Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Front Cardiovasc Med ; 11: 1298346, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38287983

RESUMEN

Background: Treatment of severe aortic stenosis with transcatheter aortic valve implantation (TAVI) was introduced in 2002. Since then, TAVI has become the primary treatment approach worldwide for advanced-age patients and younger patients with severe comorbidities. We aimed to evaluate the changes in patient demographics, complications, and mortality rates within 13 years. Methods: This retrospective observational study included 867 patients who underwent TAVI at the University Hospital of North Norway in Tromsø from 2008 to 2021. The 13-year period was divided into period 1 (2008-2012), period 2 (2013-2017), and period 3 (2018-2021). The primary objective was to evaluate the changes in periprocedural (30 days), early (30-365 days), and late mortality rates (>365 days) between the periods. The secondary objective was to evaluate late mortality rates by sex and age groups: <70 years, 70-79 years, 80-89 years, and ≥90 years. Results: The periprocedural mortality rates for periods 1, 2, and 3 were 10.3%, 2.9%, and 1.2%, respectively (P < 0.001). The early mortality rates were 5.6%, 5.8%, and 6.5%, respectively. No significant differences were observed in late mortality by sex or age group (<70, 70-79, and 80-89 years) with a median survival of 5.3-5.6 years. The median survival in patients aged ≥90 years was 4.0 years (P = 0.018). Conclusion: Our findings indicate that most patients are octogenarians, and the burden of their comorbidities should be highly considered compared to their age when evaluating the procedural outcomes. As the incidence of most complications related to TAVI has decreased, the rates of permanent pacemaker implantation remain high. Important advancements in diagnostics, valve technology, and procedural techniques have improved the periprocedural mortality rates; however, early mortality remains unchanged and poses a clinical challenge that needs to be addressed in the future.

2.
JACC Cardiovasc Imaging ; 16(3): 332-341, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36889849

RESUMEN

BACKGROUND: Left ventricular ejection fraction (LVEF) demonstrates limited prognostic value for post-transcatheter aortic valve replacement (TAVR) outcomes. Evidence regarding the potential role of left ventricular global longitudinal strain (LV-GLS) in this setting is inconsistent. OBJECTIVES: The aim of this systematic review and meta-analysis of aggregated data was to evaluate the prognostic value of preprocedural LV-GLS for post-TAVR-related morbidity and mortality. METHODS: The authors searched PubMed, Embase, and Web of Science for studies investigating the association between preprocedural 2-dimensional speckle-tracking-derived LV-GLS and post-TAVR clinical outcomes. An inversely weighted random effects meta-analysis was adopted to investigate the association between LV-GLS vs primary (ie, all-cause mortality) and secondary (ie, major cardiovascular events [MACE]) post-TAVR outcomes. RESULTS: Of the 1,130 identified records, 12 were eligible, all of which had a low-to-moderate risk of bias (Newcastle-Ottawa scale). On average, 2,049 patients demonstrated preserved LVEF (52.6% ± 1.7%), but impaired LV-GLS (-13.6% ± 0.6%). Patients with a lower LV-GLS had a higher all-cause mortality (pooled HR: 2.01; 95% CI: 1.59-2.55) and MACE (pooled odds ratio [OR]: 1.26; 95% CI: 1.08-1.47) risk compared with patients with higher LV-GLS. In addition, each percentage point decrease of LV-GLS (ie, toward 0%) was associated with an increased mortality (HR: 1.06; 95% CI: 1.04-1.08) and MACE risk (OR: 1.08; 95% CI: 1.01-1.15). CONCLUSIONS: Preprocedural LV-GLS was significantly associated with post-TAVR morbidity and mortality. This suggests a potential clinically important role of pre-TAVR evaluation of LV-GLS for risk stratification of patients with severe aortic stenosis. (Prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis undergoing Transcatheter Aortic Valve Implantation: a meta-analysis; CRD42021289626).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Izquierda , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Izquierda , Pronóstico , Volumen Sistólico , Tensión Longitudinal Global , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
3.
Front Cardiovasc Med ; 8: 739710, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34938779

RESUMEN

Background: Transcatheter aortic valve implantation (TAVI) has become a standard treatment option for patients with symptomatic aortic stenosis. Elderly high-risk patients treated with TAVI have a high residual mortality due to preexisting comorbidities. Knowledge of factors predicting futility after TAVI is sparse and clinical tools to aid the preoperative evaluation are lacking. The aim of this study was to evaluate if echocardiographic measures, including speckle-tracking analysis, in addition to clinical parameters, could aid in the prediction of mortality beyond 30 days after TAVI. Methods: This prospective observational cohort study included 227 patients treated with TAVI at the University Hospital of North Norway, Tromsø and Oslo University Hospital, Rikshospitalet from February 2010 to June 2013. All the patients underwent preoperative echocardiographic evaluation with retrospective speckle-tracking analysis. Primary endpoints were 1- and 2-year mortality beyond 30 days after TAVI. Results: All-cause 1- and 2-year mortality beyond 30 days after TAVI was 12.1 and 19.5%, respectively. Predictors of 1-year mortality beyond 30 days were body mass index [hazard ratio (HR): 0.88, 95% CI: 0.80-0.98, p = 0.018], previous myocardial infarction (HR: 2.69, 95% CI: 1.14-6.32, p = 0.023), and systolic pulmonary artery pressure ≥ 60 mm Hg (HR: 5.93, 95% CI: 1.67-21.1, p = 0.006). Moderate-to-severe mitral regurgitation (HR: 2.93, 95% CI: 1.53-5.63, p = 0.001), estimated glomerular filtration rate (HR: 0.98, 95% CI: 0.96-0.99, p = 0.002), and chronic obstructive pulmonary disease (HR: 1.9, 95% CI: 1.01-3.58, p = 0.046) were predictors of 2-year mortality. Conclusion: Both the clinical and echocardiographic parameters should be considered when evaluating high-risk patients for TAVI, as both are predictive of 1-and 2-year mortality. Our results support the importance of individual risk assessment using a multidisciplinary, multimodal, and individual approach.

