Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
BMJ Open ; 14(5): e081317, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692728

RESUMEN

INTRODUCTION: Gait and mobility impairment are pivotal signs of parkinsonism, and they are particularly severe in atypical parkinsonian disorders including multiple system atrophy (MSA) and progressive supranuclear palsy (PSP). A pilot study demonstrated a significant improvement of gait in patients with MSA of parkinsonian type (MSA-P) after physiotherapy and matching home-based exercise, as reflected by sensor-based gait parameters. In this study, we aim to investigate whether a gait-focused physiotherapy (GPT) and matching home-based exercise lead to a greater improvement of gait performance compared with a standard physiotherapy/home-based exercise programme (standard physiotherapy, SPT). METHODS AND ANALYSIS: This protocol was deployed to evaluate the effects of a GPT versus an active control undergoing SPT and matching home-based exercise with regard to laboratory gait parameters, physical activity measures and clinical scales in patients with Parkinson's disease (PD), MSA-P and PSP. The primary outcomes of the trial are sensor-based laboratory gait parameters, while the secondary outcome measures comprise real-world derived parameters, clinical rating scales and patient questionnaires. We aim to enrol 48 patients per disease group into this double-blind, randomised-controlled trial. The study starts with a 1 week wearable sensor-based monitoring of physical activity. After randomisation, patients undergo a 2 week daily inpatient physiotherapy, followed by 5 week matching unsupervised home-based training. A 1 week physical activity monitoring is repeated during the last week of intervention. ETHICS AND DISSEMINATION: This study, registered as 'Mobility in Atypical Parkinsonism: a Trial of Physiotherapy (Mobility_APP)' at clinicaltrials.gov (NCT04608604), received ethics approval by local committees of the involved centres. The patient's recruitment takes place at the Movement Disorders Units of Innsbruck (Austria), Erlangen (Germany), Lausanne (Switzerland), Luxembourg (Luxembourg) and Bolzano (Italy). The data resulting from this project will be submitted to peer-reviewed journals, presented at international congresses and made publicly available at the end of the trial. TRIAL REGISTRATION NUMBER: NCT04608604.


Asunto(s)
Terapia por Ejercicio , Trastornos Parkinsonianos , Modalidades de Fisioterapia , Humanos , Terapia por Ejercicio/métodos , Trastornos Parkinsonianos/rehabilitación , Trastornos Parkinsonianos/terapia , Método Doble Ciego , Ensayos Clínicos Controlados Aleatorios como Asunto , Marcha , Enfermedad de Parkinson/rehabilitación , Enfermedad de Parkinson/terapia , Atrofia de Múltiples Sistemas/rehabilitación , Atrofia de Múltiples Sistemas/terapia , Parálisis Supranuclear Progresiva/terapia , Parálisis Supranuclear Progresiva/rehabilitación , Servicios de Atención de Salud a Domicilio , Anciano , Masculino , Femenino , Trastornos Neurológicos de la Marcha/rehabilitación , Trastornos Neurológicos de la Marcha/etiología
3.
JMIR Form Res ; 8: e50035, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691395

