1.
J Interv Cardiol ; 31(2): 170-176, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29166699

RESUMEN

BACKGROUNDS: New-generation bioresorbable polymer-everolimus eluting stents (BP-EES) are available. This study aimed to compare the clinical outcomes for BP-EES compared to more established stent designs, namely the platinum chromium-EES (PtCr-EES) and cobalt chrome-EES(CoCr-EES) in patients with the end-stage chronic kidney disease (CKD) including hemodialysis (HD). METHODS: One-hundred-forty-one consecutive stents (BP-EES [n = 44], PtCr-EES [n = 45], and CoCr-EES [n = 52]) were implanted in 104 patients with CKD. All patients underwent a follow-up coronary angiography at 12 months after implantation. End-stage CKD was defined as an estimated glomerular filtration rate (eGFR) <30 mL/min/1.73 m2 , or the need for HD. The following outcome variables were compared among the three stent groups after implantation and the 12-month follow-up: target lesion revascularization (TLR), stent thrombosis (ST), and major adverse cardiac event (MACE). Minimal stent diameter (MSD) and %diameter-stenosis (%DS) were measured using quantitative coronary angiography. RESULTS: The overall rate of TLR and MACE was 14.6% and 30.8%, respectively, with no incidence of ST. Immediately after implantation, the MSD (P = 0.22) and %DS (P = 0.42) were equivalent among the three groups. However, at the 12-month follow-up, a tendency towards higher TLR was observed for the BP-EES group (22.7%) compared with the PtCr-EES (8.8%) and CoCr-EES (9.6%) groups (P = 0.07). Late loss in lumen diameter was also significantly greater for the BP-EES (0.51 ± 0.64 mm) group than either the PtCr-EES (0.20 ± 0.61 mm) and CoCr-EES (0.25 ± 0.70 mm) groups (P = 0.03). CONCLUSIONS: BP-EES might increase the risk of in-stent restenosis in patients with end-stage of CKD or the need for HD.


Asunto(s)
Cromo/uso terapéutico , Cobalto/uso terapéutico , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Vasos Coronarios , Everolimus/uso terapéutico , Fallo Renal Crónico , Intervención Coronaria Percutánea/efectos adversos , Platino (Metal)/uso terapéutico , Implantes Absorbibles/normas , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/epidemiología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos/normas , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/uso terapéutico , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Diálisis Renal/métodos , Factores de Riesgo , Oligoelementos/uso terapéutico , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA