Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Thorac Cardiovasc Surg ; 166(5): e332-e376, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37500053

RESUMEN

OBJECTIVES: Patients with Loeys-Dietz syndrome demonstrate a heightened risk of distal thoracic aortic events after valve-sparing aortic root replacement. This study assesses the clinical risks and hemodynamic consequences of a prophylactic aortic arch replacement strategy in Loeys-Dietz syndrome and characterizes smooth muscle cell phenotype in Loeys-Dietz syndrome aneurysmal and normal-sized downstream aorta. METHODS: Patients with genetically confirmed Loeys-Dietz syndrome (n = 8) underwent prophylactic aortic arch replacement during valve-sparing aortic root replacement. Four-dimensional flow magnetic resonance imaging studies were performed in 4 patients with Loeys-Dietz syndrome (valve-sparing aortic root replacement + arch) and compared with patients with contemporary Marfan syndrome (valve-sparing aortic root replacement only, n = 5) and control patients (without aortopathy, n = 5). Aortic tissues from 4 patients with Loeys-Dietz syndrome and 2 organ donors were processed for anatomically segmented single-cell RNA sequencing and histologic assessment. RESULTS: Patients with Loeys-Dietz syndrome valve-sparing aortic root replacement + arch had no deaths, major morbidity, or aortic events in a median of 2 years follow-up. Four-dimensional magnetic resonance imaging demonstrated altered flow parameters in patients with postoperative aortopathy relative to controls, but no clear deleterious changes due to arch replacement. Integrated analysis of aortic single-cell RNA sequencing data (>49,000 cells) identified a continuum of abnormal smooth muscle cell phenotypic modulation in Loeys-Dietz syndrome defined by reduced contractility and enriched extracellular matrix synthesis, adhesion receptors, and transforming growth factor-beta signaling. These modulated smooth muscle cells populated the Loeys-Dietz syndrome tunica media with gradually reduced density from the overtly aneurysmal root to the nondilated arch. CONCLUSIONS: Patients with Loeys-Dietz syndrome demonstrated excellent surgical outcomes without overt downstream flow or shear stress disturbances after concomitant valve-sparing aortic root replacement + arch operations. Abnormal smooth muscle cell-mediated aortic remodeling occurs within the normal diameter, clinically at-risk Loeys-Dietz syndrome arch segment. These initial clinical and pathophysiologic findings support concomitant arch replacement in Loeys-Dietz syndrome.


Asunto(s)
Síndrome de Loeys-Dietz , Síndrome de Marfan , Humanos , Síndrome de Loeys-Dietz/complicaciones , Síndrome de Loeys-Dietz/diagnóstico por imagen , Síndrome de Loeys-Dietz/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aorta/cirugía , Síndrome de Marfan/patología , Procedimientos Quirúrgicos Vasculares/métodos
2.
Abdom Radiol (NY) ; 48(2): 642-648, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36370180

RESUMEN

PURPOSE: To assess the performance of a machine learning model trained with contrast-enhanced CT-based radiomics features in distinguishing benign from malignant solid renal masses and to compare model performance with three abdominal radiologists. METHODS: Patients who underwent intra-operative ultrasound during a partial nephrectomy were identified within our institutional database, and those who had pre-operative contrast-enhanced CT examinations were selected. The renal masses were segmented from the CT images and radiomics features were derived from the segmentations. The pathology of each mass was identified; masses were labeled as either benign [oncocytoma or angiomyolipoma (AML)] or malignant [clear cell, papillary, or chromophobe renal cell carcinoma (RCC)] depending on the pathology. The data were parsed into a 70/30 train/test split and a random forest machine learning model was developed to distinguish benign from malignant lesions. Three radiologists assessed the cohort of masses and labeled cases as benign or malignant. RESULTS: 148 masses were identified from the cohort, including 50 benign lesions (23 AMLs, 27 oncocytomas) and 98 malignant lesions (23 clear cell RCC, 44 papillary RCC, and 31 chromophobe RCCs). The machine learning algorithm yielded an overall accuracy of 0.82 for distinguishing benign from malignant lesions, with an area under the receiver operating curve of 0.80. In comparison, the three radiologists had significantly lower accuracies (p = 0.02) ranging from 0.67 to 0.75. CONCLUSION: A machine learning model trained with CT-based radiomics features can provide superior accuracy for distinguishing benign from malignant solid renal masses compared to abdominal radiologists.


Asunto(s)
Adenoma Oxifílico , Carcinoma de Células Renales , Neoplasias Renales , Humanos , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Diagnóstico Diferencial , Estudios Retrospectivos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Aprendizaje Automático , Radiólogos , Adenoma Oxifílico/patología , Tomografía Computarizada por Rayos X , Diferenciación Celular
3.
Eur Radiol ; 32(6): 4225-4233, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34989838

RESUMEN

In this prospective, pilot study, we tested a kV-independent coronary artery calcium scoring CT protocol, using a novel reconstruction kernel (Sa36f). From December 2018 to November 2019, we performed an additional research scan in 61 patients undergoing clinical calcium scanning. For the standard protocol (120 kVp), images were reconstructed with a standard, medium-sharp kernel (Qr36d). For the research protocol (automated kVp selection), images were reconstructed with a novel kernel (Sa36f). Research scans were sequentially performed using a higher (cohort A, n = 31) and a lower (cohort B, n = 30) dose optimizer setting within the automatic system with customizable kV selection. Agatston scores, coronary calcium volumes, and radiation exposure of the standard and research protocol were compared. A phantom study was conducted to determine inter-scan variability. There was excellent correlation for the Agatston score between the two protocols (r = 0.99); however, the standard protocol resulted in slightly higher Agatston scores (29.4 [0-139.0] vs 17.4 [0-158.2], p = 0.028). The median calcium volumes were similar (11.5 [0-109.2] vs 11.2 [0-118.0] mm3; p = 0.176), and the number of calcified lesions was not significantly different (p = 0.092). One patient was reclassified to another risk category. The research protocol could be performed at a lower kV and resulted in a substantially lower radiation exposure, with a median volumetric CT dose index of 4.1 vs 5.2 mGy, respectively (p < 0.001). Our results showed that a consistent coronary calcium scoring can be achieved using a kV-independent protocol that lowers radiation doses compared to the standard protocol. KEY POINTS: • The Sa36f kernel enables kV-independent Agatston scoring without changing the original Agatston weighting threshold. • Agatston scores and calcium volumes of the standard and research protocols showed an excellent correlation. • The research protocol resulted in a significant reduction in radiation exposure with a mean reduction of 22% in DLP and 25% in CTDIvol.


Asunto(s)
Calcio , Enfermedad de la Arteria Coronaria , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Proyectos Piloto , Estudios Prospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos
4.
Radiology ; 300(3): 539-548, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34128724

RESUMEN

Background Obtaining ventricular volumetry and mass is key to most cardiac MRI but challenged by long multibreath-hold acquisitions. Purpose To assess the image quality and performance of a highly accelerated, free-breathing, two-dimensional cine cardiac MRI sequence incorporating deep learning (DL) reconstruction compared with reference standard balanced steady-state free precession (bSSFP). Materials and Methods A DL algorithm was developed to reconstruct custom 12-fold accelerated bSSFP cardiac MRI cine images from coil sensitivity maps using 15 iterations of separable three-dimensional convolutions and data consistency steps. The model was trained, validated, and internally tested in 10, two, and 10 adult human volunteers, respectively, based on vendor partner-supplied fully sampled bSSFP acquisitions. For prospective external clinical validation, consecutive children and young adults undergoing cardiac MRI from September through December 2019 at a single children's hospital underwent both conventional and highly accelerated short-axis bSSFP cine acquisitions in one MRI examination. Two radiologists scored overall and volumetric three-dimensional mesh image quality of all short-axis stacks on a five-point Likert scale and manually segmented endocardial and epicardial contours. Scan times and image quality were compared using the Wilcoxon rank sum test. Measurement agreement was assessed with intraclass correlation coefficient and Bland-Altman analysis. Results Fifty participants (mean age, 16 years ± 4 [standard deviation]; range, 5-30 years; 29 men) were evaluated. The mean prescribed acquisition times of accelerated scans (non-breath-held) and bSSFP (excluding breath-hold time) were 0.9 minute ± 0.3 versus 3.0 minutes ± 1.9 (P < .001). Overall and three-dimensional mesh image quality scores were, respectively, 3.8 ± 0.6 versus 4.3 ± 0.6 (P < .001) and 4.0 ± 1.0 versus 4.4 ± 0.8 (P < .001). Raters had strong agreement between all bSSFP and DL measurements, with intraclass correlation coefficients of 0.76 to 0.97, near-zero mean differences, and narrow limits of agreement. Conclusion With slightly lower image quality yet much faster speed, deep learning reconstruction may allow substantially shorter acquisition times of cardiac MRI compared with conventional balanced steady-state free precession MRI performed for ventricular volumetry. © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Aprendizaje Profundo , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Masculino , Respiración
5.
Cancers (Basel) ; 11(5)2019 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-31052289

RESUMEN

Computed tomography (CT) perfusion is a novel imaging method to determine tumor perfusion using a low-dose CT technique to measure iodine concentration at multiple time points. We determined if early changes in perfusion differ between primary renal tumors and metastatic tumor sites in patients with renal cell carcinoma (RCC) receiving targeted anti-angiogenic therapy. A total of 10 patients with advanced RCC underwent a CT perfusion scan at treatment baseline and at one week after initiating treatment. Perfusion measurements included blood volume (BV), blood flow (BF), and flow extraction product (FEP) in a total of 13 lesions (six primary RCC tumors, seven RCC metastases). Changes between baseline and week 1 were compared between tumor locations: primary kidney tumors vs metastases. Metastatic lesions had a greater decrease in BF (average BF difference ± standard deviation (SD): -75.0 mL/100 mL/min ± 81) compared to primary kidney masses (-25.5 mL/100 mL/min ± 35). Metastatic tumors had a wider variation of change in BF, BV and FEP measures compared to primary renal tumors. Tumor diameters showed little change after one week, but early perfusion changes are evident, especially in metastatic lesions compared to primary lesions. Future studies are needed to determine if these changes can predict which patients are benefiting from targeted therapy.