RESUMEN

BACKGROUND: Wrist-worn inertial sensors are used in digital health for evaluating mobility in real-world environments. Preceding the estimation of spatiotemporal gait parameters within long-term recordings, gait detection is an important step to identify regions of interest where gait occurs, which requires robust algorithms due to the complexity of arm movements. While algorithms exist for other sensor positions, a comparative validation of algorithms applied to the wrist position on real-world data sets across different disease populations is missing. Furthermore, gait detection performance differences between the wrist and lower back position have not yet been explored but could yield valuable information regarding sensor position choice in clinical studies. OBJECTIVE: The aim of this study was to validate gait sequence (GS) detection algorithms developed for the wrist position against reference data acquired in a real-world context. In addition, this study aimed to compare the performance of algorithms applied to the wrist position to those applied to lower back-worn inertial sensors. METHODS: Participants with Parkinson disease, multiple sclerosis, proximal femoral fracture (hip fracture recovery), chronic obstructive pulmonary disease, and congestive heart failure and healthy older adults (N=83) were monitored for 2.5 hours in the real-world using inertial sensors on the wrist, lower back, and feet including pressure insoles and infrared distance sensors as reference. In total, 10 algorithms for wrist-based gait detection were validated against a multisensor reference system and compared to gait detection performance using lower back-worn inertial sensors. RESULTS: The best-performing GS detection algorithm for the wrist showed a mean (per disease group) sensitivity ranging between 0.55 (SD 0.29) and 0.81 (SD 0.09) and a mean (per disease group) specificity ranging between 0.95 (SD 0.06) and 0.98 (SD 0.02). The mean relative absolute error of estimated walking time ranged between 8.9% (SD 7.1%) and 32.7% (SD 19.2%) per disease group for this algorithm as compared to the reference system. Gait detection performance from the best algorithm applied to the wrist inertial sensors was lower than for the best algorithms applied to the lower back, which yielded mean sensitivity between 0.71 (SD 0.12) and 0.91 (SD 0.04), mean specificity between 0.96 (SD 0.03) and 0.99 (SD 0.01), and a mean relative absolute error of estimated walking time between 6.3% (SD 5.4%) and 23.5% (SD 13%). Performance was lower in disease groups with major gait impairments (eg, patients recovering from hip fracture) and for patients using bilateral walking aids. CONCLUSIONS: Algorithms applied to the wrist position can detect GSs with high performance in real-world environments. Those periods of interest in real-world recordings can facilitate gait parameter extraction and allow the quantification of gait duration distribution in everyday life. Our findings allow taking informed decisions on alternative positions for gait recording in clinical studies and public health. TRIAL REGISTRATION: ISRCTN Registry 12246987; https://www.isrctn.com/ISRCTN12246987. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2021-050785.

4.
Res Sq ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38559043

RESUMEN

Progressive gait impairment is common in aging adults. Remote phenotyping of gait during daily living has the potential to quantify gait alterations and evaluate the effects of interventions that may prevent disability in the aging population. Here, we developed ElderNet, a self-supervised learning model for gait detection from wrist-worn accelerometer data. Validation involved two diverse cohorts, including over 1,000 participants without gait labels, as well as 83 participants with labeled data: older adults with Parkinson's disease, proximal femoral fracture, chronic obstructive pulmonary disease, congestive heart failure, and healthy adults. ElderNet presented high accuracy (96.43 ± 2.27), specificity (98.87 ± 2.15), recall (82.32 ± 11.37), precision (86.69 ± 17.61), and F1 score (82.92 ± 13.39). The suggested method yielded superior performance compared to two state-of-the-art gait detection algorithms, with improved accuracy and F1 score (p < 0.05). In an initial evaluation of construct validity, ElderNet identified differences in estimated daily walking durations across cohorts with different clinical characteristics, such as mobility disability (p < 0.001) and parkinsonism (p < 0.001). The proposed self-supervised gait detection method has the potential to serve as a valuable tool for remote phenotyping of gait function during daily living in aging adults.

5.
IEEE Open J Eng Med Biol ; 5: 163-172, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38487091

RESUMEN

Goal: Gait analysis using inertial measurement units (IMUs) has emerged as a promising method for monitoring movement disorders. However, the lack of public data and easy-to-use open-source algorithms hinders method comparison and clinical application development. To address these challenges, this publication introduces the gaitmap ecosystem, a comprehensive set of open source Python packages for gait analysis using foot-worn IMUs. Methods: This initial release includes over 20 state-of-the-art algorithms, enables easy access to seven datasets, and provides eight benchmark challenges with reference implementations. Together with its extensive documentation and tooling, it enables rapid development and validation of new algorithm and provides a foundation for novel clinical applications. Conclusion: The published software projects represent a pioneering effort to establish an open-source ecosystem for IMU-based gait analysis. We believe that this work can democratize the access to high-quality algorithm and serve as a driver for open and reproducible research in the field of human gait analysis and beyond.

6.
Sci Rep ; 14(1): 1754, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38243008

RESUMEN

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.


Asunto(s)
Velocidad al Caminar , Dispositivos Electrónicos Vestibles , Humanos , Anciano , Marcha , Caminata , Proyectos de Investigación
7.
Front Neurol ; 14: 1247532, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909030

RESUMEN

Introduction: The clinical assessment of mobility, and walking specifically, is still mainly based on functional tests that lack ecological validity. Thanks to inertial measurement units (IMUs), gait analysis is shifting to unsupervised monitoring in naturalistic and unconstrained settings. However, the extraction of clinically relevant gait parameters from IMU data often depends on heuristics-based algorithms that rely on empirically determined thresholds. These were mainly validated on small cohorts in supervised settings. Methods: Here, a deep learning (DL) algorithm was developed and validated for gait event detection in a heterogeneous population of different mobility-limiting disease cohorts and a cohort of healthy adults. Participants wore pressure insoles and IMUs on both feet for 2.5 h in their habitual environment. The raw accelerometer and gyroscope data from both feet were used as input to a deep convolutional neural network, while reference timings for gait events were based on the combined IMU and pressure insoles data. Results and discussion: The results showed a high-detection performance for initial contacts (ICs) (recall: 98%, precision: 96%) and final contacts (FCs) (recall: 99%, precision: 94%) and a maximum median time error of -0.02 s for ICs and 0.03 s for FCs. Subsequently derived temporal gait parameters were in good agreement with a pressure insoles-based reference with a maximum mean difference of 0.07, -0.07, and <0.01 s for stance, swing, and stride time, respectively. Thus, the DL algorithm is considered successful in detecting gait events in ecologically valid environments across different mobility-limiting diseases.

8.
Orphanet J Rare Dis ; 18(1): 249, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37644478

RESUMEN

BACKGROUND: Hereditary spastic paraplegias (HSPs) cause characteristic gait impairment leading to an increased risk of stumbling or even falling. Biomechanically, gait deficits are characterized by reduced ranges of motion in lower body joints, limiting foot clearance and ankle range of motion. To date, there is no standardized approach to continuously and objectively track the degree of dysfunction in foot elevation since established clinical rating scales require an experienced investigator and are considered to be rather subjective. Therefore, digital disease-specific biomarkers for foot elevation are needed. METHODS: This study investigated the performance of machine learning classifiers for the automated detection and classification of reduced foot dorsiflexion and clearance using wearable sensors. Wearable inertial sensors were used to record gait patterns of 50 patients during standardized 4 [Formula: see text] 10 m walking tests at the hospital. Three movement disorder specialists independently annotated symptom severity. The majority vote of these annotations and the wearable sensor data were used to train and evaluate machine learning classifiers in a nested cross-validation scheme. RESULTS: The results showed that automated detection of reduced range of motion and foot clearance was possible with an accuracy of 87%. This accuracy is in the range of individual annotators, reaching an average accuracy of 88% compared to the ground truth majority vote. For classifying symptom severity, the algorithm reached an accuracy of 74%. CONCLUSION: Here, we show that the present wearable gait analysis system is able to objectively assess foot elevation patterns in HSP. Future studies will aim to improve the granularity for continuous tracking of disease severity and monitoring therapy response of HSP patients in a real-world environment.


Asunto(s)
Paraplejía Espástica Hereditaria , Humanos , Adulto , Paraplejía Espástica Hereditaria/diagnóstico , Algoritmos , Marcha , Hospitales , Aprendizaje Automático
9.
Int J Med Inform ; 177: 105145, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37473657

RESUMEN

BACKGROUND: Gait and cognition impairments are common problems among People with Multiple Sclerosis (PwMS). Previous studies have investigated cross-sectional associations between gait and cognition. However, there is a lack of evidence regarding the longitudinal association between these factors in PwMS. Therefore, the objective of this study was to explore this longitudinal relationship using smartphone-based data from the Floodlight study. METHODS: Using the publicly available Floodlight dataset, which contains smartphone-based longitudinal data, we used a linear mixed model to investigate the longitudinal relationship between cognition, measured by the Symbol Digit Modalities Test (SDMT), and gait, measured by the 2 Minute Walking test (2 MW) step count and Five-U-Turn Test (FUTT) turning speed. Four mixed models were fitted to explore the association between: 1) SDMT and mean step count; 2) SDMT and variability of step count; 3) SDMT and mean FUTT turning speed; and 4) SDMT and variability of FUTT turningt speed. RESULTS: After controlling for age, sex, weight, and height, there were significant correlations between SDMT and the variability of 2 MW step count, the mean of FUTT turning speed. No significant correlation was observed between SDMT and the 2 MW mean step count. SIGNIFICANCE: Our findings support the evidence that gait and cognition are associated in PwMS. This may support clinicians to adjust treatment and intervention programs that address both gait and cognitive impairments.


Asunto(s)
Esclerosis Múltiple , Humanos , Esclerosis Múltiple/complicaciones , Estudios Transversales , Teléfono Inteligente , Marcha , Cognición
10.
J Neuroeng Rehabil ; 20(1): 78, 2023 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-37316858

RESUMEN

BACKGROUND: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. METHODS: Twenty healthy older adults, 20 people with Parkinson's disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. RESULTS: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms' performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. CONCLUSIONS: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms' performances. Trial registration ISRCTN - 12246987.


Asunto(s)
Tecnología Digital , Fracturas Femorales Proximales , Humanos , Anciano , Marcha , Caminata , Velocidad al Caminar , Modalidades de Fisioterapia
11.
Front Bioeng Biotechnol ; 11: 1143248, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37214281

RESUMEN

Introduction: Accurately assessing people's gait, especially in real-world conditions and in case of impaired mobility, is still a challenge due to intrinsic and extrinsic factors resulting in gait complexity. To improve the estimation of gait-related digital mobility outcomes (DMOs) in real-world scenarios, this study presents a wearable multi-sensor system (INDIP), integrating complementary sensing approaches (two plantar pressure insoles, three inertial units and two distance sensors). Methods: The INDIP technical validity was assessed against stereophotogrammetry during a laboratory experimental protocol comprising structured tests (including continuous curvilinear and rectilinear walking and steps) and a simulation of daily-life activities (including intermittent gait and short walking bouts). To evaluate its performance on various gait patterns, data were collected on 128 participants from seven cohorts: healthy young and older adults, patients with Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, congestive heart failure, and proximal femur fracture. Moreover, INDIP usability was evaluated by recording 2.5-h of real-world unsupervised activity. Results and discussion: Excellent absolute agreement (ICC >0.95) and very limited mean absolute errors were observed for all cohorts and digital mobility outcomes (cadence ≤0.61 steps/min, stride length ≤0.02 m, walking speed ≤0.02 m/s) in the structured tests. Larger, but limited, errors were observed during the daily-life simulation (cadence 2.72-4.87 steps/min, stride length 0.04-0.06 m, walking speed 0.03-0.05 m/s). Neither major technical nor usability issues were declared during the 2.5-h acquisitions. Therefore, the INDIP system can be considered a valid and feasible solution to collect reference data for analyzing gait in real-world conditions.

12.
Age Ageing ; 52(1)2023 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-36729471

RESUMEN

BACKGROUND: walking is crucial for an active and healthy ageing, but the perspectives of individuals living with walking impairment are still poorly understood. OBJECTIVES: to identify and synthesise evidence describing walking as experienced by adults living with mobility-impairing health conditions and to propose an empirical conceptual framework of walking experience. METHODS: we performed a systematic review and meta-ethnography of qualitative evidence, searching seven electronic databases for records that explored personal experiences of walking in individuals living with conditions of diverse aetiology. Conditions included Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, hip fracture, heart failure, frailty and sarcopenia. Data were extracted, critically appraised using the NICE quality checklist and synthesised using standardised best practices. RESULTS: from 2,552 unique records, 117 were eligible. Walking experience was similar across conditions and described by seven themes: (i) becoming aware of the personal walking experience, (ii) the walking experience as a link between individuals' activities and sense of self, (iii) the physical walking experience, (iv) the mental and emotional walking experience, (v) the social walking experience, (vi) the context of the walking experience and (vii) behavioural and attitudinal adaptations resulting from the walking experience. We propose a novel conceptual framework that visually represents the walking experience, informed by the interplay between these themes. CONCLUSION: a multi-faceted and dynamic experience of walking was common across health conditions. Our conceptual framework of the walking experience provides a novel theoretical structure for patient-centred clinical practice, research and public health.


Asunto(s)
Antropología Cultural , Caminata , Humanos , Investigación Cualitativa , Antropología Cultural/métodos
13.
Sci Data ; 10(1): 38, 2023 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-36658136

RESUMEN

Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual's mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility, and external validation. In this study, we aim at providing an example of how movement data (from the real-world and the laboratory) recorded from different wearables and gold standard technologies can be organized, integrated, and stored. We leveraged on our experience from a large multi-centric study (Mobilise-D) to provide guidelines that can prove useful to access, understand, and re-use the data that will be made available from the study. These guidelines highlight the encountered challenges and the adopted solutions with the final aim of supporting standardization and integration of data in other studies and, in turn, to increase and facilitate comparison of data recorded in the scientific community. We also provide samples of standardized data, so that both the structure of the data and the procedure can be easily understood and reproduced.

