Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Quintessence Int ; 54(4): 266-273, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-36477726

RESUMEN

OBJECTIVE: This in vitro study aimed to compare the diagnostic outcomes of caries detection in premolar and molar teeth on digital periapical radiographs viewed as grayscale images and in the Java-based software (JBS) pseudocolor spectrum. METHOD AND MATERIALS: The study comprised 92 premolar or molar human teeth (n = 46 with caries and n = 46 without clinical caries). For each tooth, digital periapical radiographic images (DPRIs), JBS pseudocolor images, and stereomicroscope images were collected, and caries presence and depth were recorded. In JBS pseudocolor images, regions of interest (ROIs) were detected, and ROI values for caries area (ROI1), non-caries area (ROI2), mesial area (ROI3), and distal area (ROI4) were obtained. The degree of inter-observer agreement was determined using the kappa coefficient, and the sensitivity and specificity of the methods were assessed using ROC analysis. RESULTS: While neither method was consistent with stereomicroscopy in determining caries depth (P < .005), for both observers the kappa value of JBS pseudocolor images were slightly higher than those for DPRIs. ROI1 was found to be significantly lower than ROI2 (P < .001), whereas no difference was found between ROI3 and ROI4 (P = .877). For both observers, the sensitivity and specificity obtained from JBS pseudocolor were above 89%. CONCLUSION: JBS pseudocolor images can be used for caries detection and offer high sensitivity and specificity.


Asunto(s)
Caries Dental , Humanos , Caries Dental/diagnóstico por imagen , Variaciones Dependientes del Observador , Radiografía Dental Digital , Sensibilidad y Especificidad , Programas Informáticos
2.
Eur Endod J ; 2021 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-33531449

RESUMEN

OBJECTIVE: The present study aimed to compare the effect of sodium hypochlorite (NaOCl) gel and solution forms on postoperative pain level. METHODS: Fifty-two patients were divided into two groups according to the root canal irrigation solution. In the NaOCl solution group, the root canals were irrigated with 2 mL of 5.25% NaOCl between each pecking motion. In the NaOCl gel group, 5.25% NaOCl gel was used according to the manufacturer's instructions. The root canal treatments were completed and the participants were given instructions to record postoperative pain levels on 24, 48, and 72 hours and 1 week after treatment using VAS. RESULTS: Intergroup analyses revealed that the NaOCl gel group resulted in significantly less postoperative pain than the NaOCl solution group on day 1. CONCLUSION: It can be concluded that using NaOCl gel during root canal preparation results in less postoperative on day 1 when compared with the NaOCl solution.

3.
Artículo en Inglés | MEDLINE | ID: mdl-33408825

RESUMEN

Background. This study purposed to compare the effect of new single glide path files on extruded apical debris and total preparation times during root canal preparation with the WaveOne Gold system. Methods. Thirty-six extracted human lower molar teeth with mesiobuccal canal curvature angles of 25‒35° were randomly splited to three groups. In group 1, the glide path was created with WaveOne Gold Glider (WGG) file at working length (WL); in group 2, the glide path was created with ProGlider file (PG); in group 3, the glide path was not performed. In all the groups, the root canals were shaped with WaveOne Gold Primary (WOG) reciprocating files at WL. Apically extruded debris during instrumentation was picked up into pre-weighed Eppendorf tubes. The weight of the dry extruded debris was calculated by subtracting the pre- and post-instrumentation weights of the tubes in each group. The total time elapsed during the canal preparation was calculated with a chronometer. The data were analyzed using one-way ANOVA and post hoc Tukey tests. Results. The WGG/WOG group extruded significantly fewer debris than the WOG and PG/WOG groups (P<0.05). There was no significant difference between the WOG and PG/WOG groups (P>0.05). The WGG/WOG and PG/WOG groups were significantly faster than the WOG group. Conclusion. The amount of debris extruded apically significantly diminished when conventional WGG was implemented before using WOG. The total preparation time significantly diminished when the WOG file was used in combination with reciprocating and rotary glide path preparation techniques.

