2.
Anesth Analg ; 115(6): 1315-23, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23144441

RESUMEN

BACKGROUND: Bacterial contamination of intravascular devices has been associated with increased morbidity and mortality in various hospital settings, including the perioperative environment. Catheter hub disinfection has been shown in an ex vivo model to attenuate intraoperative injection of bacterial organisms originating from the anesthesia provider's hands, providing the impetus for improvement in intraoperative disinfection techniques and compliance. In the current study, we investigated the clinical effectiveness of a new, passive catheter care station in reducing the incidence of bacterial contamination of open lumen patient IV stopcock sets. The secondary aim was to evaluate the impact of this novel intervention on the combined incidence of 30-day postoperative infections and IV catheter-associated phlebitis. METHODS: Five hundred ninety-four operating room environments were randomized by a computer-generated list to receive either a novel catheter care bundle (HubScrub and DOCit) or standard caps in conjunction with a sterile, conventional open lumen 3-way stopcock set (24 inch with 3-gang 4-way and T-Connector). Patients underwent general anesthesia according to usual practice and were followed prospectively for 30 postoperative days to identify the development of health care-associated infections (HCAIs) and/or phlebitis. The primary outcome was intraoperative bacterial contamination of the primary stopcock set used by the anesthesia provider(s). The secondary outcome was the combined incidence of 30-day postoperative infections and phlebitis. RESULTS: Five hundred seventy-two operating rooms were included in the final analysis. Study groups were comparable with no significant differences in patient, provider, anesthetic, or procedural characteristics. The catheter care station reduced the incidence of primary stopcock lumen contamination compared with standard caps (odds ratio [OR] 0.79, 95% confidence interval [CI] 0.63-0.98, P = 0.034) and was associated with a reduction in the combined incidence of HCAIs and IV catheter-associated phlebitis with and without adjustment for patient and procedural covariates (OR(adjusted) 0.589, 95% CI 0.353-0.984, P = 0.040). The risk-adjusted number needed to treat to eliminate 1 case of lumen contamination was 9 (95% CI 3.4-13.5) patients, whereas the risk-adjusted number needed to treat to eliminate 1 case of HCAI/catheter-associated phlebitis was 17 (95% CI 11.8-17.9) patients. CONCLUSION: Intraoperative use of a passive catheter care station significantly reduced open lumen bacterial contamination and the combined incidence of 30-day postoperative infections and phlebitis.


Asunto(s)
Infecciones Bacterianas/prevención & control , Infecciones Relacionadas con Catéteres/prevención & control , Control de Infecciones/métodos , Inyecciones Intravenosas/efectos adversos , Inyecciones Intravenosas/instrumentación , Cuidados Intraoperatorios/métodos , Adulto , Anciano , Anestesia General , Anestesia Intravenosa , Infecciones Bacterianas/epidemiología , Infecciones Bacterianas/microbiología , Infecciones Relacionadas con Catéteres/epidemiología , Infección Hospitalaria/epidemiología , Demografía , Desinfección/métodos , Método Doble Ciego , Contaminación de Equipos , Femenino , Humanos , Inyecciones Intravenosas/métodos , Masculino , Persona de Mediana Edad , Quirófanos/organización & administración , Flebitis/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Infección de la Herida Quirúrgica/prevención & control , Centros Traumatológicos , Resultado del Tratamiento
3.
Anesth Analg ; 115(5): 1109-19, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23051883

RESUMEN

BACKGROUND: Device-related bloodstream infections are associated with a significant increase in patient morbidity and mortality in multiple health care settings. Recently, intraoperative bacterial contamination of conventional open-lumen 3-way stopcock sets has been shown to be associated with increased patient mortality. Intraoperative use of disinfectable, needleless closed catheter devices (DNCCs) may reduce the risk of bacterial injection as compared to conventional open-lumen devices due to an intrinsic barrier to bacterial entry associated with valve design and/or the capacity for surface disinfection. However, the relative benefit of DNCC valve design (intrinsic barrier capacity) as compared to surface disinfection in attenuation of bacterial injection in the clinical environment is untested and entirely unknown. The primary aim of the current study was to investigate the relative efficacy of a novel disinfectable stopcock, the Ultraport zero, with and without disinfection in attenuating intraoperative injection of potential bacterial pathogens as compared to a conventional open-lumen stopcock intravascular device. The secondary aims were to identify risk factors for bacterial injection and to estimate the quantity of bacterial organisms injected during catheter handling. METHODS: Four hundred sixty-eight operating room environments were randomized by a computer generated list to 1 of 3 device-injection schemes: (1) injection of the Ultraport zero stopcock with hub disinfection before injection, (2) injection of the Ultraport zero stopcock without prior hub disinfection, and (3) injection of the conventional open-lumen stopcock closed with sterile caps according to usual practice. After induction of general anesthesia, the primary anesthesia provider caring for patients in each operating room environment was asked to perform a series of 5 injections of sterile saline through the assigned device into an ex vivo catheter system. The primary outcome was the incidence of bacterial contamination of the injected fluid column (effluent). Risk factors for effluent contamination were identified in univariate analysis, and a controlled laboratory experiment was used to generate an estimate of the bacterial load injected for contaminated effluent samples. RESULTS: The incidence of effluent bacterial contamination was 0% (0/152) for the Ultraport zero stopcock with hub disinfection before injection, 4% (7/162) for the Ultraport zero stopcock without hub disinfection before injection, and 3.2% (5/154) for the conventional open-lumen stopcock. The Ultraport zero stopcock with hub disinfection before injection was associated with a significant reduction in the risk of bacterial injection as compared to the conventional open-lumen stopcock (RR = 8.15 × 10(-8), 95% CI, 3.39 × 10(-8) to 1.96 × 10(-7), P = <0.001), with an absolute risk reduction of 3.2% (95% CI, 0.5% to 7.4%). Provider glove use was a risk factor for effluent contamination (RR = 10.48, 95% CI, 3.16 to 34.80, P < 0.001). The estimated quantity of bacteria injected reached a clinically significant threshold of 50,000 colony-forming units per each injection series. CONCLUSIONS: The Ultraport zero stopcock with hub disinfection before injection was associated with a significant reduction in the risk of inadvertent bacterial injection as compared to the conventional open-lumen stopcock. Future studies should examine strategies designed to facilitate health care provider DNCC hub disinfection and proper device handling.


Asunto(s)
Catéteres/microbiología , Contaminación de Equipos/prevención & control , Diseño de Equipo/normas , Mano/microbiología , Personal de Salud/normas , Transmisión de Enfermedad Infecciosa de Profesional a Paciente/prevención & control , Adulto , Anciano , Femenino , Humanos , Control de Infecciones , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Método Simple Ciego , Células Madre/microbiología
4.
Anesth Analg ; 114(6): 1236-48, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22467892