14.
IEEE J Biomed Health Inform ; 27(1): 319-328, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36260566

RESUMEN

Falls are an eminent risk for older adults and especially patients with neurodegenerative disorders, such as Parkinson's disease (PD). Recent advancements in wearable sensor technology and machine learning may provide a possibility for an individualized prediction of fall risk based on gait recordings from standardized gait tests or from unconstrained real-world scenarios. However, the most effective aggregation of continuous real-world data as well as the potential of unsupervised gait tests recorded over multiple days for fall risk prediction still need to be investigated. Therefore, we present a data set containing real-world gait and unsupervised 4x10-Meter-Walking-Tests of 40 PD patients, continuously recorded with foot-worn inertial sensors over a period of two weeks. In this prospective study, falls were self-reported during a three-month follow-up phase, serving as ground truth for fall risk prediction. The purpose of this study was to compare different data aggregation approaches and machine learning models for the prospective prediction of fall risk using gait parameters derived either from continuous real-world recordings or from unsupervised gait tests. The highest balanced accuracy of 74.0% (sensitivity: 60.0%, specificity: 88.0%) was achieved with a Random Forest Classifier applied to the real-world gait data when aggregating all walking bouts and days of each participant. Our findings suggest that fall risk can be predicted best by merging the entire two-week real-world gait data of a patient, outperforming the prediction using unsupervised gait tests (68.0% balanced accuracy) and contribute to an improved understanding of fall risk prediction.


Asunto(s)
Enfermedad de Parkinson , Dispositivos Electrónicos Vestibles , Humanos , Anciano , Estudios Prospectivos , Marcha , Caminata
15.
J Neuroeng Rehabil ; 19(1): 141, 2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36522646

RESUMEN

BACKGROUND: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. METHODS: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants' strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson's disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. RESULTS: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. CONCLUSIONS: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. TRIAL REGISTRATION: ISRCTN-12246987.


Asunto(s)
Marcha , Enfermedad de Parkinson , Adulto , Humanos , Caminata , Velocidad al Caminar , Proyectos de Investigación
16.
Front Med (Lausanne) ; 9: 954056, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35935756

RESUMEN

Introduction: Rheport is an online rheumatology referral system allowing automatic appointment triaging of new rheumatology patient referrals according to the respective probability of an inflammatory rheumatic disease (IRD). Previous research reported that Rheport was well accepted among IRD patients. Its accuracy was, however, limited, currently being based on an expert-based weighted sum score. This study aimed to evaluate whether machine learning (ML) models could improve this limited accuracy. Materials and methods: Data from a national rheumatology registry (RHADAR) was used to train and test nine different ML models to correctly classify IRD patients. Diagnostic performance was compared of ML models and the current algorithm was compared using the area under the receiver operating curve (AUROC). Feature importance was investigated using shapley additive explanation (SHAP). Results: A complete data set of 2265 patients was used to train and test ML models. 30.5% of patients were diagnosed with an IRD, 69.3% were female. The diagnostic accuracy of the current Rheport algorithm (AUROC of 0.534) could be improved with all ML models, (AUROC ranging between 0.630 and 0.737). Targeting a sensitivity of 90%, the logistic regression model could double current specificity (17% vs. 33%). Finger joint pain, inflammatory marker levels, psoriasis, symptom duration and female sex were the five most important features of the best performing logistic regression model for IRD classification. Conclusion: In summary, ML could improve the accuracy of a currently used rheumatology online referral system. Including further laboratory parameters and enabling individual feature importance adaption could increase accuracy and lead to broader usage.

17.
Sensors (Basel) ; 22(15)2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35957406

RESUMEN

Developing machine learning algorithms for time-series data often requires manual annotation of the data. To do so, graphical user interfaces (GUIs) are an important component. Existing Python packages for annotation and analysis of time-series data have been developed without addressing adaptability, usability, and user experience. Therefore, we developed a generic open-source Python package focusing on adaptability, usability, and user experience. The developed package, Machine Learning and Data Analytics (MaD) GUI, enables developers to rapidly create a GUI for their specific use case. Furthermore, MaD GUI enables domain experts without programming knowledge to annotate time-series data and apply algorithms to it. We conducted a small-scale study with participants from three international universities to test the adaptability of MaD GUI by developers and to test the user interface by clinicians as representatives of domain experts. MaD GUI saves up to 75% of time in contrast to using a state-of-the-art package. In line with this, subjective ratings regarding usability and user experience show that MaD GUI is preferred over a state-of-the-art package by developers and clinicians. MaD GUI reduces the effort of developers in creating GUIs for time-series analysis and offers similar usability and user experience for clinicians as a state-of-the-art package.


