showed subintimal edema and detached or degenerated endothelial cells following both sham surgery and bicuspidalization, regardless of WSS distribution. Conclusion: A bicuspid aortic valve appears to increase aortic WSS. The endothelial damage observed might have been related to non-pulsatile flow (cardiopulmonary bypass). Chronic experiments are needed to clarify the relationship between hemodynamic stress and development of bicuspid aortopathy.

13.
Ann Biomed Eng ; 50(8): 951-963, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35471673

RESUMEN

The coculture of vascular endothelial cells (ECs) on collagen gels containing smooth muscle cells (SMCs) has been carried out to investigate cellular interactions associated with blood vessel pathophysiology under wall shear stress (WSS) conditions. However, due to a lack of gel stiffness, the previous collagen gel coculture constructs are difficult to use for pathologic higher WSS conditions. Here, we newly constructed a coculture model with centrifugally compressed cell-collagen combined construct (C6), which withstands higher WSS conditions. The elastic modulus of C6 was approximately 6 times higher than that of the uncompressed collagen construct. The level of α-smooth muscle actin, a contractile SMC phenotype marker observed in healthy arteries, was elevated in C6 compared with that of the uncompressed construct, and further increased by exposure to a physiological level WSS of 2 Pa, but not by a pathological level of 20 Pa. WSS conditions of 2 and 20 Pa also induced different expression ratios of matrix metalloproteinases and their inhibitors in the C6 coculture model but did not in monocultured ECs and SMCs. The C6 coculture model will be a powerful tool to investigate interactions between ECs and SMCs under pathologically high WSS conditions.


Asunto(s)
Células Endoteliales , Miocitos del Músculo Liso , Células Cultivadas , Técnicas de Cocultivo , Colágeno/metabolismo , Células Endoteliales/metabolismo , Estrés Mecánico
15.
PLoS One ; 17(2): e0263881, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35148346

RESUMEN

Aortic calcification in the tunica media is correlated with aortic stiffness, elastin degradation, and wall shear stress. The study aim was to determine if aortic calcifications influence disease progression in patients with acute type A aortic dissection (ATAAD). We retrospectively reviewed a total of 103 consecutive patients who had undergone surgery for ATAAD at our institution between January 2009 and December 2019. Of these, 85 patients who had preoperatively undergone plain computed tomography angiography (CTA) for evaluation of their aortic calcification were included. Moreover, we assessed the progression of aortic dissection after surgery via postoperative CTA. Using a classification and regression tree to identify aortic Agatston score thresholds predictive of disease progression, the patients were classified into high-score (Agatston score ≥ 3344; n  =   36) and low-score (<3344; n  =   49) groups. Correlations between aortic Agatston scores and CTA variables were assessed. Higher aortic Agatston scores were significantly correlated with the smaller distal extent of aortic dissection (p < 0.001), larger true lumen areas of the ascending (p  =  0.009) and descending aorta (p =   0.002), and smaller false lumen areas of the descending aorta (p =  0.028). Patients in the high-score group were more likely to have DeBakey type II dissection (p =  0.001) and false lumen thrombosis (p  =  0.027) than those in the low-score group, thereby confirming the correlations. Aortic dissection in the high-score group was significantly less distally extended (p < 0.001). A higher aortic Agatston score correlates with the larger true lumen area of the ascending and descending aorta and the less distal progression of aortic dissection in patients with ATAAD. Interestingly, the findings before and after surgery were consistent. Hence, aortic Agatston scores are associated with aortic dissection progression and may help predict postoperative residual dissected aorta remodeling.


Asunto(s)
Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Angiografía por Tomografía Computarizada/métodos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/cirugía , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Ecocardiografía , Femenino , Humanos , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios , Periodo Preoperatorio , Estudios Retrospectivos , Resultado del Tratamiento
16.
Surg Today ; 52(3): 431-440, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34724105

RESUMEN

PURPOSE: We investigated factors contributing to coagulopathy in patients with acute type A aortic dissection (ATAAD) and coagulopathy's influence on patient outcomes. METHODS: We grouped 420 patients who underwent ATAAD repair-none under anticoagulation therapy or with liver disease-by the prothrombin time-international normalized ratio (PT-INR) at admission: < 1.2 (no coagulopathy, n = 371), 1.2-1.49 (mild coagulopathy, n = 33), or ≥ 1.5 (severe coagulopathy, n = 16). We then compared the clinical presentation, dissection morphology, and outcomes among the groups. We assessed the PT-INR in relation to the preoperative hemodynamics and searched for factors predictive of a PT-INR ≥ 1.2. RESULTS: The transfusion volume and operation time were increased among patients with coagulopathy (P < 0.05). The in-hospital mortality (15.2-37.5% vs. 5.1%, P < 0.001) and 5-year survival (61.1-74.4% vs. 87.6%) were relatively poor for these patients. The median PT-INR was 1.03 (0.97-1.1) for patients with stable hemodynamics (n = 318), 1.11 (1.02-1.21) for those in shock (blood pressure < 80 mmHg) not given cardiopulmonary resuscitation (CPR) (n = 81), and 1.1 (1.0-1.54) for those in shock given CPR (n = 21) (P < 0.001). A multivariable analysis identified shock (P < 0.001), a partially thrombosed false lumen (P = 0.006), and mesenteric malperfusion (P = 0.016) as predictive variables. CONCLUSIONS: Shock, a partially thrombosed false lumen, and mesenteric malperfusion appear to be predictive of dissection-related coagulopathy, which influences outcomes negatively.


Asunto(s)
Disección Aórtica , Trastornos de la Coagulación Sanguínea , Disección Aórtica/cirugía , Trastornos de la Coagulación Sanguínea/etiología , Humanos , Relación Normalizada Internacional , Tiempo de Protrombina , Estudios Retrospectivos , Resultado del Tratamiento
17.
J Artif Organs ; 25(3): 238-244, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34727259

RESUMEN

Rapid deployment valve has expanded surgical indication for high-risk patients with aortic stenosis despite its accommodated risk for conduction disorder (CD). The purpose of this study was to evaluate the degree of oversizing in association with postoperative CD. During June 2019 to September 2021, 25 patients underwent aortic valve replacement with Edwards INTUITY. Device size selection was evaluated intraoperatively using provided sizers. Oversizing was evaluated retrospectively by measuring the difference of the dimension of the annulus and left ventricular outflow tract (LVOT) compared to the dimensions of the device used by preoperative-computed tomography. Although there was no incidence of pacemaker implantation, seven patients (28.0%) experienced CD after surgery. There was no difference in device area and annulus area (CD: - 37 ± 22.7 mm2 vs. no CD: - 56 ± 63.6 mm2, p = 0.47), and device circumference and annulus circumference (CD: - 4.4 ± 2.77 mm vs. no CD: - 6.9 ± 5.60 mm, p = 0.26) in patients with and without CD. However, there was a significant difference in area of the device skirt and sub-annular area at the LVOT (CD: 114 ± 28.4 mm2 vs. no CD: - 8 ± 80.0 mm2, p < 0.001), and circumference of device skirt and the LVOT (CD: 3.9 ± 2.08 mm vs. no CD: - 4.6 ± 5.24 mm, p < 0.001) between the two groups. Receiver operating characteristic curve analysis showed that an area difference of 77.7 mm2 and circumference difference of 0.91 mm at LVOT were associated with postoperative CD with specificities of 0.83, 0.78 and sensitivity of 1.0, 1.0, respectively. Preoperative measurement of the LVOT may be useful in evaluating the risk of postoperative CD in patients receiving rapid deployment valve.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Prótesis Valvulares Cardíacas/clasificación , Prótesis Valvulares Cardíacas/normas , Humanos , Diseño de Prótesis , Curva ROC , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
18.
J Artif Organs ; 25(2): 132-139, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34665354

RESUMEN

Negative impact of prosthesis-patient mismatch on long-term survival after valve replacement has been reported. However, the effect of prosthesis-patient mismatch after bioprosthetic mitral valve replacement has not yet been well examined. The purpose of this study was to investigate the effect of prosthesis-patient mismatch on late outcomes after bioprosthetic mitral valve replacement for mitral regurgitation. A total of 181 patients underwent bioprosthetic mitral valve replacement between April 2008 and December 2016. After excluding patients with mitral stenosis and those with incomplete data, 128 patients were included in the study. Postoperative transthoracic echocardiography was performed before discharge for all patients and the effective orifice area of bioprosthetic mitral valve was calculated using the formula: 220/pressure half-time, and the effective orifice area index was calculated by the formula: effective orifice area/body surface area. Prosthesis-patient mismatch was defined as a postoperative effective orifice area index ≤ 1.2 cm2/m2. The characteristics and outcomes were compared between the groups. There were 34 patients (26.6%) with prosthesis-patient mismatch and 94 patients (73.4%) without prosthesis-patient mismatch. There were no significant differences in the in-hospital mortality and morbidities. Multivariable analysis showed that prosthesis-patient mismatch was an independent predictor of late mortality (hazard ratio 3.38; 95% confidence interval 1.69-6.75; p = 0.001) and death from heart failure (hazard ratio 31.03, 95% confidence interval 4.49-214.40, p < 0.001). Prosthesis-patient mismatch at discharge after mitral valve replacement for mitral regurgitation was associated with long-term mortality and death from heart failure.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Aórtica/cirugía , Insuficiencia Cardíaca/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
19.
Eur J Cardiothorac Surg ; 61(3): 625-634, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-34431991