RESUMEN

BACKGROUND: Intraoperative stopcock contamination is a frequent event associated with increased patient mortality. In the current study we examined the relative contributions of anesthesia provider hands, the patient, and the patient environment to stopcock contamination. Our secondary aims were to identify risk factors for stopcock contamination and to examine the prior association of stopcock contamination with 30-day postoperative infection and mortality. Additional microbiological analyses were completed to determine the prevalence of bacterial pathogens within intraoperative bacterial reservoirs. Pulsed-field gel electrophoresis was used to assess the contribution of reservoir bacterial pathogens to 30-day postoperative infections. METHODS: In a multicenter study, stopcock transmission events were observed in 274 operating rooms, with the first and second cases of the day in each operating room studied in series to identify within- and between-case transmission events. Reservoir bacterial cultures were obtained and compared with stopcock set isolates to determine the origin of stopcock contamination. Between-case transmission was defined by the isolation of 1 or more bacterial isolates from the stopcock set of a subsequent case (case 2) that were identical to reservoir isolates from the preceding case (case 1). Within-case transmission was defined by the isolation of 1 or more bacterial isolates from a stopcock set that were identical to bacterial reservoirs from the same case. Bacterial pathogens within these reservoirs were identified, and their potential contribution to postoperative infections was evaluated. All patients were followed for 30 days postoperatively for the development of infection and all-cause mortality. RESULTS: Stopcock contamination was detected in 23% (126 out of 548) of cases with 14 between-case and 30 within-case transmission events confirmed. All 3 reservoirs contributed to between-case (64% environment, 14% patient, and 21% provider) and within-case (47% environment, 23% patient, and 30% provider) stopcock transmission. The environment was a more likely source of stopcock contamination than provider hands (relative risk [RR] 1.91, confidence interval [CI] 1.09 to 3.35, P = 0.029) or patients (RR 2.56, CI 1.34 to 4.89, P = 0.002). Hospital site (odds ratio [OR] 5.09, CI 2.02 to 12.86, P = 0.001) and case 2 (OR 6.82, CI 4.03 to 11.5, P < 0.001) were significant predictors of stopcock contamination. Stopcock contamination was associated with increased mortality (OR 58.5, CI 2.32 to 1477, P = 0.014). Intraoperative bacterial contamination of patients and provider hands was linked to 30-day postoperative infections. CONCLUSIONS: Bacterial contamination of patients, provider hands, and the environment contributes to stopcock transmission events, but the surrounding patient environment is the most likely source. Stopcock contamination is associated with increased patient mortality. Patient and provider bacterial reservoirs contribute to 30-day postoperative infections. Multimodal programs designed to target each of these reservoirs in parallel should be studied intensely as a comprehensive approach to reducing intraoperative bacterial transmission.


Asunto(s)
Anestesiología/instrumentación , Infecciones Bacterianas/transmisión , Infección Hospitalaria/transmisión , Reservorios de Enfermedades , Ambiente Controlado , Contaminación de Equipos , Quirófanos , Infección de la Herida Quirúrgica/etiología , Adulto , Anciano , Axila/microbiología , Infecciones Bacterianas/microbiología , Infecciones Bacterianas/mortalidad , Infecciones Bacterianas/prevención & control , Técnicas Bacteriológicas , Infección Hospitalaria/microbiología , Infección Hospitalaria/mortalidad , Infección Hospitalaria/prevención & control , Electroforesis en Gel de Campo Pulsado , Femenino , Guantes Quirúrgicos/microbiología , Desinfección de las Manos , Humanos , Control de Infecciones , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Nasofaringe/microbiología , Oportunidad Relativa , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Infección de la Herida Quirúrgica/microbiología , Infección de la Herida Quirúrgica/mortalidad , Infección de la Herida Quirúrgica/prevención & control , Factores de Tiempo , Estados Unidos
5.
Anim Cogn ; 14(1): 117-25, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20838837

RESUMEN

Heterospecific cues, such as gaze direction and body position, may be an important source of information that an animal can use to infer the location of resources like food. The use of heterospecific cues has been largely investigated using primates, dogs, and other mammals; less is known about whether birds can also use heterospecific gestures. We tested six Clark's nutcrackers in a two-way object-choice task using touch, point, and gaze cues to investigate whether these birds can use human gestures to find food. Most of the birds were able to use a touch gesture during the first trial of testing and were able to learn to use point and gaze (eyes and head alternation) cues after a limited number of trials. This study is the first to test a non-social corvid on the object-choice task. The performance of non-social nutcrackers is similar to that of more social and related corvids, suggesting that species with different evolutionary histories can utilize gestural information.


Asunto(s)
Cognición , Passeriformes , Conducta Social , Animales , Conducta Alimentaria
SELECCIÓN DE REFERENCIAS