6.
Int J Cardiovasc Imaging ; 35(8): 1473-1481, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31016501

RESUMEN

The purpose of this study was to assess in pediatric pulmonary artery (PA) reconstruction candidates the feasibility and added utility of preoperative chest computed tomography angiography (CTA) using dual-energy technique, from which perfused blood volume (PBV)/iodine maps can be generated as a surrogate of pulmonary perfusion. Pediatric PA reconstruction patients were prospectively recruited for a new dose-neutral dual-energy CTA protocol. For each case, the severity of anatomic PA obstruction was graded by two pediatric cardiovascular radiologists in consensus using a modified Qanadli index. PBV maps were qualitatively reviewed and auto-segmented using Siemens syngo.via software. Associations between Qanadli scores and PBV were assessed with Spearman correlation (r) and ROC analysis. Effective radiation doses were estimated from dose-length product and ICRP 103 k-factors, using cubic Hermite spline interpolation. 19 patients were recruited with mean (SD) age of 6.0 (5.1), 11 (57.9%) female, 11 (73.7%) anesthetized. Higher QS correlated with lower PBV, both on a whole lung (r = - 0.54, p < 0.001) and lobar (r = - 0.50, p < 0.001) basis. The lung with lowest absolute PBV was predictive of the lung with highest Qanadli score, with AUC of 0.70 (95% CI 0.47-0.93). Qualitatively, PBV maps were heterogeneous, corresponding to multifocal PA stenoses, with decreased iodine content in areas of most severe obstruction. In conclusion, dual-energy chest CTA is feasible for pediatric PA reconstruction candidates. PBV maps show deficits in regions of more severe anatomic obstruction and may serve as a novel biomarker in this population.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada Multidetector/métodos , Procedimientos de Cirugía Plástica , Arteria Pulmonar/diagnóstico por imagen , Estenosis de Arteria Pulmonar/diagnóstico por imagen , Procedimientos Quirúrgicos Vasculares , Adolescente , Factores de Edad , Niño , Preescolar , Toma de Decisiones Clínicas , Estudios de Factibilidad , Femenino , Humanos , Lactante , Masculino , Imagen de Perfusión/métodos , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Arteria Pulmonar/fisiopatología , Arteria Pulmonar/cirugía , Circulación Pulmonar , Interpretación de Imagen Radiográfica Asistida por Computador , Índice de Severidad de la Enfermedad , Estenosis de Arteria Pulmonar/fisiopatología , Estenosis de Arteria Pulmonar/cirugía
7.
Pediatr Radiol ; 49(3): 301-307, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30413857

RESUMEN

BACKGROUND: General anesthesia (GA) or sedation has been used to obtain good-quality motion-free breath-hold chest CT scans in young children; however pulmonary atelectasis is a common and problematic accompaniment that can confound diagnostic utility. Dual-source multidetector CT permits ultrafast high-pitch sub-second examinations, minimizing motion artifact and potentially eliminating the need for a breath-hold. OBJECTIVE: The purpose of this study was to evaluate the feasibility of free-breathing ultrafast pediatric chest CT without GA and to compare it with breath-hold and non-breath-hold CT with GA. MATERIALS AND METHODS: Young (≤3 years old) pediatric outpatients scheduled for chest CT under GA were recruited into the study and scanned using one of three protocols: GA with intubation, lung recruitment and breath-hold; GA without breath-hold; and free-breathing CT without anesthesia. In all three protocols an ultrafast high-pitch CT technique was used. We evaluated CT images for overall image quality, presence of atelectasis and motion artifacts. RESULTS: We included 101 scans in the study. However the GA non-breath-hold technique was discontinued after 15 scans, when it became clear that atelectasis was a major issue despite diligent attempts to mitigate it. This technique was therefore not included in statistical evaluation (86 remaining patients). Overall image quality was higher (P=0.001) and motion artifacts were fewer (P<.001) for scans using the GA with intubation and recruitment technique compared to scans in the non-GA free-breathing group. However no significant differences were observed regarding the presence of atelectasis between these groups. CONCLUSION: We demonstrated that although overall image quality was best and motion artifact least with a GA-breath-hold intubation and recruitment technique, free-breathing ultrafast pediatric chest CT without anesthesia provides sufficient image quality for diagnostic purposes and can be successfully performed both without and with contrast agent in young infants.


Asunto(s)
Atelectasia Pulmonar/diagnóstico por imagen , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Anestesia General , Artefactos , Contencion de la Respiración , Preescolar , Estudios de Factibilidad , Femenino , Humanos , Lactante , Masculino , Estudios Prospectivos , Respiración , Estudios Retrospectivos
8.
J Am Coll Cardiol ; 71(24): 2773-2785, 2018 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-29903350

RESUMEN

BACKGROUND: Limited intimal tears (LITs) of the aorta (Class 3 dissection variant) are the least common form of aortic pathology in patients presenting with acute aortic syndrome (AAS). LITs are difficult to detect on imaging and may be underappreciated. OBJECTIVES: This study sought to describe the frequency, pathology, treatment, and outcome of LITs compared with other AAS, and to demonstrate that LITs can be detected pre-operatively by contemporary imaging. METHODS: The authors retrospectively reviewed 497 patients admitted for 513 AAS events at a single academic aortic center between 2003 and 2012. AAS were classified into classic dissection (AD), intramural hematoma, LIT, penetrating atherosclerotic ulcer, and rupturing thoracic aortic aneurysm. The prevalence, pertinent risk factors, and detailed imaging findings with surgical and pathological correlation of LITs are described. Management, early outcomes, and late mortality are reported. RESULTS: Among 497 patients with AAS, the authors identified 24 LITs (4.8% of AAS) in 16 men and 8 women (17 type A, 7 type B). Patients with LITs were older than those with AD, and type A LITs had similarly dilated ascending aortas as type A AD. Three patients presented with rupture. Eleven patients underwent urgent surgical aortic replacement, and 2 patients underwent endovascular repair. Medial degeneration was present in all surgical specimens. In-hospital mortality was 4% (1 of 24), and in total, 5 patients with LIT died subsequently at 1.5 years (interquartile range [IQR]: 0.3 to 2.5 years). Computed tomography imaging detected all but 1 LIT, best visualized on volume-rendered images. CONCLUSIONS: LITs are rare acute aortic lesions within the dissection spectrum, with similar presentation, complications, and outcomes compared with AD and intramural hematoma. Awareness of this lesion allows pre-operative diagnosis using high-quality computed tomography angiography.


Asunto(s)
Aorta Torácica/lesiones , Enfermedades de la Aorta/mortalidad , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/terapia , California/epidemiología , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
9.
Circ Cardiovasc Imaging ; 10(4)2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28360261

RESUMEN

BACKGROUND: Medical treatment of initially uncomplicated acute Stanford type-B aortic dissection is associated with a high rate of late adverse events. Identification of individuals who potentially benefit from preventive endografting is highly desirable. METHODS AND RESULTS: The association of computed tomography imaging features with late adverse events was retrospectively assessed in 83 patients with acute uncomplicated Stanford type-B aortic dissection, followed over a median of 850 (interquartile range 247-1824) days. Adverse events were defined as fatal or nonfatal aortic rupture, rapid aortic growth (>10 mm/y), aneurysm formation (≥6 cm), organ or limb ischemia, or new uncontrollable hypertension or pain. Five significant predictors were identified using multivariable Cox regression analysis: connective tissue disease (hazard ratio [HR] 2.94, 95% confidence interval [CI]: 1.29-6.72; P=0.01), circumferential extent of false lumen in angular degrees (HR 1.03 per degree, 95% CI: 1.01-1.04, P=0.003), maximum aortic diameter (HR 1.10 per mm, 95% CI: 1.02-1.18, P=0.015), false lumen outflow (HR 0.999 per mL/min, 95% CI: 0.998-1.000; P=0.055), and number of intercostal arteries (HR 0.89 per n, 95% CI: 0.80-0.98; P=0.024). A prediction model was constructed to calculate patient specific risk at 1, 2, and 5 years and to stratify patients into high-, intermediate-, and low-risk groups. The model was internally validated by bootstrapping and showed good discriminatory ability with an optimism-corrected C statistic of 70.1%. CONCLUSIONS: Computed tomography imaging-based morphological features combined into a prediction model may be able to identify patients at high risk for late adverse events after an initially uncomplicated type-B aortic dissection.


Asunto(s)
Aneurisma de la Aorta/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada , Enfermedad Aguda , Adulto , Anciano , Disección Aórtica/complicaciones , Disección Aórtica/mortalidad , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/mortalidad , Rotura de la Aorta/etiología , Progresión de la Enfermedad , Supervivencia sin Enfermedad , Femenino , Humanos , Hipertensión/etiología , Isquemia/etiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Dolor/etiología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
10.
Abdom Radiol (NY) ; 42(4): 1132-1140, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28008455