Asunto(s)
Programas Informáticos , Interfaz Usuario-Computador , Algoritmos , Humanos , Aprendizaje Automático
18.
PLoS One ; 17(6): e0269567, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35679231

RESUMEN

Gait analysis using foot-worn inertial measurement units has proven to be a reliable tool to diagnose and monitor many neurological and musculoskeletal indications. However, only few studies have investigated the robustness of such systems to changes in the sensor attachment and no consensus for suitable sensor positions exists in the research community. Specifically for unsupervised real-world measurements, understanding how the reliability of the monitoring system changes when the sensor is attached differently is from high importance. In these scenarios, placement variations are expected because of user error or personal preferences. In this manuscript, we present the largest study to date comparing different sensor positions and attachments. We recorded 9000 strides with motion-capture reference from 14 healthy participants with six synchronized sensors attached at each foot. Spatial gait parameters were calculated using a double-integration method and compared to the reference system. The results indicate that relevant differences in the accuracy of the stride length exists between the sensor positions. While the average error over multiple strides is comparable, single stride errors and variability parameters differ greatly. We further present a physics model and an analysis of the raw sensor data to understand the origin of the observed differences. This analysis indicates that a variety of attachment parameters can influence the systems' performance. While this is only the starting point to understand and mitigate these types of errors, we conclude that sensor systems and algorithms must be reevaluated when the sensor position or attachment changes.


Asunto(s)
Pie , Caminata , Algoritmos , Marcha , Análisis de la Marcha , Humanos , Reproducibilidad de los Resultados
19.
IEEE J Biomed Health Inform ; 26(9): 4733-4742, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35759602

RESUMEN

Falls are among the leading causes of injuries or death for the elderly, and the prevalence is especially high for patients suffering from neurological diseases like Parkinson's disease (PD). Today, inertial measurement units (IMUs) can be integrated unobtrusively into patients' everyday lives to monitor various mobility and gait parameters, which are related to common risk factors like reduced balance or reduced lower-limb muscle strength. Although stair ambulation is a fundamental part of everyday life and is known for its unique challenges for the gait and balance system, long-term gait analysis studies have not investigated real-world stair ambulation parameters yet. Therefore, we applied a recently published gait analysis pipeline on foot-worn IMU data of 40 PD patients over a recording period of two weeks to extract objective gait parameters from level walking but also from stair ascending and descending. In combination with prospective fall records, we investigated group differences in gait parameters of future fallers compared to non-fallers for each individual gait activity. We found significant differences in stair ascending and descending parameters. Stance time was increased by up to 20 % and gait speed reduced by up to 16 % for fallers compared to non-fallers during stair walking. These differences were not present in level walking parameters. This suggests that real-world stair ambulation provides sensitive parameters for mobility and fall risk due to the challenges stairs add to the balance and control system. Our work complements existing gait analysis studies by adding new insights into mobility and gait performance during real-world gait.


Asunto(s)
Enfermedad de Parkinson , Anciano , Marcha/fisiología , Humanos , Equilibrio Postural/fisiología , Estudios Prospectivos , Caminata/fisiología
20.
Sensors (Basel) ; 22(9)2022 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-35591054

RESUMEN

Indoor localization and human activity recognition are two important sources of information to provide context-based assistance. This information is relevant in ambient assisted living (AAL) scenarios, where older adults usually need supervision and assistance in their daily activities. However, indoor localization and human activity recognition have been mostly considered isolated problems. This work presents and evaluates a framework that takes advantage of the relationship between location and activity to simultaneously perform indoor localization, mapping, and human activity recognition. The proposed framework provides a non-intrusive configuration, which fuses data from an inertial measurement unit (IMU) placed in the person's shoe, with proximity and human activity-related data from Bluetooth low energy beacons (BLE) deployed in the indoor environment. A variant of the simultaneous location and mapping (SLAM) framework was used to fuse the location and human activity recognition (HAR) data. HAR was performed using data streaming algorithms. The framework was evaluated in a pilot study, using data from 22 people, 11 young people, and 11 older adults (people aged 65 years or older). As a result, seven activities of daily living were recognized with an F1 score of 88%, and the in-door location error was 0.98 ± 0.36 m for the young and 1.02 ± 0.24 m for the older adults. Furthermore, there were no significant differences between the groups, indicating that our proposed method works adequately in broad age ranges.


Asunto(s)
Inteligencia Ambiental , Actividades Cotidianas , Adolescente , Anciano , Algoritmos , Actividades Humanas , Humanos , Proyectos Piloto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...