Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Ther Ultrasound ; 5: 8, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28194274

RESUMEN

BACKGROUND: Magnetic resonance high-intensity focused ultrasound (MR-HIFU) treatment for uterine fibroids is rapidly gaining popularity as a treatment modality. This procedure is generally uncomfortable, painful, and requires minimal or absence of movement and an MR-HIFU synchronised breathing pattern of the patient. Procedural sedation and analgesia protocols have become the standard practice in interventional radiology departments worldwide. The aim of this study was to explore if a sedation regimen with low-dose propofol and ketamine performed by trained non-medical sedation practitioners could result in relief of discomfort for the patient and in adequate working conditions for MR-HIFU treatment for uterine fibroids. METHODS: In this study, conducted from August 2013 until November 2014, 20 patients were subjected to MR-HIFU treatment of uterine fibroids. Patients were deeply sedated using intravenous propofol and esketamine according to a standardised hospital protocol to allow synchronisation of the breathing pattern to the MR-HIFU. The quality of sedation for MR-HIFU and complications were recorded and analysed. The side effects of the sedation technique, the propofol and esketamine consumption rate, the duration of recovery, and patient satisfaction after 24 h were examined. RESULTS: A total of 20 female patients (mean age 42.4 [range 32-53] years) were enrolled. Mean propofol/esketamine dose was 1309 mg/39.5 mg (range 692-1970 mg/ 23.6-87.9 mg). Mean procedure time was 269 min (range 140-295 min). Application of the sedation protocol resulted in a regular breathing pattern, which could be synchronised with the MR-HIFU procedures without delay. The required treatment was completed in all cases. There were no major adverse events. Hypoxemia (oxygen desaturation <92%) and hallucinations were not observed. CONCLUSIONS: The use of a specific combination of IV propofol and esketamine for procedural sedation and analgesia reduced the discomfort and pain during MR-guided HIFU treatments of uterine fibroids. The resulting regular breathing pattern allowed for easy synchronisation of the MR-HIFU procedure. Based on our results, esketamine and propofol sedation performed by trained non-medical sedation practitioners is feasible and safe, has a low risk of major adverse events, and has a short recovery time, avoiding a session of general anaesthesia.

2.
Br J Surg ; 103(6): 644-655, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26990850

RESUMEN

BACKGROUND: With the increasing use of neoadjuvant chemotherapy and minimally invasive ablative therapy in breast cancer, pretreatment assessment of tumour grade on core needle biopsy (CNB) is increasingly needed. However, grading on CNB is possibly less accurate than grading based on the surgical excision specimen. A systematic review and meta-analysis of the literature was conducted to derive a reliable estimate of the agreement in tumour grading between CNB and subsequent surgical excision. METHODS: Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) criteria, Embase, PubMed and the Cochrane Library were searched. Pooled proportions of agreement in grading between CNB and the excision specimen, Cohen's κ and percentages of overestimation and underestimation were calculated. Random-effects models were applied because of substantial heterogeneity, assessed by I2 test. Determinants of the level of agreement in grading were explored with meta-regression. RESULTS: Thirty-four articles were included in the systematic review (6029 patients) and 33 in the meta-analysis (4980 patients). Pooled agreement and κ were 71·1 (95 per cent c.i. 68·8 to 73·3) per cent and 0·54 (0·50 to 0·58) respectively. Underestimation and overestimation occurred in 19·1 (17·1 to 21·3) and 9·3 (7·7 to 11·4) per cent respectively. Meta-regression showed associations between agreement of histological type (positive association) and proportion of patients with oestrogen receptor-positive disease (negative association) and grade agreement. CONCLUSION: Grading on CNB corresponds moderately with grading based on excision specimens, with underestimation in about one in five patients. Incorrect CNB tumour grading has limited clinical implications, as multiple factors influence decision-making for adjuvant systemic therapy.


Asunto(s)
Biopsia con Aguja Gruesa/métodos , Neoplasias de la Mama/patología , Mama/patología , Femenino , Humanos , Mastectomía/métodos , Clasificación del Tumor
3.
Phys Med Biol ; 60(14): 5527-42, 2015 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-26133986

RESUMEN

MR-guided HIFU ablation is a promising technique for the non-invasive treatment of breast cancer. A phase I study was performed to assess the safety and treatment accuracy and precision of MR-HIFU ablation in breast cancer patients (n=10) using a newly developed MR-HIFU platform dedicated to applications in the breast. In this paper a technical analysis of the performance of the dedicated breast MR-HIFU system during breast tumors ablation is described. The main points of investigation were the spatial targeting accuracy and precision of the system and the performance of real-time respiration-corrected MR thermometry.The mean targeting accuracy was in the range of 2.4-2.6 mm, whereas the mean targeting precision was in the range of 1.5-1.8 mm. To correct for respiration-induced magnetic field fluctuations during MR temperature mapping a look-up-table (LUT)-based correction method was used. An optimized procedural sedation protocol in combination with the LUT-based correction method allowed for precise MR thermometry during the ablation procedure (temperature standard deviation <3 °C). No unwanted heating in the near field (i.e. skin) nor in the far field (pectoral muscle) was detected.The newly developed dedicated breast MR-HIFU system allows for safe, accurate and precise ablation of breast tumors.


Asunto(s)
Neoplasias de la Mama/cirugía , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Termometría/métodos , Mama/citología , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Estudios de Casos y Controles , Medios de Contraste/metabolismo , Femenino , Voluntarios Sanos , Humanos , Invasividad Neoplásica , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...