RESUMEN

PURPOSE: To evaluate the capacity of perfusion CT imaging to distinguish between complete and incomplete responders after neoadjuvant chemoradiation therapy for rectal carcinoma, with particular attention to segmentation technique. MATERIALS AND METHODS: 17 patients were evaluated in this prospective IRB-approved study. For each patient, a perfusion CT acquisition was obtained prior to the initiation of chemoradiation, at 1-2 weeks after the start of chemoradiation, and at 12 weeks after the start of chemoradiation therapy. From each dataset, three perfusion parameters were measured, each in two different ways: a region of interest incorporating only "hot spots" of greatest enhancement and whole-tumor measurements. RESULTS: In univariate analysis, blood volume and permeability differed significantly between responders and non-responders. In logistic regression analysis evaluating predictors of the "complete response" outcome, only two predictors were retained as statistically significant: peak hot spot blood volume 1-2 weeks into therapy (OR 10.25, p = 0.0026) and hot spot permeability decline at 12 weeks after the initiation of therapy (OR 5.62, p = 0.03). The overall likelihood ratio test for this model supported the conclusion that hot spot blood volume and hot spot permeability decline were significant predictors of the complete pathologic response outcome (p < 0.0001). CONCLUSION: In this pilot study, peak tumor blood volume and decline in tumor permeability, when measured in "hot spots" of greatest enhancement, were strong predictors of complete therapeutic response in rectal cancer after neoadjuvant therapy.


Asunto(s)
Quimioradioterapia , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/patología , Neoplasias del Recto/terapia , Tomografía Computarizada por Rayos X/métodos , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Terapia Neoadyuvante , Estudios Prospectivos , Resultado del Tratamiento , Carga Tumoral
11.
J Magn Reson Imaging ; 44(2): 383-92, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26871420

RESUMEN

PURPOSE: To compare the precision and interobserver agreement of ventricular volume, function, and mass quantification by 3D time-resolved (4D) flow MRI relative to cine steady-state free precession (SSFP). MATERIALS AND METHODS: With Institutional Research Board approval, informed consent, and HIPAA compliance, 22 consecutive patients with congenital heart disease (CHD) (10 males, 6.4 ± 4.8 years) referred for 3T ferumoxytol-enhanced cardiac MRI were prospectively recruited. Complete ventricular coverage with standard 2D short-axis cine SSFP and whole chest coverage with axial 4D flow were obtained. Two blinded radiologists independently segmented images for left ventricular (LV) and right ventricular (RV) myocardium at end systole (ES) and end diastole (ED). Statistical analysis included linear regression, analysis of variance (ANOVA), Bland-Altman (BA) analysis, and intraclass correlation (ICC). RESULTS: Significant positive correlations were found between 4D flow and SSFP for ventricular volumes (r = 0.808-0.972, P < 0.001), ejection fraction (EF) (r = 0.900-928, P < 0.001), and mass (r = 0.884-0.934, P < 0.001). BA relative limits of agreement for both ventricles were between -52% to 34% for volumes, -29% to 27% for EF, and -41% to 48% for mass, with wider limits of agreement for the RV compared to the LV. There was no significant difference between techniques with respect to mean square difference of ED-ES mass for either LV (F = 2.05, P = 0.159) or RV (F = 0.625, P = 0.434). Interobserver agreement was moderate to good with both 4D flow (ICC 0.523-0.993) and SSFP (ICC 0.619-0.982), with overlapping confidence intervals. CONCLUSION: Quantification of ventricular volume, function, and mass can be accomplished with 4D flow MRI with precision and interobserver agreement comparable to that of cine SSFP. J. Magn. Reson. Imaging 2016;44:383-392.


Asunto(s)
Óxido Ferrosoférrico , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/patología , Técnicas de Imagen Sincronizada Cardíacas/métodos , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Disfunción Ventricular Izquierda/fisiopatología
12.
Eur J Radiol ; 82(9): 1558-64, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23680155

RESUMEN

OBJECTIVE: To evaluates a semi-automated method for Thoracic Aortic Aneurysm (TAA) measurement using ECG-gated Dual Source CT Angiogram (DSCTA). METHODS: This retrospective HIPAA compliant study was approved by our IRB. Transaxial maximum diameters of outer wall to outer wall were studied in fifty patients at seven anatomic locations of the thoracic aorta: annulus, sinus, sinotubular junction (STJ), mid ascending aorta (MAA) at the level of right pulmonary artery, proximal aortic arch (PROX) immediately proximal to innominate artery, distal aortic arch (DIST) immediately distal to left subclavian artery, and descending aorta (DESC) at the level of diaphragm. Measurements were performed using a manual method and semi-automated software. All readers repeated their measurements. Inter-method, intra-observer and inter-observer agreements were evaluated according to intraclass correlation coefficient (ICC) and Bland-Altman plot. The number of cases with manual contouring or center line adjustment for the semi-automated method and also the post-processing time for each method were recorded. RESULTS: The mean difference between semi-automated and manual methods was less than 1.3mm at all seven points. Strong inter-method, inter-observer and intra-observer agreement was recorded at all levels (ICC ≥ 0.9). The maximum rate of manual adjustment of center line and contour was at the level of annulus. The average time for manual post-processing of the aorta was 19 ± 0.3 min, while it took 8.26 ± 2.1 min to do the measurements with the semi-automated tool (Vitrea version 6.0.0.1 software). The center line was edited manually at all levels, with most corrections at the level of annulus (60%), while the contour was adjusted at all levels with highest and lowest number of corrections at the levels of annulus and DESC (75% and 0.07% of the cases), respectively. CONCLUSION: Compared to the commonly used manual method, semi-automated measurement of vessel dimensions is feasible in the thoracic aorta with the advantage of reduced post-processing time.


