Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cardiovasc Eng Technol ; 10(3): 469-481, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31236828

RESUMEN

PURPOSE: It is believed that non-physiological leakage flow through hinge gaps during diastole contributes to thrombus formation in Bileaflet Mechanical Heart Valves (BMHVs). Because of the small scale and difficulty of experimental access, fluid dynamics inside the hinge cavity has not yet been characterised in detail. The objective is to investigate small-scale structure inside the hinge experimentally, and gain insight into its role in stimulating cellular responses. METHODS: An optically accessible scaled-up model of a BMHV hinge was designed and built, preserving dynamic similarity to a clinical BMHV. Particle Image Velocimetry (PIV) was used to visualize and quantify the flow fields inside the hinge at physiological Reynolds number and dimensionless pressure drop. The flow was measured at in-plane and out-of-plane spatial resolution of 32 and 86 µm, respectively, and temporal resolution of [Formula: see text] RESULTS: Likely flow separation on the ventricular surface of the cavity has been observed for the first time, and is a source of unsteadiness and perhaps turbulence. The shear stress found in all planes exceeds the threshold of platelet activation, ranging up to 168 Pa. CONCLUSIONS: The scale-up approach provided new insight into the nature of the hinge flow and enhanced understanding of its complexity. This study revealed flow features that may induce blood element damage.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Velocidad del Flujo Sanguíneo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Ensayo de Materiales , Diseño de Prótesis , Estrés Mecánico , Trombosis/etiología , Trombosis/fisiopatología
2.
J Biomech Eng ; 137(11): 111008, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26291041

RESUMEN

In flow through cardiovascular implants, hemolysis, and thrombosis may be initiated by nonphysiological shear stress on blood elements. To enhance understanding of the small-scale flow structures that stimulate cellular responses, and ultimately to design devices for reduced blood damage, it is necessary to study the flow-field at high spatial and temporal resolution. In this work, we investigate flow in the reverse leakage jet from the hinge of a bileaflet mechanical heart valve (BMHV). Scaled-up model hinges are employed, enabling measurement of the flow-field at effective spatial resolution of 167 µm and temporal resolution of 594 µs using two-component particle image velocimetry (PIV). High-velocity jets were observed at the hinge outflow, with time-average velocity up to 5.7 m/s, higher than reported in previous literature. Mean viscous shear stress is up to 60 Pa. For the first time, strongly unsteady flow has been observed in the leakage jet. Peak instantaneous shear stress is up to 120 Pa, twice as high as the average value. These high-resolution measurements identify the hinge leakage jet as a region of very high fluctuating shear stress which is likely to be thrombogenic and should be an important target for future design improvement.


Asunto(s)
Simulación por Computador , Prótesis Valvulares Cardíacas/efectos adversos , Hidrodinámica , Resistencia al Corte , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA