Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Appl Physiol ; 118(3): 647-656, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29353321

RESUMEN

Criterion data for total energy expenditure (TEE) in elite rugby are lacking, which prediction equations may not reflect accurately. This study quantified TEE of 27 elite male rugby league (RL) and rugby union (RU) players (U16, U20, U24 age groups) during a 14-day in-season period using doubly labelled water (DLW). Measured TEE was also compared to estimated, using prediction equations. Resting metabolic rate (RMR) was measured using indirect calorimetry, and physical activity level (PAL) estimated (TEE:RMR). Differences in measured TEE were unclear by code and age (RL 4369 ± 979; RU 4365 ± 1122; U16, 4010 ± 744; U20, 4414 ± 688; U24, 4761 ± 1523 Kcal day- 1). Differences in PAL (overall mean 2.0 ± 0.4) were unclear. Very likely differences were observed in RMR by code (RL 2366 ± 296; RU 2123 ± 269 Kcal day- 1). Differences in relative RMR between U20 and U24 were very likely (U16, 27 ± 4; U20, 23 ± 3; U24, 26 ± 5 Kcal kg- 1 day- 1). Differences were observed between measured and estimated TEE, using Schofield, Cunningham and Harris-Benedict equations for U16 (187 ± 614, unclear; - 489 ± 564, likely and - 90 ± 579, unclear Kcal day- 1), U20 (- 449 ± 698, likely; - 785 ± 650, very likely and - 452 ± 684, likely Kcal day- 1) and U24 players (- 428 ± 1292; - 605 ± 1493 and - 461 ± 1314 Kcal day- 1, all unclear). Rugby players have high TEE, which should be acknowledged. Large inter-player variability in TEE was observed demonstrating heterogeneity within groups, thus published equations may not appropriately estimate TEE.


Asunto(s)
Calorimetría/métodos , Metabolismo Energético , Fútbol Americano/fisiología , Adolescente , Calorimetría/normas , Óxido de Deuterio/farmacocinética , Humanos , Masculino , Isótopos de Oxígeno/farmacocinética , Adulto Joven
3.
Int J Sports Med ; 33(1): 18-25, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22095324

RESUMEN

This study assessed the reproducibility of performance and selected metabolic variables during a variable high-intensity endurance cycling test. 8 trained male cyclists (age: 35.9 ± 7.7 years, maximal oxygen uptake: 54.3 ± 3.9 mL·kg - 1·min - 1) completed 4 high-intensity cycling tests, performed in consecutive weeks. The protocol comprised: 20 min of progressive incremental exercise, where the power output was increased by 5% maximal workload (Wmax) every 5 min from 70% Wmax to 85% Wmax; ten 90 s bouts at 90% Wmax, separated by 180 s at 55% Wmax; 90% Wmax until volitional exhaustion. Blood samples were drawn and heart rate was monitored throughout the protocol. There was no significant order effect between trials for time to exhaustion (mean: 4 113.0 ± 60.8 s) or total distance covered (mean: 4 6126.2 ± 1 968.7 m). Total time to exhaustion and total distance covered showed very high reliability with a mean coefficient of variation (CV) of 1.6% (95% Confidence Intervals (CI) 0.0 ± 124.3 s) and CV of 2.2% (95% CI 0.0 ± 1904.9 m), respectively. Variability in plasma glucose concentrations across the time points was very small (CV 0.46-4.3%, mean 95% CI 0.0 ± 0.33 to 0.0 ± 0.94 mmol·L - 1). Plasma lactate concentrations showed no test order effect. The reliability of performance and metabolic variables makes this protocol a valid test to evaluate nutritional interventions in endurance cycling.


Asunto(s)
Rendimiento Atlético/fisiología , Ciclismo/fisiología , Prueba de Esfuerzo/métodos , Resistencia Física/fisiología , Adulto , Atletas , Glucemia/metabolismo , Frecuencia Cardíaca/fisiología , Humanos , Ácido Láctico/sangre , Masculino , Consumo de Oxígeno/fisiología , Reproducibilidad de los Resultados , Factores de Tiempo
4.
Pathophysiol Haemost Thromb ; 32(1): 40-3, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12214162

RESUMEN

Plasminogen activator inhibitor 1 (PAI-1), tissue plasminogen activator (t-PA), fibrinogen and insulin were measured in 43 patients 3 years after they had undergone the Magenstrasse and Mill (MM) procedure and in 43 morbidly obese (MO) patients. Mean plasma PAI-1 was 61 ng/ml in the MO group compared to 30 ng/ml in the MM group (p < 0.0001); mean plasma t-PA was 10 ng/ml in the MO group compared to 7 ng/ml in the MM group (p < 0.001). Mean fibrinogen was 3.6 g/l in the MO group compared to 3.2 g/l in the MM group (p < 0.05). Mean plasma insulin levels were 32 U/ml in the MO group compared to 15 U/ml in the MM group. These changes suggest that use of the MM procedure may reduce mortality and morbidity from coronary heart disease in these high-risk obese patients.


Asunto(s)
Gastroplastia , Obesidad/cirugía , Adulto , Biomarcadores/sangre , Estudios de Casos y Controles , Enfermedad Coronaria/prevención & control , Femenino , Fibrinógeno/análisis , Fibrinólisis , Humanos , Insulina/sangre , Masculino , Persona de Mediana Edad , Obesidad/sangre , Inhibidor 1 de Activador Plasminogénico/sangre , Activador de Tejido Plasminógeno/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...