Asunto(s)
Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Aorta Torácica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
13.
Int J Cardiovasc Imaging ; 29(1): 191-7, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22527259

RESUMEN

Contrast enhanced magnetic resonance imaging (CeMRI) reliably identifies myocardial fibrosis in patients with hypertrophic cardiomyopathy (HCM). However, many patients have contraindications to ceMRI. Previous studies have shown that contrast enhanced multi-detector computed tomography (ceMDCT) can visualize focal scars following myocardial infarction in experimental animals and patients. The purpose of this manuscript is to assess the ability of ceMDCT to detect focal myocardial scars in patients with HCM. Twelve HCM patients underwent ceMRI and ceMDCT. Fibrotic areas of myocardium were defined as focal or diffuse areas of fibrosis. The mean signal intensity in ceMRI and attenuation values in ceMDCT of the fibrotic regions, normal myocardium and left ventricle blood pool contrast were measured using qualitative and quantitative analysis. Focal scar mass was calculated using both techniques. Focal scars were detected in 9 patients and diffuse fibrosis was visualized in all patients by ceMRI. Differences between normalized SI of normal myocardium and focal scars, normal and diffuse areas of fibrosis, and diffuse fibrosis and focal scars were significant for both ceMRI and ceMDCT (p < 0.05). Diffuse fibrosis was poorly visualized by ceMDCT but was detectable using quantitative measurements. CeMDCT has potential to detect focal myocardial scars in patients with HCM who have contraindications to ceMRI study. However, ceMDCT does not enable adequate visualization of diffuse myocardial fibrosis, and thus is less well suited than ceMRI for assessment of total burden of fibrosis. This limitation may be overcome using quantitative methodology.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico , Cicatriz/diagnóstico , Imagen por Resonancia Magnética , Tomografía Computarizada Multidetector , Miocardio/patología , Adulto , Análisis de Varianza , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/patología , Cicatriz/diagnóstico por imagen , Cicatriz/patología , Medios de Contraste , Femenino , Fibrosis , Gadolinio DTPA , Humanos , Yohexol , Modelos Lineales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Adulto Joven
14.
Circ Res ; 111(10): 1286-96, 2012 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-22914647

RESUMEN

RATIONALE: Various types of viable stem cells have been reported to result in modest improvement in cardiac function after acute myocardial infarction. The mechanisms for improvement from different stem cell populations remain unknown. OBJECTIVE: To determine whether irradiated (nonviable) embryonic stem cells (iESCs) improve postischemic cardiac function without adverse consequences. METHODS AND RESULTS: After coronary artery ligation-induced cardiac infarction, either conditioned media or male murine or male human iESCs were injected into the penumbra of ischemic myocardial tissue of female mice or female rhesus macaque monkeys, respectively. Murine and human iESCs, despite irradiation doses that prevented proliferation and induced cell death, significantly improved cardiac function and decreased infarct size compared with untreated or media-treated controls. Fluorescent in situ hybridization of the Y chromosome revealed disappearance of iESCs within the myocardium, whereas 5-bromo-2'-deoxyuridine assays revealed de novo in vivo cardiomyocyte DNA synthesis. Microarray gene expression profiling demonstrated an early increase in metabolism, DNA proliferation, and chromatin remodeling pathways, and a decrease in fibrosis and inflammatory gene expression compared with media-treated controls. CONCLUSIONS: As a result of irradiation before injection, ex vivo and in vivo iESC existence is transient, yet iESCs provide a significant improvement in cardiac function after acute myocardial infarction. The mechanism(s) of action of iESCs seems to be related to cell-cell exchange, paracrine factors, and a scaffolding effect between iESCs and neighboring host cardiomyocytes.