4.
J Endod ; 46(2): 238-243, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31883621

RESUMEN

INTRODUCTION: The purpose of the present study was to evaluate the remaining root canal filling material, apical transportation, and crack formation after retreatment with M-Wire Reciproc (VDW GmbH, Munich, Germany) and Reciproc Blue (VDW GmbH) systems in curved root canals. METHODS: Twenty-six mandibular first and second molars with mesial roots that had 2 separate canals with angles between 20° and 40° were selected for this study. The root canals were prepared with M-Wire Reciproc size 25 instruments (VDW GmbH), and they were filled with gutta-percha and AH Plus sealer (Dentsply Sirona, Tulsa, OK). The samples were randomly divided into 2 groups (n = 13 each) according to the retreatment system used: an M-Wire Reciproc group and a Reciproc Blue group. The canals were retreated up to instrument size 25 and then to size 40 in both groups. After the retreatment procedures, the residual filling material volume, apical transportation, and crack formation were assessed using micro-computed tomographic imaging. RESULTS: There were no significant differences between the groups in the amount of residual filling material (P > .05). The apical canal transportation values were significantly higher in the M-Wire Reciproc group than in the Reciproc Blue group at 1 mm. No significant differences were observed between the groups at any of the other levels with regard to apical transportation (P > .05) The new uncompleted and completed cracks were observed in both groups. There were no statistically significant differences between the groups in terms of crack and fracture formation (P > .05). CONCLUSIONS: The Reciproc Blue system is as effective as the M-Wire Reciproc system in terms of the retreatment of the curved mesial roots of mandibular molars. However, the formation of new uncompleted and completed cracks was found during the retreatment procedures.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Preparación del Conducto Radicular , Cavidad Pulpar , Diseño de Equipo , Gutapercha , Humanos , Retratamiento , Microtomografía por Rayos X
5.
Restor Dent Endod ; 44(4): e36, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31799164

RESUMEN

OBJECTIVES: The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial double-curvature canals. MATERIALS AND METHODS: This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test. RESULTS: The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05). CONCLUSIONS: In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.

6.
Artículo en Inglés | MEDLINE | ID: mdl-31217920

RESUMEN

Background . The aim of the present study was to compare the cyclic fatigue resistance of novel nickel titanium rotary pathfinding instruments. Methods . Twenty instruments were selected for each file system. A simulated stainless steel root canal, with a 90° angle of curvature and a curvature radius of 3 mm, was used for cyclic fatigue test of the ProGlider (#16, progressive taper: 0.02‒ 0.085), PathGlider (#15, taper: .03), and One G (#14, taper: .03) instruments. Statistical analyses were performed with oneway ANOVA (P=0.05). Post hoc Tukey tests were used to determine any statistically significant differences between the groups. Results . The ProGlider instruments exhibited significantly more cyclic fatigue resistance than both PathGlider and One G instruments (P<0.001). One G instruments had significantly more resistance to fracture than PathGlider instruments (P<0.05). Conclusion . ProGlider instruments had better cyclic fatigue resistance than PathGlider and One G instruments.

7.
Int J Artif Organs ; 39(12): 625-628, 2017 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-28194749

RESUMEN

PURPOSE: The aim of this study was to investigate the apical transportation of the ProGlider and ProTaper Next using 3 different motions (150° clockwise [CW]; 0° counter clockwise [CCW], 270° CW-30° CCW; and [360° CW] continuous rotation). MATERIALS AND METHODS: 36 simulated, curved, plastic training blocks were randomly distributed into 3 groups for treatment according to the movement kinematics used for ProGlider (Dentsply Maillefer) followed by ProTaper Next (Dentsply Maillefer) instruments (n = 12): 150° CW-30° CCW, 270° CW-30° CCW, and 360° CW (continuous rotation). Pre- and post-instrumentation photographs were taken from the root canals in a standardized manner. Root canal transportation was calculated at 1, 2, 3, 4, and 5 mm from the apical terminus of the canal. Data were analyzed using a Kruskal-Walis H test (p = .05). RESULTS: At the 1- and 2-mm levels, both reciprocating motions (150° CW-30° CCW and 270° CW-30° CCW) resulted in less transportation than those of continuous rotation (p<.05). However, there were no significant differences between the groups at the 3-, 4-, and 5-mm levels (p>.05). CONCLUSIONS: Both reciprocating motions were found to have less canal transportation than the continuous rotation group at the 1- and 2-mm levels. This is the first study about the use of the ProGlider and ProTaper Next activated by different motions. Reciprocating motion can be beneficial for ProGlider and ProTaper Next to reduce transportation of root canals.

8.
Int J Artif Organs ; 38(3): 161-4, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25867700

RESUMEN

PURPOSE: To compare the effect of the TF Adaptive, ProTaper Next, OneShape, WaveOne, Reciproc, (SAF) on the reduction of E. faecalis in experimentally infected root canals. MATERIALS AND METHODS: 70 human mandibular incisor teeth with straight roots and single root canals were selected for this experiment and the root canals of the selected teeth were infected with E. faecalis. After contamination, all the root canals were randomly divided into 7 groups: control, ProTaper Next, TF Adaptive, SAF, WaveOne, Reciproc, and OneShape. After the irrigation procedures, samples were taken from root canals with paper points and incubated in blood agar plates. The colonies grown on the blood agar were counted and interpreted as colony forming units per milliliter. RESULTS: Analysis of results showed that all instrumentation systems were more effective in reducing the number of bacteria than the control (P<.001). The ProTaper Next, TF Adaptive, WaveOne, Reciproc, and OneShape systems were significantly more effective than the SAF system in reducing E. faecalis within the root canals (P<.001). CONCLUSIONS: All instrumentation systems used in this study provided a significant reduction in bacterial populations.


Asunto(s)
Instrumentos Dentales , Cavidad Pulpar/microbiología , Desinfección/instrumentación , Enterococcus faecalis , Humanos , Técnicas In Vitro , Distribución Aleatoria
9.
J Endod ; 41(7): 1130-3, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25843752

RESUMEN

INTRODUCTION: The purpose of the present study was to assess the effect of root canal instrumentation using Twisted File Adaptive instruments (Axis/SybronEndo, Orange, CA) with different kinematics (adaptive motion, 90° clockwise [CW]-30° counterclockwise [CCW], 150° CW-30° CCW, 210° CW-30° CCW, and continuous rotation) on crack formation. METHODS: One hundred five mandibular central incisor teeth were selected. Fifteen teeth were left unprepared (control group), and the remaining 90 teeth were assigned to the 5 root canal shaping groups as follows (n = 15): adaptive motion, 90° CW-30° CCW, 150° CW-30° CCW, 210° CW-30° CCW, continuous rotation, and hand file. All the roots were sectioned horizontally at 3, 6, and 9 mm from the apex with a low-speed saw under water cooling, and the slices were then viewed through a stereomicroscope at 25× magnification. Digital images of each slice were captured using a camera to determine the presence of dentinal cracks. RESULTS: No cracks were observed in the control group, and the continuous rotation group had more cracks than the reciprocation groups (90° CW-30° CCW, 150° CW-30° CCW, and 210° CW-30° CCW) (P < .05). Both the continuous rotation and adaptive motion groups had significantly more dentinal cracks than the hand file group (P < .05). Regarding the different sections (3, 6, and 9 mm), there was a significant difference between the experimental groups at the 9-mm level (P < .05). CONCLUSIONS: The incidence of dentinal cracks is less with TF Adaptive instruments working in 210° CW-30° CCW reciprocating motion compared with working in continuous rotation and adaptive motion.


Asunto(s)
Dentina/lesiones , Preparación del Conducto Radicular/instrumentación , Falla de Equipo , Humanos , Incisivo/lesiones , Movimiento (Física) , Rotación
10.
J Endod ; 41(2): 261-4, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25476974

RESUMEN

INTRODUCTION: The aim of this study was to compare the incidence of root cracks after root canal instrumentation with the TF Adaptive, WaveOne, ProTaper Next, and ProTaper Universal systems. METHODS: Seventy-five extracted mandibular central incisors with mature apices and straight root canals (<5°) were selected and kept in distilled water. The root canals were instrumented by using the ProTaper Universal, ProTaper Next, WaveOne, and TF Adaptive systems. All the roots were horizontally sectioned 3, 6, and 9 mm from the apex with a low-speed saw under water cooling. The slices were then viewed through a stereomicroscope at ×25 magnification. The samples were photographed with a camera to determine the presence of dentinal cracks. RESULTS: The control group had no cracks, and the difference between the control group and the experimental groups was statistically significant (P < .001). The ProTaper Next and TF Adaptive systems produced significantly less cracks than the ProTaper Universal and WaveOne systems in the apical section (3 mm) (P < .05). CONCLUSIONS: Under the study conditions and within the limitations of this study, it can be concluded that the ProTaper Universal, ProTaper Next, WaveOne, and TF Adaptive instruments can result in dentinal cracks.


Asunto(s)
Dentina/fisiopatología , Incisivo/fisiopatología , Preparación del Conducto Radicular/efectos adversos , Fracturas de los Dientes/fisiopatología , Raíz del Diente/fisiopatología , Instrumentos Dentales/efectos adversos , Cavidad Pulpar/fisiopatología , Dentina/cirugía , Humanos , Incisivo/cirugía , Preparación del Conducto Radicular/instrumentación , Ápice del Diente/fisiopatología , Ápice del Diente/cirugía , Fracturas de los Dientes/etiología , Raíz del Diente/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...