4.
Cardiovasc Ultrasound ; 19(1): 32, 2021 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-34583696

RESUMEN

BACKGROUND: The 2016 guidelines of the American Society of Echocardiography (ASE) and European Association of Cardiovascular Imaging (EACVI) for evaluation of left ventricular (LV) diastolic dysfunction by Doppler flow and tissue Doppler- echocardiography do not adjust assessment of high filling pressures for patients with aortic stenosis (AS). However, most of the studies on this patient group indicate age independent specific diastolic features in AS. The aim of this study is to identify disease-specific range and distribution of diastolic functional parameters and their ability to identify high N-terminal prohormone of brain natriuretic peptide (NT-proBNP) levels as a marker for high filling pressures. METHODS: In this study, 169 patients who underwent surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) were prospectively enrolled. Resting echocardiography was performed including Doppler of the mitral inflow, pulmonary venous flow, tricuspid regurgitant flow and tissue Doppler in the mitral ring and indexed volume-estimates of the left atrium (LAVI). Echocardiography, and NT-proBNP levels were assessed before TAVR/SAVR and at two postoperative visits at 6 and 12 months. RESULTS: Pre- and postoperative values were septal e'; 5.1 ± 3.9, 5.2 ± 1.6 cm/s; lateral e' 6.3 ± 2.1; 7.7 ± 2.7 cm/s; E/e'19 ± 8; 16 ± 7 cm/s; E velocity 96 ± 32; 95 ± 32 cm/s; LAVI 39 ± 8; 36 ± 8 ml/m2, pulmonary artery pressure (PAP) 39 ± 8; 36 ± 8 mmHg, respectively. The scoring recommended by ASE/EACVI detected elevated NT pro-BNP with a specificity of 25%. Adjusting thresholds towards PAP ≥ 40 mmHg, E velocity ≥ 100 cm/s, E deceleration time < 220 ms, and E/septal e' ≥ 20 or septal e' < 5.0 cm/s increased prediction of NT-proBNP levels ≥500 ng/L with substantially improved specificity (> 85%). CONCLUSION: Diastolic echocardiographic parameters in AS indicate persistent impaired relaxation and NT-proBNP indicate elevated filling pressures in most of the patients, improving only modestly 6-12 months after TAVR and SAVR. Applying the 2016 ASE/EACVI recommendations for detection of elevated filling pressures to patients with AS, elevated NT pro-BNP levels could not be reliably detected. However, adjusting thresholds of the echocardiographic parameters increased specificities to useful diagnostic levels. TRIAL REGISTRATION: The study was prospectively approved by the regional ethical committee, REK North with the registration number: REK 2010/397-10 .


Asunto(s)
Estenosis de la Válvula Aórtica , Disfunción Ventricular Izquierda , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Diástole , Ecocardiografía , Ecocardiografía Doppler , Humanos , Péptido Natriurético Encefálico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología
5.
Ultrasound Med Biol ; 47(11): 3079-3089, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34392996

RESUMEN

The aim of this study was to determine the accuracy and reproducibility of vendor-specific regional strain values by echocardiography using in silico data. Synthetic 2-D ultrasound gray-scale images of the left ventricle (LV) were generated with knowledge of the longitudinal segmental strain values from the underlying electromechanical LV model. Four of five models mimicked transmural infarctions with systolic segmental stretching in different vascular areas. Cine loops in the three apical views were synthetically generated at four noise levels. All in silico images were repeatedly analyzed by a single investigator and some by another investigator. The absolute errors varied significantly between vendors from 3.3 ± 3.1% to 11.2 ± 5.9%. The area under the curve for the identification of segmental stretching ranged from 0.80 (confidence interval: 0.77-0.83) to 0.96 (0.95-0.98). The levels of agreement for intra-investigator variability varied between -3.0% to 2.9% and -5.2% to 4.8%, and for inter-investigator variability, between -3.6% to 3.5% and -14.5% to 8.5%. Segmental strain analysis allows the identification of areas with segmental stretching with good accuracy. However, single segmental peak-strain values are not accurate and should be interpreted with caution. Nevertheless, our results indicate the usefulness of semiquantitative strain assessment for the detection of regional dysfunction.