Asunto(s)
Células Madre Embrionarias/citología , Infarto del Miocardio/patología , Infarto del Miocardio/terapia , Miocardio/patología , Miocitos Cardíacos/citología , Trasplante de Células Madre/métodos , Animales , Presión Sanguínea/fisiología , Técnicas de Cultivo de Célula/métodos , Proliferación Celular , Células Cultivadas , Técnicas de Cocultivo , Células Madre Embrionarias/fisiología , Células Madre Embrionarias/efectos de la radiación , Femenino , Fibroblastos/citología , Fibroblastos/fisiología , Supervivencia de Injerto/fisiología , Humanos , Macaca mulatta , Ratones , Ratones Endogámicos ICR , Ratones Endogámicos NOD , Ratones SCID , Contracción Miocárdica/fisiología , Infarto del Miocardio/fisiopatología , Miocitos Cardíacos/fisiología , Transcriptoma , Trasplante Heterólogo
15.
Int J Cardiovasc Imaging ; 27(4): 527-37, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20499279

RESUMEN

The purpose of this study was to compare a navigator gated free breathing 3D Phase Sensitive Inversion Recovery (PSIR) TurboFLASH to an established 2D PSIR TurboFLASH method for detecting myocardial late gadolinium hyperenhanced lesions caused by infiltrative and non-ischemic cardiomyopathy. Under an IRB approved protocol; patients with suspected non-ischemic infiltrative myocardial heart disease were examined on a 1.5T MR scanner for late enhancement after the administration of gadolinium using a segmented 2D PSIR TurboFLASH sequence followed by a navigator-gated 3D PSIR TurboFLASH sequence. Two independent readers analyzed image quality using a four point Likert scale for qualitative analysis (0 = poor, non diagnostic; 1 = fair, diagnostic may be impaired; 2 = good, some artifacts but not interfering in diagnostics, 3 = excellent, no artifacts) and also reported presence or absence of scar. Detected scars were classified based on area and location and also compared quantitatively in volume. Twenty-seven patients were scanned using both protocols. Image quality score did not differ significantly (p = 0.358, Wilcoxon signed rank test) for both technique. Scars were detected in 24 patients. Larger numbers of hyperenhanced scars were detected with 3D PSIR (200) compared to 2D PSIR (167) and scar volume were significant larger in 3D PSIR (p = 0.004). The mean scar volume over all cases was 49.95 cm(3) for 2D PSIR and 70.02 cm(3) for 3D PSIR. The navigator gated free breathing 3D PSIR approach is a suitable method for detecting myocardial late gadolinium hyperenhanced lesions caused by non-ischemic cardiomyopathy due to its complete isotropic coverage of the left ventricle, improving detection of scar lesions compared to 2D PSIR imaging.


Asunto(s)
Cardiomiopatías/diagnóstico , Cicatriz/diagnóstico , Ventrículos Cardíacos/patología , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Artefactos , Cardiomiopatías/patología , Chicago , Cicatriz/patología , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
16.
J Comput Assist Tomogr ; 34(5): 684-8, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20861770

RESUMEN

PURPOSE: First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. METHODS: In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. RESULTS: Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). CONCLUSIONS: Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.


Asunto(s)
Estenosis Coronaria/diagnóstico , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Animales , Medios de Contraste , Modelos Animales de Enfermedad , Perros , Estudios de Factibilidad , Gadolinio DTPA , Procesamiento de Imagen Asistido por Computador
17.
Magn Reson Med ; 64(4): 1148-54, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20564588

RESUMEN

First-pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate-gradient (CG) highly constrained back-projection reconstruction (HYPR) (SW-CG-HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath-hold. This work presents a non-model-based motion correction method combined with SW-CG-HYPR to perform free-breathing myocardial MR imaging. Simulation studies were first performed to show the effectiveness of the proposed motion correction method and its independence from the pattern of the respiratory motion. After that, in vivo studies were performed in six healthy volunteers. From all of the volunteer studies, the image quality score of free breathing perfusion images with motion correction (3.11 ± 0.34) is improved compared with that of images without motion correction (2.27 ± 0.32), and is comparable with that of successful breath-hold images (3.12 ± 0.38). This result was further validated by a quantitative sharpness analysis. The left ventricle and myocardium signal changes in motion corrected free-breathing perfusion images were closely correlated to those observed in breath-hold images. The correlation coefficient is 0.9764 for myocardial signals. Bland-Altman analysis confirmed the agreement between the free-breathing SW-CG-HYPR method with motion correction and the breath-hold SW-CG-HYPR. This technique may allow myocardial perfusion MRI during free breathing.


Asunto(s)
Artefactos , Circulación Coronaria/fisiología , Corazón/fisiología , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Algoritmos , Velocidad del Flujo Sanguíneo/fisiología , Corazón/anatomía & histología , Humanos , Movimiento , Reproducibilidad de los Resultados , Mecánica Respiratoria , Sensibilidad y Especificidad
18.
Radiology ; 254(1): 98-108, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20019138

RESUMEN

PURPOSE: To compare accelerated real-time two-dimensional (2D) and segmented three-dimensional (3D) cine steady-state free precession magnetic resonance (MR) imaging techniques by using a 32-channel coil with a conventional 2D cine imaging approach for imaging the heart and to evaluate any difference caused by free breathing and breath holding for real-time imaging. MATERIALS AND METHODS: In this institutional review board-approved HIPAA-compliant study, 10 healthy volunteers and 22 consecutive patients who were suspected of having or were known to have heart disease underwent cardiac MR imaging by using a 32-channel coil. A conventional multisection 2D real-time cine sequence was used as the reference standard, and three additional accelerated cine sequences were implemented. Volumetric parameters, including ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume(SV), and myocardial mass, were derived. Wall motion and image quality were assessed by two radiologists. In addition, image time was registered. An additional set of images was acquired by using real-time sequences with free breathing, and quantitative measurements were compared with measurements on images obtained with breath holding. For quantitative analysis, repeated-measures analysis of variance, paired t test, and Bland-Altman analysis were used; for qualitative analysis, nonparametric Wilcoxon signed-rank test was used. RESULTS: All volumetric measurements were significantly correlated with those of the standard sequence (r > 0.80, P < .01). No significant difference among protocols was observed in terms of mean levels for EF or ESV (P > .05). However, a significant difference was indicated for EDV and SV (P < .01).The accelerated protocols had significantly shorter image times (P < .001). Wall motion scores were concordant with the standard sequence in 43-44 (93%-96%) segments for the accelerated protocols, with a strong interreader agreement (intraclass correlation coefficient, > or =0.93). No significant difference was identified between real-time protocols with free breathing and those with breath holding for measurement of volumetric parameters. CONCLUSION: Accelerated real-time 2D and segmented 3D cine techniques are comparable to the standard clinical protocol in assessment of left ventricular global and regional parameters in substantially shorter image times.


Asunto(s)
Cardiopatías/diagnóstico , Aumento de la Imagen/instrumentación , Imagen por Resonancia Cinemagnética/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Estudios de Casos y Controles , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/instrumentación , Masculino , Persona de Mediana Edad , Estadísticas no Paramétricas
19.
AJR Am J Roentgenol ; 193(5): W381-8, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19843715

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate a new free-breathing 3D phase-sensitive inversion-recovery (PSIR) turbo FLASH pulse sequence for the detection of left ventricular myocardial scar. SUBJECTS AND METHODS: Patients with suspected myocardial scar were examined on a 1.5-T MR scanner for myocardial late enhancement after the administration of gadopentetate dimeglumine using a segmented 2D PSIR turbo FLASH sequence followed by a navigator-gated 3D PSIR turbo FLASH sequence. Image quality was scored by two independent readers using a 4-point Likert scale (0 = poor, nondiagnostic; 1 = fair, diagnostics may be impaired; 2 = good, some artifacts but not interfering in diagnostics; 3 = excellent, no artifacts). Scars were compared quantitatively in volume and graded qualitatively on the basis of size (area) and location. RESULTS: Thirty-three patients were scanned using both techniques. In 25 patients, the quality of the 3D PSIR images was acceptable. Scars were detected in 12 patients. Hyperenhanced scar volumes (p = 0.43), qualitative analysis of scar area (p = 0.78), and scar location (p = 0.68) were similar for both techniques. More small hyperenhanced scars, corresponding mostly to nonischemic distribution patterns, were detected using 3D PSIR than 2D PSIR. Although 2D and 3D results were found to be highly correlated for scar volume, Bland-Altman analysis indicated a systematic smaller infarct volume on the 2D PSIR scans (R(2) = 0.84). CONCLUSION: Free-breathing 3D PSIR turbo FLASH imaging is a promising technique for the assessment of left ventricular scar particularly for scar quantification and the detection of small nonischemic scars in the myocardium.


Asunto(s)
Cicatriz/patología , Ventrículos Cardíacos/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Adolescente , Adulto , Anciano , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Lineales , Masculino , Persona de Mediana Edad , Infarto del Miocardio/patología , Estudios Prospectivos
20.
Magn Reson Med ; 62(4): 835-9, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19672941

RESUMEN

First-pass perfusion MRI is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. In this study we investigated the feasibility of using a method that combines sliding window and CG-HYPR methods (SW-CG-HYPR) to reduce the acquisition window for each slice while maintaining the temporal resolution of one frame per heartbeat in myocardial perfusion MRI. This method allows an increased number of slices, reduced motion artifacts, and preserves the relatively high SNR and spatial resolution of the "composite images." Results from eight volunteers demonstrate the feasibility of SW-CG-HYPR for accelerated myocardial perfusion imaging with accurate signal intensity changes of left ventricle blood pool and myocardium. Using this method the acquisition time per cardiac cycle was reduced by a factor of 4 and the number of slices was increased from 3 to 8 as compared to the conventional technique. The SNR of the myocardium at peak enhancement with SW-CG-HYPR (13.83 +/- 2.60) was significantly higher (P < 0.05) than the conventional turbo-FLASH protocol (8.40 +/- 1.62). Also, the spatial resolution of the myocardial perfection images was significantly improved. SW-CG-HYPR is a promising technique for myocardial perfusion MRI.


Asunto(s)
Algoritmos , Ventrículos Cardíacos/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...