RESUMEN

OBJECTIVES: Transcatheter aortic valve replacement is known to be associated with improved haemodynamics in patients with aortic stenosis and a small aortic annulus. However, limited benchmark data are available regarding the long-term outcomes in patients treated with surgical aortic valve replacement (SAVR). We investigated the long-term outcomes of SAVR using a 19-mm bioprosthesis. METHODS: This study included consecutive patients who underwent SAVR using a 19-mm bioprosthesis at our hospital between 2008 and 2012. RESULTS: In a total of 132 patients, moderate and severe prosthesis-patient mismatch occurred in 36 (27.3%) and 7 patients (5.3%), respectively. The median follow-up period was 7.7 years. The overall 5- and 10-year survival rates were 79.4% and 52.9%, respectively. The 5- and 10-year freedom from major adverse valve-related events rates were 89.6% and 74.2%, respectively. Neither moderate nor severe prosthesis-patient mismatch was associated with late mortality, major adverse valve-related events or heart failure. Follow-up echocardiographic data were obtained at a median interval of 4.8 years in 80% of patients who survived ≥6 months postoperatively. Follow-up echocardiographic data showed a significantly increased left ventricular ejection fraction, decreased mean transvalvular/transprosthetic pressure gradients and a decreased mean left ventricular mass. At follow-up, we observed moderate or severe haemodynamic structural valve deterioration in 17 patients; however, structural valve deterioration did not affect late survival or freedom from major adverse valve-related events rates, or heart failure. CONCLUSIONS: SAVR using the 19-mm bioprosthesis was associated with satisfactory long-term clinical and haemodynamic outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
20.
Interact Cardiovasc Thorac Surg ; 34(4): 652-659, 2022 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-34871404

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the changes in pulse wave velocity (PWV) after aortic arch repair and to evaluate possible perioperative factors associated with an increase in PWV. METHODS: Eighty-nine patients with preoperative and postoperative PWV measurements who underwent surgical treatment for true aortic arch aneurysm were included in the study. The patients were treated by prosthetic graft replacement with or without the frozen elephant trunk technique or by hybrid surgery with a stent graft. Changes in PWV and perioperative factors were evaluated. RESULTS: Fifty-one patients were treated by prosthetic graft replacement; 22 patients were treated with the frozen elephant trunk procedure; and 16 patients were treated by hybrid surgery. A significant increase in PWV was observed in patients undergoing surgical treatment for aortic arch aneurysm regardless of the types of operations performed (all treatments: before, 1797 ± 397.8 cm/s vs after, 2061 ± 600.4 cm/s, P < 0.001; graft replacement: before, 1769 ± 398.1 cm/s vs after, 1895 ± 459.0 cm/s, P = 0.004; frozen elephant trunk procedure: before, 1911 ± 461.9 cm/s vs after 2307 ± 826.9 cm/s, P = 0.005; hybrid surgery: before, 1732 ± 273.3 cm/s vs after, 2254 ± 484.6 cm/s, P < 0.001). Differences in PWV were largest in patients treated with hybrid surgery and lowest in those treated with graft replacement (P = 0.002). In univariate analysis, an increase in PWV was positively correlated with treatment length (r = 0.41; P < 0.001); the use of a postoperative beta blocker was associated with a smaller increase in postoperative PWV (with: 165.0 ± 371.92 cm/s vs without: 439.4 ± 530.38 cm/s, P = 0.005). Multivariate analysis suggested that treatment length (coefficient 3.31, 95% confidence interval 0.056-6.562, P = 0.046) and postoperative beta blocker (coefficient -220.08, 95% confidence interval -401.972 to -38.183, P = 0.018) were factors independently associated with changes in PWV. CONCLUSIONS: There was a significant increase in PWV after aortic arch repair. Treatment length and use of postoperative beta blockers were factors associated with changes in postoperative PWV. Minimizing the treatment length and using postoperative beta blockers may attenuate the effects of prostheses on postoperative PWV.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Humanos , Análisis de la Onda del Pulso , Stents , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...