Asunto(s)
Ecocardiografía , Ventrículos Cardíacos , Ventrículos Cardíacos/diagnóstico por imagen , Estándares de Referencia , Reproducibilidad de los Resultados , Sístole , Función Ventricular Izquierda
6.
Health Sci Rep ; 4(2): e283, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33977165

RESUMEN

OBJECTIVES: Transcatheter aortic valve implantation (TAVI)-specific risk scores have been developed based on large registry studies. Our aim was to evaluate how both surgical and novel TAVI risk scores performed in predicting all cause 30-day mortality. In addition, we wanted to explore the validity of our own previously developed model in a separate and more recent cohort. METHODS: The derivation cohort included patients not eligible for open surgery treated with TAVI at the University Hospital of North Norway (UNN) and Oslo University Hospital (OUS) from February 2010 through June 2013. From this cohort, a logistic prediction model (UNN/OUS) for all cause 30-day mortality was developed. The validation cohort consisted of patients not included in the derivation cohort and treated with TAVI at UNN between June 2010 and April 2017. EuroSCORE, Logistic EuroSCORE, EurosSCORE 2, STS score, German AV score, OBSERVANT score, IRRMA score, and FRANCE-2 score were calculated for both cohorts. The discriminative accuracy of each score, including our model, was evaluated by receiver operating characteristic (ROC) analysis and compared using DeLong test where P< .05 was considered statistically significant. RESULTS: The derivation cohort consisted of 218 and the validation cohort of 241 patients. Our model showed statistically significant better accuracy than all other scores in the derivation cohort. In the validation cohort, the FRANCE-2 had a significantly higher predictive accuracy compared to all scores except the IRRMA and STS score. Our model showed similar results. CONCLUSION: Existing risk scores have shown limited accuracy in predicting early mortality after TAVI. Our results indicate that TAVI-specific risk scores might be useful when evaluating patients for TAVI.

7.
Open Heart ; 6(1): e000936, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31168372

RESUMEN

Objectives: To investigate whether preoperative echocardiographic evaluation of ventricular function, especially right ventricular systolic and diastolic parameters including speckle-tracking analysis, could aid in the prediction of 30-day mortality after transcatheter aortic valve implantation (TAVI) in patients with aortic stenosis. Methods: This is a prospective observational cohort study including 227 patients accepted for TAVI at the University Hospital of North Norway and Oslo University Hospital from February 2010 through June 2013. All patients underwent preoperative transthoracic echocardiography with retrospective speckle-tracking analysis. Primary endpoint was all-cause 30-day mortality. Results: All-cause 30-day mortality was 8.7 % (n = 19). Independent predictors of 30-day mortality were systolic pulmonary arterial pressure (SPAP) > 60 mm Hg (HR: 7.7, 95% CI: 1.90 to 31.3), heart failure (HR: 2.9, 95% CI: 1.1 to 7.78), transapical access (HR: 3.8, 95% CI: 1.3 to 11.2), peripheral artery disease (HR: 6.0, 95% CI: 2.0 to 18.0) and body mass index (HR: 0.73, 95% CI: 0.61 to 0.87). C-statistic for the model generated was 0.91 (95% CI: 0.85 to 0.98). Besides elevated SPAP, no other echocardiographic measurements were found to be an independent predictor of early mortality. Conclusion: Except for elevated systolic pulmonary artery pressure, our data suggests that clinical rather than echocardiographic parameters are useful predictors of 30-day mortality after TAVI.

8.
Eur Heart J Cardiovasc Imaging ; 16(10): 1137-47, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25762560

RESUMEN

AIMS: Ultrasound-derived myocardial strain can render valuable diagnostic and prognostic information. However, acquisition settings can have an important impact on the measurements. Frame rate (i.e. temporal resolution) seems to be of particular importance. The aim of this study was to find the optimal range of frame rates needed for most accurate and reproducible 2D strain measurements using a 2D speckle-tracking software package. METHODS AND RESULTS: Synthetic two dimensional (2D) ultrasound grey-scale images of the left ventricle (LV) were generated in which the strain in longitudinal, circumferential, and radial direction were precisely known from the underlying kinematic LV model. Four different models were generated at frame rates between 20 and 110 Hz. The resulting images were repeatedly analysed. Results of the synthetic data were validated in 66 patients, where long- and short-axis recordings at different frame rates were analysed. In simulated data, accurate strain estimates could be achieved at >30 frames per cycle (FpC) for longitudinal and circumferential strains. Lower FpC underestimated strain systematically. Radial strain estimates were less accurate and less reproducible. Patient strain displayed the same plateaus as in the synthetic models. Higher noise and the presence of artefacts in patient data were followed by higher measurement variability. CONCLUSION: Standard machine settings with a FR of 50-60 Hz allow correct assessment of peak global longitudinal and circumferential strain. Correct definition of the region of interest within the myocardium as well as the reduction of noise and artefacts seem to be of highest importance for accurate 2D strain estimation.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/fisiopatología , Ecocardiografía/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Contracción Miocárdica/fisiología , Simulación por Computador , Humanos , Reproducibilidad de los Resultados , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...